LAMPIRAN B

PERHITUNGAN

 Run I, Bukaan Panas (Tube) = 85°, Bukaan Dingin (Shell) = 65°


1. Suhu 44°C
T1 = 39,8 °C = 103,64°F
T2 = 37 °C = 98,6°F
t1 = 29 °C = 84,2°F
t2 = 30 °C = 86°F

a. W Pada aliran panas


𝑄 = 17,8 L/menit = 102,57 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb °F
Q = W.Cp(T1 – T2)
102,57 = W × 0,43 (103,64 – 98,6)
102,57 = 2,167W
W = 47,33 lb/hr

W Pada aliran dingin


𝑄 = 6 L/menit = 34,57 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,435 Btu/lb °F
Q = W.Cp(t2 – t1)
34,57 = W × 0,435 (86 – 84,2)
34,57 = 0,783W
W = 44,15 lb/hr
b. LMTD
(T1 - t2 )- (T2 - t1 )
LMTD = (T -t )
ln 1 2
(T2 - t1 )

(103,64- 86)- (98,6 - 84,2)


= ( 103,6- 86)
ln(98,6
-84,2)

3,24 3,24
= 17,64 = 0,203 = 15,962
ln
14,4

(T1 - T2 ) (103,64 – 98,6) 5,04


c. R= (t2 -t1 )
= (86 - 84,2)
= 1,8
= 2,8

(t2 - t1 ) (86 - 84,2) 1,8


d. S= = (103,6- 84,2)
= =0,093
(T1 -t1 ) 19,4

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,98
∆t=LMTD (Ft)= 15,962(0,98)=15,643

f. Ta dan ta
103,64+98,6
Ta = = 101,12
2
84,2+86
ta = 2
= 85,1

Temperatur rata Ta dan ta adalah Ta = 101,12 dan ta = 85,1

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As = = = 0,0014 ft2
4 4
 Mass Velocity
W 47,33
Gt= = =33807,14 lb⁄
As 0,0014 hr. ft2

 Velocity Through Tube


Gt
V = 3600ρ
33807,14
= 3600 × 62,5

= 0,15 fps

 Pada Ta = 101,12°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 101,12°F diperoleh
diperoleh 𝜇 = 0,65 centipoises
𝜇 = 0,65 × 2,42
= 1,573 lb ft hr

Gt
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 101,12°F diperoleh
𝜇 = 0,65 lb ft hr

𝜇 = 0,65 × 2,42
= 1,573 lb ft hr
De Gs 0,042 × 33807,14
Ret= = = 902,67
μ 1,573

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 3
 Pada Ta = 101,12°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,44 Btu/lb°F
K = 0,374 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(1,573)]3 0,884
= = = 0,363
k 0,374 0,374

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,374
=3 (0,042) [0,363] (1)

= 22,92

 Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:


hi = 22,92 × 1,04
=23,84
0,041
hio = 23,84 × = 23,27
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 23,27 ×10,694
UC = ℎ𝑖𝑜+ℎ𝑜 = 23,27 + 10,694 = 7,32 Btu/(hr)(ft2)(°F)

 Design overall coefficient UD :

𝑄 102,57
𝑈𝑑 = = = 4662,27 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (15,643)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,32 − 4662,27
Rd = 𝑈𝑐𝑈𝐷
= 7,32 × 4662,27
= -0,14
h. Fluida dingin pada bagian Shell
Diameter Shell = 16 cm = 0,53 ft

 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 44,15
Gs= = =200,68 lb⁄
As 0,22 hr ft2

 Pada ta = 85,1
Dari lampiran grafik Fig. 14 Kern halaman 823 pada ta = 85,1°F diperoleh
𝜇 = 0,77 centipoise
𝜇 = 0,77 × 2,42
= 1,863 lb ft hr

De Gs 0,53 × 200,68
Res= = =138,13
μ 0,77
Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :
jH = 6,1

 Pada ta = 85,1°F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,330415 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,863)]3 0,929
= = =2,812
k 0,330415 0,330415
1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,330415
=JH (D) [ ] =6,1 ( ) [2,812]=10,694
∅s K 0,53

 Corrected coefficient:
ho
ho = ∅s ∅𝑠 = 10,694 × 1 = 10,694 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 23,27 × 10,694
UC = ℎ𝑖𝑜+ℎ𝑜 = = 7,52 Btu/(hr)(ft2)(°F)
23,27 + 10,694

 Design overall coefficient UD :

𝑄 34,57
𝑈𝑑 = = = 10,05 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (15,643)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,52 − 10,05
Rd = = = -0,033
𝑈𝑐𝑈𝐷 7,52 × 10,05

2. Suhu 49°C
T1 = 44,2 °C = 111,56 °F
T2 = 42,2 °C = 107,96 °F
t1 = 30,2 °C = 86,36°F
t2 = 32 °C = 89,6 °F

a. W pada aliran panas


𝑄 = 17,2 L/menit = 99,117 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(T1 – T2)
99,117 = W × 0,44 (111,56 – 107,96)
99,117 = 1,584W
W = 64,4 lb/hr

W Pada aliran dingin


𝑄 = 6,2 L/menit = 35,73 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb °F
Q = W.Cp(t2 – t1)
35,73 = W × 0,43 (89,6 – 86,36)
35,73 =1,39 W
W = 25,7 lb/hr

(𝑇1 − 𝑡2 )− (𝑇2 − 𝑡1 )
b. 𝐿𝑀𝑇𝐷 = ( 𝑇1 − 𝑡2 )
ln
(𝑇2 − 𝑡1 )

