Anda di halaman 1dari 237

SPESIFIKASI TEKNIS

PEMBANGUNAN SARANA PUSAT DATA DAN REVITALISASI INFRASTRUKTUR


TEKNOLOGI INFORMASI DAN KOMUNIKASI

LEMBAGA PERLINDUNGAN SAKSI DAN KORBAN


TAHUN ANGGARAN 2022

1
Daftar Isi

Daftar Isi ........................................................................................................................................................ 2


1. Latar Belakang ........................................................................................................................................... 5
2. Maksud dan Tujuan................................................................................................................................... 7
3. Dasar Hukum ............................................................................................................................................. 7
4. Kualifikasi Penyedia................................................................................................................................... 8
5. Ruang Lingkup Kegiatan .......................................................................................................................... 10
5.1 Pembangunan Data Center dan Command Center ............................................................................ 11
5.2 Menyediakan perangkat infrastruktur jaringan.................................................................................. 12
5.3 Pembangunan Ruang Sidang Mahkamah Pimpinan .......................................................................... 12
5.4 Pembangunan Ruangan Sidang Saksi ................................................................................................... 13
5.5 Menyediakan sistem Keamanan Gedung LPSK ................................................................................... 13
5.6 Renovasi Pos Keamanan......................................................................................................................... 14
5.7 Menyediakan Mobile Witness Room ................................................................................................... 14
5.8 Menyediakan aplikasi mobile sistem Manajemen Kasus Saksi dan Korban ................................... 14
5.9 Menyediakan pelatihan/capacity building .......................................................................................... 14
5.10 Menyediakan alat pengolah data ......................................................................................................... 14
5.11 Menyediakan layanan managed services ............................................................................................ 15
5.12 Menyediakan sistem Videotron di Office Hall LPSK ........................................................................... 15
6. Spesifikasi Teknis..................................................................................................................................... 15
6.1 Spesifikasi teknis pengembangan Data Center ..................................................................................... 15
6.1.1 Pekerjaan Sipil ......................................................................................................................... 16
6.1.2 Pekerjaan Sistem Kelistrikan ................................................................................................... 25
6.1.3 UPS modular ........................................................................................................................... 32
6.1.4 Genset dan Rumah Genset ..................................................................................................... 35
6.1.5 Sistem Pencegah Kebakaran (Fire Supression System) ........................................................... 81
6.1.6 Sistem Pendingin Presisi ........................................................................................................ 85
6.1.7 Infrastruktur Pendukung data center dan Comand Center .................................................... 88
6.2 Spesifikasi Teknis perangkat Infrastruktur jaringan ........................................................................... 94
6.2.1 Core Switch ............................................................................................................................. 94
6.2.2 Access Switch non PoE ............................................................................................................ 95
6.2.3 Access Switch PoE ................................................................................................................... 96
6.2.4 Wireless Access point.............................................................................................................. 96

2
6.2.5 Wireless Controller ................................................................................................................. 97
6.2.6 Server Farm Firewall ............................................................................................................... 98
6.2.7 Internet Firewall ...................................................................................................................... 99
6.2.8 Top Of Rack (TOR) Switch ..................................................................................................... 100
6.2.9 Management Switch ............................................................................................................. 101
6.2.10 SDWAN Router Kantor Pusat ............................................................................................ 102
6.2.11 SDWAN Router Rumah Aman ........................................................................................... 103
6.2.12 Email Security .................................................................................................................... 104
6.2.13 Load Balancer&WAF ......................................................................................................... 105
6.2.14 Network & Application Performance Monitoring............................................................. 106
6.2.15 Bandwidth Management .................................................................................................. 106
6.2.16 Sistem Operasi .................................................................................................................. 107
6.2.17 Software management Virtualisasi ................................................................................... 107
6.2.18 Server Virtualisasi.............................................................................................................. 107
6.2.19 SAN Switch ........................................................................................................................ 108
6.2.20 SAN Storage and expansion Enclosure ............................................................................. 109
6.2.21 Cabling System .................................................................................................................. 109
6.2.22 Lisensi Pendukung aplikasi ................................................................................................ 111
6.2.23 SDWAN Router perwakilan daerah ................................................................................... 111
6.2.24 Access Switch perwakilan daerah ..................................................................................... 112
6.2.25 SDWAN Router Mobile Witness Room ............................................................................. 113
6.3 Spesifikasi Teknis Ruang Sidang Mahkamah Pimpinan (Paripurna) ............................................. 114
6.4 Spesifikasi Teknis Ruang Sidang Saksi ................................................................................................ 123
6.5 Spesifikasi Teknis Infrastruktur sistem security gedung LPSK ........................................................ 131
6.5.1 Spesifikasi Sistem CCTV LPSK ................................................................................................ 131
6.5.2 Spesifikasi Teknis Automations Sliding Gate......................................................................... 178
6.5.3 Spesifikasi Teknis Rising Bollard ............................................................................................ 181
6.5.4 Spesifikasi Under Vehicle Inspection System ........................................................................ 184
6.5.5 Spesifikasi X-ray Scanner....................................................................................................... 189
6.5.6 Spesifikasi Walk Through Metal Detector............................................................................. 194
6.5.7 Spesifikasi Access Control System......................................................................................... 200
6.5.8 Spesifikasi Teknis Perangkat pendukung komunikasi ........................................................... 212
6.7 Spesifikasi teknis renovasi Pos Keamanan ........................................................................................ 214
6.8 Spesifikasi teknis Mobile Witness Room ........................................................................................... 217
6.9 Spesifikasi Teknis sistem Manajemen Kasus Saksi dan Korban ...................................................... 220

3
6.9.1 Spesifikasi Umum Sistem ...................................................................................................... 220
6.9.2 Spesifikasi Fungsional Sistem ................................................................................................ 221
6.10 Spesifikasi Teknis alat pengolah Data ................................................................................................ 225
6.11 Spesifikasi Teknis Managed Service.................................................................................................... 226
6.12 Spesifikasi Teknis Videotron Office Hall ............................................................................................. 226
7. Daftar Kuantitas .................................................................................................................................... 230
8. Kualifikasi Tenaga Ahli........................................................................................................................... 233
9. Pelaporan .............................................................................................................................................. 236
10. Lokasi kegiatan .................................................................................................................................... 237
11. Jangka Waktu pelaksanaan Kegiatan .................................................................................................. 237

4
1. Latar Belakang
a) Inisiatif pelaksanaan Sistem Pemerintahan Berbasis Elektronik, yang selanjutnya
disingkat SPBE, yang dicanangkan oleh Pemerintah Pusat yang ditujukan untuk
mewujudkan proses kerja yang aman, efisien, efektif, transparan, dan akuntabel serta
meningkatkan kualitas pelayanan publik. Untuk mendukung pelaksanaan SPBE di
Lembaga Perlindungan Saksi dan Korban, maka perlu dilakukan Revitalisasi Pusat Data
dan Sarana Infrastruktur Teknologi Informasi dan Komunikasi LPSK.

b) Perkembangan Teknologi Informasi dan Komunikasi terkini dengan maraknya sistem


Work From Home, meningkatnya penggunaan aplikasi berbasis web dan “mobile
application” membutuhkan sarana infrastruktur TIK yang memiliki kapasitas besar dan
kecepatan akses yang tinggi

c) Meningkatnya ancaman keamanan sistem teknologi informasi yang semakin canggih


dan terstruktur mengancam keamanan data pengguna, untuk itu dibutuhkan perangkat
keamanan teknologi informasi yang mampu mencegah dan mengatasi ancaman
keamanan sistem teknologi informasi tersebut.

d) Dengan adanya PEMBANGUNAN SARANA PUSAT DATA DAN REVITALISASI


INFRASTRUKTUR TEKNOLOGI INFORMASI DAN KOMUNIKASI, maka setiap kegiatan akan
terpantau, ter- monitoring dan setiap data akan tersimpan dengan aman, perangkat
yang "bermasalah" akan diketahui dengan mudah tanpa harus visit.

e) Akses data, pertukaran data, dan proses komunikasi antar lokasi dengan aman dapat
difasilitasi dengan baik karena sudah dilindungi dengan network security. Dengan
demikian data dan komunikasi di lingkungan LPSK dapat terjaga dan terjamin dengan
baik.

f) Oleh sebab itu PEMBANGUNAN SARANA PUSAT DATA DAN REVITALISASI


INFRASTRUKTUR TEKNOLOGI INFORMASI DAN KOMUNIKASI sebagai bagian dari
infrastruktur digital untuk mendukung pemerintahan digital, ekonomi digital dan
masyarakat digital menjadi penting.

Kondisi Saat Ini


Kondisi Pusat Data dan Sarana Teknologi Informasi dan Komunikasi LPSK saat ini dapat di
deskripsikan sebagai berikut :

5
a) Ruang Pusat Data LPSK dan sarana pendukung yang ada saat ini kurang memadai
untuk mengakomodasi penambahan kapasitas rack server, penambahan kapasitas
sistem pendingin dan UPS
b) Access Switch Yang terhubung ke end user menggunakan switch dengan kecepatan
100 Mbps dan tidak memiliki support dan service yang aktif, jika terjadi kerusakan
tidak akan mendapatkan support dari principal penyedia perangkat
c) Jaringan nirkabel / wireless yang digunakan bersifat autonomous/stand alone yang
relative susah di kelola. tidak memiliki support dan service yang aktif, jika terjadi
kerusakan tidak akan mendapatkan support dari principal penyedia perangkat
d) Server-server yang digunakan sudah ketinggalan dari sisi teknologi dengan kapasitas
hardware yang kurang memadai. Server juga tidak memiliki support dan service yang
aktif, jika terjadi kerusakan tidak akan mendapatkan support dari principal penyedia
perangkat
e) service & subscription pada perangkat keamanan (firewall) yang digunakan sudah
expired sehingga tidak mampu mencegah dan mengimbangi ancaman keamanan
teknologi informasi terbaru
f) Infrastruktur keamanan gedung yang belum memadai dan belum dapat
merepresentasikan LSPK sebagai lembaga yang menjamin keamanan saksi dan korban
g) LPSK belum memiliki aplikasi terintegrasi yang dapat melayani terlindung dari mulai
mengajukan permohonan perlindungan secara online, monitoring kasus, monitoring
kondisi terlindung dan lainnya yang dapat di akses secara mudah dari platform mobile.

6
2. Maksud dan Tujuan
Perpres no 95/2018 tentang SPBE dan perpres no 39/2019 tentang satu data indonesia
menunjukkan pentingnya Pusat Data yang terstandarisasi Internasional untuk mendukung
kepentingan pemberian layanan TIK secara Nasional, untuk itu pembangunan Pusat Data
LPSK harus mengacu pada standar internasional uptime institute TIER III dan dapat
dikembangkan secara bertahap untuk mencapai standar yang dapat memenuhi persayaran
menjadi bagian dari pusat data nasional.
Tujuan d a r i Pengadaan pembangunan Pusat Data dan Revitalisasi Infrastruktur Teknologi
Informasi dan Komunikasi LPSK adalah:
a) Tersedianya Pusat Data yang memenuhi Standar Internasional dan sarana
command center sebagai pusat komando kegiatan LPSK
b) Tersedianya Sarana Infrastruktur Teknologi Informasi dan Komunikasi yang
mendukung aplikasi layanan publik dan mobile app yang cepat, aman dan efektif
c) Tersedianya ruang rapat mahkamah pimpinan yang representative dan fungsional
d) Tersedianya ruang sidang
e) Tersedianya infrastruktur sistem keamanan gedung LPSK
f) Tersedianya mobile witness room (mobil van)
g) Tersedianya aplikasi mobile sistem manajemen kasus saksi dan korban
h) tersedianya notebook sebagai alat pengolah data sebagai perangkat penunjang
pekerjaan karyawan LPSK
i) Tersedianya layanan managed service untuk mendukung operasional layanan TIK
di LPSK

3. Dasar Hukum
Dasar hukum pelaksanaan pengadaan Revitalisasi Infratruktur informasi teknologi LPSK
tahun Anggaran 2022 adalah sebagai berikut:
a) Undang-Undang Republik Indonesia Nomor 14 Tahun 2008 tentang Keterbukaan
Informasi Publik;
b) Undang-Undang Republik Indonesia Nomor 25 Tahun 2009 tentang Pelayanan
Publik;

7
c) Peraturan Presiden Nomor 95 Tahun 2018 tentang Penerapan Sistem
Pemerintahan Berbasis Elektronik (SPBE);
d) Peraturan Presiden Nomor 16 Tahun 2018 tentang Pengadaan Barang/Jasa
Pemerintah sebagaimana telah diubah terakhir dengan Peraturan Presiden
Republik Indonesia Nomor 12 Tahun 2021 Tentang Perubahan Atas Peraturan
Presiden Nomor 16 Tahun 2018 Tentang Pengadaan Barang/Jasa Pemerintah.
e) Peraturan Presiden Nomor 39 Tahun 2019 tentang Satu Data Indonesia;
f) Keputusan Ketua Lembaga Perlindungan Saksi Dan Korban Nomor Kep-
241/I.Div2.7/Lpsk/Vii/2013, Tentang Petunjuk Teknis Pelaksanaan Peraturan
Lembaga Perlindungan Saksi Dan Korban Nomor 2 Tahun 2011 Tentang Standar
Operasional Prosedur Pelayanan Informasi Publik Di Lingkungan Lembaga
Perlindungan Saksi Dan Korban
g) Peraturan Lembaga Kebijakan Pengadaan Barang/Jasa Nomor 12 Tahun 2021
tentang Pedoman Pelaksanaan Pengadaan Barang/Jasa Melalui Penyedia;
h) Peraturan Komisi Informasi Republik Indonesia Nomor 1 Tahun 2021 tentang
Standar Layanan Informasi Publik;
i) Peraturan Lembaga Perlindungan Saksi Dan Korban Nomor 2 Tahun 2011, Tentang
Standar Operasional Prosedur Pelayanan Informasi Publik Di Lingkungan Lembaga
Perlindungan Saksi Dan Korban

4. Kualifikasi Penyedia
Penyedia barang dan jasa harus memiliki kriteria sebagai berikut:
a. Penyedia merupakan Badan Usaha yang memiliki klasifikasi Non Kecil dengan
kode Klasifikasi Baku Lapangan Usaha Indonesia (KBLI) 4651 (Perdagangan Besar
Komputer, Perlengkapan Komputer dan Piranti Lunak); KBLI 4652 (Perdagangan
Besar Suku Cadang Elektronik dan Peralatan Telekomunikasi dan Bagian-
bagiannya; KBLI 62019 (Aktivitas Pemprograman Komputer lainnya); kode KBLI
6202 (Kegiatan Konsultasi Komputer dan Manajemen Fasilitas Komputer);
b. Penyedia memperoleh dukungan untuk mengikuti kegiatan pengadaan ini dari
prinsipal resmi perangkat Jaringan, Keamanan Jaringan, load balancer, Server dan
Storage yang memiliki kantor perwakilan resmi di Indonesia, dibuktikan dengan
Surat Dukungan dari prinsipal/pabrikan dari negara asal;
c. Penyedia memperoleh dukungan untuk mengikuti kegiatan pengadaan ini dari
prinsipal atau distributor resmi perangkat infrastruktur system security Gedung,

8
Bandwitdh Management, yang dibuktikan dengan Surat Dukungan dari
prinsipal/Distributor;
d. Penyedia merupakan partner / rekanan dari prinsipal resmi perangkat Jaringan,
Keamanan Jaringan, load balancer, Server dan Storage yang di buktikan dengan
sertifikat partnership atau surat penunjukan partner dari prinsipal
e. Penyedia memiliki tenaga ahli yang merupakan warga negara Republik Indonesia
dengan kualifikasi seperti yang terdapat dalam bagian kualifikasi tenaga ahli
dengan melampirkan Daftar riwayat hidup, KTP, Ijazah, sertifikasi keahlian sesuai
dengan bidangnya dan NPWP yang masih berlaku;
f. Penyedia mempunyai status valid keterangan Wajib Pajak berdasarkan Konfirmasi
Status Wajib Pajak sesuai Peraturan LKPP Nomor 12 Tahun 2021 tentang
Pedoman Pelaksanaan Pengadaan Barang/Jasa Pemerintah Melalui Penyedia;
g. Penyedia/leading firm pada perusahaan yang melakukan KSO pernah memiliki
pengalaman dengan nilai pekerjaan sejenis (KBLI) dalam kurun waktu 2 (dua)
tahun terakhir paling kurang sama dengan 50% (lima puluh persen) nilai total HPS
yang dibuktikan dengan dokumen kontrak pekerjaan dan BAST terkait;
h. Memiliki pengalaman menyediakan barang pada divisi yang sama paling kurang 1
(satu) pekerjaan dalam kurun waktu 1 (satu) tahun terakhir baik di lingkungan
pemerintah maupun swasta, termasuk pengalaman subkontrak;
i. Memiliki pengalaman menyediakan barang sekurang-kurangnya dalam
kelompok/grup yang sama paling kurang 1 (satu) pekerjaan dalam kurun waktu 3
(tiga) tahun terakhir baik di lingkungan pemerintah maupun swasta, termasuk
pengalaman subkontrak;
j. Dalam hal ditetapkan sebagai pemenang, penyedia barang wajib menandatangani
Kesepakatan Kewajiban Menjaga Rahasia;
k. Penyedia memiliki sertifikasi Internasional Standard Organization untuk kategori:

 ISO 9001:2015 (Quality Management System)


 ISO 45001:2018 (Occupational Health & Safety Management System)
 ISO 27001:2013 (Information Security Management System)

9
l. Penyedia yang melakukan kemitraan/KSO harus sebagai leading firm dengan
pembagian modal mayoritas (minimal 51%) dengan melampirkan perjanjian
kemitraan/kerja sama operasi yang memuat persentase kemitraan/KSO;
m. Penyedia wajib memberikan perhitungan TKDN minimal 25% (dua puluh lima persen)
atas Produk Dalam Negeri dan dilampirkan dalam dokumen penawaran;
n. Pekerjaan konstruksi (Sipil) Penyedia wajib mensubkontrakan kepada sub penyedia
jasa usaha kualifikasi non kecil dengan ketentuan memiliki SBU Kualifikasi Bangunan
Gedung (BG009 Jasa Pelaksana Konstruksi Bangunan Gedung Lainnya atau (BG004
Jasa Pelaksana Konstruksi Bangunan Komersial) dan mendapatkan dukungan dari
kontraktor serta dilampirkan sertifikat SBU dan SIUJK dalam dokumen penawaran;
o. Pekerjaan Pengadaan Mobile Witness Room Penyedia wajib mensubkontrakan
kepada sub penyedia jasa usaha sesuai dengan KBLI 29101 atau KBLI 29200.

5. Ruang Lingkup Kegiatan


Penyedia barang dan jasa harus memenuhi ruang lingkup kegiatan sebagai berikut :
1) Melakukan pembangunan Data Center dan Command Center LPSK
2) Menyediakan Perangkat infrastruktur jaringan, keamanan jaringan beserta
instalasinya di LPSK pusat dan perwakilan daerah
3) Melakukan renovasi ruang Sidang Mahkamah Pimpinan
4) Melakukan renovasi ruang sidang saksi
5) Menyediakan Infrastruktur sistem security gedung LPSK
6) Melakukan renovasi Pos Keamanan gerbang LPSK
7) Menyediakan mobile witness room
8) Menyediakan aplikasi sistem Manajemen Kasus Saksi dan Korban
9) Melakukan pelatihan / capacity building untuk setiap solusi, sistem dan barang
yang di sediakan
10) Menyediakan alat pengolah data (note book)
11) Menyediakan managed service selama 1 tahun beserta peralatan kerja
pendukung ( PC/notebook, printer )
12) Menyediakan videotron Office Hall LPSK

10
5.1 Pembangunan Data Center dan Command Center
Penyedia barang dan jasa wajib melakukan Kegiatan pembangunan Data Center
dan command center LPSK dengan ruang lingkup meliputi :
a) Pekerjaan Sipil/Interior
Melaksanakan pekerjaan sipil pembangunan ruangan data center dan
command center serta interior yang memenuhi standart dan mengikuti
kaidah/aturan-aturan dari gedung LPSK
b) Sistem Kelistrikan
Membangun instalasi sistem kelistrikan melalui power house baru yang
diperuntukan khusus untuk supply listrik data center sesuai dengan
Standarisasi Tier III, instalasi pada command center, ruang rapat mahkamah
pimpinan, ruang sidang dan lokasi lainnya yang di butuhkan dan tersebut
dalam kegiatan ini. Kebutuhan daya listrik yang diperlukan untuk mendukung
kegiatan pembangunan Data Center dan command center LPSK harus di
hitung agar sesuai dan cukup. Penyedia barang dan jasa wajib mendapatkan
sertifikasi laik operasi (SLO) dari PLN.

c) P
e
n
g
a
d
a
a
n

U
P
S

M
o
d
ular
Melakukan pengadaan & instalasi UPS modular di Data Center dengan
konfigurasi redundant
d) Pengadaan Genset dan rumah Genset

11
Melakukan pengadaan genset dan rumah genset sebagai sumber tenaga
listrik cadangan utama untuk data center.
e) Sistem Pencegah Kebakaran
Melakukan pemasangan Fire Suppression dengen sistem standar NFPA:2001
Standard on Clean Agent Fire Extinguishing Systems yang penempatannya
disesuaikan dengan kebutuhan ruangan Data Hall, Utility Room, MMR, serta
melakukan penataan ulang Springkler Existing di area Data Center.
f) Pekerjaan Sistem Pendinginan
Melakukan pemasangan 3 unit Precision Air Conditioning (PAC), yang saling
berkomunikasi antar PAC, dimana 2 unit aktif dan 1 unit stand by yang
bekerja secara bergantian.
g) Pekerjaan infrastuktur pendukung Data Center dan Command Center
Melakukan pengadaan dan pemasangan Videowall Command Center dan
NOC, EMS dan Rack Server/Network.

