RANCANG BANGUN ALAT UKUR KADAR OKSIGEN (PULSE OXIMETRY)
PADA DARAH SECARA NON INVASIVE BERBASIS MIKROKONTROLLER
ATMEGA 8535
DESIGN OF OXYGEN MEASUREENT (PULSE OXIMETRY)
IN BLOOD NON INVASIVE BASED MICROCONTROLLER
ATMEGA 8535
Created by HAK, SYAIFUL
Subject

: Measuring instruments

Subject Alt

: Measuring instruments

Keyword :

: Pulse Oximetry; Non-Invasive; Oxyhemoglobin; Deoxyhemoglobin; Oksigen Saturasi.

Description :
Telah dirancang suatu alat ukur kadar oksigen (Pulse oximetry) pada darah secara non-invasive berbasis mikrokontroller
atmega 8535. Alat ini digunakan untuk mengukur persentase kadar oksigen pada darah (SpO2) yang saturasi di dalam
darah tanpa harus melukai tubuh. Metode ini menggunakan perbedaan panjang gelombang dari cahaya merah (660 nm)
dan cahaya inframerah (940 nm) yang ditangkap oleh sensor deteksi setelah melewati pembuluh balik dan pembuluh
kapiler pada ujung jari telunjuk. Data dari sensor deteksi tersebut dikirim ke rangkaian pengkondisian sinyal untuk
memisahkan antara tegangan AC dan tegangan DC. Keluaran dari rangkaian pengkondisian sinyal tersebut akan menjadi
input mikrokontroller kemudian ditampilkan ke LCD. Di dalam mikrokontroller, data tersebut diolah kemudian diproses
untuk mendapatkan data oksigen saturasi. Batas normal oksigen saturasi dalam darah adalah diatas 90%. Setelah
dilakukan percobaan alat ukur ini mempunyai persentase error sebesar 0,133%.

Description Alt:
Design of measurement oxygen levels (Pulse oximetry) on non-invasive blood-based on microcontroller ATmega
8535 has been already done. This tool is used to measure the percentage of oxygen levels in blood saturation (SpO2)
without having to harm the body. This method uses the difference in wavelengths of red light (660 nm) and infrared
light (940 nm) are captured by the sensor detection after going through the vein and capillary vessels on the tip of your
index finger. Data from the sensor detection is sent to signal conditioning circuit to separate between the voltage AC and
DC voltage. The output of the signal conditioning circuit will be then shown to the input microcontroller LCD. In the
microcontroller, the data is processed and its obtain for oxygen saturation. Normal oxygen saturation in the blood is
above 90%. After the experiment it had a gauge of 0,133% percentage error.

Contributor

: Suyanto, ST, MT

Date Create

: 23/07/2012

Type

: Text

Format

: pdf

Language

: Indonesian

Identifier

: ITS-NonDegree-24002130000373

Collection

: 24002130000373

Page 1

Call Number

: RSF 681.2 Hak r

Source

: Non Degree of Physics Engineering, RSF 681.2 Hak r, 2013

COverage

: ITS Community

Right

: Copyright @2012 by ITS Library. This publication is protected by copyright and per obtained
from the ITS Library prior to any prohibited reproduction, storage in a re transmission in any form
or by any means, electronic, mechanical, photocopying, reco For information regarding
permission(s), write to ITS Library

Full file - Member Only


If You want to view FullText...Please Register as MEMBER

Contact Person :
Administrator (timit_perpus@its.ac.id)
Taufik Rachmanu (taujack@its.ac.id)
Moh. Fandika Aqsa (fandikaaqsa@yahoo.co.id)
Tondo Indra Nyata (tondoindra@gmail.com)
Aprillia Tri Wulansari (rezha_la2@ymail.com)

Thank You,

Nur Hasan ( hassane@its.ac.id )


Supervisor

Page 2

Anda mungkin juga menyukai