(111,56− 89,6)− (107,96−86,36)


= ( 111,56−89,6)
ln(107,96
–86,36)

= 3,214

(𝑇1 − 𝑇2 ) (111,56−107,96) 3,6


c. 𝑅 = = = =1,11
(𝑡2 −𝑡1 ) (89,6−86,36) 3,24

(𝑡2 − 𝑡1 ) (89,6−86,36) 3,24


d. 𝑆 = (𝑇1 −𝑡1 )
= (111,56−86,36)
= =0,13
25,2

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa
Ft = 0,99
∆t=LMTD (Ft)= 3,214(0,99)= 3,182
f. Ta dan ta
111,56+107,96
Ta = = 109,76
2
86,36+89,6
ta = = 87,98
2

Temperatur rata Ta dan ta adalah Ta = 109,76 dan ta = 87,98

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft
 Flow Area
π D2 3,14 (0,042 ft)2
As= = = 0,0014 ft2
4 4

 Mass Velocity
W 64,4
Gt= = = 46000 lb⁄
As 0,0014 hr.ft2

 Velocity Through Tube:


Gt
V = 3600ρ
46000
= 3600 × 62,5

= 0,204 fps

 Pada Ta = 111,2
Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 109,76°F
diperoleh 𝜇 = 0,73 centipoises
𝜇 = 0,73 × 2,42
= 1,77 lb ft hr
𝐺𝑡
 𝑅𝑒𝑡 = 𝐷 ( 𝜇 )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 109,76°F diperoleh
𝜇 = 0,73 centipoise

𝜇 = 0,73 × 2,42

= 1,77 lb ft hr

De Gt 0,042 × 46000
Ret= = =1091,53
μ 1,77

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 3

 Pada Ta = 109,76°F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern, halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,34044 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,77)]3 0,913
= = =2,682
k 0,34044 0,34044

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,34044
=3 ( ) [2,682](1) = 65,22
0,042

Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:


hi = 65,22 × 1,04
= 67,83
0,041
hio = 67,83 × = 66,22
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 66,22 × 7,3326
UC = ℎ𝑖𝑜+ℎ𝑜 = = 6,60 Btu/(hr)(ft2)(°F)
66,22 + 7,3326

 Design overall coefficient UD :

𝑄 99,117
𝑈𝑑 = = = 22,026 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (3,182)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 6,60 − 22,026
Rd = = = -0,106
𝑈𝑐𝑈𝐷 6,60 × 22,026

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53 ft)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 25,7
Gs= As = =116,8 lb⁄
0,22 hr.ft2

 Pada ta = 87,98°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada ta = 87,98°F diperoleh
𝜇 = 0,85 centipoise

𝜇 = 0,85 × 2,42
= 2,057 lb ft hr
De Gs 0,53 × 116,8
Res= = =72,83
μ 0,85
Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :
jH = 4

 Pada ta = 87,99°F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern, halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,38004 Btu/hr (ft)2(°F/ft)
1 1
(𝑐 .𝜇)3 [(0,43)(2,057)]3 0,96
= = = 2,53
𝑘 0,38004 0,38004
1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,38004
=JH (D) [ ] =4 ( ) [2,53]= 7,26
∅s K 0,53

 Corrected coefficient:
ℎ𝑜
ho = ∅𝑠 ∅𝑠 = 7,26 × 1 = 7,26 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 66,22 × 7,26
UC = ℎ𝑖𝑜+ℎ𝑜 = = 6,54 Btu/(hr)(ft2)(°F)
66,22 + 7,26

 Design overall coefficient UD :


𝑄 35,73
𝑈𝑑 = = = 51,04 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (3,182)
 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 6,54 − 51,04
Rd = = 6,,54 × 51,04 = -0,13
𝑈𝑐𝑈𝐷

3. Suhu 54°C
T1 = 50 °C = 122 °F
T2 = 48,8 °C = 119,84 °F
t1 = 31,8 °C = 89,24°F
t2 = 32,6 °C = 90,68 °F

a. W pada aliran panas


𝑄 = 16,6 L/menit = 95,66 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb °F
Q = W.Cp(T1 – T2)
95,66 = W × 0,43 (122 – 119,84)
95,66 = 0,93W
W = 102,9 lb/hr

W Pada aliran dingin


𝑄 = 6,2 L/menit = 35,73 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(t2 – t1)
35,73 = W × 0,44 (90,68 – 89,24)
35,73 = 0,633W
W = 56,5 lb/hr

(𝑇1 − 𝑡2 )− (𝑇2 − 𝑡1 )
b. 𝐿𝑀𝑇𝐷 = ( 𝑇1 − 𝑡2 )
ln
(𝑇2 − 𝑡1 )
(122− 90,68)− (119,84 – 89,24)
= ( 122− 90,68)
ln(119,84
– 89,24)

= 3,27

(𝑇1 − 𝑇2 ) (122−119,84) 2,16


c. 𝑅 = = = =1,5
(𝑡2 −𝑡1 ) (90,68−89,24) 1,44

(𝑡2 − 𝑡1 ) (90,68−89,24) 1,44


d. 𝑆 = (𝑇1 −𝑡1 )
= (122−119,84)
= = 0,67
2,16

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa:
Ft = 0,97
∆t=LMTD (Ft)= 3,27(0,97)= 3,172

f. Ta dan ta
122+119,84
Ta = = 120,92
2
89,24+90,68
ta = = 89,96
2

Temperatur rata Ta dan ta adalah Ta = 120,92 dan ta = 89,96

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft
 Flow Area
π D2 3,14 (0,042 ft)2
As= = = 0,0014 ft2
4 4