Penyedia barang dan jasa diwajibkan untuk melakukan user acceptance test
terhadap instalasi perangkat / layanan yang telah dilaksanakan.

5.2 Menyediakan perangkat infrastruktur jaringan


Penyedia barang dan jasa wajib menyediakan perangkat infrastruktur jaringan
beserta instalasinya sesuai dengan spesifikasi teknis yang disyaratkan dan, dalam
hal diwajibkan oleh peraturan yang berlaku, telah mendapatkan sertifikasi dari
lembaga yang berwenang.
Penyedia wajib melakukan migrasi sistem dan data yang ada di Data Center
existing ke Data center baru dengan memperhatikan aspek down time, dan
keamanan data yang akan di migrasi.
Penyedia diwajibkan untuk melakukan user acceptance test terhadap instalasi
perangkat / layanan yang telah dilaksanakan
5.3 Pembangunan Ruang Sidang Mahkamah Pimpinan
Penyedia wajib melakukan pembangunan Ruang Sidang Mahkamah Pimpinan LPSK
di lantai 4, sesuai dengan spesifikasi teknis yang disyaratkan.
Lingkup pekerjaan ini meliputi :
 Pengadaan Ruang Sidang Mahkamah Pimpinan LPSK lengkap dengan
furniture dan interiornya Serta Sistem Audio.
 Pengadaan Videowall.
 Pekerjaan Struktur dan Backdrop Videowall.
 Terdapat Ruangan Istirahat Pimpinan.

12
 Pekerjaan kelistrikan dan penerangan harus mengikuti peraturan dan
ketentuan yang berlaku.

5.4 Pembangunan Ruangan Sidang Saksi


Penyedia wajib melakukan renovasi Ruangan Sidang sesuai dengan spesifikasi
teknis yang disyaratkan.
Lingkup pekerjaan ini meliputi:
 Pengadaan ruangan sidang saksi lengkap dengan furniture dan
interiornya Serta Audio System
 Pengadaan Videowall
 Pekerjaan Struktur dan Backdrop Videowall
 Pekerjaan kelistrikan dan penerangan harus mengikuti peraturan dan
ketentuan yang berlaku

5.5 Menyediakan sistem Keamanan Gedung LPSK


Penyedia wajib menyediakan sistem keamanan Gedung LPSK beserta instalasinya
sesuai dengan spesifikasi teknis yang disyaratkan. Infrastruktur sistem keamanan
gedung LPSK meliputi:
a) Pengadaan automatic gate
automatic gate menjaga gedung LPSK dari masuknya kendaraan yang tidak
memiliki otoritas dan mengamankan perimeter terluar dan memberikan
perlindungan anti teror.
b) Pengadaan rising bolard
rising bolard menjaga gedung LPSK dari masuknya kendaraan yang tidak
memiliki otoritas dan mengamankan perimeter dan memberikan
perlindungan anti teror.
c) Pengadaan Under Vehicle Inspection System
Under Vehicle Inspection System merupakan sistem yang berfungsi untuk
melakukan pengawasan / pemeriksaan terhadap bagian bawah kendaraan
dari bahan-bahan terlarang dan berbahaya secara otomatis. UVSS akan di
pasang pada ramp yang akan di lalui oleh kendaraan roda 4 yang akan
memasuki gedung LPSK.
d) Pengadaan X-Ray Scanner
X-Ray scanner berfungsi untuk memindai barang bawaan pengunjung dan
mencegah masuknya barang ilegal dan berbahaya ke lingkungan LPSK
e) Pengadaan Walk Through Metal Detector

13
Walk Through Metal Detector berfungsi untuk memindai pengunjung yang
melewatinya untuk mendeteksi benda mencurigakan berbahan metal
(misalnya senjata) yang dibawa oleh pengunjung.
f) Pengadaan Access Control System
Access Control berfungsi untuk mengelola akses masuk ke gedung LPSK.
pemasangan Access Control System gedung LPSK akan dikelompokkan
kedalam 3 bagian sebagai berikut:
1) Access System untuk automatic gate dan Rising Bollard
2) Access System untuk lift
3) Access System untuk Data Center dan Command Center
g) Pengadaan perangkat pendukung komunikasi berupa Handy Talkie dan Telepon
Satelit
Penyedia diwajibkan untuk melakukan user acceptance test terhadap instalasi
perangkat / layanan yang telah dilaksanakan.

5.6 Renovasi Pos Keamanan


Penyedia wajib melakukan renovasi ruangan Pos Keamanan gerbang LPSK
dengan spesifikasi yang disyaratkan.

5.7 Menyediakan Mobile Witness Room


Penyedia wajib menyediakan Mobile Witness Room sesuai dengan spesifikasi
teknis yang disyaratkan.

5.8 Menyediakan aplikasi mobile sistem Manajemen Kasus Saksi dan Korban
Penyedia wajib melakukan pengembangan aplikasi sistem Manajemen Kasus
Saksi dan Korban sesuai dengan spesifikasi teknis yang disyaratkan.

5.9 Menyediakan pelatihan/capacity building


Penyedia wajib melakukan pelatihan/transfer knowledge untuk setiap solusi,
sistem dan barang yang disediakan kepada tim LPSK yang ditunjuk dalam rangka
meningkatkan kapasitas/capacity building tim LPSK.

5.10 Menyediakan alat pengolah data


Penyedia wajib menyediakan alat pengolah data berupa notebook/laptop sesuai
dengan spesifikasi yang disyaratkan

14
5.11 Menyediakan layanan managed services
Penyedia wajib menyediakan kegiatan managed services selama 1 tahun dengan
menempatkan 2 orang engineer on site dengan kualifkasi yang di syaratkan
untuk membantu LPSK dalam melakukan pengelolaan operasional perangkat
jaringan.

5.12 Menyediakan sistem Videotron di Office Hall LPSK


Penyedia wajib menyediakan sistem Videotron Office Hall LPSK yang berlokasi di
aula lantai 6, sesuai dengan spesifikasi teknis yang disyaratkan.

6. Spesifikasi Teknis
Bagian spesifikasi teknis menggambarkan syarat-syarat teknis yang harus di penuhi oleh
setiap perangkat dan teknis pelaksanaan pekerjaan yang dilaksanakan dalam kegiatan ini.
6.1 Spesifikasi teknis pengembangan Data Center
Pengembangan Data Center LPSK harus mengacu pada gambar design Data Center
berikut:

Gambar Design Pengembangan Data Center LPSK

15
6.1.1 Pekerjaan Sipil
Pekerjaan sipil yang terdapat pada pembangunan data center meliputi:
1) Pembongkaran ruangan existing
Kegiatan pembongkaran ruangan existing harus memperhatikan aspek
keamanan, kebersihan dan kenyamanan pengguna di sekitar area
ruangan existing dan harus dikoordinasikan perijinan dan operasionalnya
dengan pengelola gedung.
2) Pemasangan dinding/partisi Data center
Spesifikasi Teknis:
a) Dinding bata ringan (Data Hall, Utility Room, MMR)
 Tebal bata ringan minimal 10cm
 Blok beton Hebel B-2, adukan pasir dan semen dengan
perbandingan 1:4, dan acian semen
 Adukan pemasangan Blok bata ringan dengan menggunakan
mortar khusus, yaitu semen instan :
 Untuk Pengikat antara Blok Hebel dengan lantai,
sloof, kolom praktis, ringbalk praktis menggunakan
PRIME MORTAR – PM 200 yaitu Ready Mix Plaster.
 Untuk Pengikat/Siar antara Blok Hebel menggunakan
PRIME MORTAR – PM 110 yaitu Thin Bed Mortar.
 Adukan untuk plesteran blok hebel menggunakan mortar
khusus, yaitu semen instan PRIME MORTAR – PM 210
yaitu Ready Mix Plaster.
 Adukan untuk acian menggunakan PRIME MORTAR – PM
310
 Plester dan acian dua sisi pada seluruh dinding bata ringan
b) Partisi Gipsum:
 Rangka : Rangka vertikal Metal Stud tebal 0,4mm.
Rangka horizontal atas dan bawah U Runner tebal 0,4mm.
 Penutup partisi: Digunakan Gypsum Board yang bermutu baik
tebal = 9 mm.
 Bahan penutup sambungan partisi: Compound, paper tape yang
berpori/berlubang dan bergaris tengah.

c) Partisi Kaca:

16
 Kaca 12 mm-tempered glass plus rangka alumunium

3) Pemasangan Plafon/Ceiling
Spesifikasi Teknis
a) Rangka:
 Rangka besi hollow galvanis 4 x 4 cm/2 x 4 cm, tebal pelat besi
hollow minimal 0,35 mm.
b) Penutup langit-langit:
 Gypsum Board yang bermutu baik produk Jayaboard/Knauf
atau produk lain yang setara, tebal = 9mm.
 Cover lighting dengan drop ceiling tebal 10mm
c) Bahan penutup sambungan plafond:
 Compound atau bahan plester ex UB400 atau produk lain yg
setara. Dan paper tape yang berpori/berlubang dan bergaris
tengah.

Penyedia juga harus menyediakan manhole/access panel ukuran 60x60


cm di langit langit yang bisa dibuka, diberi engsel tanpa merusak gypsum
board disekelilingnya, untuk keperluan pemeriksaan/pemeliharaan M & E
di lokasi yang di tentukan.

4) Pintu dan jendela


a. Pintu Besi dua daun
Spesifikasi teknis :
 Kusen & Pintu besi double plat 2mm + handle + kunci, 1,6 x
2.2 mtr
 Tahan api sesuai SNI 03 – 1736 - 2000
 Kaca intip tempered 20cm x 60cm (vertikal)
 Warna krem
b. Pintu Besi satu daun
Specifikasi teknis :
 Kusen & Pintu besi double plat 2mm + handle + kunci, 0,9 x
2.2 mtr
 Tahan api sesuai SNI 03 – 1736 - 2000
 Kaca intip tempered 20cm x 60cm (vertikal)
 Warna krem
c. Pintu kaca geser
Specifikasi teknis:

17
 Pintu kaca frame aluminium
 Kusen aluminium putih
 Sticker es
 door closer pintu sliding geser pegas
d. Jendela NOC
Specifikasi teksnis:
 Kusen aluminium
 Tempered glass 12 mm
 Ukuran 1m x 2m (Tinggi x lebar)
5) Pekerjaan pemasangan Raise Floor
Spesifikasi Teknis
a) Ketinggian raise floor dari lantai adalah 40 cm
b) Di lengkapi dengan ramp
c) Dilengkapi dengan isolasi lantai
d) Spesfikasi raise floor:
 mempunyai ISO 9001,14001, KS, CE Certification
 Type: Calcium Sulphate
 Modul: 600 x 600 x 30 mm
 Finishing: HPL - Anti Static
 Colour: White – Grey
 Kekuatan beban merata : Min 1700 kg/m2
 Kekuatan beban terpusat : Min 550 kg
 Ketinggian : 40 cm
 Ramp Ukuran Disesuaikan dengan pintu/Lay out
 Insulasi armaflex + Alumunium Foil

Volume Pekerjaan

a) Volume pekerjaan sipil Data Center

No DESKRIPSI JML UNIT


1 CIVIL & INTERIOR DATA CENTER
1.1 CIVIL WORK
1.1.2 Data Center & Monitoring
1.1.2.1 Room Clearance
Pek. Pembongkaran Dinding Eksisting 181 m2
Pek. Pembongkaran Pintu Exsisting 6 bh
Pek. Pengangkutan Sisa Bongkaran 1 ls

18
Relokasi Furnitur (dalam gedung) 1 ls
Pekerjaan plafon akustik 56 m2
Pekerjaan plafon gypsum 32 m2
Pekerjaan Dinding bata ringan fire rated 202 m2
Pintu besi tahan api double 2 Unit
Pintu besi tahan api single 3 Unit
Kaca tempered 1000 x 2000 mm , tebal 12mm 1 unit
Dinding kaca 18,56 m2
1.1.2.3 RAISED Floor System
- Panel raised floor calsium HPL 97 m2
- Perforated raisedfloor 32 unit
- Pedestal
- Stringer
- Tile lifter 1 unit
- Insulation 97 m2
- Installation 1 lot
- Ramp way ( 2 unit ) 1 lot
1.1.3 Interior
1.1.3.1 Ruang NOC/Monitoring
- Meja kerja 8 set
- Meja Tamu (persegi) 1 set
- Kursi kerja 8 set
- Sofa (4 kursi) 1 set
- Lemari Besar 1 set
- Lemari Kecil 1 set
- Pintu geser kaca, autoclose 1 set
1.1.3.2 Ruang Staging
- Meja 2 set
- Kursi 6 set
- lemari gantung (45 x 80 x 200 cm) 2 set
1.1.3.3 Entrance
- Loker 1 set
- Rak Sepatu 1 set
1.2 MOBILISASI 1 lot

19
6) Pekerjaan Struktur Ruangan Command Center
Pekerjaan ini meliputi pengadaan pekerjaan Struktur, Backdrop Videowall
dan bahan-bahan kelengkapannya, Furniture serta alat-alat bantu yang
dibutuhkan.

4.1 Pekerjaan Struktur dan Interior Ruangan Command Center


Design interior Ruangan Command Center adalah sebagai berikut

20
Gambar Design Pengembangan Command Center LPSK

Spesifikasi Teknis
Spesifikasi teknis struktur dan interior ruangan command center
adalah:
a) Struktur
 Rangka:
Besi Holow 40mm x 40mm tebal 1,8mm Fin.
Spraypaint ex. Danaglos/Danapaint/setara
 Base Plate; 3mm
 Dinabolt & aksesoris
b) Backdrop
 Panel Backdrop: bahan Plywood dan MDF dengan
lapisan HPL 0,8 mm
 Base Panel Videowall, dengan Bahan Plywood tebal
18mm, Finishing Cat
c) Furniture
 Bahan Plywood tebal 18mm, Finishing dengan lapisan
HPL.
 Besi Holow 40mmx40mm; tebal 1,8mm

21
b) Volume pekerjaan sipil Command Center

A PEKERJAAN PRA PROJECT


I PEKERJAAN PERSIAPAN
Mobilisasi Alat dan Bahan 1,00 Ls
Proteksi, Kebersihan dan keamanan Area Kerja 1,00 Ls
Proteksi & Alat Bantu 1,00 Ls
Pengukuran dan Ploting Area 1,00 Ls
Desain & Gambar Kerja 1,00 Ls

II PEKERJAAN BONGKARAN
Pekerjaan Pembongkaran Partisi dan Pintu Kaca 1,00 Ls
Pekerjaan Pembongkaran Plafond Existing 1,00 Ls
Pekerjaan Pembongkaran Inst. Listrik Existing 1,00 Ls
Pekerjaan pembongkaran Partisi Gypsum Existing 1,00 Ls
Pekerjaan Pembongkaran Instalasi Lampu Existing 1,00 Ls
Pekerjaan Pembongkaran/Pemindahan Jalur Flexible 1,00 Ls
Duct AC
Pekerjaan Pembongkaran Instalasi Smoke/Heat Detector 1,00 ls
Existing ( Springkler )
Pekerjaan Pembuangan Sampah bongkaran 1,00 ls
Pembersihan area kerja 1,00 ls

B PEKERJAAN SIPIL/INTERIOR
I PEKERJAAN STRUKTUR
1 Pek. Struktur Walldisplay 5x2, 55" uk. 6100 x 3800 1,00 Set
Spek :
- Besi Holow 40x40mm thk.18mm, Fin. Spraypaint ex.
Danaglos/Danapaint/setara
- 3mm thk. Base Plate, Dynabolt dan Material pendukung
2 Pek. Wood Panel Walldisplay Uk. 8234 x 3800 22,96 m2
Spek :
- Plywood 18,15,12,9,dan MDF 3mm Fin. HPL ex. TACO
- Ornamen Padded Wall List Stainless
3 Base Tv uk 6100 x 1380 8,42 m2
Spek :
- Plywood 18mm

22
- Black Painted Doff
4 Pek. List Stainless t: 5 Cm 1,00 Ls

II PEKERJAAN PLAFOND
1 Pek. Plafond Flat 77,80 m2
Spek :
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
2 Pek. Plafond Drop 37,88 m2
Spek :
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
3 Pek. Plafond Lingkaran 10,46 m2
Spek :
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
4 Pek. Kuf Plafond 26,50 m2
Spek :
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
5 Pek. List Plafond 46,80 m'
Spek :
- Gypsumboard 9mm, Ex. Jayaboard Fin. Cat
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
6 Pek. Pengecatan Plafond Gypsum 126,14 m2
Spek :
- Cat Interior ex. Vynilex

III PEKERJAAN FURNISHING, PELAPIS DINDING & PINTU


1 Pek. Pemasangan Dinding Partisi Gypsum 2 Muka utk m2
Pelapis Kaca 104,10
Spek :
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
2 Pek. Wallpanel Dinding Kanan Kiri 90,80 m2
Spek :
- Plywood 9 mm Fin. HPL Ex. TACO/Setara
- List Stainless

23
3 Pek. Bakdrop Panel (Back Panel ) Uk. 8200 x 2800 22,96 m2
Spek :
- Plywood 9 mm Fin. HPL Ex. TACO/Setara
4 Pek. Lapisan Kaca area koridor 90,82 m2
Spek :
- Sticker
5 Pek. Pintu Utama uk. 1000 x 2400 1,00 unit
Spek :
- Kaca Tempered 12mm
- Handle Pintu Kaca
- Accessories
I PEKERJAAN LANTAI
V
1 Pek. Peninggian Struktur Lantai 33,50 m2
Spek :
- Besi Siku 40x40 thk. 3mm Fin. Spraypaint
- Plywood 18 mm Fin. Karpet
- Accessories
2 Pek. Lantai Karpet 80,36 m2

V PEKERJAAN FURNITURE
1 Pek. Credenza Uk. 1400 1,00 Unit
Spek :
- Plywood 12, 15, 18mm + MDF 3, 6mm Fin Duco
2 Pek. Meja Operator Uk. 4800 ( 4 set ) 2,00 Unit
Spek :
-Plywood 12 mm, MDF 6mm Fin. Duco
- Lampu Linier Cover Acrillyc Lis Stainlee
- Box Lampu Linier Cover Acrillyc List Stainless
- Front table Cover Stainless
3 Pek. Meja Operator Lengkung Uk. 5200 x 750 2,00 Unit
Spek :
-Plywood 12 mm, MDF 6mm Fin. Duco
- Lampu Linier Cover Acrillyc Lis Stainlee
- Box Lampu Linier Cover Acrillyc List Stainless
- Front table Cover Stainless
4 Pek. Pengadaan Kursi 12,00 Unit
Spek :

24
- Senator II GAR Synch T35 SCB
5 Pek. Logo LPSK 1,00 Un
Spek :
- Neon box Dia. 600 Cm
6 Lettering LPSK t: 30 Cm 1,00 Lot
Spek :
- Stainless stell emboss + bending
7 Lettering LEMBAGA PERLINDUNGAN SAKSI DAN KORBAN 1,00 lot
t: 12 Cm
Spek :
- Stainless stell emboss + bending

V PEKERJAAN PENERANGAN + AUDIO


I
1 Pek. Inst. Lampu Penerangan 35,00 ttk
Spek :
-Kabel NYM 2x1.5 ex. Supreme
2 Pek. Lampu Downlight type Slim 18 Watt 18,00 unit
Spek :
-slim Diameter 15 Cm, ex. Phillips
3 Pek. Lampu Spotligt ww 17,00 unit
4 Pek. Lampu LED Linier incl Ballast 98,20 m'
5 Passive Mounting Speaker 8" 4,00 unit
Spek : Tannoy DVS8T/Setara
6 Power Amplifier 240 Watt 70V w/ DSP 1,00 unit
Spek : Lab Gruppen Lucia 240/1-70 /Setara
7 Dual Handheld Wireless Mic 2,00 unit
Spek : Shure BLX288/PG58 /Setara
8 10 Channel Analog Mixer 1,00 unit
Spek : Yamaha MG 10XU /Setara
9 Material Instalasi Audio 1,00 lot

6.1.2 Pekerjaan Sistem Kelistrikan

Pekerjaan sistem kelistrikan yang dilakukan harus ketentuan berikut ini:


Pedoman Kerja
1) Dalam melaksanakan instalasi ini, Penyedia harus mengikuti standar berikut :
 Persyaratan Umum Instalasi Listrik 2000 (PUIL 2000)

25
 VDE (Verband der Elektrotechnik), ISO (International Standard
Organization), BS (British Standard), LMK.
2) Penyedia harus menyediakan gambar dan rencana kerja
3) Sumber daya listrik bersumber dari Perusahaan Umum Listrik Negara.
4) Semua instalasi penerangan dan stop kontak menggunakan sistem 3 core
dimana core yang ke tiga merupakan jaringan pentanahan disatukan ke panel
listrik.
5) Semua panel listrik harus diberi pentanahan dengan kawat.
6) Sistem tegangan 220 V/380 V, 3 phase, 50 HZ, instalasi penerangan dan stop
kontak 220 V- 1 phase - 50 HZ.

