Pump Capacity = 0,000243 x D2 x L x efisiensi pompa = 0,000243 x (4”)2 x (15”) x 70% = 0,040824
2. Perhitungan Lag Down
• Volume bagian dalam pipa Volume Pipa (bbl) = (IDDP2 / 1029,4) x panjang pipa = ((4”)2 / 1029,4) x 14000 ft = 217,6024869 inch2 ft
• Volume bagian dalam collar
Volume Collar (bbl) = (IDDC2 / 1029,4) x panjang collar = ((2,5”)2 / 1029,4) x 500 ft = 3,03574898 inch2 ft
• Nilai Lag Down
Lag Down = (Volume pipa + Volume collar) / (Pump Capacity x SPM) = ( 217,6024869 inch2 ft + 3,03574898 inch2 ft) / (0,040824 x 67) = 80,66598075 menit
3. Perhitungan Lag Up dan Lag Total
• Volume Annulus Drill Collar Volume Annulus DC (bbl) = ((DH2 – ODDC2) / 1029,4) x panjang drill collar = ((8”)2 – (4,8”)2) / 1029,4 x 500 ft = 19,89508452 inch2 ft
• Volume Annulus Pipa dengan Casing
Volume Annulus DP (dengan casing) (bbl) = ((IDCSG2 – ODDP2) / 1029,4) x panjang pipa dengan casing = (((10”)2 – (4,5”)2) / 1029,4) x 8000 ft = 619,7785118 inch2 ft
• Volume Annulus Pipa tanpa Casing
Volume Annulus DP (tanpa casing) (bbl) = ((DH2 – ODDP2) / 1029,4) x panjang pipa tanpa casing = (((8”)2 – (4,5”)2) / 1029,4) x 6000 ft = 255,0029143 inch2 ft
• Nilai Lag Up Lag Up = Volume Annulus Total / (Pump Capacity x SPM) = (19,8950+ 619,7785 + 255,0029) inch2 ft / (0,0408 x 67) = (894,6764 inch2 ft) / (2,7336) = 327,2887 menit
• Nilai Lag Total
Lag Total = Lag Down + Lag Up = 80,6659 menit + 327,2887 menit = 407,9546 menit ≈ 6 jam + 47 menit + 57,276 detik