 Mass Velocity
W 102,9
Gt= = =73500 lb⁄
As 0,0014 hr.ft2
 Velocity Through Tube
Gt
V = 3600ρ
73500
= 3600 × 62,5

= 0,327 fps

 Pada Ta = 120,92℉
Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 120,92°F
diperoleh 𝜇 = 0,6 centipoises
𝜇 = 0,6 × 2,42
= 1,452 lb ft hr

Gt
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 pada Ta = 120,92°F diperoleh 𝜇 = 0,6 lb ft hr


𝜇 = 0,6 × 2,42
= 1,452 lb ft hr
De Gt 0,042 × 73500
Ret= = =5145
μ 0,6

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 16

 Pada Ta = 120,92°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel. 4 Kern, halaman
800 diperoleh:
C = 0,43 Btu/lb°F
K = 0,3642
1 1
(c . μ)3 [(0,43)(1,452)]3 0,855
= = =2,35
k 0,3642 0,3642

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,3642
=16 ( 0,042 ) [2,35](1)= 326,05

Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:


hi = 326,05 × 1,04
= 339,092
0,041
hio = 339,092 × = 331,02
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 331,02 × 7,32
UC = ℎ𝑖𝑜+ℎ𝑜 = = 7,2 Btu/(hr)(ft2)(°F)
331,02+ 7,32

 Design overall coefficient UD :

𝑄 95,66
𝑈𝑑 = = = 21541,16 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (3,172)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,2 − 21541,16
Rd = = = -0,73
𝑈𝑐𝑈𝐷 7,2 × 31633,6

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53 ft)2
As= = = 0,22 ft2
4 4
 Mass Velocity
W 56,5
Gs= As = =256,8 lb⁄
0,22 hr.ft2

 Pada ta = 89,96°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada ta = 89,96°F diperoleh
𝜇 = 0,8 centipoise
𝜇 = 0,8 × 2,42
= 1,936 lb ft hr

De Gs 0,53 × 256,8
Res= = = 70,302
μ 1,936

Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :


jH = 4,6

 Pada ta = 89,96°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Table. 4 Kern, halaman
800 diperoleh:
C = 0,44 Btu/lb°F
K = 0,3791 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(1,936)]3 0,948
= = =2,5
k 0,3791 0,3791

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,3791
=JH (D) [ ] = 4,6 ( ) [2,5]= 8,23
∅s K 0,53

 Corrected coefficient,
ℎ𝑜
ho = ∅𝑠 ∅𝑠 = 8,23 × 1 = 8,23 Btu/(hr)(ft2)(°F)
 Clean overall coefficient UC :
ℎ𝑖𝑜ℎ𝑜 331,02 × 8,32
UC = ℎ𝑖𝑜+ℎ𝑜 = = 8,12 Btu/(hr)(ft2)(°F)
331,02 + 8,32

 Design overall coefficient UD :


𝑄 35,73
𝑈𝑑 = = = 51,201 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (3,172)

 Dirt factor Rd :

𝑈𝑐 − 𝑈𝐷 8,12 − 51,201
Rd = = = -0,103
𝑈𝑐𝑈𝐷 8,12 × 51,201

 Run II, Bukaan Panas (Tube) = 75°, Bukaan Dingin (Shell) = 75°
1. Suhu 44°C
T1 = 41°C =110,8 °F
T2 = 40 °C =104°F
t1 = 30°C =86 °F
t2 = 31 °C =87,8 °F

a. W Pada aliran panas


𝑄 = 16 L/menit = 92,2 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,45 Btu/lb °F
Q = W.Cp(T1 – T2)
92,2 = W × 0,45 (105,8 – 104)
92,2 = 0,81W
W = 113,83 lb/hr

W Pada aliran dingin


𝑄 = 6,8 L/menit = 35,73 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,46 Btu/lb °F
Q = W.Cp(t2 – t1)
35,73 = W × 0,46 (87,8 – 86)
35,73 = 0,83W
W = 43,05 lb/hr

b. LMTD
(𝑇1 − 𝑡2 )− (𝑇2 − 𝑡1 )
LMTD = ( 𝑇1 − 𝑡2 )
ln
(𝑇2 − 𝑡1 )

(110,8− 87,8)− (104 – 86)


= ( 110,8− 87,8)
𝑙𝑛 (104
– 86)

= 4,73

(T1 - T2 ) (110,8 –104) 6,8


c. R= = = = 3,78
(t2 -t1 ) (87,8 – 86) 1,8

(t 2 - t 1 ) (87,8 – 86) 1,8


d. S= (T1 -t 1 )
= (110,8-86)
= =0,07
24,8

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa:
Ft = 0,99
∆t=LMTD (Ft)= 4,73 (0,99) = 4,683

f. Ta dan ta
110,8+104
Ta = = 107,4
2
86+87,8
ta = = 86,9
2

Temperatur rata Ta dan ta adalah Ta = 107,4 dan ta = 86,9

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As= = = 0,0014 ft2
4 4

 Mass Velocity
W 113,83
Gt= = =81307,14 lb⁄
As 0,0014 hr. ft2

 Velocity Through Tube


Gt
V = 3600ρ
81307,14
= 3600 × 62,5

= 0,361 fps

 Pada Ta = 111,2
Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 107,4°F diperoleh
𝜇 = 0,6 centipoises
𝜇 = 0,6 × 2,42
= 1,452 lb ft hr