Pekerjaan instalasi sistem kelistrikan meliputi :


1) Melaksanakan seluruh instalasi penerangan dan stop kontak dalam ruangan
Data Center dan Comand Center.
2) Menyediakan dan memasang semua panel – panel listrik
3) Menyediakan Seluruh instalasi pentanahan.
4) Membuat gambar kerja dan menyerahkan gambar revisi.
5) Melakukan pengujian.
6) Melaksanakan pemeliharaan dan jaminan.
7) Memasang nama-nama panel dan hubungan circuit breaker berupa
tulisan yang jelas dari bahan yang tahan lama

Persyaratan umum bahan dan material


Syarat-syarat dasar / umum bahan dan peralatan adalah sebagai berikut :
a. Bahan atau peralatan dari kualifikasi atau tipe yang sama, diminta merek
atau dibuat oleh pabrik yang sama.
b. Dalam setiap hal, suatu bagian atau suku-suku dari peralatan yang jumlahnya
jelas ditentukan, maka jumlah tersebut harus tetap lengkap setiap kali
peralatan itu diperlukan, sehingga merupakan unit yang lengkap. Apabila
suatu bahan atau peralatan disebutkan pabrik pembuatnya atau mereknya,
hal ini dimaksud untuk mengikat mutu, tipe perencanaan dan karakteristik.
c. Kapasitas yang tercantum dalam gambar atau spesifikasi teknis adalah syarat
minimum.
d. Penyedia boleh memilih kapasitas yang lebih besar dari yang diminta dengan
syarat :
1) Mengajukan persetujuan dari PPK.
2) Tidak menyebabkan sistem menjadi lebih sulit.
3) Tidak menyebabkan pertambahan bahan.

26
4) Tidak meminta pertambahan ruang.
5) Tidak menyebabkan adanya tambahan biaya.
6) Tidak menambah waktu penyelesaian pekerjaan.

Spesifikasi Teknis bahan dan pekerjaaan instalasi listrik

1) Kabel Listrik
a) Merupakan merk 4 Besar PLN/LMK
b) Kabel berstandar SNI
c) Kelas tegangan 1000 volt dan 600/1000 volt.
d) Inti penghantar tembaga.
e) Isolasi PVC, sheated dan lain-lain.
f) Jumlah inti satu atau banyak.
g) Jenis kabel : NYM/NYY/NYA dan lain-lain sesuai gambar rencana.
h) Produksi dalam negeri Standard PLN/LMK dan SNI.
i) percabangan, pembelokan, pengetapan dan sebagainya harus
menggunakan fitting yang sesuai yaitu socket, elbow, T-doos, croos-
doos, terminal 3 M, isolasi ban, klem besi dan lain-lain

2) Kabel Grounding
a) Inti tembaga
b) Jenis kabel BC atau NYY/NYA

3) Sakelar dan Stop kontak


a) Mekanisme sakelar rocker dengan rating 16 A – 250 volt untuk 1
phase dan/atau 32 A – 400 volt dengan warna dasar putih, jenis
pasangan recess-mounted atau surface-mounted.
b) Stop kontak biasa dengan rating 10 A – 250 volt. 2 kutub ditambah
1 untuk pentanahan

4) Instalasi power untuk rack network dan server


Instalasi power untuk rak dibawah raised floor yang ditarik kemasing-
masing rack menggunakan kabel 3 x 2,5 mm dilengkapi protector/pipa
dan ujungnya menggunakan stok kontak serta pemasangan kabel harus
diletakkan pada kabel tray yang telah disediakan

5) Panel Elektrikal

27
Spesifikasi Umum
a) Tegangan kerja : 220 V/380 V, 3 phase, 50 Hz.
b) Interupting capacity untuk main breaker min 400 A.
c) Jenis panel indoor freestanding lengkap dengan pintu.
d) Lalu lintas kabel :
 Masuk dan keluar dari atas menggunakan kabel
 Masuk dan Keluar dari bawah menggunakan kabel.

e) Setiap Incoming yang bersumber dari PLN harus dilengkapi dengan


Arrester.
f) Menyerahkan Gambar kerja untuk panel elektrikal

Spesifikasi Rumah Panel dan Busbar


a) Ukuran rumah panel harus dapat mencakup semua peralatan
dengan penempatan yang cukup secara elektris dan fisik.
b) Pemasangan semua komponen harus dapat dicapai dari bagian
depan dengan mudah.
c) Rumah panel type Free Standing dari besi pelat dengan tebal tidak
kurang dari 2 mm, sedang tipe wall mounted tebal plat tidak
kurang dari 1.2 mm.
d) Semua permukaan pelat baja sebelum dicat harus mendapat
pengolahan pembersihan sejenis ”Phospatizing treatment” atau
sejenisnya. Bagian dalam dan luar harus mendapat paling sedikit
satu lapis cat penahan karat. Untuk lapisan akhir cat finish bagian
luar dengan warna abu-abu.
e) Ruang pencapaian harus cukup untuk memudahkan kerja.
f) Label-label terbuat dari bahan trafolite yang tersusun berlapis putih
hitam dan digrafir sesuai kebutuhan dalam bahasa Indonesia.
g) Bukaan ventilasi dari bagian sisi panel.
h) Semua pengkabelan di dalam panel harus rapi terdiri atas kabel-
kabel berwarna, mudah diusut dan mudah dalam pemeliharaan.
i) Busbar dan teknik penyambungan harus menurut peraturan PUIL.
Bahan dari tembaga yang berdaya hantar tinggi, bentuk persegi
panjang dipasang pada pole- pole isolator dengan kekuatan dan
jarak sesuai ketentuan untuk menahan tekanan dan mekanis pada
level hubung singkat.
j) Busbar dalam panel harus disusun sebaik-baiknya sampai semua
terminal kabel atau busbar lainnya tidak menyebabkan lekukan

28
yang tidak wajar. Busbar harus dicat secara standard untuk
membedakan fasa-fasanya.
k) Batang penghubung antara busbar dengan breaker harus
mempunyai penampang yang cukup dengan rating arus tidak
kurang dari 125% dari rating breaker.
l) Pada sambungan-sambungan busbar harus diberi bahan pelindung
(tinned).
m) Ujung kabel harus memakai sepatu kabel dari dan sarung kabel
berwarna bahan tembaga.
n) Khusus untuk Pengadaan dan Pemasangan Panel Data Center (
P.ATS + P.MDP ) dengan spesifikasi khusus sebagai berikut:
 Panel Free Standing
 Ukuran : H2000 x W1200 x D600 mm
 Material : SPCC Sheet Steel Indoor
 Protection : IP 41
 INCOMING
- MCCB 4P 160~400A 50KA :Schneider Electric/Eq
- Motor Mechanism :Schneider Electric/Eq
- Under Voltage Release :Schneider Electric/Eq
- Aux. Contact :Schneider Electric/Eq
- MCB 1P 6 A 4.5 KA :Schneider Electric/Eq
- Pilot Lamp R,S,T :Schneider Electric/Eq
- Illuminated push button ON-OFF :Schneider Electric/Eq
Selector Switch 3 Posisi :Schneider Electric/Eq
- Digital Power Meter :Schneider Electric/Eq
- Control Raly, Timer :Omron

 OUTGOING
- MCCB 4P 140~200A 36KA :Schneider Electric/Eq
- Toggle Locking Device :Schneider Electric/Eq
- MCCB 3P 35~50A 36KA :Schneider Electric/Eq
- MCB 1P 10,16,32A,6KA :Schneider Electric/Eq
- MCCB 3P, 16, 32 A, 6 KA :Schneider Electric/Eq

6) Instalasi Kabel Tray


Pekerjaan instalasi kabel tray mengikut ketentuan teknis berikut :
a) Bahan penyangga terbuat dari perforated steel plate yang
digalvanis.

29
b) Bahan support dari besi siku yang dicat.
c) Ukuran lebar disesuaikan dengan gambar.
d) Ukuran besi siku harus dihitung beban dari kabel dan lenturan besi.
e) Gantungan memakai besi beton 3/8”.
f) Setiap jarak 40 cm diberi tulangan penguat sehingga berbentuk
cable ladder
g) Pengadaan dan pemasangan kabel tray untuk Power yang
ditempatkan dibawah raised floor dan diatas plafon
 Kabel Tray : Galvanis
 Ukuran : 300 x 100 x 3000 mm, komplit dengan penutup tray dan
aksesoris disesuaikan dengan jalur kabel tray dalam gambar
h) Pengadaan Wire mesh diatas rack untuk instalasi kabel data antar rack
cabinet
 Wire Mesh/Cablofil ukuran 300 x 54 x 3000 mm lengkap dengan
aksesoris disesuaikan dengan jalur dalam gambar
i) Pengadaan Fiber Raceway/Runner diatas rack untuk instalasi kabel
Fiber antar rack cabinet
 Fire retardant plastic, Halogen Free, UL94-VO rated
 Fiber Runner 8 x 4 in ( 220 x 100 mm ) lengkap dengan aksesoris
 ISO 9001 Certified Quality

7) Instalasi Grounding
Pembuatan Ground dengan tahanan maksimum 3 ohm menggunakan
Ground Rood dan menyediakan bak control untuk pemeliharaannya.

Volume Pekerjaan sistem kelistrikan

No Description Unit Qty

D Pekerjaan electrical
Pekerjaan Panel dan Instalasi Rack
1 Penambahan dan Pemasangan MCCB 400/630 A, 4 P 1 pcs
- Untuk Penambahan MCCB di panel Induk
Pengadaan dan Pemasangan Kabel Feeder P.ATS & P.MDP Data
2
Center ( PLN )
a. Kabel NYY 4 x ( 2 x 1 x 150 mm ) c/w aksesoris 50 mtr
b. Kabel NYA 2 x 1 x 95 mm ( Grounding ) 50 mtr

30
3 Pengadaan dan Pemasangan P.ATS & Panel MDP Data Center 1 set
Free Standing ( 2000 x 1200 x 600 )mm (Isi sesuai online
-
digram)
4 Instalasi Power Untuk Rack Network dan Server
a. Kabel NYM 3 x 4 mm terproteksi oleh pipa conduit 32 ttk
b. Stop Kontak Mobile Socket 32 A, 1 Phase 32 ttk
5 Instalasi Power Untuk R. NOC + R.Staging
a. Kabel NYM 3 x 2,5 mm terproteksi oleh pipa conduit 8 ttk
b. Stop Kontak 8 ttk
6 Instalasi Power Untuk R. Command Center
a. Kabel NYM 3 x 2,5 mm terproteksi oleh pipa conduit 24 ttk
b. Stop Kontak 22 ttk
7 Instalasi Power Untuk R. Rapat Paripurna & R.Sidang
a. Kabel NYM 3 x 2,5 mm terproteksi oleh pipa conduit 40 ttk
b. Stop Kontak 40 ttk
Pekerjaan Lampu
8 Pekerjaan Inst. Lampu R. Server,R. Network. NOC dan R. Utility 27 ttk
9 Pekerjaan Inst. Saklar Double 6 ttk
10 Pekerjaan Lampu Master LED Tube T8 - 2 x 20 , c/w aksesoris 21 ttk
11 Pekerjaan Lampu Downlight Type Slim 4" 6 bh
12 Pekerjaan Spotlight 2 Mata 2 bh
13 Pekerjaan Lampu LED Strip incl. Ballas 8 m'
14 Pekerjaan Testing dan Commisioning 1 Ls
15 Material Bantu 1 lot

Pekerjaan Kabel Tray


1 - Kabel Tray power ( dibawah Raised Floor ) 1 lot
- Kabel Tray Galvanis
- Kabel Tray W300mm H100mm L3000mm + Aksesoris
2 - Kabel Tray power ( diatas plafond) 1 lot
- Kabel Tray Galvanis
- Kabel Tray W300mm H100mm L3000mm + Aksesoris
3 Fibber Raceway dibawah plafond 1 lot
- Fibber Raceway 220 x 100 mm + aksesoris

31
4 Wire Mesh -Cablofill di bawah plafond 1 lot
- Wire Mesh, Cablofil 300 c/w aksesoris
Pemasangan Kabel Tray/Fiber Raceway disesuaikan dengan layout

Pekerjaan Grounding
1 Grounding/Pentanahan ( Tahanan Maksimum 3 Ohm ) 1 lot
- Ground Rood dari tembaga murni
- Conductor NYA 50 mm
- Bak Kontrol + Grounding Plate
- Support Material & Accecories
2 Grounding Raised Floor 1 lot
- Bar Grounding/Grounding Plate
- Kabel BC 25 mm c/w Aksesoris

6.1.3 UPS modular


UPS modular yang sediakan harus memenuhi spesifikasi berikut :

Capacity 120 kVA


Max. Frame Capacity 180 kVA
Module Capacity 30 kVA/27 Kw
On-line double conversion,
Technology
three-level PWM, DSP control

INPUT
Nominal Voltage 380/ 400/ 415Vac, (3Ph+N+PE)
Voltage range -43% +20%
Frequency 50 / 60 Hz
Total Harmonic Distortion (THDi) ≤ 3%
Power Factor > 0.99

OUTPUT
Output Voltage 380/ 400/ 415 Vac (3Ph+N)
Accuracy ±1%
Output Frequency 50/60 Hz
Total Harmonic Distortion (THDv) ≤1%

32
Power Factor 0,9
Crest Factor 3:1
Module Performance ( On Line ) >96%
125% for 10 mins / 150% for 1
Admissible overload
min

BATTERY
Lead-Acid Sealed, maintenance
Battery Type
free
Battery Voltage (configurable) ±192 Vdc\ ±264Vdc
Charger maximum power 20% of total system power
min. 15 menit pada beban 100
Backup time
kW

COMMUNICATION
Touchscreen, 5.7”, LEDs and
Display
keypad
Comm Port RS-232, RS-485, and relays
1 × Nimbus SNMP/1 ×
Intelegent port
extended relays Nimbus

GENERAL
Operating Temperature 0°C - 55°C
Relative humidity Up to 95%, non - condensing
Operating altitude 2,400 masl
Acoustic Noise at 1 meter <65 db(A)

SYSTEM
Maximum no. modules per system 6
Maximum power per system ( kVA ) 180

STANDARDS
Safety EN-IEC 62040-1
Electromagnetic compatibility ( EMC ) EN-IEC 62040-2
VFI-SS-111 as per EN-IEC
Operation
62040-3
Quality adn Evironmental Management ISO 9001 and ISO 14001

33
DIMENSIONS
UPS Cabinet 180 kva ( D x W x H ) Max : 1100 x 600 x 1600 mm
UPS Modul 30 kva( D x W x H ) Max : 790 x 460 x 134 mm
WEIGHT
UPS Cabinet 180 kva Max : 199 ÷ 369
UPS Modul 30 kva Max : 34 Kg

Garansi UPS 1 Tahun

Penambahan Plat Esser dipasang sejajar Raised Floor untuk penguat dudukan UPS
dan Bank Battery, minimal tebal 7 mm.

Volume Pekerjaan UPS Modular

No Description Qty Unit

C Pengadaan dan Pemasangan UPS Modular 2 x 120 kva


1 Pengadaan dan Pemasangan UPS Modular 120 Kva 2 paket
Power modul 30 KVA : 4 unit
frame 180 KVA
Technology : Three-level IGBT, DSP control
Input : 3x380/400/415 + N
Output : 3x380/400/415 + N
input THDi : < 3%
Frequency : 50/60 Hz
Output PF : 0,9
Paralel Kit
2 Battery 2 paket
Battery yang digunakan VRLA battery
Backup time : 15 min ( @ 100 kw )
Battrery Configurable between +/-192 and +/-264 Vdc
Plat Esser ketebatalan minimal 7 mm ( untuk penguatan
dudukan/kaki penahan Battery bank dan UPS ), ukuran plat
disesuaikan dengan dimensi ups dan rak battery

34
3 Material Instalasi 30 meter
Kabel Input/Output UPS plus aksesoris:
Kabel NYY 4 x 50 mm + 1 Kabel (NYA/BC) Grounding
4 Jasa Pelaksanaan 1 lot
- Install dan start - Up UPS
- Install battery dan rack Battery
- Test and Commisioning

6.1.4 Genset dan Rumah Genset

A. Pengadaan Genset
Lokasi Pekerjaan berada di Area parkir Gedung LPSK Jakarta.
Lingkup Pekerjaan Genset ini meliputi :
 Pengadaan Generator Set Kapasitas Minimal 300 kVA (Silent Type)
sebanyak 2 unit
 Pengadaan, pemasangan, installasi dan pengujian unit Diesel Genset
Silent Type, yang sudah dilengkapi dengan sistem peredam suara
termasuk didalamnya :
- Sincronice system, Lengkap dengan Grounding, silenser, exhaust
system, angkur
- Testing Comisioning pabrik, dan seluruh alat bantu yang
mendukung kesempurnaan system.
- Pekerjaan instalasi exhaust gas pipe, muffler termasuk support
clamp, lapisan ceramic fiber dan allumunium sheet jacket.
- Pekerjaan instalasi pipa bahan bakar, lengkap dengan support dan
accessories (chek valve, ball valve, gate valve, strainer, fuel water
separator) dari daily tank.
- Pekerjaan Pembuatan ducting Radiator Genset dengan BJLS.
 Pengadaan dan pemasangan panel sinkron / panel kontrol genset
termasuk perlengkapannya.

35
 Pengadaan, pemasangan dan installasi kabel power genset NYY
4x150mm dan aksesorisnya ke Panel Kontrol Genset (PKG).
 Pengadaan, pemasangan dan pengujian tangki solar mingguan dengan
kapasitas 2000 liter, sesuai dengan kebutuhan lengkap dengan
pemipaan, dan peralatan bantunya.
 Pengadaan dan pemasangan instalasi pipa bahan bakar dari Genset dan
tangki bahan bakar mingguan.
 Pengadaan sistem Grounding lengkap dengan rod dan bak kontrol.
 Pengadaan, pemasangan dan pengujian instalasi Grounding System.
 Pengadaan operation, maintenance, manual book dan as built drawing.
 Melakukan training operator.
 Pekerjaan sipil (pondasi, galian & urukan, penanaman, sparing &
opening, bobokan & pemotongan, dan perapian kembali, dll.).
 Pekerjaan Test dan Commisioning Genset Berikut Perlengkapannya
termasuk didalamnya Penyediaan Bahan Bakar Untuk Pekerjaan
tersebut.
 Memproses perijinan pada Dinas/Instansi terkait (jika ada)

SPESIFIKASI TEKNIS GENSET


Generator Set (Genset)
1. Engine
a) Kapasitas mesin: Minimal 300 kVA – Prime Power
b) System gas buang : turbo charger
c) Pendingin :Water Cooling With Radiator.
d) Putaran mesin: 1500 Rpm.
e) Jumlah silinder : 6 (V)
f) Putaran silinder : 4 stroke.
g) Type governor : electronic.
h) Pelumas : oli.

