Anda di halaman 1dari 4

LABORATORIUM PENGUJIAN BETON & TANAH

Jl. Kamboja No.1902 Kel.20 Ilir D.III Palembang

DATA HAMMER-MATEST TEST


ASTM C-805-02 / SNI 03-4430-1997

PROYEK : SUBAN COMPRESSION PROJECT


CLIENT : PT. TOTAL PERSADA INDONESIA
SITE : -
ALAT DIGUNAKAN : HAMMER MATEST 2P0435
LOKASI : SUBAN, CONOCOPHILLIPS
DITEST OLEH : AFLAHA
TANGGAL TEST : 08 Januari 2018

01 . A
K.O DRUM Tgl.cor -
RCP Ø 500 MM (Test 1) arah : -90o
skala kg/cm2
1 34
P 2 34
U 3 34
K 4 36
U 5 36
L 6 36
A 7 36
N 8 36
9 36
10 36
R maksimum 36
R minimum 34
R rata-rata 35,40 384,86
Simpangan Baku 0,97
Koef. Variasi 2,73
2
Kuat Tekan Beton (kg/cm ) 382,22
Kuat Tekan Beton (MPa) 31,72
LABORATORIUM PENGUJIAN BETON & TANAH
Jl. Kamboja No.1902 Kel.20 Ilir D.III Palembang

DATA HAMMER-MATEST TEST


ASTM C-805-02 / SNI 03-4430-1997

PROYEK : SUBAN COMPRESSION PROJECT


CLIENT : PT. TOTAL PERSADA INDONESIA
SITE : -
ALAT DIGUNAKAN : HAMMER MATEST 2P0435
LOKASI : SUBAN, CONOCOPHILLIPS
DITEST OLEH : AFLAHA
TANGGAL TEST : 08 Januari 2018

01 . B
K.O DRUM Tgl.cor -
RCP Ø 500 MM (Test 2) arah : 0o
skala kg/cm2
1 34
P 2 36
U 3 36
K 4 36
U 5 36
L 6 36
A 7 36
N 8 36
9 38
10 38
R maksimum 38
R minimum 34
R rata-rata 36,20 347,58
Simpangan Baku 1,14
Koef. Variasi 3,14
2
Kuat Tekan Beton (kg/cm ) 344,02
Kuat Tekan Beton (MPa) 28,55
LABORATORIUM PENGUJIAN BETON & TANAH
Jl. Kamboja No.1902 Kel.20 Ilir D.III Palembang

DATA HAMMER-SCHMIDT TEST


ASTM C-805-02 / SNI 03-4430-1997

PROYEK : SUBAN COMPRESSION PROJECT


CLIENT : PT. TOTAL PERSADA INDONESIA
SITE : -
ALAT DIGUNAKAN : HAMMER MATEST 2P0435
LOKASI : SUBAN, CONOCOPHILLIPS
DITEST OLEH : AFLAHA
TANGGAL TEST : 08 Januari 2018

02 . A
K.O DRUM Tgl.cor -
RCP Ø 500 MM (Test 2) arah : -90o
skala kg/cm2
1 34
P 2 34
U 3 34
K 4 34
U 5 36
L 6 36
A 7 36
N 8 36
9 36
10 36
R maksimum 36
R minimum 34
R rata-rata 35,20 381,68
Simpangan Baku 1,03
Koef. Variasi 2,93
2
Kuat Tekan Beton (kg/cm ) 378,65
Kuat Tekan Beton (MPa) 31,43
LABORATORIUM PENGUJIAN BETON & TANAH
Jl. Kamboja No.1902 Kel.20 Ilir D.III Palembang

DATA HAMMER-SCHMIDT TEST


ASTM C-805-02 / SNI 03-4430-1997

PROYEK : SUBAN COMPRESSION PROJECT


CLIENT : PT. TOTAL PERSADA INDONESIA
SITE : -
ALAT DIGUNAKAN : HAMMER MATEST 2P0435
LOKASI : SUBAN, CONOCOPHILLIPS
DITEST OLEH : AFLAHA
TANGGAL TEST : 08 Januari 2018

02 . B
K.O DRUM Tgl.cor -
RCP Ø 500 MM (Test 2) arah : 0o
skala kg/cm2
1 34
P 2 34
U 3 34
K 4 34
U 5 36
L 6 36
A 7 36
N 8 38
9 38
10 38
R maksimum 38
R minimum 34
R rata-rata 35,80 341,22
Simpangan Baku 1,75
Koef. Variasi 4,89
2
Kuat Tekan Beton (kg/cm ) 332,65
Kuat Tekan Beton (MPa) 27,61

Anda mungkin juga menyukai