𝐺𝑡
 𝑅𝑒𝑡 = 𝐷 ( 𝜇 )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Tc = 107,4°F diperoleh
𝜇 = 0,6 lb ft hr
𝜇 = 0,6 × 2,42
= 1,452 lb ft hr
De Gt 0,042 × 81307,14
Ret= = = 2351,86
μ 1,452

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 3,7

 Pada Ta = 107,4°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel. 4 Kern, halaman
800 diperoleh:
C = 0,43 Btu/lb°F
K = 0,3707 Btu/hr (ft)2(°F/ft)
1 1
(𝑐 .𝜇)3 [(0,43)(1,452)]3 0,855
= = = 2,306
𝑘 0,3707 0,3707

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,3707
= 3,7 ( 0,042 ) [2,306] (1)

= 75,31
Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:
hi = 75,31 × 1,04
= 78,32
0,041
hio = 78,32 × = 76,46
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 76,46 × 8,54
UC = ℎ𝑖𝑜+ℎ𝑜 = = 7,7 Btu/(hr)(ft2)(°F)
76,46 + 8,54

 Design overall coefficient UD :

𝑄 92,2
𝑈𝑑 = = = 13969,7 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (4,683)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,7 − 13969,7
Rd = = = -0,13
𝑈𝑐𝑈𝐷 7,7 × 13969,7

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 43,05
Gs= As = =195,68 lb⁄
0,22 hr ft2

 Pada ta = 86,9°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada ta = 86,9°F diperoleh 𝜇
= 0,8 centipoises
𝜇 = 0,8 × 2,42
= 1,936 lb ft hr

De Gs 0,53 × 195,68
Res= = = 53,57
μ 1,936

Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :


jH = 3,9
 Pada ta = 86,63°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Table. 4 Kern, halaman
800 diperoleh:
C = 0,43 Btu/lb°F
K = 0,3807 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,936)]3 0,941
= = = 2,472
k 0,3807 0,3807

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,3807
=JH (D) [ ] = 3,9 ( ) [2,472]= 8,54
∅s K 0,43

 Corrected coefficient:
ℎ𝑜
ho = ∅𝑠 = 8,54 × 1 = 8,54 Btu/(hr)(ft2)(°F)
∅𝑠

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 76,46 × 8,54
UC = ℎ𝑖𝑜+ℎ𝑜 = = 7,7 Btu/(hr)(ft2)(°F)
76,46+ 8,54

 Design overall coefficient UD :

𝑄 35,73
𝑈𝑑 = = = 34,68 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (4,683)

 Dirt factor Rd :

𝑈𝑐 − 𝑈𝐷 7,7 − 34,68
Rd = = = -0,10
𝑈𝑐𝑈𝐷 7,7 × 34,68
2. Suhu 49°C
T1 = 47,2 °C = 116,96°F
T2 = 46,6 °C = 115,88°F
t1 = 29 °C = 84,2°F
t2 = 30,4 °C = 86,72°F

a. W Pada aliran panas


𝑄 = 15,8 L/menit = 91,04 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(T1 – T2)
91,04 = W × 0,44 (116,96 – 115,88)
91,04 = 0,4752W
W = 191,58 lb/hr

W Pada aliran dingin


𝑄 = 6,8 L/menit = 35,73 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb °F
Q = W.Cp(t2 – t1)
35,73 = W × 0,43 (86,72 – 84,2)
35,73 = 1,0836W
W = 32,97 lb/hr

b. LMTD
(𝑇1 − 𝑡2 )− (𝑇2 − 𝑡1 )
LMTD = ( 𝑇1 − 𝑡2 )
ln
(𝑇2 − 𝑡1 )

(116,96− 86,72)− (115,88 – 84,2)


= ( 116,96− 86,72)
𝑙𝑛 (15,882
– 84,2)
= 31,3

(T1 - T2 ) (116,96 – 115,88) 1,08


c. R= = = = 0,397
(t2 -t1 ) (86,72 – 84) 2,72

(t2 - t1 ) (86,72 – 84) 2,72


d. S= = = =0,089
(T1 -t1 ) (116,96-86,72) 30,24

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,99
∆t=LMTD (Ft)= 31,3(0,99)= 30,1

f. Ta dan ta
116,96+115,88
Ta = = 116,42
2
84,2+86,72
ta = = 85,46
2

Temperatur rata Ta dan ta adalah Ta = 116,42 dan ta = 85,46

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As= = = 0,0014 ft2
4 4

 Mass Velocity
W 191,58
Gt= = =136842,85 lb⁄
As 0,0014 hr. ft2
Gt
Vel, V = 3600ρ
136842,85
= 3600 × 62,5

= 0,61 fps

 Pada Ta = 116,42
Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 116,42°F
diperoleh 𝜇 = 0,6 centipoises
𝜇 = 0,6 × 2,42
= 1,452 lb ft hr

Gt
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 116,42°F


diperoleh 𝜇 = 0,6 centipoises
𝜇 = 0,6 × 2,42
= 1,452 lb ft
Dari lampiran grafik Fig. 14 pada Tc = 116,36°F diperoleh 𝜇 = 0,68 lb ft hr

De Gt 0,042 × 136842,85
Ret= = = 3958,26
μ 1,452

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern halaman 834 pada lampiran grafik diperoleh :


jH = 13

 Pada Ta = 116,42°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel. 4 Kern, halaman
800 diperoleh:
C = 0,44 Btu/lb°F
K = 0,3664 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(1,452)]3 2,351
= = = 6,42
k 0,3664 0,3664

1
K (C μ )3
 hi=JH ( ) [ ] ∅t
D K

0,3664
= 13 ( 0,042 ) [6,42] (1)