36
i) Indikator pengukur :
 Oil pressure gauge.
 Water temperature gauge.
 Oil temperature gauge.
 Charging ammeter.
 Tachometer / RPM.
 Hour Counter.
j) Keamanan :
 Low oil pressure.
 High water temperature.
 Over speed.
 Over voltage.
 Over Load.
 Emergency Push Button.
k) Perlengkapan :
 Battery dan dinamo charger
 Auto star/stop control
 Oli mesin.
 Coolant addictiv.
 Axial compensator.
 Engine instrument panel.
 Residential silencer.
 Manual Operating Book.
 Tool Kit.
2. Generator
a) Rate output : Minimal 300 kVA
b) Tegangan : 380/220 V
c) Frekuensi : 50 Hz.
d) Power factor : 0.8.

37
e) Exiter : brushless
f) Connection : Star – 4 wires.
g) Protection : IP 23.
h) Insulation : class H.
i) Ambient Temp : 40°C.
j) CT droop kit.

Panel Sikron / Panel Kontrol Genset


1) Tipe: Free standing, front operated, dim: (H)2100mm x
(W)800mm x (D)1000mm atau disesuaikan dengan
komponennya.
2) Cable power Entry : from bottom and top.
3) Tegangan : 400/220 VAC.
4) Busbar : copper dengan support lengkap.
5) Protection device: Circuit breaker minimum 65kA dengan Over
Current, Short Circuit, Under Voltage Relay, Earth Fault Relay
and Shunt Trip & Reverse Power Relay dan Over Voltage Relay.
6) Index Protection box : min. IP 31.
7) Measuring device :
a) Modul Controller Genset dengan display LCD dengan
minimal fungsi ( tidak terbatas pada) :
 Automatic main failure
 Automatic synchronizing
 Automatic Load Sharing
 Automatic Load Dependent Control
 Automatic Load Shedding
 Automatic Var Sharing
 Soft Loading/Unloading
 Main Fail Delay Timer

38
 Plant Run on cool down timer
 Synch Check Display
 Programing PLC Internal
 History Record (Minimum 500 Event
 MOD Bus Interconnection
 Protection: Over/Under Voltage, Over/Under
Frequency, Reverse Power, Instantaneous Over current,
Timed Over Current, Unbalance Load, Ground Fault,
Over Load
b) Modul Controller Genset dengan display LCD dengan
minimal Hour meter.
c) Synchronoscope
d) Volt meter DC.
e) Ampere meter DC.
f) Signal Lamps :
 Start.
 Start Failure.
 Engine Running.
 Supervision “On"
 Automatic.
 Manual.
 Main "ON".
 Generator "ON".
 Low oil Pressure.
 Over temperature.
 Generator overload under voltage and earth.
 Generator over speed control.
 Under Voltage trip.
 Over Load.

39
 Over Current.
g) Push Button:
 On Generator Breaker.
 Off Generator Breaker.
 Reset.
 Signal Test.
 Emergency Stop.
 Semi auto forward sinkron.
 Semi auto back sinkron.
h) Selector Switch :
 Automatic Breaker Service.
 Manual Breaker Service.
 Auto Generator Service.
 Manual Generator Service.
 Slave Generator Service.
 Generator circuit breaker lengkap dengan lampu
indikator.
j) Battery Charger 220VAC, 24VDC/10A.
k) Battery 24VDC,20-40Ah, maintenance free, calsium
battery.
l) Panel-panel harus dibuat dari plat besi tebal 2 mm dengan
rangka besi dan seluruhnya harus di zinchromat dan diduco
2 kali dan harus dipakai cat dengan cat Powder Coating,
warna RAL 7032. Pintu dari panel-panel tersebut harus
dilengkapi dengan master key.
m) Konstruksi dalam panel-panel serta letak dari komponen-
komponen dan sebagainya harus diatur sedemikian rupa,
sehingga bila perlu dilaksanakan perbaikan-perbaikan,
penyambungan-penyambungan pada komponen-

40
komponen dapat mudah dilaksanakan tanpa mengganggu
komponen - komponen lainnya.
n) Setiap panel harus mempunyai busbar copper terdiri dari 3
busbar phase R-S-T, 1 busbar neutral dan 1 busbar untuk
grounding dengan support yang kokoh. Besarnya busbar
harus diperhitungkan untuk besar arus yang akan mengalir
dalam busbar tersebut tanpa menyebabkan suhu yang
lebih dari 65°C. Setiap busbar copper harus diberi warna
sesuai peraturan PLN, lapisan yang dipergunakan untuk
memberi warna busbar dan saluran harus dari jenis yang
tahan terhadap kenaikan suhu yang diperbolehkan.
o) Alat ukur yang dipergunakan adalah jenis semi flush
mounting dalam kotak tahan getaran, untuk metering
utama dengan ukuran 96 x 96mm dan atau 48 x 48mm
untuk metering DC, dengan skala linear dan ketelitian 1%
dan bebas dari pengaruh induksi serta sudah tersertifikasi
dan standar PLN/LMK
p) Ukuran dari unit panel kontrol Genset bisa menyesuaikan
dengan keadaan dan keperluan sesuai dengan yang telah
disetujui.
q) Komponen-komponen pengaman yang dapat dipakai
adalah :
 Incoming PKG Rated Current :MCCB/ACB dengan
kapasistas disesuaikan ( Minimal 630 A )
- Operating Voltage : 400/220 V
- Frequency : 50 Hz
- Type : Fixed type
- Poles : 3 Phase, 4 Pole
- Breaking Capacity : min. 65kA

41
Termasuk : Motorized, Closing Coil, Under Voltage Trip
& Aux Contact, Shunt Trip, Trip Unit (Over Current &
Short Circuit) Permitted ambient temp : 55°C
 Outgoing PKG
- Rated Current : MCCB/ACB dengan kapasistas
disesuaikan( Minimal 630 A )
- Operating Voltage : 400/220 V
- Frequency : 50 Hz
- Type : Fixed type
- Termasuk : Motorized, Closing Coil, Under Voltage
Trip & Aux Contact, Shunt Trip, Trip Unit (Over
Current & Short Circuit)
- Poles : 3 Phase, 4 Pole
- Breaking Capacity : min. 65kA Permitted ambient
temp : 55°C

Tangki
1) Tempat Penyimpanan Bahan Bakar (Tangki Mingguan)
a) Tangki bahan bakar harian sudah built in dengan Genset (min. 500
liter).
b) Bahan bakar tangki mingguan dibuat dari mild steel plate tebal
min. 5mm, harus bebas dari karat dan tekukan.
c) Bagian luar tangki harus di zinchromat dan dicat sesuai warna
kesepakatan.
d) Pelaksanaan pekerjaan ini harus dilaksanakan oleh tenaga yang
berpengalaman khusus tangki dengan peralatan yang cukup dan
memenuhi persyaratan keselamatan kerja.
e) Kapasitas tangki mingguan untuk persediaan supply ke tangki
harian genset.

42
f) Tangki ini harus memiliki fungsi - fungsi seperti manhole, saluran
in & out, saluran ventilasi, indicator volume dengan proteksi,
lubang kuras, kaki dan tangga untuk pengisian, lengkap juga
dengan proteksi valve – valve dan gembok.
g) Bahan bakar genset running diambil/ditransfer dari tangki harian.
h) Menyediakan BBM solar Industri di tangki sejumlah 1000 liter.

2) Pemipaan Bahan Bakar


a) Jenis pipa yang dipakai adalah black steel Sch 40.
b) Sambungan lengkung, reducer dan expander dan sambungan
cabang pada pekerjaan perpipaan harus mempergunakan fitting
buatan pabrik.
c) Dilengkapi aksesoris water sparator sesuai kapasitas masing–
masing genset, ball valve, cek valve, strainner, dll.
d) Sambungan antar pipa menggunakan drat, kecuali yang
menggunakan flange, harus dilas.

Kabel Tegangan Rendah


Kabel-kabel yang dipakai standart SPLN, SNI dan IEC. Dapat dipergunakan
untuk tegangan min. 0,6/1 kV, berpenghantar tembaga, isolasi PVC. Kabel
toefur yang dipergunakan type NYY 150 mm. Sepatu kabel/scoen, marker
/penanda/vynyl, harus sesuai ukuran kabel dan standar SNI/PUIL.

a) Pengadaan/Pembangunan Rumah Genset


Lokasi Pembangunan rumah genset ada di area parkir Gedung LPSK,
para calon penyedia dipersilahkan untuk melakukan survey lokasi
guna mendapat gambaran tentang pembangunan Rumah Genset dan
Perlengkapannya tersebut.

43
Gambar. Lokasi pembangunan rumah genset

Adapun design secara umum dapat diliat seperti dibawah ini:

Lingkup Pekerjaan Pembangunan Rumah Genset


Lingkup pekerjaan adalah pembangunan ruang genset
untuk memasok sumber daya listrik ke ruang Data Center
Lembaga Perlindungan Saksi dan Korban (LPSK) yang
berlokasi di daerah Jakarta Timur dengan pekerjaan yang
harus dilaksanakan oleh Penyedia termasuk pengadaan
tenaga kerja, bahan-bahan, alat- alat dan segala keperluan
yang berhubungan dengan pekerjaan pembangunan yang
akan dilaksanakan.
Hal ini meliputi:
 Pekerjaan Pendahuluan

44
 Pekerjaan Tanah dan Pondasi
 Pekerjaan Struktur
 Pekerjaan Arsitektur
 Pekerjaan Mekanikal dan Elektrikal

Setting Out
 Untuk menentukan posisi serta keinginan rencana
bagunan di lapangan, Penyedia harus melakukan
pengukuran di lapangan secara teliti dan benar,
sesuai dengan kondisi lapangan seperti ditunjukkan
dalam gambaran umum diatas.
 Dalam hal terdapat perbedaan antara rencana dalam
gambar dengan hasil pengukuran, maka Penyedia
harus melaporkan hal ini kepada Konsultan pengawas
(jika ada)/Pihak LPSK untuk mendapatkan keputusan
dan dinyatakan dalam Berita Acara.
 Keputusan akan didasarkan atas keamanan konstruksi
serta kelancaran kegiatan di luar dan didalam
Kompleks.

Pekerjaan Persiapan

 Pembersihan Lapangan
o Untuk tempat kerja, penumpukan bahan bahan
bangunan gudang sementara dapat disesuaikan
dengan kondisi lapangan. Penyedia harus terlebih
dahulu membersihkan serta membenahi lapangan.
 Penerangan, Pagar dan tanda-tanda pengaman.
o Penyedia harus menyediakan penerangan di
daerah kerja, pagar dan tanda-tanda pengaman
yang diperlukan

45
Pekerjaan Pendahuluan
 Penyedia akan diberikan petunjuk mengenai gudang
penyimpanan bahan untuk pelaksanaan pekerjaan ini.
 Penyedia harus membatasi operasinya dilapangan yang
betul betul diperlukan untuk pekerjaan tersebut. Tata
letak yang meliputi jalan masuk lokasi penyimpanan
bahan bangunan dan jalur pengangkutan material
dibuat oleh Penyedia dengan persetujuan Konsultan
Pengawas (jika ada)/Pihak LPSK.

Material
 Bahan yang dipakai diutamakan Produksi Dalam Negeri
yang memenuhi pesyaratan teknis yang ditentukan.
 Contoh material bangunan, mekanikal, elektrikal dan
arsitektur wajib disetujui oleh pihak pemberi kerja
sebelum dilakukan pembelian, dengan mengajukan
papan contoh material dan surat persetujuan.
 Jika Penyedia mengajukan bahan lain yang akan
digunakan , maka mutunya minimal harus sama
dengan yang disyaratkan dalam Dokumen Tender.
Untuk pemesanan bahan itu harus diberitahukan
terlebih dahulu pada Konsultan pengawas (jika
ada)/Pihak LPSK yang meliputi jenis, kualitas serta
kuantitas dari bahan yang dipesan untuk mendapat
persetujuan.
 Semua bahan-bahan yang akan dipakai dalam
pekerjaan ini harus memenuhi ketentuan-ketentuan
umum yang berlaku di Indonesia, mengenai bahan

46
bangunan serta persyaratan-persyaratannya akan
dicantumkan di dalam pasal-pasal berikut.

Peraturan-peraturan khusus antara lain, yaitu:


- NI-2 (PBI-1991) : Peraturan Beton Indonesia (1991)
- PUBI-1992 : Peraturan Bahan Bangunan di Indonesia
- NI-3 PMI PUBB 1970 : Peraturan Umum Bahan Bangunan di
Indonesia
- NI-4 : Persyaratan cat Indonesia
- NI-5 PKKI : Peraturan Konstruksi Kayu Indonesia
- NI-8 : Peraturan semen Portland Indonesia
- NI-10 : Bata Merah sebagai Bahan Bangunan
- PPI-1979 : Pedoman Plumbing Indonesia
- PUIL-2007: Peraturan Umum Instalasi Listrik
- SNI 3976 : Standar Tatacara Pengadukan dan Pengecoran
Beton
- SNI 3449 : Tatacara Pembuatan Campuran Beton Ringan
dgn Agregat Ringan.
- SNI 2834 : Standar Tatacara Pembuatan Rencana
Campuran Beton Normal
- Standar Industri Indonesia (SII)
- Standar peraturan dari LPSK (jika ada)
a. Air
Air yang digunakan sebagai bahan pengikat spesi
maupun adukan campuran beton adalah air yang
tidak mengandung zat asam, alkali, garam dan
bahan-bahan lain yang dapat merusak mutu
campuran spesi maupun agregat beton.
b. Pasir

47
Pasir untuk adukan spesi maupun beton harus
memenuhi persyaratan sesuai PBI-1971/NI-2,
bebas dari lumpur, tanah, akar tumbuhan,
ataupun bahan lain.
Pasir untuk plesteran disyaratkan pasir yang
halus dengan ketentuan seperti diatas, bila
bercampur dengan agregat yang lebih besar harus
diayak. Pasir untuk campuran beton disyaratkan
pasir dengan butiran kasar atau Pasir Beton.Tidak
diperkenankan memakai pasir yang berasal
dari muara sungai atau yang mengandung air
asin maupun payau.
c. Semen
Semen yang digunakan untuk pekerjaan
pasangan, maupun beton disyaratkan sesuai
ASTM atau SNI -15-0302-1994, Type Semen yang
disyaratkan adalah setara dengan Semen Portland
Type I, jenis A. atau Semen Portland Pozoland
untuk penggunaan umum yang tidak memerlukan
persyaratan khusus.
d. Cat
Cat dasar pada bagian atau bidang kayu yang
baru menggunakan cat dasar meni kayu, Untuk
pengecatan kembali bidang kayu, kusen, pintu dan
jendela menggunakan cat kualitas baik dan
mengkilap, disyaratkan setara Dulux. Penggunaan
Cat untuk tembok dan plafond disyaratkan setara
Dulux.
e. Kayu

48
Bahan kayu yang dipakai untuk penggantian
konstruksi maupun konstruksi baru adalah Kayu
Kelas I setara Bayam. Penggunaan untuk struktur
pendukung, gording, rangka atap juga
menggunakan kayu Kelas II atau setara
Samarinda. Kualitas kayu disyaratkan yang kering,
tidak pecah dan dengan serat yang baik.
 Bilamana akibat satu dan lain hal bahan yang
disyaratkan tidak dapat diperoleh. Penyedia harus
mengajukan usul perubahan pada Konsultan Pengawas
(jika ada)/Pihak LPSK sepanjang mutunya paling tidak
sama dan apa yang disyaratkan.
 Konsultan Pengawas (jika ada)/Pihak LPSK akan
menilai dan memberikan persetujuan secara
tertulis sepanjang memenuhi persyaratan teknis dan
Penyedia diwajibkan untuk sejauh mungkin
mempergunakan bahan- bahan produksi dalam negeri.

Aksebilitas
Dalam melaksanakan pekerjaan dan pengangkutan bahan-
bahan untuk keperluan pekerjaan, Penyedia harus berhati-
hati sedemikian sehingga tidak mengganggu kelancaran
aksebilitas atau menimbulkan kerusakan terhadap bangunan
yang telah ada serta prasarana lainnya.

Cuaca
Pekerjaan harus diberhentikan apabila cuaca tidak
mengijinkan, penundaan pekerjaan tersebut harus tercatat
dan atas instruksi Konsultan Pengawas/pihak LPSK dengan
pertimbangan apabila pekerjaan dilanjutkan dapat

49
mengakibatkan penurunan mutu pekerjaan, misalnya pada
saat pengecoran, plesteran dinding bangunan dll.

Peralatan Survei
Penyedia harus menyediakan peralatan survey yang akan
dipakai, dan alat-alat tersebut harus disetujui oleh pihak
LPSK. Setelah pekerjaan selesai seluruh peralatan
tersebut akan dikembalikan kepada Penyedia.

PEKERJAAN PENDAHULUAN
 Pekerjaan pengukuran, sebelum pekerjaan dimulai
dilakukan pengukuran dengan menggunakan alat ukur
sehingga di dapat hasil ukur yang akurat.
 Penyediaan peralatan P3K yang berisi obat-obatan
yang diperlukan untuk pertolongan pertama pada
kecelakaan
 Air kerja untuk keperluan pekerjaan sehingga tidak
mengalami keterlambatan pelaksanaan dikarenakan
kekurangan air.
 Listrik Kerja digunakan untuk keperluan penggunaan
alat bantu dari mesin seperti mesin pemotong,mesin
bor dll dan penerangan ruangan.
 Konsultan Pengawas (jika ada) atau pihak
L P S K berhak untuk menolak dipekerjakannya
tukang-tukang yang menurut penilaiannya tidak
memiliki keahlian/keterampilan yang cukup untuk
mengerjakan Pekerjaan ini. Dalam hal seperti itu,
Penyedia harus dengan segera mengganti tukang
tersebut dengan tukang-tukang lain yang memenuhi

50
syarat-syarat keahlian/keterampilan. Dalam hal
pengambilan tindakan tersebut, maka tetap akan
menjadi tanggungan Penyedia sepenuhnya.

PEKERJAAN TANAH
a. Pengukuran Tapak Kembali
1. Penyedia diwajibkan mengadakan pengukuran
dan penggambaran kembali lokasi bangunan
dengan dilengkapi keterangan-keterangan mengenai
peil ketinggian tanah, letak pohon, letak batas-batas
tanah dengan alat-alat yang sudah tertera
kebenarannya.
2. Ketidak cocokan yang mungkin terjadi antara
gambar dan keadaan lapangan yang sebenarnya,
harus segera dilaporkan kepada Pemberi
Tugas/Pengawas untuk dimintakankeputusan
3. Penentuan titik ketinggian dan sudut-sudut
hanya boleh dilakukan dengan alat-alat
waterpas/theodolit yang ketepatannya dapat
dipertanggung jawabkan.
4. Penyedia harus menyediakan theodolit/waterpas
beserta petugas yang melayaninya untuk
kepentingan pemeriksaan Pemberi Tugas/Pengawas
selama pelaksanaan proyek
5. Pengukuran sudut siku dengan prisma atau benang
secara azaz segitiga phytagoras hanya diperkenankan
untuk bagian-bagian kecil yang disetujui Pemberi
Tugas/Pengawas

51
b) Tugu Patokan Dasar (Reference Bench Mark)
1. Letak dan tugu patokan dasar ditentukan oleh Pengawas
2. Tugu patokan dasar dibuat dari beton berpenampang
sekurang-kurangnya 10x10cm, tertancap kuat didalam
permukaan tanah sedalam 1 M, dengan bagian yang menonjol
di atas permukaan tanah secukupnya untuk memudahkan
pengukuran selanjutnya dan sekurang- kurangnya setinggi 40
cm di ats tanah
3. Tugu patokan dasar harus dibuat permanent, tidak bisa
diubah, diberi tanda yang jelas dan dijaga keutuhannya
sampai ada instruksi tertulis dari Konsultan Pengawas (jika
ada) /Pihak LPSK/Pengawas untuk membongkarnya.
4. Segala pekerjaan pembuatan dan pemasangan tugu patokan
dasar menjadi tanggung jawab Penyedia
5. Pada waktu pematokan (penentuan) peil dan setiap
sudut-sudut tapak (perpindahan), Penyedia wajib membuat
Shop Drawing terlebih dahulu sesuai keadaan lapangan.

