SPESIFIKASI FERROCEMENT SPESIFIKASI MORTAR SPESIFIKASI KAWAT

hfc 25 mm f cm 25 Mpa Jenis Segienam


Nw 6 lapis Em 23500 MPa nw 0.45
Ɛ um 0.007 dw 0.7
h deck 25 mm f tm 3.1 Mpa DL 12.5
DT 12.5
f yw 490
Ɛ uw 0.015
Ew 210000
VOLUME FRAKSI TULANGAN
Vf 0.0148
Vs 0.0113
Vfr 0.0245
Vm 0.9755

MODULUS ELASTISITAS KOMPOSIT/FERROCEMENT


Ec 25238.22

PERMUKAAN SPESIFIK
SL 0.0845
KUAT RETAK PENAMPANG
σ cr 5.1698
MODULUS RETAK
E cr 2313.545
REGANGAN RETAK
Ɛ cr 0.002235

TINJAUAN TERHADAP TARIK TINJAUAN TERHADAP TEKAN


σ tu = σ ty 11.99616 σ cu σ cy 20.72976
Ɛ ty 0.005185 Ɛ cy 0.000821
Ɛ tu 0.015 Ɛ cu 0.007

KAPASITAS MOMEN NOMINAL


Mn 5335.866 Mpa

MENCARI NILAI X
x 7.954545

xcy 0.933368
xty 5.892256
xcr 2.539275

C1 14554.73 CHECKING
C2 967.4246 C = T
T1 656.3721 C1+C2 = T1+T2+T3 C-T=0
T2 2877.85 15522.16 = 16913.78 KOREKSI = -1391.622
T3 13379.56
UBAH NILAI X

NILAI X
x 8.427305

xcy 0.98884
xty 5.728833
xcr 2.468848

C1 15419.76 CHECKING
C2 1024.921 C = T
T1 638.1675 C1+C2 = T1+T2+T3 C-T=0
T2 2798.032 16444.68 = 16444.67 KOREKSI = 0.008179
T3 13008.47
TULANGAN
ds 6 b 100 mm
Ss 100 mm
mm Fys 420 Mpa b deck 100 mm
mm
mm
mm

Mpa

KARENA NILAI T TIDAK = C MAKA DIUBAH NILAI X


NYA