= 728,1
Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:
hi = 728,1 × 1,04
=757,224
0,041
hio = 757,224 × = 739,21
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 739,21 × 37,5
UC = ℎ𝑖𝑜+ℎ𝑜 = = 35,7 Btu/(hr)(ft2)(°F)
739,21 + 37,5

 Design overall coefficient UD :

𝑄 35,73
𝑈𝑑 = = = 84,8 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (30,1)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 35,7 − 84,8
Rd = = = -0,016
𝑈𝑐𝑈𝐷 35,7 × 84,8

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 32,97
Gs= = = 149,86 lb⁄
As 0,22 hr ft2

 Pada ta = 85,46°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada ta = 85,46°F diperoleh 𝜇
= 0,85 centipoises
𝜇 = 0,85 × 2,42
= 2,057 lb ft hr

De Gs 0,53 × 149,68
Res= = = 38,6
μ 2,057

Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :


jH = 3,5

 Pada ta = 85,46°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Table. 4 Kern, halaman
800 diperoleh:
C = 0,44 Btu/lb°F
K = 0,33025 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(1,452)]3 0,86
= = = 2,604
k 0,33025 0,33025

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 2,057
=JH ( ) [ ] =3,5 ( ) [2,604]= 37,5
∅s D K 0,53
 Corrected coefficient:
ℎ𝑜
ho = ∅𝑠 ∅𝑠 = 37,5 × 1 = 37,5 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 739,21 × 37,5
UC = ℎ𝑖𝑜+ℎ𝑜 = = 35,7 Btu/(hr)(ft2)(°F)
739,21 + 37,5

 Design overall coefficient UD :

𝑄 32,97
𝑈𝑑 = = = 4,98 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (30,1)

 Dirt factor Rd :

𝑈𝑐 − 𝑈𝐷 35,7 − 4,98
Rd = = = -0,173
𝑈𝑐𝑈𝐷 35,7 × 4,98

3. Suhu 54°C
T1 = 51 °C = 123,8°F
T2 = 49,6 °C = 121,28°F
t1 = 29 °C = 84,2°F
t2 = 30,6 °C = 87,08°F

a. W Pada aliran panas


𝑄 = 15 L/menit = 86,44 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb °F
Q = W.Cp(T1 – T2)
86,44 = W × 0,43 (123,8 – 121,28)
86,44 = 2,52W
W = 34,302 lb/hr
W Pada aliran dingin
𝑄 = 7 L/menit = 40,34 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,43 Btu/lb °F
Q = W.Cp(t2 – t1)
40,34 = W × 0,43 (87,08 – 84,2)
40,34 = 1,24W
W = 32,53 lb/hr

b. LMTD
(𝑇1 − 𝑡2 )− (𝑇2 − 𝑡1 )
LMTD = ( 𝑇1 − 𝑡2 )
ln
(𝑇2 − 𝑡1 )

(123,8- 87,08)- (121,28 – 84,2)


= ( 123.8- 87,08)
ln(121,28
– 84,2)

-0,36 -0,36
= 36,72 = = 3,67
ln -0,0098
37,08

(T1 - T2 ) (123,8 – 121,28) 2,52


c. R= = = = 0,82
(t2 -t1 ) (87,08 – 84,2) 3,06

(t2 - t1 ) (87,08 – 84,2) 3,06


d. S= = = = 0,077
(T1 -t1 ) (123,8-84,2) 39,6

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,99
∆t=LMTD (Ft)= 3,67 (0,99)= 3,63
f. Ta dan ta
123,8+121,28
Ta = = 122,54
2
84,2+87,08
ta = = 85,64
2

Temperatur rata Ta dan ta adalah Ta = 122,54 dan ta = 85,64

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As= = = 0,0014 ft2
4 4

 Mass Velocity
W 34,302
Gt= = =24501,43 lb⁄
As 0,0014 hr. ft2

 Velocity Through Tube:


Gt
V = 3600ρ
24501,43
= 3600 × 62,5

= 0,11 fps

 Pada Ta = 122,54
Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 122,54°F
diperoleh 𝜇 = 0,6 centipoises
𝜇 = 0,6 × 2,42
= 1,452 lb ft hr
Gt
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 Kern, halaman, 823 pada Ta = 122,54°F


diperoleh 𝜇 = 0,6 centipoises
𝜇 = 0,6 × 2,42
= 1,452 lb ft
Dari lampiran grafik Fig. 14 pada Tc = 116,36°F diperoleh 𝜇 = 0,68 lb ft hr

De Gt 0,042 × 24501,43
Ret= = = 708,72
μ 1,452

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern halaman 834 pada lampiran grafik diperoleh :


jH = 25

 Pada Ta = 122,54°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel. 4 Kern, halaman
800 diperoleh:
C = 0,43 Btu/lb°F
K = 0,3634 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,452)]3 0,86
= = = 2,37
k 0,3634 0,3634

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,3634
= 25 ( 0,042 ) [2,37] (1)

= 512,7
Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:
hi = 512,7 × 1,04
=533,208
0,041
hio = 512,7 × = 500,5
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 500,5 × 6,41
UC = ℎ𝑖𝑜+ℎ𝑜 = = 6,33 Btu/(hr)(ft2)(°F)
500,5 + 6,41

 Design overall coefficient UD :

𝑄 86,44
𝑈𝑑 = = = 17009,05 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (3,63)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 6,33 − 17009,05
Rd = = = -0,16
𝑈𝑐𝑈𝐷 6,33 × 17009,05