PEKERJAAN GALIAN
a. Lingkup Pekerjaan
1. Pekerjaan ini meliputi penyediaan tenaga kerja, bahan-
bahan/peralatan-peralatan dan alat- alat bantu yang
diperlukan untuk terlaksananya pekerjaan ini dengan baik
2. Pekerjaan ini meliputi seluruh pekerjaan galian pondasi untuk
pekerjaan sub-struktur, seperti yang disebutkan/ditunjukkan
pada gambar atau sesuai dengan Pemberi Tugas/Konsultan
Pengawas

52
3. Juga termasuk didalamnya adalah pekerjaan galian untuk
saluran-saluran dan pekerjaan- pekerjaan lain sesuai gambar
yang memerlukan pekerjaan galian
4. Pembuangan sisa galian ke tempat yang disetujui Pemberi
Tugas/Konsultan Pengawas

b. Syarat-syarat Pelaksanaan
1. Galian untuk reservoir, saluran air, pondasi dan
galian-galian lainnya harus sesuai dengan peil-peil
yang tercantum digambar. Semua bekas-bekas
pondasi bangunan lama, batu, jaringan jalan/aspal,
akar dan pohon-pohon yang terdapat di bagian galian
yang akan dilaksanakan dibongkar dan dibuang
2. Apabila ternyata terdapat pipa-pipa pembuangan,
kabel listrik, telepon dan lain-lain yang masih
digunakan maka Penyedia harus secepatnya
memberitahukan kepada Pemberi Tugas/Konsultan
Pengawas atau kepada penguasa/instansi yang
berwenang untuk mendapatkan petunjuk-petunjuk
seperlunya. Penyedia bertanggung jawab atas segala
kerusakan-kerusakan sebagai akibat dari pekerjaan
galian tersebut
3. Penyedia harus bertanggung jawab untuk
mengambil setiap langkah apapun untuk menjamin
bahwa pekerjaan yang telah sedang berlangsung
tersebut tidak terganggu
4. Apabila ternyata penggalian melebihi kedalaman
yang telah ditentukan maka Penyedia harus
mengisi/mengurug kembali daerah tersebut dengan

53
bahan pondasi yang sejenis untuk daerah ang
bersangkutan. Misalnya untuk daerah pondasi batu
kali, pengisian/pengurug kelebihan galian harus
dilakukan dengan pondasi batu kali
5. Pengisian/pengurukan kembali bekas galian harus
dilakukan selapis demi selapis, dan ditumbuk
sampai padat sesuai dengan yang diisyaratkan
mengenai Pekerjaan Urukan dan Pemadatan.
Pekerjaan pengisian/pengurug kembali ini hanya
boleh dilakukan setelah diadakan pemeriksaan dan
mendapatkan persetujuan tertulis dari Pemberi
Tugas/Pengawas
6. Dasar dari semua galian harus waterpas, bilamana
pada dasar galian masih terdapat akar- akar tanaman
atau bagian-bagian gembur, maka harus digali ke luar
sedangkan lubang- lubang diisi kembali dengan pasir,
disiram dan dipadatkan sehingga mendapatkan
kembali dasar ang waterpas. Pemadatan dilakukan
secara berlapis-lapis dengan tebal lapisan 15 cm lepas,
dengan cara pemadatan dan pengujian sesuai dengan
spesifikasi struktur
7. Semua tanah kelebihan yang berasal dari pekerjaan
galian, setelah mencapai jumlah tertentu harus segera
disingkirkan dari halaman pekerjaan pada setiap saat
yang dianggap perlu dan atas petunjuk Konsultan
Pengawas (jika ada)/Pihak LPSK.
8. Penyedia harus memberikan perlindungan terhadap
benda-benda berfaedah yang ditemui selama
pekerjaan galian. Kecuali ditujukan untuk dipindahkan,

54
seluruh barang-barang berharga yang mungkin
ditemui di lapangan harus dilindungi dari kerusakan,
dan bila sampai menderita kerusakan harus
direparasi/diganti oleh Penyedia atas tanggungannya
sendiri.
9. Jika terdapat kedalaman yang berbeda dari galian
yang berdekatan, maka galian harus dilakukan
terlebih dahulu pada bagian yang lebih dalam dan
seterusnya.

Pekerjaan Urukan Dan Pemadatan


a. Lingkup Pekerjaan
Pekerjaan ini meliputi penyediaan tenaga kerja, bahan-
bahan, peralatan, dan alat-alat bantu yang diperlukan
untuk terlaksananya pekerjaan ini dengan baik. Pekerjaan
ini meliputi semua pekerjaan urukan dan pemadatan
kembali untuk pekerjaan substruktur yang ditunjukkan
dalam gambar atau sesuai petunjuk Konsultan Pengawas

b. Persyaratan Pekerjaan
Bahan untuk urukan tersebut menggunakan material
bekas galian atau dengan mendatangkan dari lokasi lain
dan harus memenuhi persyaratan sebagai berikut:
 Jenis tanah adalah Silty Clay atau pasir urug.
 Tanah harus bersih berarti tidak menggandung akar,
kotoran seperti puing bekas bongkaran, bekas
dinding bata, beton dan bahan organis lainnya.
 Tidak mengandung batuan yang lebih besar dari 10 cm.

55
Konsultan Pengawas (jika ada)/Pihak LPSK akan menolak material
yang tidak memenuhi persyaratan tersebut diatas.

c. Syarat-syarat Pelaksanaan
 Pelaksanaan pengurukan harus dilakukan lapis demi lapis
dengan tebal maksimum tiap- tiap lapisan 20 cm lepas dan
dipadatkan sampai mencapai Kepadatan Maksimum pada
Kadar Air Optimum, dan mencapai peil permukaan tanah
yang direncanakan.
 Pada lokasi yang diurug harus diberi patok-patok, ketinggian
sesuai ketinggian rencana. Untuk daerah-daerah dengan
ketinggian tertentu, dibuat patok dengan warna tertentu
pula.
 Pada daerah yang basah/ada genangan air, Penyedia harus
membuat saluran-saluran sementara untuk mengeringkan
lokasi-lokasi tersebut, misalnya dengan bantuan pompa air.
 Lokasi yang akan diurug harus bebas dari Lumpur atau
kotoran, sampah dan sebagainya.
 Jika tidak ada persetujuan tertulis sebelumnya dari
Konsultan Pengawas maka pemadatan tersebut tidak boleh
dibasahi dengan air. Pemadatan urukan dilakukan dengan
mamakai alat Stemper/Compactor yang disetujui oleh
Konsultan Pengawas.
 Penggalian yang melebihi batas yang ditentukan, harus
diurug kembali sehingga mencapai kerataan yang ditetapkan
dengan bahan urukan yang dipadatkan kecuali untuk daerah
galian pondasi harus mengikuti spesifikasi mengenai
“Pekerjaan Galian”.

56
 Toleransi pelaksanaan yang dapat diterima untuk penggalian
dan pengurukan adalah ± 50 mm terhadap kerataan yang
ditentukan. Semua Drainase darurat harus disetujui oleh
Konsultan Pengawas (jika ada)/Pihak LPSK. Cara kerja yang
dilakukan oleh Penyedia harus disetujui oleh Konsultan
Pengawas (jika ada)/Pihak LPSK.
 Hasil test di lapangan harus tertulis dan diketahui oleh
Konsultan Pengawas (jika ada)/Pihak LPSK. Semua hasil- hasil
pekerjaan harus diperiksa kembali terhadap patok-patok
referensi untuk mengetahui sampai di mana kedudukan
permukaan tanah tersebut.
 Bagian permukaan yang telah dinyatakan padat harus
dipertahankan, dijaga dan dilindungi agar jangan sampai
rusak akibat pengaruh luar misalnya basah oleh air hujan,
panas matahari dan sebagainya. Perlindungan dapat
dilakukan dengan menutupi permukaan dengan plastik.
 Gumpalan-gumpalan tanah harus digemburkan dan bahan
tersebut harus dicampur dengan cara menggaruk atau
sejenisnya sehingga diperoleh lapisan yang kepadatannya
sama. Setiap lapisan harus dikerjakan sesuai dengan
kepadatan yang dibutuhkan dan diperiksa melalui pengujian
lapangan yang memadai, sebelum dimulai lapisan berikutnya.
 Setiap lapisan harus dikerjakan sesuai dengan kepadatan
yang dibutuhkan dan diperiksa melalui pengujian lapangan
yang memadai, sebelum dimulai lapisan berikutnya.
 Bilamana bahan tersebut tidak mencapai kepadatan yang
dikehendaki, lapisan tersebut harus diulang kembali
pekerjaannya atau diganti, dengan cara-cara pelaksanaan
yang telah ditentukan, guna mendapatkan kepadatan yang

57
dibutuhkan. Jadwal pengujian harus diajukan oleh Penyedia
kepada Konsultan Pengawas (jika ada)/Pihak LPSK.
 Setelah Pemadatan selesai, sisa urukan tanah harus
dipindahkan ke tempat tertentu yang disetujui oleh Konsultan
Pengawas (jika ada)/Pihak LPSK.
 Penyedia harus mangadakan drainase yang sempurna
setiap saat. Ia harus membangun saluran-saluran,
memasang parit-parit, memompa dan atau mengeringkan
drainase.

PEKERJAAN URUKAN/LAPISAN PASIR URUG

a. Lingkup Pekerjaan

1. Pekerjaan ini meliputi penyediaan tenaga kerja, bahan-


bahan, peralatan, dan alat-alat bantu yang dibutuhkan
dalam pelaksanaan pekerjaan ini untuk memperoleh hasil
pekerjaan yang baik.
2. Pekerjaan urukan pasir urug/sirtu dilakukan di atas dasar
galian tanah, di bawah lapisan lantai kerja dan digunakan
untuk semua struktur beton yang berhubungan dengan
tanah seperti pondasi, lantai basement, pile cap, dll.

b. Persyaratan Pekerjaan
1. Pasir urug yang digunakan harus terdiri dari butir-butir
yang bersih, tajam dan keras, bebas lumpur, tanah lempung
dan lain sebagainya, seperti diisyaratkan dalam NI-3 (PUBI
tahun 1982) pasal 14 ayat 3.
2. Untuk air siraman digunakan air tawar yang bersih dan tidak
mengandung minyak, asam alkali dan bahan-bahan organis

58
lainnya, serta memenuhi syarat-syarat yang telah ditentukan
dalam NI-3 hal 10. Apabila dipandang perlu, Konsultan
pengawas ( jika ada ) / Pihak LPSK/Pengawas dapat minta
kepada Penyedia, supaya air yang dipakai untuk keperluan ini
diperiksa di laboratorium pemeriksaan bahan yang resmi dan
syah, atau biaya Penyedia
3. Pengendalian seluruh pekerjaan ini harus memenuhi syarat-
syarat yang ditentukan di atas dan harus dengan persetujuan
tertulis dari Konsultan pengawas ( jika ada ) / Pihak
LPSK/Pengawas.

c) Syarat-syarat Pelaksanaan
1. Lapisan pasir urug dapat dilakukan lapis demi lapis
maksimum setiap lapis 10 cm, hingga mencapai tebal padat
yang disyaratkan dalam gambar.
2. Setiap lapis sirtu harus diratakan, disiram air dan/atau
dipadatkan dengan alat pemadat yang disetujui Pengawas.
Pemadatan dilakukan hingga mencapai tidak kurang dari
95% dari kepadatan optimum hasil laboratorium.
Pemadatan harus dilakukan pada kondisi galian yang kering
agar dapat diperoleh hasil kepadatan yang baik.
3. Kondisi galian yang kering tersebut harus dipertahankan
sampai pekerjaan pemadatan yang bersangkutan selesai
dilakukan.
4. Pemadatan harus diulang kembali jika keadaan tersebut di
atas tidak terpenuhi.
5. Tebal lapisan pasir urug minimum 15 cm padat atau
sesuai yang ditunjukkan dalam gambar.Ukuran tebal yang
dicantumkan dalam gambar adalah ukuran tebal padat.

59
6. Lapisan pekerjaan di atasnya, dapat dikerjakan bilamana
sudah mendapat persetujuan tertulis dari Pengawas.

PEKERJAAN URUKAN KEMBALI BEKAS GALIAN PONDASI

a. Lingkup Pekerjaan
Pekerjaan ini meliputi penyediaan tenaga kerja, bahan-bahan,
peralatan, dan alat-alat bantu lainnya yang diperlukan untuk
terlaksananya pekerjaan ini dengan baik.
Pekerjaan ini meliputi semua pekerjaan urukan kembali bekas
galian, yaitu bekas galian pondasi, septictank dan semua
pekerjaan yang ditunjukkan dalam gambar struktur atau sesuai
petunjuk Konsultan pengawas (jika ada ) / Pihak LPSK/Pengawas.
b. Persyaratan Bahan
Persyaratan bahan harus sesuai dengan yang diuraikan dalam
uraian sebelumnya.
c. Syarat-syarat Pelaksanaan
1. Pengurukan tidak boleh dilaksanakan sebelum pondasi atau
lain-lain yang dibangun yang akan ditutup atau
tersembunyi oleh tanah urukan diperiksakan dahulu
oleh Pengawas.
2. Kayu-kayu bekas bekisting atau lain-lain tidak boleh
dibiarkan tertinggal pada waktu pengurukan dilaksanakan,
kecuali jika ada persetujuan dari Pengawas.
3. Syarat-syarat lain harus sesuai dengan yang diuraikan dalam
pekerjaan urukan tanah.
PASANGAN BATU GUNUNG
1. Umum
Bagian ini meliputi penyediaan peralatan, tenaga kerja dan
pemasangan semua pondasi batu gunung dan lainnya yang

60
ukurannya sesuai dengan gambar, kecuali jika ditentukan lain
oleh Konsultan Pengawas.
2. Referensi
Pekerjaan ini harus sesuai dengan :
NI – 3 (1970) Peraturan umum bahan bangunan di indonesia
NI – 8 Peraturan semen portland Indonesia
3. Material
a) Batu
Bahan untuk pondasi batu gunung kecuali
dipersyaratkan lain, harus sesuai dengan P.U.B.I., NI –
3 1970 dan cara pengerjaannya harus dilakukan
menurut cara terbaik yang dikenal umum dilokasi.
Batu gunung harus keras dengan permukaan kasar
tanpa cacat atau retak.
b) Adukan
Adukan yang dipakai terdiri dari campuran 1 pc : 3 pasir.
4. Pelaksanaan
Pekerjaan pemasangan batu gunung dilaksanakan sesuai
dengan ukuran dan bentuk-bentuk yang ditunjuk dalam
gambar. Tiap-tiap batu harus dipasang penuh dengan
adukan sehingga semua hubungan batu melekat satu sama
lain dengan sempurna.
Setiap batu harus dipasang di atas lapisan adukan dan diketok ke
tempatnya hingga teguh. Adukan harus mengisi penuh rongga-
rongga antara batu untuk mendapatkan massa yang kuat dan
integral.

61
PEKERJAAN BETON
Umum
Bagian ini meliputi pengadaan dan pemasangan dari semua
macam beton biasa dengan mutu beton K.250 untuk
struktur utama (kecuali ditentukan lain), beton
bertulang dengan penulangannya, bekisting, finishing dan
pekerjaan-pekerjaan lain sesuai dengan gambar-gambar dan
persyaratan.
Referensi
Kecuali ditentukan lain, maka semua pekerjaan beton harus
mengikuti ketentuan-ketentuan seperti yang tertera dalam:
 NI – 2 (1971) Peraturan beton bertulang indonesia
 NI – 3 (1970) Peraturan umum bahan bangunan di indonesia
 NI – 5 (1961) Peraturan Konstruksi Kayu
 NI – 8 (1972) Peraturan semen portland Indonesia

Material
Semua bahan yang dipergunakandalam pekerjaan ini terdiri dari:
a) Agregat
Agregat harus terdiri dari gradasi-gradasi yang terhalus
sampai kasar dan harus sesuai dengan persyaratan di
dalam NI – 2 Bab 3.3, Bab 3.4 dan Bab 3.5.
Agregat harus disimpan sedemikian rupa sehingga bebas
dari kontaminasi oleh bahan-bahan yang dapat merusak.
Agregat halus (pasir) dan agregat kasar (koral atau split)
harus disimpan dalam tempat-tempat yang terpisah.
b) Semen
Semen yang dipakai harus dari mutu terbaik seperti
disyaratkan dalam NI – 8 Bab 3.2.

62
Penyedia harus mengusahakan agar satu merk semen saja
yang dipakai untuk seluruh pekerjaan beton. Semen ini
harus dibawa ke tempat pekerjaan dalam zak yang tertutup
oleh pabrik dan terlindung.
Penyimpanannya harus dilaksanakan dalam tempat yang
tidak terkena air (dengan lantai terangkat) dan ditumpuk
dalam urutan pengiriman.
Tinggi penumpukan tidak boleh lebih dari 2m. Semen
yang rusak atau tercampur apapun tidak boleh dipakai.
c) Pembesian
Besi penulangan beton harus disimpan dengan cara-cara
sedemikian rupa, sehingga bebas dari hubungan langsung
dengan tanah lembab maupun basah, aspal, oli/minyak
gemuk (fat). Juga besi penulangan harus disimpan
berkelompok berdasarkan ukuran masing-masing.
Besi penulangan harus sesuai dengan persyaratan dalam NI
– 2 Bab 3.7 yang dinyatakan sebagai U – 32 (Besi Ulir),
untuk diameter diatas 13 mm sedangkan untuk dibawah 13
mm adalah U-24 (Besi Polos), sesuai dengan keterangan
pada gambar perencanaan.
Kawat pengikat harus berukuran minimal garis tengah 1
mm seperti yang disyaratkan dalam NI – 2 Bab 3.7.
d) Air
Air yang dipakai untuk pengecoran harus bersih sesuai
dengan persyaratan dalam NI – 2 Bab 3.6.

63
Pelaksanaan
1. Proporsi
Kecuali disebutkan lain, maka campuran beton harus
sedemikian rupa sehingga mencapai kekuatan beton
karakteristik 250 kg/cm2 kecuali disebutkan lain pada gambar.
2. Pengecoran Beton
Kotoran-kotoran dan bahan-bahan lain harus dibuang dari
dalam bekisting. Alat-alat pengaduk (beton molen) dan alat
pembawa harus bersih. Penulangan harus dimatikan pada
posisinya dan diperiksa sebelum pengecoran dilakukan.
Konsultan Pengawas harus menerima pemberitahuan minimal
2 x 24 jam sebelum pengecoran dilakukan, agar pemeriksaan
dan persetujuan dapat diberikan pada waktunya.
Pelaksanaan Pengecoran harus sesuai dengan
persyaratan dalam PBI 1971 kecuali dipersyaratkan lain.
Beton tidak boleh dijatuhkan dari ketinggian lebih dari 1,50
meter dan segera sesudah pengecoran, lapisan-lapisan beton
ini harus dipadatkan.
3. Penyambungan Beton
Sebelum melanjutkan pengecoran pada beton yang telah
mengeras, permukaan yang lama dibersihkan dan dikasarkan,
bekisting harus dikencangkan kembali dan
penyambungannya dengan menggunakan air semen, jika
umur beton lebih dari 3 hari penyambungannya harus
menggunakan Bonding Agent yang disetujui oleh Konsultan
pengawas (jika ada)/Pihak LPSK Pengawas.
4. Slump
Slump yang diizinkan untuk beton dalam keadaan mix yang
normal adalah sesuai dengan PBI 1971 Bab 4.4.

