Anda di halaman 1dari 5

STRUKTUR PONDASI

JURUSAN TEKNIK SIPIL


POLITEKNIK NEGERI SRIWIJAYA
Jln. Srijaya Negara, Palembang 30139
Telp. 0711-353414 Fax. 0711-355918 Email. Info@mail.polsriwijaya.ac.id

Nama : Azizul Ilham Pratama


Kelas : 5SD
NIM : 061530100760

TUGAS STRUKTUR PONDASI

1. Diketahui data tanah sebagai berikut :


2
ɣm = 18,8 Kn/m3, Ø = 30°, C = 3,85 Kn/m2, q ult = 920 Kn/m2, δ = 5Ø, ɣb = 24 Kn/m3

Ditanya :
1. Faktor Keamanan terhadap geser
2. Faktor Keamanan terhadap guling
3. Faktor Keamanan terhadap daya dukung

A. Mencari nilai G dan XG

7
G1 = 24 x 1,166 x 2 = 97,944 Kn/m
G2 = 24 x 2,959 x 7 = 497,112 Kn/m
7
G3 = 24 x 0,875 x 2 = 73,5 Kn/m
ƩG = 668,556 Kn/m

Struktur Pondasi
Azizul Ilham Pratama (061530100760)
STRUKTUR PONDASI
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI SRIWIJAYA
Jln. Srijaya Negara, Palembang 30139
Telp. 0711-353414 Fax. 0711-355918 Email. Info@mail.polsriwijaya.ac.id

2
X1 = 3 x 1,166 = 0,777 m
1
X2 = 1,166 + 2 2,959 = 2,645 m
1
X3 = 1,166 + 2,959 + 3 x 0,875 = 4,416 m

𝐺1.𝑥1+𝐺2.𝑥2+𝐺3.𝑥3 (97,944𝑥0,777)+(497,112𝑥2,645)+(73,5𝑥4,416)
XG = Ʃ𝐺
= 668,556
= 2,566

Ø = 30°, δ = 12°, β = 18°, α = 7°7’30,06”

𝐶𝑜𝑠2 (Ø+𝛼)
Kah = sin(Ø+𝛿)𝑆𝑖𝑛(Ø−𝛽)
= 0,332875199 ~ 0,333
𝐶𝑜𝑠2 𝛼[ 1+ √
cos(𝛼−𝛿)cos(𝛼+𝛽)

B. Diagram tekanan tanah

Pq = q x Kah = 10 x 0,333 = 3,33 Kn/m2


Pz = ɣm x H x Kah = 18,8 x 7 x 0,333 = 43,823 Kn/m2
Pc = -2c √𝐾𝑎ℎ = -2 x 3,83 x √0,333 = -4,443 Kn/m2
Pq’= Pq x H = 3,33 x 7 = 23,31 Kn/m
1 1
Pz’ = 2 x Pz x H = 2 x 43,823 x 7 = 153,380 Kn/m
Pc’ = Pc x H = -4.443 x 7 = -31,101 Kn/m

Struktur Pondasi
Azizul Ilham Pratama (061530100760)
STRUKTUR PONDASI
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI SRIWIJAYA
Jln. Srijaya Negara, Palembang 30139
Telp. 0711-353414 Fax. 0711-355918 Email. Info@mail.polsriwijaya.ac.id

C. Menghitung Ph dan Yh

Ph = Pq’ + pz’ – Pc’ = 23,31 + 153,380 – 31,101 = 145,589 Kn/m


1
𝑃𝑞′ .𝑦𝑞+𝑃𝑧 ′ .𝑦𝑧−𝑃𝑐 ′ 𝑦𝑐 (23,31𝑥3,5)+(153,80 𝑥 𝑥7)−(31,101𝑥3,5)
3
Yh = 𝑃ℎ
= 145,589
= 2,27 m
Mg = Ph x yh = 145,589 x 2,27 = 330,487 Kn m/m

D. Menghitung Pv dan Xv
Pv/Ph = tan(α+δ)
Pv = Ph x tan(α+δ)
= 145,589 x tan (7°7’30,06” + 12°)
= 50,486 Kn/m
𝑦ℎ 2,27
Xv= 5 – 8
=5- 8
= 4,716

E. Kontrol FK geser
Ʃ(𝐺+𝑃𝑣)𝑡𝑎𝑛𝛿 Ʃ(668,556+50,486)𝑡𝑎𝑛12
Ʃ𝑃ℎ
= 145,589
= 1,049 < 1,5 Not Oke

F. Kontrol FK guling
Mt = ƩG. XG + Pv.Xv = 668,556 x 2,566 + 50,486 x 4,716 = 1953,606 Knm/m
𝑀𝑡 1953,606
Fk Guling = 𝑀𝑔 = 330,487
= 5,911 > 1,50 Oke

G. Kontrol Daya Dukung

Struktur Pondasi
Azizul Ilham Pratama (061530100760)
STRUKTUR PONDASI
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI SRIWIJAYA
Jln. Srijaya Negara, Palembang 30139
Telp. 0711-353414 Fax. 0711-355918 Email. Info@mail.polsriwijaya.ac.id

𝑀𝑡 𝐵 1953,606 5
X = Ʃ𝑉 - 2 = (668,556+50,486) - 2
= 0,217 m

My = vx – mg
= 719,042 x 0,217 – 330,487 = -174,454 Knm/m
A = 5m2
1 𝑥 52
Wy = 10
= 2,5
Ʃ𝑣 𝑀𝑥 𝑀𝑦
q= ± ±
𝐴 𝑊𝑥 𝑊𝑦
719,042 −174,454
q= ±0±
5 2,5
q maks =213,59 Kn/m2 q min = 89,718 Kn/m2

𝑞𝑢𝑙𝑡 920
Fk daya dukung = 𝑞𝑚𝑎𝑘𝑠 =213,59 = 4,307 > 2,50 Oke

Struktur Pondasi
Azizul Ilham Pratama (061530100760)
STRUKTUR PONDASI
JURUSAN TEKNIK SIPIL
POLITEKNIK NEGERI SRIWIJAYA
Jln. Srijaya Negara, Palembang 30139
Telp. 0711-353414 Fax. 0711-355918 Email. Info@mail.polsriwijaya.ac.id

Struktur Pondasi
Azizul Ilham Pratama (061530100760)

Anda mungkin juga menyukai