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 32,53
Gs= = = 147,87 lb⁄
As 0,22 hr ft2

 Pada ta = 85,64°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada ta = 85,64°F diperoleh 𝜇
= 0,85 centipoises
𝜇 = 0,85 × 2,42
= 2,057 lb ft hr
De Gs 0,53 × 147,87
Res= = = 38,1
μ 2,057

Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :


jH = 3,5

 Pada ta = 85,64°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Table. 4 Kern, halaman
800 diperoleh:
C = 0,44 Btu/lb°F
K = 0,3302 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(2,057)]3 0,97
= = = 2,94
k 0,3302 0,3302

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,3302
=JH ( ) [ ] =3,5 ( ) [2,94]= 6,41
∅s D K 0,53

 Corrected coefficient:
ℎ𝑜
ho = ∅𝑠 ∅𝑠 = 6,41 × 1 = 6,41 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 500,5 × 6,41
UC = ℎ𝑖𝑜+ℎ𝑜 = = 6,33 Btu/(hr)(ft2)(°F)
500,5 + 6,41

 Design overall coefficient UD :

𝑄 40,34
𝑈𝑑 = = = 50,51 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (3,63)
 Dirt factor Rd :

𝑈𝑐 − 𝑈𝐷 6,33 − 50,51
Rd = = = -0,14
𝑈𝑐𝑈𝐷 6,33 × 50,51

 Run III, Bukaan Panas (Tube) = 85°, Bukaan Dingin (Shell) = 65°
1. Suhu 44°C
T1 = 37,4 °C = 99,32°F
T2 = 37 °C = 98,6°F
t1 = 31 °C = 87,8°F
t2 = 31,6 °C = 88,88°F

a. W Pada aliran panas


𝑄 = 15 L/menit = 86,44 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(T1 – T2)
86,44 = W × 0,44 (99,32 – 98,6)
86,44 = 0,32W
W = 270,125 lb/hr

W Pada aliran dingin


𝑄 = 6 L/menit = 34,57 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(t2 – t1)
40,34 = W × 0,44 (88,88 – 87,8)
40,34 = 0,4752W
W = 19,169 lb/hr
b. LMTD
(T1 - t2 )- (T2 - t1 )
LMTD = (T -t )
ln 1 2
(T2 - t1 )

(99,32- 88,88)- (98,6 – 87,8)


= ( 99,32- 88,8)
ln (98,6
-87,8)

-0,36 -0,36
= 10,44 = -0,034 = 10,58
ln
10,8

(T1 - T2 ) (99,32 – 98,6) 0,72


c. R= (t2 -t1 )
= (88,88 – 87,8)
= 1,08
= 0,666

(t2 - t1 ) (88,88 – 87,8) 1,08


d. S= = (99,32- 87,8)
= = 0,093
(T1 -t1 ) 11,52

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,99
∆t=LMTD (Ft)= 10,58(0,99)= 10,7

f. Ta dan ta
99,32+98,6
Ta = = 98,96
2
88,88+87,8
ta = 2
= 88,34

Temperatur rata Ta dan ta adalah Ta = 98,96 dan ta = 88,34

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As = = = 0,0014 ft2
4 4
 Mass Velocity
W 270,125
Gt= = = 192946,43 lb⁄
As 0,0014 hr. ft2

 Velocity Through Tube


Gt
V = 3600ρ
192946,43
= 3600 × 62,5

= 0,86 fps

 Pada Ta = 98,6°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 98,96°F diperoleh
diperoleh 𝜇 = 0,75 centipoises
𝜇 = 0,75 × 2,42
= 1,82 lb ft hr

Gs
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 98,96°F diperoleh
𝜇 = 0,75 lb ft hr

𝜇 = 0,75 × 2,42
= 1,82 lb ft hr
De Gt 0,042 × 192946,43
Ret= = = 4452,6
μ 1,82

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 16
 Pada Ta = 98,96°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,375 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,82)]3 0,922
= = = 2,46
k 0,375 0,375
1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,374
= 16 (0,042) [2,46](1)

= 350,5
Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:
hi = 350,5 × 1,04
= 364,52
0,041
hio = 350,5 × = 342,16
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 342,16 ×4,76
UC = ℎ𝑖𝑜+ℎ𝑜 = 342,16 + 4,76 = 4,7 Btu/(hr)(ft2)(°F)

 Design overall coefficient UD :

𝑄 86,44
𝑈𝑑 = = = 5770,36 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (10,7)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 4,7 − 5770,36
Rd = = = -0,21
𝑈𝑐𝑈𝐷 4,7 × 5770,36
h. Fluida dingin pada bagian Shell
Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 19,169
Gs= = = 87,13 lb⁄
As 0,22 hr ft2

 Pada ta = 88,34°F
Dari lampiran grafik Fig. 14 Kern halaman 823 pada ta = 88,34°F diperoleh
𝜇 = 0,78 centipoise
𝜇 = 0,78 × 2,42
= 1,89 lb ft hr

De Gs 0,53 × 87,13
Res= = = 24,43
μ 1,89
Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :
jH = 2,7

 Pada ta = 88,34°F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,3798 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,89)]3 0,933
= = = 2,46
k 0,3798 0,3798

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K
1
ho K (C.μ )3 0,3798
=JH ( ) [ ] = 2,7 ( ) [2,46]= 4,76
∅s D K 0,53

 Corrected coefficient:
ho
ho = ∅s ∅𝑠 = 4,76 × 1 = 4,76 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 342,16× 4,76
UC = ℎ𝑖𝑜+ℎ𝑜 = 342,16 + 4,76 = 4,7 Btu/(hr)(ft2)(°F)