64
Pemakaian nilai slump harus teratur dan disesuaikan dengan
kebutuhannya, misalnya: untuk daerah-daerah yang
pembesiannya rapat menggunakan slump yang tinggi.
5. Lantai Kerja
Semua beton yang berhubungan dengan tanah sebagai
dasarnya, harus diberikan pasir 10 cm dan lantai kerja minimal
5 cm, dengan adukan 1:3:5 di bawah konstruksi beton
tersebut. Sebelum pengecoran lantai kerja dilakukan,
lapisan pasir tersebut harus dipadatkan terlebih dahulu.
6. Kolom dan Balok Praktis
Penyedia harus memberikan/merencanakan kolom-kolom
praktis untuk pemasangan dinding seluas 10 m2 atau dimana
dianggap perlu harus dipasang kolom praktis.
7. Pemeliharaan Beton
Beton yang sudah dicor pada tempatnya harus dijaga agar selalu
lembab dengan jalan menutup beton dengan karung basah atau
menyiram dengan air secara rutin, sehingga beton berumur satu
minggu. Pada umur 24 jam harus dijaga dari air hujan yang deras,
air mengalir, getaran-getaran dan sinar matahari.
8. Masa Pelaksanaan
Selama masa pelaksanaan, mutu beton harus diperiksa secara
kontinyu dari hasil-hasil pemeriksaan benda uji. Paling sedikit
setiap 5 m3 beton harus dibuat benda uji untuk ditest di
laboratorium.
9. Pemeriksaan Lanjutan
Apabila hasil pemeriksaan pada Bab 4.7 PBI 1971 masih
meragukan, maka pemeriksaan lanjutan dilakukan dengan
menggunakan concrete gun atau kalau perlu dengan core

65
drilling untuk meyakinkan penilaian terhadap kualitas beton
yang sudah ada, sesuai pasal 4.8 PBI 1971.
Biaya pekerjaan dalam pasal-pasal ini menjadi tanggungan
Penyedia. Hal-hal yang bersangkutan dengan mutu beton
hendaknya mengikuti NI – 2 pasal yang bersangkutan.
10. Bahan Additive
Pemakaian bahan additive harus disertai percobaan laboratorium
guna mendapatkan hasil yang baik yang disetujui Konsultan
Pengawas (jika ada)/Pihak LPSK Pengawas. Bahan additive ini
harus memenuhi persyaratan ASTM atau JIS.
Bekisting
a. Umum
Bekisting harus direncanakan, dilaksanakan dan diusahakan
sedemikian rupa agar pada waktu pengecoran dan pembongkaran
tidak mengakibatkan cacat-cacat, gelombang-gelombang maupun
perubahan-perubahan bentuk, ukuran-ukuran, ketinggian-
ketinggian serta posisi daripada beton yang dicor. Perencanaan
pelaksanaan, serta pembongkaran bekisting harus sesuai dengan
cara- cara yang disarankan dan kriteria di dalam NI – 2 Bab 5.8.
Permukaan bekisting yang berhubungan dengan beton harus
benar-benar bersih sebelum digunakan.
Penyangga-penyangga harus diberi jarak antara, yang dapat
mencegah defleksi bahan-bahan bekisting. Bekisting beserta
sambungan-sambungannya harus rapat sehingga dapat mencegah
kebocoran-kebocoran adukan selama pengecoran. Lubang-lubang
permukaan sementara harus disediakan di dalam bekisting untuk
memungkinkan pembersihan bekisting.
b. Referensi

66
Seluruh bekisting harus mengikuti persyaratan-persyaratan dalam
normalisasi NI – 2 dan NI – 3.

c. Material
Bekisting untuk Beton.
Seluruh bekisting untuk beton harus terbuat dari papan, Triplex 5
mm dan balok ukuran 5/10 digunakan pada rangka utama dan
kayu 5/7 untuk rangka pengisi, kecuali dipersyaratkan lain oleh
Pengawas.
Sebelum pemasangan bekisting, Penyedia harus memberikan
gambar perencanaan bekisting secara lengkap untuk disetujui
Konsultan Pengawas (jika ada)/Pihak LPSK.
Syarat-syarat yang harus dipenuhi untuk pemakaian bekisting
beton adalah sebagai berikut :
a) Tidak akan mengalami deformasi, sehingga bekisting harus
cukup tebal dan terikat kuat.
b) Harus kedap air dengan menutup semua celah-celah secara
mekanis atau dengan bahan kimia.
c) Tahan terhadap getaran vibrator dari luar maupun dari dalam
bekisting.
d) Permukaan bekisting harus rata dan licin serta diberi releasing
agent yang disetujui oleh Pengawas.
e) Ukuran jarak harus disesuaikan dengan rencana dalam
gambar.
d. Pembongkaran Bekisting
Bekisting harus dibongkar dengan cara sedemikian rupa sehingga
dapat menjamin keselamatan penuh atas struktur-struktur yang
dicetak dengan memperhatikan persyaratan-persyaratan minimum
sebagai berikut: Bagian struktur beton vertikal boleh dibongkar

67
bekistingnya setelah 7 hari, dengan syarat bahwa betonnya telah
cukup keras dan tidak cacat karena pembongkaran tersebut.
Bagian struktur beton yang disangga dengan penumpu tidak boleh
dibongkar, sebelum betonnya mencapai kekuatan yang cukup
untuk menyangga beratnya sendiri dan beban-beban pelaksanaan
atau beban-beban lain yang akan menimpa bagian struktur beton
tersebut.
Dalam hal apapun bekisting pada jenis struktur ini tidak boleh
dibongkar sebelum berumur 14 hari, demikian juga bekisting-
bekisting yang dipakai untuk mematangkan (curing) beton tidak
boleh dibongkar sebelum beton ditentukan matang.
e. Contoh-contoh
Sebelum pelaksanaan pemasangan, lebih dahulu Penyedia harus
memberikan contoh-contoh material yang akan dipakai guna
mendapatkan persetujuan Pengawas.
f. Koordinasi dengan Pemasangan Instalasi
Sebelum pengecoran dimulai, Penyedia harus sudah
mengkoordinasikan pemasangan letak-letak instalasi listrik,
plumbing dan lain-lain.
Persyaratan Pra-Konstruksi
1. Penyedia wajib memberikan pemaparan produk sebelum
pelaksanaan pemasangan rangka atap baja ringan, sesuai dengan
RKS (Rencana Kerja dan Syarat).
2. Produk yang dipaparkan sesuai dengan surat dukungan dan
brosur yang dilampirkan pada dokumen tender.
3. Penyedia wajib menyerahkan gambar kerja yang lengkap
berserta detail dan bertanggung jawab terhadap semua ukuran-
ukuran yang tercantum dalam gambar kerja. Dalam hal ini

68
meliputi dimensi profil, panjang profil dan jumlah alat sambung
pada setiap titik buhul.
4. Perubahan bahan/detail karena alasan apapun harus diajukan
ke Konsultan Pengawas, Konsultan Perencana dan Pihak
Konsultan Pengawas (jika ada)/Pihak LPSK untuk mendapatkan
persetujuan secara tertulis.
Persyaratan Pelaksanaan
1. Pembuatan dan pemasangan kuda-kuda dan bahan lain terkait,
harus dilaksanakan sesuai gambar dan desain yang telah dihitung
dengan aplikasi khusus perhitungan baja ringan sesuai dengan
standar perhitungan mengacu pada standar peraturan yang
berkompeten.
2. Semua detail dan konektor harus dipasang sesuai dengan gambar
kerja.
3. Pihak Penyedia harus menyiapkan semua struktur balok
penopang dengan kondisi rata air (waterpas level) untuk
dudukan kuda-kuda sesuai dengan desain sistem rangka atap.
4. Pihak Penyedia harus menjamin kekuatan dan ketahanan semua
struktur yang dipakai untuk tumpuan kuda-kuda. Berkenaan
dengan hal itu, pihak konsultan ataupun tenaga ahli berhak
meminta informasi mengenai reaksi-reaksi perletakan kuda-kuda.
5. Pihak Penyedia bersedia menyediakan minimal 8 (delapan) buah
genteng yang akan dipakai sebagai penutup atap, agar pihak
penyedia konstruksi baja ringan dapat memasang reng dengan
jarak yang setepat mungkin, dan penyediaan genteng tersebut
sudah harus ada pada saat kuda-kuda tiba dilokasi proyek.

69
Jaminan Struktural
Jaminan yang dimaksud di sini adalah jika terjadi deformasi yang
melebihi ketentuan maupun keruntuhan yang terjadi pada struktur
rangka atap Baja Ringan, meliputi kuda-kuda, pengaku-pengaku dan
reng.

PEKERJAAN DAK BETON

Pekerjaan Atap
1. Umum
a. Sebelum memulai pekerjaan pemasangan penutup
atap, Penyedia harus memeriksa terlebih dahulu
apakah seluruh rangka telah selesai dipasang dan
sudah sesuai menurut ketentuan dalam persyaratan
teknis ini.
b. Pelaksana pekerjaan ini baru dapat dimulai setelah diijinkan
Konsultan Pengawas.
c. Lingkup Pekerjaan
Meliputi penyiapan bagian-bagian yang akan
dipasang, menyediakan material beton, bekisting,
besi wiremesh dan alat-alat bantu.
2. Bahan
Bahan yang digunakan adalah:
1. Bekisting dari triplek ukuran sekurangnya 5mm dan kayu
2. Besi begel ukuran 10mm (bukan ulir) sebagai bahan
pembuatan wiremesh
3. Jarak antar wiremesh 20cm dengan 2 lapis
4. Beton mixer dengan kekuatan sekurangnya 250K
5. Acian semen

70
3. Pelaksanaan
a. Sebelum pemasangan, semua material harus disetujui
Konsultan Pengawas.
b. Dalam pelaksanaan pekerjaan ini, Penyedia harus
menempatkan tenaga ahli/supervisi dari pabrik pembuat.
Biaya untuk hal ini ditanggung Penyedia.
c. Pekerjaan dak beton konvensional diawali dengan pembuatan
cetakan (bekisting) dan pembesian balok serta pelat beton.
Selain untuk menopang pembesian dan menampung adonan
beton yang akan dituang atau cor, bekisting juga memberi
bentuk. Bekisting bisa dibuat dari papan, multipleks, atau
bahan lain yang sesuai, dan ditopang oleh perancah
(scaffolding) sebagai penyangga sementara
d. Setelah pekerjaan persiapan selesai harus dilakukan
pemeriksaan ulang pada bekisting, meliputi dimensi, elevasi,
kelurusan, kerapatan sambungan), dan juga pemeriksaan
tulangan (dimensi, jumlah dan jarak besi tulangan, kekuatan
bendrat). Untuk memeriksa elevasi bisa dibantu theodolit dan
waterpass
e. Adukan beton yang akan dicor dengan menggunakan beton
mixer dengan kekuatan sekurangnya 250K
f. Jeda waktu untuk pengecoran satu bidang sebaiknya dihindari,
karena berpotensi memicu terjadinya retak/kebocoran. Jika
terpaksa menghentikan pengecoran, sebaiknya pada posisi ¼
bentang (dihitung dari tumpuan). Jika mungkin, pengecoran
baik dilakukan malam hari untuk mengantisipasi sinar matahari
yang ekstrem. Pengecoran siang hari akan baik bila dilakukan di
bawah terpal pelindung

71
g. Pembongkaran bekisting sebaiknya dilakukan setelah 4-21 hari,
seturut proses pengerasan dan pengeringan beton. Sebelum
kering sempurna, sebaiknya dak beton tidak dibebani
berlebihan. Dak beton yang difungsikan sebagai atap, idealnya
dilapisi bahan waterproofing penutup pori-pori beton untuk
mengantisipasi rembes atau bocoran.

PEKERJAAN DINDING DAN PLESTERAN


Pekerjaan Dinding
1. Lingkup Pekerjaan
a. Pengadaan tenaga kerja, peralatan, dan bahan-bahan
yang diperlukan untuk pekerjaan pasangan bata
sesuai gambar rencana dan RKS.
2. Contoh-contoh Bahan
a. Sebelum memulai pekerjaan, Penyedia terlebih
dahulu harus menyerahkan contoh-contoh bahan
yang akan digunakan guna mendapatkan persetujuan
dari Pengawas.
Bahan
Bahan yang digunakan adalah:
Blok beton Hebel B-2, adukan pasir dan semen dengan perbandingan
1:4, dan acian semen
Adukan pemasangan Blok beton Hebel B-2 dengan menggunakan
mortar khusus, yaitu semen instan :
 Untuk Pengikat antara Blok Hebel dengan lantai, sloof,
kolom praktis, ringbalk praktis menggunakan PRIME MORTAR
– PM 200 yaitu Ready Mix Plaster.
 Untuk Pengikat/Siar antara Blok Hebel menggunakan PRIME
MORTAR – PM 110 yaitu Thin Bed Mortar.

72
Pelaksanaan
Semua pasangan blok hebel dibuat dengan ketebalan yang ditentukan
sesuai spek bahan, Pekerjaan dinding harus dipatok (diukur) dan
dibangun sesuai ukuran, ketebalan dan ketinggian yang tercantum
dalam gambar-gambar serta memberi bidang yang rata.
Siar-siar untuk mengikat lantai, sloof, kolom praktis, ringbalk praktis
menggunakan PRIME MORTAR –PM 200 yaitu Ready Mix Plas yang
mempunyai tebal 10 – 20 mm yang merata serta padat.
Untuk Pengikat/Siar antara Blok Hebel menggunakan PRIME
MORTAR – PM 100 yaitu Thin Bed Mortar, dengan tebal aplikasi 2
– 3 mm.
Pengerukan Siar:
Semua dinding siar harus dikeruk dengan menggunakan pecahan
blok hebel atau dengan papan amplas, untuk menjamin melekatnya
plesteran ke dinding dengan baik.
Perlindungan :
Pada tahap pelaksanaan pekerjaan dinding yang tidak
terlindung, bilamana hujan perlu diberi perlindungan pada bagian
atasnya.
Pemeliharaan :
Dinding harus dijaga agar tetap lembab selama min. 7 hari setelah
dilaksanakan.
Angker dan Ikatan :
Angker-angker yang dijelaskan dalam bestek ini harus tertanam
dalam pertemuan blok hebel dengan beton setelah membersihkan
angker-angker tersebut dari kerak-kerak, karat dan kotoran lainnya.
Pemasangan angker dipasang setiap 3 (tiga) susun blok hebel
sampai ke batas ringbalk yang telah ditentukan.

73
Permukaan beton harus dibuat kasar pada sambungan-sambungan
tegak dengan tembok supaya terjadi ikatan bagi adukan pekerjaan
pasangan.
Kolom Praktis
Pada tiap jarak 4 meter dalam blok hebel (atau pada sambungan-
sambungan antara, sehingga luas bidang blok hebel max. 12 m2) dan
pada semua pertemuan dinding, harus dibuat kolom praktis dari
beton dengan lebar 15 cm setebal blok hebel. Kolom ini harus
dibuat sesuai dengan kemajuan pekerjaan blok hebel, diberi
tulangan pokok 4 dia. 8 mm serta beugel dia. 6 pada tiap jarak 20 cm,
atau seperti tercantum dalam gambar.
Pekerjaan Plesteran
1. B a h a n.
a. Adukan untuk plesteran blok hebel menggunakan mortar
khusus, yaitu semen instan PRIME MORTAR – PM 210 yaitu
Ready Mix Plaster.
b. Adukan untuk acian menggunakan PRIME MORTAR – PM 310
2. P e r s i a p a n
Permukaan dinding blok hebel harus diberi waktu cukup
untuk mengering dan semua pipa, saluran-saluran harus sudah
terpasang pada tempatnya. Siar-siar sudah harus dikeruk.
3. Pelaksanaan.
Tebal plesteran 10 mm (sekurangnya) dan harus menghasilkan
permukaan sesuai persetujuan Pengawas. Harus dipasang aduk-
adukan patokan untuk mendapatkan permukaan yang rata.
Plesteran diratakan dengan menggunakan papan kayu yang
lurus. Plesteran harus dijaga agar tetap dalam keadaan lembab
selama minimum 7 hari setelah dipasang. Pembasahan
permukaan plesteran harus segera dimulai pasa saat plesteran

74
mulai mengeras untuk mencegah terjadinya cacat-cacat pada
keadaan cuaca panas plesteran harus dilindungi terhadap
pengeringan yang tidak merata atau berlebihan.
4. Memperbaiki dan Membersihkan.
Penyedia wajib memperbaiki plesteran dinding yang kurang
sempurna dengan cara membuang bagian-bagian tersebut dengan
bentuk persegi panjang serta diplester kembali.
Pekerjaan plesteran yang telah selesai harus bebas dari retak-
retak, noda dan cacat lain.
Pada waktu-waktu tertentu selama pelaksanaan, dan bila
pekerjaan telah selesai semua plesteran yang tampak harus
dibersihkan dari kotoran-kotoran akibat pekerjaan.
PEKERJAAN LANTAI
Pekerjaan Lantai Bawah
Bahan yang digunakan adalah:
1. Semen adukan pasir dengan perbandingan 1:6
2. Besi beugel minimal ukuran 10mm (bukan ulir)
3. Beton Mixer dengan kekuatan sekurangnya 250 K
4. Wiremesh jarak 20cm dua lapis
Pelaksanaan
1. Sebelum pemasangan, semua material harus disetujui konsultan
pengawas.
2. Dalam pelaksanaan pekerjaan ini, Penyedia haru menempatkan
tenaga ahli/supervisi dari pabrik pembuat. Biaya untuk hal ini
ditanggung Penyedia.
3. Pekerjaan lantai beton konvensional diawali dengan pembuatan
wiremesh dua lapis

75
4. Pengecoran lantai bawah dengan menggunakan beton mixer
dengan sekurang-kurangnya 250 K, dan untuk memeriksa elevasi
bisa dibantu theodolit dan waterpass
Pekerjaan Pondasi Genset
Bahan yang digunakan adalah:
1. Semen adukan pasir dengan perbandingan 1:6
2. Besi ulir dengan ukuran 16 mm
3. Beton Mixer dengan kekuatan sekurangnya 250 K
4. Bekisting Batako atau triplek ukuran minimal 5mm
Pelaksanaan
1. Sebelum pemasangan, semua material harus disetujui konsultan
pengawas.
2. Dalam pelaksanaan pekerjaan ini, Penyedia harus
menempatkan tenaga ahli/supervisi dari pabrik pembuat. Biaya
untuk hal ini ditanggung Penyedia.
3. Pekerjaan pondasi genset diawali dengan anyaman besi ulir
16mm pada area pondasi genset
4. Pembuatan bekisting sebagai pembatas dari pondasi genset
5. Pengecoran lantai bawah dengan menggunakan beton mixer
denga kekuatn sekurangnya 250 K, dan untuk memeriksa elevasi
bisa dibantu theodolit dan waterpass
PEKERJAAN PENGECATAN
1. Bahan dan Syarat-syarat:
Semua bahan cat harus dari penyalur yang disetujui Konsultan
Pengawas. Pengerjaan pengecatan harus mengikuti petunjuk-
petunjuk dari pabrik yang bersangkutan. Sebelum pengecatan,
maka cat dalam kaleng harus diaduk secara baik sebelum
dituangkan dalam tempat cat yang disediakan. Tanpa petunjuk

76
dari pabrik maka penggunaan zat-zat pengering dan lain- lain
tidak dibenarkan.
2. Jenis Bahan
Cat tembok untuk tembok dalam adalah cat jenis emulsi merk
mowilex/dulux dan luar jenis emulsi dengan kandungan Acrylic
100% Weathercoat merk Mowilex/Dulux/Setara.
3. Daftar Bahan
Secepat setelah penandantanganan kontrak, tetapi paling
lambat 2 bulan sebelum pekerjaan cat dimulai, Penyedia wajib
menyerahkan kepada Konsultan Pengawas
4. Pemilihan Warna
Semua jenis warna yang dipakai akan ditentukan dan disetujui
oleh MK/Konsultan Pengawas.
5. Persiapan
Sebelum pekerjaan pengecatan dimulai, lantai-lantai harus
dicuci serta debu sedapat mungkin dicegah. Semua permukaan
yang akan di cat harus dipersiapkan sesuai dengan bestek
tertulis dan sesuai dengan persyaratan pabrik.
6. Pekerjaan Permulaan
Cat Dinding Tembok;
Plesteran harus diberi kesempatan yang maksimum untuk
mengering sebelum pengecatan dimulai. Semua plesteran atau
dasar semen yang cacat harus dibuang dan diperbaiki dahulu
dengan plesteran yang sejenis. Retak-retak kecil harus ditutup
sedang retak besar harus dibongkar dan diisi kembali rata
permukaan sekitarnya. Sebelum permukaan diberi satu cat
dasar (tahan alkali), semua kotoran pada permukaan harus
dibersihkan. Sebaiknya jangan menggunakan plamur setelah
acian dilaksanakan.

77
Pengecetan (Finishing);
Dua Lapis cat emulsi untuk dinding dalam dan luar, untuk
dinding harus menggunakan cat khusus untuk luar
PEKERJAAN PINTU DAN KISI-KISI
Pekerjaan Pintu
Bahan yang digunakan adalah:
1. Besi Plat dengan ukuran minimal 1.8mm
2. Cat warna abu-abu
Adapun BOQ dari pekerjaan pengadaan Genset dan Pembuatan Rumah
Genset tsb adalah sebagai berikut:

No Description Qty Unit

A PEKERJAAN PRA POJECT


PEKERJAAN PERSIAPAN

1 Mobilisasi Alat dan Bahan Ls


1,00
2 Survey, Ploting dan Marking Area Ls
1,00
3 Kebersihan dan Keamanan Kerja Ls
1,00
4 Proteksi dan Alat Bantu Kerja Ls
1,00
5 Desain dan Shopdrawing Ls
1,00

B PEKERJAAN GENSET 2 x 300 kva

1 Genset 300 kva unit


2,00
Kapasitas : 300 kVA/240 kW
Type : Silent
Rate Speed : 1500 RPM
Voltage : 220/380 V
Tangki BBM builtin : min. 500 Lt
Output Frequency : 50 Hz

2 Tangki BBM dan Pondasi : 2.000 Lt unit


1,00
3 Instalasi pemipaan Ls

78
1,00

4 Grounding Genset Ls
1,00
5 Test & Commisioning Ls
1,00

C PEKERJAAN RUMAH GENSET


1 Pekerjaan Tanah
Galian tanah untuk pondasi 22,54 m3
Urukan tanah kembali untuk pondasi 7,51 m3
Urukan tanah t= 20cm dari level existing + pemadatan 112 m3
2 Pekerjaan Pondasi Beton

Pondasi batu kali m3


18,11
Pondasi plat setempat (cakar ayam) u/ kolom ttk
15,00
Pondasi rolaq bata m
3,00
Sloff beton 15 x 18 cm, tul.6 besi 14 mm, ring 10mm -
m3
15cm 1,24

Kolom beton 25x25, tul.12mm, ring 8mm - 20cm (K2) -


m3
finish plester 3,64

Balok beton 30x15cm tul. 12mm, ring 8mm - 20cm (B3) m3


3,79
Cor plat beton T12cm, tul.8mm x 2 lapis net 15x15cm m3
13,54
Floor Lt. kerja T10cm + Wiremesh M6 double m²
112,00
3 Pekerjaan Pemasangan Dinding

Pemasangan dinding hebel m²


174,08
Plester + aci m²
348,16
Peredam - glas wuul tebal 5 cm dan kain m²
296,00
4 Pekerjaan Atap

Water proofing dak beton m2


113,00
Instalasi air hujan pipa PVC 3" ex Wavin m
24,00
Instalasi air hujan pipa PVC 4" ex Wavin m
39,00
5 Pekerjaan Pintu
Kusen & Pintu besi double plat 2mm + handle + kunci, 2x
unit
2.2 mtr 1,00

79
6 Pekerjaan Finishing

Cat dinding luar m2


179,60
Cat dinding dalam ex. Metrolite m2
174,08
7 Pekerjaan Electrical

Exhaust Fan 25 inch unit


2,00
Panel exhaust fan dengan push button on-off unit
1,00
Instalasi lampu dan saklar ttk
2,00
C PEKERJAAN PANEL GENSET & INSTALASI
Pengadaan & Pemasangan Panel Synkronisasi Genset 2 x 300
1 Unit
kva 1,00

Pengadaan Dan Pemasangan Kabel Genset ke Panel


2 mtr
Synkronisasi 20,00
Spek :
- Kabel NYY 4 x 1 x 150 mm c/w aksesoris
Pengadaan Dan Pemasangan Kabel dari Panel Synkronisasi Ke
3
Panel ATS R.Data Center
Spek :

- Kabel NYY 4 x 2 x 1 x 150 mm c/w aksesoris mtr


100,00
- Kabel NYA 2 x 1 x 95 mm ( Grounding ) mtr
100,00
4 Pengadaan Kabel Tray di Ruang Genset ls
1,00

5 Pengadaan Pipa HDPE Spiral/Corrugated Double Wall 150 mm ls


1,00

6 Pengadaan Material bantu Unit


1,00
( kabel Skun, Vynil, Kabel Tiest, dll )

7 Pembuatan Galian Jalur Kabel dan Pengurukan kembali ls


1,00
- Kedalaman kabel ± 60 cm

8 Pengadaan Kabel Tray utk jalur kabel di Gedung LPSK Ls


1,00
9 Pemindahan Hydran Box dan Hydran Pillar ls
1,00

80
6.1.5 Sistem Pencegah Kebakaran (Fire Supression System)
Fire Suppression system yang terdiri atas Cylinder dan gas, Smoke detector,
Nozzle, Control panel alarm extinguisher, sign lamp, Bell alarm, Manual
release, Abort switch harus sesuai dengan spesifikasi teknis, Sistem pencegah
kebakaran (fire suppression system) yang ditawarkan harus berstandar NFPA
2001 Standard on Clean Agent Fire Extinguishing Systems dengan memenuhi
ketentuan berikut :
a. Pemasangan dan pengadaan Fire Suppression system yang terdiri atas
Cylinder dan gas, Smoke detector, Nozzle, Control panel alarm
extinguisher, sign lamp, Bell alarm, Manual release, Abort switch harus
sesuai dengan spesifikasi teknis.
b. Menjamin peralatan dapat berfungsi dengan baik dan dapat digunakan
dengan optimal sesuai fungsinya.
c. Melakukan test discharge dengan gas N2 pada perangkat Fire suppression.
d. Melakukan simulasi uji sistem.
e. Melakukan Test Interlock dengan perangkat pendukung Data center
lainnya, system AC dan Access control.
f. Penyedia harus memberikan perhitungan hidrolik sesuai dengan kapasitas
dan ukuran yang dibutuhkan

 Tipe Fire Suppression System: Extinguished Fire System


a. Main Equipment
• Cylinder Cap. 52 Ltr
• c/w Hose 2" & Bracket 52 Ltr
• c/w Electrical Solenoid Actuator,
• c/w Manual Actuator,
• c/w Discharge Pressure Switch,
• c/w Clean Agent 135 Kg
• Discharge Nozzle 360˚
b. Detection NOTIFIER
 Conventional. Releasing Control Panel c/w Battery
 Conventional. Photoelectric Smoke Detector (FSS)
 Conventional. Photoelectric Smoke Detector (FA)
 Alarm Bell
 Horn c/w strobe (FSS)
 Horn c/w strobe (FA)
 Manual Release + Abort Switch (FSS)

81
 Addressable Manual Call Point (FA)
 Addressable Manual Call Point (FA)
 Gas Discharged Sign Lamp
 Key Maintenance Switch
 Zone Module
 Control Module
 Addressable Releasing Module
 Mini Monitor Module
 Relay Module
 Junction Box
 Portable Clean Agent SV36 Cap 8,4 Lbs
c. Material Installation
 Cable Power NYA 2 x 1.5 mm, PVC High Impact Conduit
 Fitting Class 3000 PSI, Hanger & Support
 Blacksteel Seamless Pipe Sch-40, Red Paint
1.1 Panel Kontrol
Panel kontrol yang dipakai haruslah type panel yang memang
didesign sebagai releasing panel dengan approval UL-864, EN-54,
GOST, IS 1220 dan CE, ditunjukkan dalam brosur dan spesifikasi
teknis bahwa panel tersebut memang diperuntukkan sebagai
releasing panel.
Panel Kontrol harus memiliki sistem indikasi trouble yang bisa
ditampilkan dalam bentuk LED, maupun dalam bentuk text di LCD
display.
1.2 Instalasi Peralatan Deteksi, Aktuasi, Alarm dan Kontrol
 Kabel instalasi kabel adalah jenis FRC untuk Fire Suppresion
System, Sounder, Alarm Bell, Gas Discharge dan Evacuate
Sign dan jenis AWG 18 untuk Detector, Modul, MCP, dll
 Pipa & fleksibel conduite pelindung kabel instalasi dan
accessories lainnya adalah jenis PVC high impact yang telah
memenuhi persyaratan BS 6099, BS 4607, LMK, PLN.
 Produksi: EGA, Waler, Marshall Tuplex.
Penyedia Barang/Jasa harus menawarkan Produk dengan Surat Dukungan resmi
dari Agent Tunggal Indonesia dengan melampirkan Surat Keterangan Pengetesan

82
Alat Pemadam dari Dinas Penanggulangan Kebakaran dan Penyelamatan
Provinsi DKI Jakarta.
Produk harus memenuhi kriteria Standar dan Peraturan sebagai berikut:
- NFPA 2001: Standard on Clean Agent Fire Extinguishing System.
- Design and installation practices set forth by system manufacturer

Volume Pekerjaan Fire Supression

NO. DESCRIPTION VOL UNIT

1 DATA HALL, UTILITY ROOM & MMR ROOM


A EQUIPMENT
A.1 CYLINDER FOR ABOVE RAISED FLOOR
1 Cylinder 600 lbs, 3" valve 1 unit
2 Gas (ex Dupont) 187 kg
3 Cylinder Strap: 600 lbs (2 sets) 1 unit
4 Electric Control Head for 600 & 900 cylinder 1 unit
5 Discharge Pressure Operated Switch (NFPA2001) 1 unit
6 Discharge Nozzle, Brass 4 unit

A.2 CYLINDER FOR BELOW RAISED FLOOR


1 Cylinder 125 lbs, 1 1/2" valve 1 unit
2 Gas (ex Dupont) 25 kg
3 Cylinder Strap: 125 & 200 lbs 1 unit
4 Flexible Discharge Hose 1 1/2" x 24" 10-125 lbs 1 unit
5 Electric Control Head, Stackable, Expl. Proof 1 unit
6 Lever Operated Control Head (Manual Discharge) 1 unit
7 Discharge Pressure Operated Switch (NFPA2001) 1 unit
8 Discharge Nozzle, Brass 4 unit

B DETECTION & CONTROL SYSTEM


1 AEGIS Control Panel c/w battery 1 unit
7 init., 3 noti., 2 rela. 4 relay
2 Photoelectric Smoke Detector w/base 16 unit
3 Dual Action Manual Pull Station c/w cover 2 unit
4 Suppression Abort Station c/w cover 2 unit
5 Multi-tone w/Strobe 24VDC c/w backbox 2 unit
6 Fire Alarm Bell 6" 24VDC c/w mounting 3 unit
7 Alarm Sign "Evacuate Area" (LED) 3 unit

83
8 Alarm Sign "Gas Discharge" (LED) 2 unit

C Installation Material 1 lot


Black steel Seamless Pipe Schedule 40
Pipe Fitting Class 300
Power Cable NYA 1x1.5mm
High Impact PVC Conduit 20mm
Hanger & Support
Interlock to ac
Terminasi , Program ,Testing & Comissioning 1 lot

No Description Unit Qty

G Pengadaan dan Pemasangan Fire Suppresion Aerosol


A. Main & Support Equipment
A.1 Panel Control Fire Alarm
1 Telefire Analog Addressable Control Panel Single Loop unit 1
2 TCP/IP Module unit 1
3 Remote Panel and Announciator unit 1
4 Analog Addressable Manual Fire Alarm Call Point unit 2

RUANG NOC
1,1 NOC ROOM (ROOM COVERAGE)
a. Generator Aerosol Kapasitas 3000 gram unit 4
b. Three-Channel Input/Output Module (incl. Enclosure ) unit 4
c. Adaptor for Generator Aerosol unit 1
d. Analog Addressable Photoelectric Smoke Detector unit 1
e. Analog Addressable Rate of Rise Heat Detector unit 1
f. Analog Addressable Manual Extinguishing Call Point unit 1
g. Abort Switch unit 1
h. Alarm Notification Horn / Strobe unit 1
i. Alarm Bell unit 1
j. Illuminated Announcing Sign for Evacuate Area Sign unit 1
k. Illuminated Announcing Sign for Gas Discharge Sign unit 1

2,1 Ruang Tunggu (ROOM COVERAGE)


a. Generator Aerosol Kapasitas 3000 gram unit 1
b. Three-Channel Input/Output Module (incl. enclosure) unit 4
c. Adaptor for Generator Aerosol unit 1
d. Analog Addressable Photoelectric Smoke Detector unit 1
e. Analog Addressable Rate of Rise Heat Detector unit 1
f. Analog Addressable Manual Extinguishing Call Point unit 1
g Abort Switch (blue) (incl. cover) unit 1

84
h. Alarm Notification Horn / Strobe unit 1
i. Alarm Bell unit 1
j. Illuminated Announcing Sign for Evacuate Area Sign unit 1
k. Illuminated Announcing Sign for Gas Discharge Sign unit 1

3,1 STAGING ROOM (ROOM COVERAGE)


a. Generator Aerosol Kapasitas 3000 gram unit 2
b. Three-Channel Input/Output Module (incl. enclosure) unit 4
c. Adaptor for Generator Aerosol unit 1
d. Analog Addressable Photoelectric Smoke Detector unit 1
e. Analog Addressable Rate of Rise Heat Detector unit 1
f. Analog Addressable Manual Extinguishing Call Point unit 1
g Abort Switch (blue) (incl. cover) unit 1
h. Alarm Notification Horn / Strobe unit 1
i. Alarm Bell unit 1
j. Illuminated Announcing Sign for Evacuate Area Sign unit 1
k. Illuminated Announcing Sign for Gas Discharge Sign unit 1

B. Material Instalasi & Jasa


1 Installation Material Lot 1
2 Accessories Lot 1
3 Labour Cost Lot 1
4 Testing & Commissioning Lot 1
5 Delivery Unit, Material & Transport Teknisi Lot 1

6.1.6 Sistem Pendingin Presisi


Spesifikasi teknis PAC
PAC yang ditawarkan harus memenuhi spesifikasi berikut :

Indoor Unit & Outdoor Brand : Eropa atau Amerika


Kapasitas :
Cooling Capacity : Mininum 54.9 kW / 187,318.80
BTU/h
Sensible Capacity : Minimum 47 kW / 160,364.00 BTU/h
Airflow m3/H : Minimum 11,500
Energy Efficiency Ratio (EER) : 3.86
Sensible Heat Ratio : 86%
Sound Pressure Level dB(A) : maksimum 62
Rincian Kelengkapan Perangkat :

85
Indoor + Outdoor Unit (Down Flow)
Compressor : Kompresor dengan 3 Fase Sistem
Hermetic Scroll
Cooling Coil : Fins aluminium dilengkapi dengan
fitur hydrophilic
Humidifier : Model Flooded-elctrode
Dehumidifier:
Electrical Heater : Fin dengan resistansi baja tahan
karat elektrik dengan standard AISI
321 dengan safety thermostat.
Fans : Sistem INVERTER dan kontrol
elektronik terintegrasi, jarak
peredaman suara (-4 dB (A))
Sensor : Temperature & Humidity Sensors
Refrigerant : R-410A
Ambient Temperature : > 35°C (outdoor)
Reheat : Power terbagi atas dua langkah.
Filter : Memiliki standard M5.
Microprocessor Control : Terdapat mikroprosesor untuk
pengelolaan lengkap unit Precision Air
Conditioning
Outdoor : Air-cooled Remote Condenser
Panels : Panel ganda, Panel closure dicat
dengan polyester dengan standard
RAL 7016.
Height : 1,980 mm (plus min 15%)
Length : 1,350 mm (plus min 15%)
Width : 890 mm (plus min 15%)
Electrical : Power 400/380 V, 3 Ph, N/50 Hz
Input Current Unit (A) : maksimum 57 A
Power input unit (kW) : maksimum 35 kW
spesifikasi teknis AC Split
 Jenis Split
 Kapasitas 2PK
 Hemat Listrik
 Swing Fitur
 Termasuk Pipa penghubung indoor dan outdoor

86
Ketentuan Instalasi
 PAC disetting untuk beroperasi bergantian secara otomatis (2 running dan 1
standby) sehingga ruangan Data Center selalu dalam kondisi suhu kerja yang
ideal.
 PAC di seting untuk beroperasi secara redundant, jika salah satu PAC
mengalami kerusakan, fungsinya otomatis di gantikan oleh PAC lainnya.

Volume Pekerjaan Sistem Pendingin Presisi

No Description Qty Unit

E Pekerjaan Air Conditioner (AC)


1 Pengadaan AC Presisi 3 unit
Cooling Capacity: 54,9 kw
Sensible Capacity: 47,0 kW
Down Flow Type
Electrode Steam Humidifier
LCD Display
Micoprosessor Controls
Standart M5 Filtration
Variable Refrigerant - Flow ( VRF )
Refrigerant : R - 410A
Built-In Control for Cooling, Humudity and Heating

2 - Material Instalasi dan pemasangan serta testing 1 paket


a. Pemipaan
b. Drainage
c. Mounting & Hanger
d. Electrical Works
e. Humidifier
f. Refrigerant
g. Support Material & Accessories
h. Testing and Commissioning

3 Pengadaan AC Split Inverter 2 Pk beserta instalasinya 4 unit


(untuk Ruangan Command Center)
4 Pengadaan AC Split Inverter 1 Pk beserta instalasinya 2 unit
(untuk Ruangan NOC)
5 Pengadaan AC Split Inverter 1 Pk beserta instalasinya 2 unit
(untuk Staging Room)

87
6.1.7 Infrastruktur Pendukung data center dan Comand Center
6.1.7.1 Infrastruktur Pendukung Data Center
Infrastruktur pendukung data center terdiri dari Wall Display NOC, EMS
dan Rack server. Wall Display NOC yang ditawarkan harus memenuhi
spesifikasi berikut :

No Description Spesifikasi
1 Screen Size 55” class (55” diagonal)
Panel Technology IPS
Aspect Ratio 16:9
Native Resolution 1920 x 1080 (FHD)
Maksimum Bezel 0,4mm All Sides
Brightness 500cd/m
Contrast Ratio 1,400:1
Viewing Angle (H x V) 178 x 178
Color Depth 1.06 Billion
Video Wall 55"
Response Time 8ms (G to G BW)
Running Time 24Hrs
Orientation Portrait & Landscape
Input : HDMI, DP, DVI-D, OPS, Analog
RGB, RS232C, RJ45, IR Receiver, USB
Output : DP, Audio, RS232C, RJ45
Power Supply 100-240V~, 50/60Hz
Power Type 220W, Smart Energy
Memiliki WEB OS
2 Bracket Video Wall Memiliki Kapabilitas untuk melakukan
Front Akses Maintenance, Sehingga
mampu mempermudah Servicing dan
Space Saver

88
3 Video Wall ControllerMemiliki Hot Swappable Modul Input
dan Output serta Power Supply
Memiliki Input dan Output Card HDMI
Support 4K DP/HDMI untuk Input dan
Output
Support VGA/HDMI/DVI Self Adaptation
Support untuk minimal 8 windows on
each two screen
Support sampai dengan 5 videowall
grouping untuk setiap controller dan
bisa dimodifikasi sampai lebih dari 5
Support Scene management untuk
fungsi setup sejumlah 255 scene
Memiliki Input Embended Audio
4 Manajemen Video Wall Memiliki Layar 10 inch dan IPS,
Controller Minimum Ram 4GB, Software IOS

Perangkat EMS yang ditawarkan harus memenuhi spesifikasi teknis berikut:

1) Data Center Monitoring Sytem:


 Built in Web server configuration
 An External GSM Modem can be connected to send alarms as text
messages (SMS) and Whatsapp/Telegram.
 Alerts can be sent to 5 e-mail addresses or as text messages to 5
phone numbers.
 Usable with more than 50 third-party software applications
(SNMP, SCADA and more).
 Up to 40 sensors
 12 Digital Input
 4 relay outputs (NO/NC)
 Datalogger for 250.000 records

2) Hummidity & Temperature sensor:


 Sensor measured range: -30°C/-10°C to +80°C (-22°F/14°F to
+176°F)
: 0 - 100% RH (Relative Humidity)
 Temp. sensor resolution: 0.1 °C
 Temp. measuring accuracy : ± 0.8 °C in range from +20°C to +40°C

89
: ± 1.3 °C (-10°C to +70°C)
 RH Accuracy : ± 5% RH, 20 - 80%RH non-condensing, 25 °C
 RH Linearity & Hysteresis : <3% RH typical, ±3% RH span maximum
 RH Repeatability : ±0.2% RH
 Communication : 1-Wire bus (Data, GND, +5V) - RJ11

3) Security Door Contact :


 Open door detector consists of a magnet and a contact (2 parts of
equal dimensions).
 Dimensions: 15 x 13 x 50 mm
 Mounting screws: Ø 3 mm
 Screw spacing: 40 mm
 Connection cable: 2-wire cable