 Design overall coefficient UD :

𝑄 34,57
𝑈𝑑 = = = 14,7 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (10,7)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 4,7 − 14,7
Rd = = = -0,14
𝑈𝑐𝑈𝐷 4,7 × 14,7

2. Suhu 49°C
T1 = 43,2 °C = 109,76°F
T2 = 40 °C = 104°F
t1 = 31,2 °C = 88,16°F
t2 = 32,4 °C = 90,32°F

a. W Pada aliran panas


𝑄 = 15 L/menit = 86,44 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(T1 – T2)
86,44 = W × 0,44 (109,76 – 104)
86,44 = 2,534W
W = 34,11 lb/hr

W Pada aliran dingin


𝑄 = 7,1 L/menit = 40,91 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(t2 – t1)
40,91 = W × 0,44 (89,6 – 88,16)
40,91 = 0,634W
W = 64,53 lb/hr

b. LMTD
(T1 - t2 )- (T2 - t1 )
LMTD = (T -t )
ln 1 2
(T2 - t1 )

(109,76- 90,32)- (104 – 88,16)


= ( 109,76- 90,32)
ln (104
-88,16)

3,6 3,6
= 19,44 = 0,205 = 17,6
ln
15,84

(T1 - T2 ) (109,76 – 104) 5,76


c. R= = = = 2,66
(t2 -t1 ) (90,32 – 88,16) 2.16

(t2 - t1 ) (90,32 – 88,16) 2,16


d. S= = (109,76- = = 0,1
(T1 -t1 ) 88,16) 21,6

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,99
∆t=LMTD (Ft)= 17,6(0,99)= 17,424
f. Ta dan ta
109,76+104
Ta = = 106,88
2
90,32+88,16
ta = = 89,24
2

Temperatur rata Ta dan ta adalah Ta = 106,88 dan ta = 89,24

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As = = = 0,0014 ft2
4 4

 Mass Velocity
W 34,11
Gt= = = 24364,28 lb⁄
As 0,0014 hr. ft2

 Velocity Through Tube


Gt
V = 3600ρ
24364,28
= 3600 × 62,5

= 0,108 fps

 Pada Ta = 106,88°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 101,12°F diperoleh
diperoleh 𝜇 = 0,69 centipoises
𝜇 = 0,69 × 2,42
= 1,67 lb ft hr
Gt
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 106,88°F diperoleh
𝜇 = 0,69 lb ft hr

𝜇 = 0,69 × 2,42
= 1,67 lb ft hr
De Gt 0,042 × 24364,28
Ret= = = 612,754
μ 1,67

L 8,66
 = = 206,19
D 0,042

Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :


jH = 2,6

 Pada Ta = 106,88°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,3709 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,67)]3 0,895
= = = 2,413
k 0,3709 0,3709

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,3709
= 2,6 ( 0,042 ) [2,413](1)

= 55,403
Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:
hi = 55,403 × 1,04
= 57,62
0,041
hio = 57,62 × = 56,25
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 56,25 ×8,52
UC = ℎ𝑖𝑜+ℎ𝑜 = 56,25 + 8,52 = 7,4 Btu/(hr)(ft2)(°F)

 Design overall coefficient UD :

𝑄 86,44
𝑈𝑑 = = = 3543,55 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (17,424)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,4 − 3543,55
Rd = = = -0,135
𝑈𝑐𝑈𝐷 7,4 × 3543,55

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 64,53
Gs= = = 293,32 lb⁄
As 0,22 hr ft2

 Pada ta = 89,24°F
Dari lampiran grafik Fig. 14 Kern halaman 823 pada ta = 89,24°F diperoleh
𝜇 = 0,8 centipoise
𝜇 = 0,8 × 2,42
= 1,936 lb ft hr
De Gs 0,53 × 293,32
Res= = =80,3
μ 1,936
Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :
jH = 4,8

 Pada ta = 89,24°F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,43 Btu/lb°F
K = 0,3794 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,43)(1,936)]3 0,941
= = = 2,48
k 0,3794 0,3794

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,3794
=JH ( ) [ ] = 4,8 ( ) [2,48]= 8,52
∅s D K 0,53

 Corrected coefficient:
ho
ho = ∅s ∅𝑠 = 8,52 × 1,0 = 8,52 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 56,25 × 8,52
UC = ℎ𝑖𝑜+ℎ𝑜 = = 7,4 Btu/(hr)(ft2)(°F)
56,25 + 8,52

 Design overall coefficient UD :

𝑄 40,91
𝑈𝑑 = = = 10,67 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (17,424)
 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,4 − 10,67
Rd = = = -0,04
𝑈𝑐𝑈𝐷 7,4 × 10,67

3. Suhu 54°C
T1 = 45 °C = 113°F
T2 = 44,2 °C = 111,56°F
t1 = 31 °C = 87,8°F
t2 = 32 °C = 89,6°F

a. W Pada aliran panas


𝑄 = 14,8 L/menit = 85,286 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,45 Btu/lb °F
Q = W.Cp(T1 – T2)
85,286 = W × 0,45 (113 – 111,56)
85,286 = 0,648W
W = 131,61 lb/hr

W Pada aliran dingin


𝑄 = 7,8 L/menit = 44,95 Btu/hr
Dari Fig. 3 Kern, halaman 805 dari lampiran grafik diperoleh :
Cp = 0,44 Btu/lb °F
Q = W.Cp(t2 – t1)
44,95 = W × 0,44 (89,6 – 87,8)
44,95 = 0,792W
W = 56,75 lb/hr
b. LMTD
(T1 - t2 )- (T2 - t1 )
LMTD = (T -t )
ln 1 2
(T2 - t1 )

(113- 89,6)- (111,56 – 87,8)


= ( 113- 89,6)
ln(111,56
-87,8)

-0,36 -3,26
= 23,4 = -0,015 = 217,33
ln
23,76

(T1 - T2 ) (113 – 111,56) 1,44


c. R= (t2 -t1 )
= (89,6 – 87,8)
= 1,8
= 0,8

(t2 - t1 ) (89,6 – 87,8) 1,8


d. S= = (113- 87,8)
= =0,071
(T1 -t1 ) 25,2

e. Dari Fig. 19 Kern, halaman 829 pada lampiran grafik dapat dilihat bahwa :
Ft = 0,98
∆t=LMTD (Ft)= 217,33(0,98)=212,98

f. Ta dan ta
113+111,56
Ta = = 112,28
2
87,8+89,6
ta = 2
= 88,7

Temperatur rata Ta dan ta adalah Ta = 112,28 dan ta = 88,7

g. Fluida panas pada bagian Tube


Diameter Tube = 1,27 cm = 0,042 ft
Panjang Tube (L) = 264 cm = 8,66 ft

 Flow Area
π D2 3,14 (0,042 ft)2
As = = = 0,0014 ft2
4 4

 Mass Velocity
W 131,61
Gt= = = 94007,14 lb⁄
As 0,0014 hr. ft2

 Velocity Through Tube


Gt
V =
3600ρ
94007,14
= 3600 × 62,5

= 0,42 fps

 Pada Ta = 112,28°F
Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 112,28°F diperoleh
diperoleh 𝜇 = 0,65 centipoises
𝜇 = 0,65 × 2,42
= 1,573 lb ft hr

Gt
 Ret=D ( μ )

Dari lampiran grafik Fig. 14 Kern, halaman 823 pada Ta = 112,28°F diperoleh
𝜇 = 0,65 lb ft hr

𝜇 = 0,65 × 2,42
= 1,573 lb ft hr
De Gt 0,042 × 94007,14
Ret= = = 2510,04
μ 1,573

L 8,66
 = = 206,19
D 0,042
Dari Fig. 24 Kern, halaman 834 pada lampiran grafik diperoleh :
jH = 4

 Pada Ta = 112,28°F
Dari lampiran grafik Fig. 3 Kern, halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,44 Btu/lb°F
K = 0,356 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(1,573)]3 0,885
= = = 2,5
k 0,356 0,356

1
K (C μ )3
 hi=JH (D) [ ] ∅t
K

0,356
= 4 (0,042) [2,5](1)

= 84,76
Dari lampiran grafik Fig. 25 Kern, halaman 835 diperoleh nilai:
hi = 84,76 × 1,04
= 88,15
0,041
hio = 88,15 × = 86,05
0,042

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 86,05 ×7,64
UC = ℎ𝑖𝑜+ℎ𝑜 = 86,05 + 7,64 = 7,02 Btu/(hr)(ft2)(°F)

 Design overall coefficient UD :


𝑄 85,286
𝑈𝑑 = = = 286,03 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,0014 ft2 (212,98)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,02 − 286,03
Rd = = = -0,14
𝑈𝑐𝑈𝐷 7,02 × 286,03

h. Fluida dingin pada bagian Shell


Diameter Shell = 16 cm = 0,53 ft
 Flow Area
π D2 3,14 (0,53)2
As= = = 0,22 ft2
4 4

 Mass Velocity
W 56,75
Gs= = = 257,954 lb⁄
As 0,22 hr ft2

 Pada ta = 88,7°F
Dari lampiran grafik Fig. 14 Kern halaman 823 pada ta = 88,7°F diperoleh
𝜇 = 0,84 centipoise
𝜇 = 0,84 × 2,42
= 2,033 lb ft hr

De Gs 0,53 × 257,954
Res= = = 67,25
μ 2,033
Dari Fig. 28 Kern, halaman 838 pada lampiran grafik diperoleh :
jH = 4,2

 Pada ta = 88,7°F
Dari lampiran grafik Fig. 3 Kern halaman 805 dan Tabel 4 Kern halaman 800
diperoleh:
C = 0,44 Btu/lb°F
K = 0,3797 Btu/hr (ft)2(°F/ft)
1 1
(c . μ)3 [(0,44)(2,033)]3 0,964
= = =2,54
k 0,3797 0,3797

1
K (C μ )3
 ho=JH (D) [ ] ∅s
K

1
ho K (C.μ )3 0,3797
=JH ( ) [ ] = 4,2 ( ) [2,54]= 7,64
∅s D K 0,53

 Corrected coefficient:
ho
ho = ∅s ∅𝑠 = 7,64 × 1,0 = 7,64 Btu/(hr)(ft2)(°F)

 Clean overall coefficient UC :


ℎ𝑖𝑜ℎ𝑜 86,05 × 7,64
UC = ℎ𝑖𝑜+ℎ𝑜 = = 7,02 Btu/(hr)(ft2)(°F)
86,05 + 7,64

 Design overall coefficient UD :

𝑄 44,95
𝑈𝑑 = = = 0,96 Btu/(hr)(ft2)(°F)
𝐴𝑠 .∆𝑡 0,22 ft2 (212,98)

 Dirt factor Rd :
𝑈𝑐 − 𝑈𝐷 7,02 − 0,96
Rd = = = 0,9
𝑈𝑐𝑈𝐷 7,02 × 0,96