4) Central Gateway SMS dan WA/TELEGRAM for sensors :


 Ethernet : 10 Mbit/s
 IP Protocol : ARP, TCP/IP (HTTP, netGSM)
 GSM : Quad-Band 850/900/1800/1900 MHz
 Antenna : External, SMA Quad-Band, 3 m

5) Data Collection :
 Data Collection Sofware is a free license application by the sensor
product
 Data input: LAN (http)/Email (POP3)/Portal
 Data output: Graph overview/MS Excel export /XML database/
Email report
 Application: Windows UI, Windows service (runs in the
background, suitable for servers too)
 License: Free of charge for 3 sensors/Commercial version for
8/20/250 sensors
 MS Excel export: Periodic, in the background, compatible with MS
Excel 2007 and newer

90
Volume Pekerjaan Infrastruktur pendukung Data Center

No Description Unit Qty

F Computer Facility
a Komputer R.NOC
- Instalasi Kabel Data 48 ttk
( 10 tk R.NOC - 14 ttk R. CC , 15 ttk r.paripurna, 5 ttk r.Sidang, 4 ttk
r.auditorium ))
Kabel UTP Cat 6, terproteksi oleh pipa conduit
b Pekerjaan Environmental Monitoring System (EMS)
- Data center environmental monitoring system 2 Unit
- Temperature & Humidity sensor untuk 19" rack cabinet 6 Unit
- Temperature sensor untuk 19" rack cabinet 8 Unit
- Temperature & Humidity sensor untuk ruangan DC 6 Unit
- Security Door contact ( untuk pintu masuk ) 1 Unit
- Water Leak Detection sensor 2 Unit
- Central Gateway GSM SMS dan WA/Telegram for sensors. 1 Unit
- Data capture, Excel reporting, monitoring Software 1 Unit
- Material Instalasi (kabel UTP, connector, trunking, dll) 1 Lot
- Pemasangan Monitoring System dan Material Instalasi 1 Lot
Test and Commisioning 1 Lot
c Pekerjaan Rack R.Network & R.Server
Pengadaan dan Pemasangan Rack 42 U
1 Rack 42 U, 19 " Depth 1000 mm, Perforated 5 set
( Warna Hitam )
Include :
- PDU 12 Outlet ( C13 ): 2 unit
- 4 fan
- Cagenut 80 pcs
- Caster & Jacking Kit
- Fixed Vented Shelf : 3 unit
2 Rack Wallmount 12 U 6 set
'Depth 600mm
12U
1x PDU
1 x patch pannel utp
(Warna Hitam )
Product Category : 19 inch Cabinet Rack
Product Series : Wallmount Rack Single Glass Door
Dimension (DxWxH) : 450 x 600 x 660 mm
Weight : ± 27kg

91
6.1.7.2 Infrastruktur Pendukung Command Center

Infrastruktur pendukung command center terdiri dari system video wall yang
akan di pasang di ruangan command center. Perangkat video wall yang
ditawarkan harus memenuhi spesifikasi berikut :

No Description Spesifikasi
1 Screen Size 55” class (55” diagonal)
Panel Technology IPS
Aspect Ratio 16:9
Native Resolution 1920 x 1080 (FHD)
Maksimum Bezel 0,4mm All Sides
Brightness 500cd/m
Contrast Ratio 1,400:1
Viewing Angle (H x V) 178 x 178
Video Wall 55" Color Depth 1.06 Billion
Response Time 8ms (G to G BW)
Running Time 24Hr
Orientation Portrait & Landscape
Input : HDMI, DP, DVI-D, OPS, Analog RGB, RS232C, RJ45, IR
Receiver, USB
Output : DP, Audio, RS232C, RJ45
Power Supply 100-240V~, 50/60Hz
Power Type 220W, Smart Energy
2 Bracket Video Memiliki Kapabilitas untuk melakukan Front Akses
Wall Maintenance, Sehingga mampu mempermudah Servicing dan
Space Saver

92
3 Video Wall Memilki Arstitektur Mesin NON OS (Sehingga Lebih Reliable
Controller dan Tidak Crash)
Memiliki Hot Swappable Modul Input dan Output serta Power
Supply
Memiliki Input dan Output Card HDMI
Support 4K DP/HDMI untuk Input dan Output
Support VGA/HDMI/DVI Self Adaptation
Support untuk minimal 8 windows on each two screen
Support sampai dengan 5 videowall grouping untuk setiap
controller dan bisa dimodifikasi sampai lebih dari 5
Support Scene management untuk fungsi setup sejumlah 255
scene
Memiliki Input Embended Audio

4 Manajemen Memiliki Layar 10 inch dan IPS, Ram 4GB, Software IOS
Video Wall
Controller

Volume Pekerjaan Infrastruktur pendukung Command Center

No Description Unit Qty

G Infrastruktur pendukung command center


a Pekerjaan Video Wall R.Command Center
55" -Videowall (55 Inch IPS Panel Display 500 nits, 24/7 Operation, with bezel
1 10 pcs
0,4mm
2 Front Mount Service Maintenance 10 pcs
Video Wall Processor HDMI 12 out HDMI, Include Video Wall Management
3 1 pcs
Software
IPAD WIFI 32 GB and Wireless Router Asus For Management Video Wall
4 1 pcs
System
5 10M HDMI cable – copper 16 pcs
6 Wireless Presentation 4 User Enterprise 1 set
7 Pemasangan, seting, programinng & Test Commisioning 1 set
8 Personal Computer (All-in One Full Set) maksimal 21” 12 set
- Prosessor intel i5
- DDR3 : 8GB
- Hardisk SSD 512 MB

93
6.2 Spesifikasi Teknis perangkat Infrastruktur jaringan
Untuk seluruh solusi teknologi perangkat server dan infrastruktur jaringan masing-
masing perangkat harus dapat mendukung dan memaksimalkan fitur dari setiap
perangkat yang ditawarkan (compatible).

A. Perangkat Infrastruktur jaringan Kantor Pusat

6.2.1 Core Switch


Perangkat Core Switch yang ditawarkan harus memenuhi spesifikasi sebagai
berikut:
1) Memiliki redundant power suply
2) Memiliki minimal 24 port 10 Gbps
3) Memiliki minimal 6 Port 40 Gbps
4) Memiliki kapasitas switching minimal 960 Gbps
5) Memiliki kapasitas Throughput/forwarding rate sampai dengan 714 Mbps
6) Mendukung layer 2 dan layer 3 switching
7) Perangkat memiliki fitur :
 ACL
 ARP
 Jumbo frame
 NetFlow/Sflow,
 VLAN
 Trunking (802.1q)
 DHCP,
 IPv4 dan IPv6
 Spanning Tree Protocol (STP)
 Simple Network Management Protocol (SNMP)
 SPAN (Switched Port Analyzer) dan Remote Switch Port Analyzer
(RSPAN)
 MCLAG/VPC/VLT/IRF
 Layer3 Routing Protocol minimal OSPF dan BGP

94
8) Termasuk menyediakan Kabel DAC 40 Gbps dengan panjang minimal
5 meter sebanyak 2 unit
9) Termasuk menyediakan SFP 40 Gbps SR sebanyak 2 unit
10) Termasuk menyediakan SFP+10G SR transceiver module sebanyak 24
unit
11) Termasuk garansi, support & service minimal selama 3 tahun
12) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired and
Wireless LAN Access Infrastructure, dengan melampirkan bukti data
peringkat Quadrant pada setiap perangkat/barang yang ditawarkan.

6.2.2 Access Switch non PoE


Perangkat Access Switch non PoE yang ditawarkan harus memenuhi
spesifikasi sebagai berikut:
1) Memiliki minimal 48 port 10/100/1000 Mbps autosensing port
2) Memiliki minimal 4x10G uplink
3) Dilengkapi minimal 2 unit modul transceiver SFP 10G
4) Memiliki forwarding rate minimal sebesar 130 Mbps
5) Memiliki switching capacity minimal sebesar 176 Gbps
6) Perangkat memiliki fitur :
 NetFlow/Sflow,
 VLAN
 SPAN (Switched Port Analyzer) dan Remote Switch Port
Analyzer (RSPAN)
 Link Aggregation Protocol
 L3 Routing minimal static route dan ospf
7) Termasuk garansi, support & service minimal selama 3 tahun
8) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired
and Wireless LAN Access Infrastructure, dengan melampirkan bukti

95
data peringkat Quadrant pada setiap perangkat/barang yang
ditawarkan.

6.2.3 Access Switch PoE


Perangkat Access Switch PoE yang ditawarkan harus memenuhi
spesifikasi sebagai berikut :
1) Memiliki minimal 48 port Poe+ 10/100/1000 Mbps autosensing port
2) Memiliki minimal 4x10G uplink
3) Dilengkapi minimal 2 unit modul transceiver SFP 10G
4) Memiliki forwarding rate minimal sebesar 130 Mpps
5) Memiliki switching capacity minimal sebesar 176 Gbps
6) Perangkat memiliki fitur :
 NetFlow/Sflow,
 VLAN
 SPAN (Switched Port Analyzer) dan Remote Switch Port
Analyzer (RSPAN)
 Link Aggregation Protocol
 L3 Routing minimal static route dan ospf
7) Termasuk garansi, support & service minimal selama 3 tahun
8) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired
and Wireless LAN Access Infrastructure, dengan melampirkan bukti
data peringkat Quadrant pada setiap perangkat/barang yang
ditawarkan.

6.2.4 Wireless Access point


Perangkat Wireless Access point yang ditawarkan harus memenuhi
spesifikasi sebagai berikut :
1) Mendukung minimal 3 frekeunsi radio: 2.4 Ghz, 5 Ghz dah 6 Ghz
2) Memiliki data rate minimal sebesar 1.2 Gbps pada frekuensi 5 Ghz
dan 2.4 Gbps pada frekuensi 6 Ghz
3) Support sampai 300+ user secara bersamaan

96
4) Memiliki fitur untuk mendeteksi AP lain yang bukan merupakan
bagian dari jaringan wireless yang telah dikonfigurasi
5) Memiliki teknologi multiple-input multiple-output (MIMO) dengan 2
spatial stream
6) Memiliki teknologi OFDMA
7) Untuk menjamin kompatibilitas dan memudahkan manajemen,
perangkat yang ditawarkan memiliki brand yang sama dengan
Wireless LAN Controller
8) Mendukung teknologi IEEE 802.11a/g/n/ac/ax
9) Memiliki minimal 1 x 100/1000/2500 BASE-T autosensing (RJ-45),
Power Over Ethernet (PoE)
10) Memiliki port management console micro usb
11) Mendukung standar security WPA3 dan Enhanced Open Security
12) Menyediakan tarikan kabel dari access switch PoE ke Access Point
jika di butuhkan.
13) Termasuk garansi, support & service minimal selama 3 tahun
14) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired
and Wireless LAN Access Infrastructure, dengan melampirkan bukti
data peringkat Quadrant pada setiap perangkat/barang yang
ditawarkan.

6.2.5 Wireless Controller


Perangkat Wireless Controller yang ditawarkan harus memenuhi
spesifikasi sebagai berikut:
1) Mendukung minimal 1000 client dan 40 Access Point
2) Memiliki interface minimal 4x 10/100/1000 base-T
3) Memiliki throughput firewall minimal 4 Gbps
4) Mendukung teknologi wifi 6
5) Mendukung teknologi WPA3
6) Memiliki fitur link aggregation

97
7) Memiliki Interface Userfriendly
8) Termasuk subscription license, garansi, support & service minimal
selama 3 tahun
9) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired
and Wireless LAN Access Infrastructure, dengan melampirkan bukti
data peringkat Quadrant pada setiap perangkat/barang yang
ditawarkan.

6.2.6 Server Farm Firewall


Perangkat Server Farm Firewall yang ditawarkan harus memenuhi
spesifikasi sebagai berikut :
1) Memiliki throughput NGFW ( identifikasi aplikasi / layer 7 firewall)
dengan throughput minimal 11 Gbps
2) Memiliki throughput Threat Prevention (Antivirus, IPS, Anti
spyware, file blocking, dan Analisis Ancaman Tidak Dikenal, fitur
logging, Identifikasi aplikasi dijalankan) minimal 5.5 Gbps
3) Memiliki arsitektur perangkat keras yang memisahkan Data Plane
dan Control / Management Plane secara fisik
4) Memiliki arsitektur Single Pass Parallel Processing yaitu arsitektur
yang melakukan proses inspeksi fitur security secara paralel /
bersamaan
5) Mampu menangani session minimal sebesar 1400K
6) Mampu menangani session baru per detik minimal sebesar 145K
7) Memiliki fitur firewall, IPS, Anti virus dan Analisis Ancaman Tidak
Dikenal, Anti spyware, dan DNS Security
8) Memiliki kemampuan untuk melakukan analisa di Bare Metal untuk
mendeteksi Unknown Threat berbasis sandbox (Bare Metal
Analysis).

98
9) Memiliki open API untuk integrasi dengan produk pihak ketiga
10) Memiliki port minimal 12 x RJ45, 10 x SFP+ , 4 x SFP28
11) Dilengkapi dengan 4 x transceiver SFP+ SR
12) Memiliki garansi, support & service minimal selama 3 tahun
13) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk Network Firewall,
dengan melampirkan bukti data peringkat Quadrant pada setiap
perangkat/barang yang ditawarkan.

6.2.7 Internet Firewall


Perangkat Internet Firewall yang ditawarkan harus memenuhi spesifikasi
sebagai berikut :
1) Memiliki throughput NGFW ( identifikasi aplikasi / layer 7 firewall)
dengan throughput minimal 4.2 Gbps
2) Memiliki throughput Threat Prevention (Antivirus, IPS, Anti spyware,
file blocking, dan Analisis Ancaman Tidak Dikenal, fitur logging,
Identifikasi aplikasi dijalankan) minimal 2.1 Gbps
3) Memiliki arsitektur perangkat keras yang memisahkan Data Plane
dan Control / Management Plane secara fisik
4) Memiliki arsitektur Single Pass Parallel Processing yaitu arsitektur
yang melakukan proses inspeksi fitur security secara paralel /
bersamaan
5) Mampu menangani session minimal sebesar 1000K
6) Mampu menangani session baru per detik minimal sebesar 48K
7) Memiliki fitur firewall, IPS, Anti virus dan Analisis Ancaman Tidak
Dikenal, Anti spyware, dan URL Filtering
8) Memiliki kemampuan untuk melakukan analisa di Bare Metal untuk
mendeteksi Unknown Threat berbasis sandbox (Bare Metal
Analysis).

99
9) Memiliki open API untuk integrasi dengan produk pihak ketiga
10) Memiliki port minimal 12 x RJ45, 4 x SFP, 4 x SFP+
11) Dilengkapi dengan 2 x transceiver SFP+ SR
12) Memiliki garansi, support & service minimal selama 3 tahun
13) Perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk Network Firewall,
dengan melampirkan bukti data peringkat Quadrant pada setiap
perangkat/barang yang ditawarkan.

6.2.8 Top Of Rack (TOR) Switch


Perangkat TOR switch yang ditawarkan harus memenuhi spesifikasi
sebagai berikut :
1) Merupakan Manageable Switch
2) Memiliki redundant power suply
3) Memiliki minimal 24 port 10 Gbps
4) Memiliki minimal 6 Port 40 Gbps
5) Memiliki kapasitas switching minimal 960 Gbps
6) Memiliki kapasitas Throughput / forwarding rate minimal 714 Mbps
7) Mendukung layer 2 dan layer 3 switching
8) Perangkat memiliki fitur :
 ACL
 ARP
 Jumbo frame
 NetFlow/Sflow,
 VLAN
 Trunking (802.1q)
 DHCP,
 IPv4 dan IPv6
 Spanning Tree Protocol (STP)

100
 Simple Network Management Protocol (SNMP)
 SPAN (Switched Port Analyzer) dan Remote Switch Port Analyzer
(RSPAN)
 MCLAG/VPC/VLT/IRF
 Layer3 Routing Protocol minimal OSPF dan BGP
9) Termasuk menyediakan Kabel DAC 40 Gbps dengan panjang minimal
5 meter sebanyak 2 unit
10) Termasuk menyediakan SFP 40 Gbps SR sebanyak 2 unit
11) Termasuk menyediakan SFP+10G SR transceiver module sebanyak 24
unit
12) Termasuk garansi, support & service minimal selama 3 tahun
13) Perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired and
Wireless LAN Access Infrastructure, dengan melampirkan bukti data
peringkat Quadrant pada setiap perangkat/barang yang ditawarkan.

6.2.9 Management Switch


Perangkat management switch yang ditawarkan harus memenuhi
spesifikasi sebagai berikut:
1) Merupakan manageable switch dengan ukuran maksimal 1RU
2) Memiliki minimal 48 port 10/100/1000 Mbps autosensing port
3) Memiliki 4x10G uplink
4) Dilengkapi 2 unit modul transceiver SFP 10G
5) Memiliki forwarding rate minimal sebesar 130 Mpps
6) Memiliki switching capacity minimal sebesar 176 Gbps
7) Perangkat memiliki fitur:
 NetFlow/Sflow,
 VLAN
 SPAN (Switched Port Analyzer) dan Remote Switch Port

101
Analyzer (RSPAN)
 Link Aggregation Protocol
 L3 Routing protocol minimal static route dan ospf
8) Memiliki redundant power supply unit
9) Termasuk garansi, support & service minimal selama 3 tahun
10) Perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Wired
and Wireless LAN Access Infrastructure, dengan melampirkan bukti
data peringkat Quadrant pada setiap perangkat/barang yang
ditawarkan.

6.2.10 SDWAN Router Kantor Pusat


Perangkat SDWAN router yang ditawarkan harus memenuhi spesifikasi
sebagai berikut :
1) Memiliki minimal 4 port Gigabit Ethernet
2) Memiliki minimal memory 4 GB
3) Mendukung LTE (dapat menggunakan external LTE modem)
4) Mendukung routing protocol static, OSPF dan BGP
5) Mendukung encapsulasi Generic Routing Encapsulation (GRE), IPSec,
Ethernet, 802.1q VLAN, PPP over Ethernet (PPPoE)
6) Mendukung algoritma kriptografi berikut :
 Encryption: AES-256 (in CBC mode)
 Authentication: SHA1-512 HMAC with zero touch provisioning
 Integrity: SHA1-512 HMAC
7) Memiliki fungsi traffic management
8) Mendukung minimum fitur secure end-to-end segmentation, stateful
firewall, web/URL filtering, dan secure application database update
9) Mendukung traffic flow analytic dan monitoring secara real-time dan
historical dengan on-premise SDWAN controller

102
10) Mendukung custom report yang dapat diunduh melalui GUI dalam
bentuk dokumen/pdf
11) Memiliki lisensi minimal 256 Mbps aggregate total
12) Dilengkapi SDWAN Controller (single management dashboard) yang
di install pada virtual machine
13) Termasuk subscription license, garansi, support dan service minimal
selama 3 tahun
14) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori WAN Edge
Infrastructure, dengan melampirkan bukti data peringkat Quadrant
pada setiap perangkat/barang yang ditawarkan.

6.2.11 SDWAN Router Rumah Aman

Perangkat SDWAN router rumah aman yang ditawarkan harus


memenuhi spesifikasi sebagai berikut:
1) Memiliki minimal 4 port Gigabit Ethernet
2) Memiliki minimal memory 4 GB
3) Mendukung LTE (dapat menggunakan external LTE modem)
4) Mendukung routing protocol static, OSPF dan BGP
5) Mendukung encapsulasi Generic Routing Encapsulation (GRE), IPSec,
Ethernet, 802.1q VLAN, PPP over Ethernet (PPPoE)
6) Mendukung algoritma kriptografi berikut :
 Encryption: AES-256 (in CBC mode)
 Authentication: SHA1-512 HMAC with zero touch provisioning
 Integrity: SHA1-512 HMAC
7) Memiliki fungsi traffic management
8) Mendukung minimum fitur secure end-to-end segmentation, stateful
firewall, web/URL filtering, dan secure application database update
9) Mendukung traffic flow analytic dan monitoring secara real-time dan
historical dengan on-premise SDWAN controller

103
10) Mendukung custom report yang dapat diunduh melalui GUI dalam
bentuk dokumen/pdf
11) Memiliki lisensi minimal 50 Mbps aggregate total
12) Dilengkapi SDWAN Controller (single management dashboard) yang
di install pada virtual machine
13) Termasuk subscription license, garansi, support dan service minimal
selama 3 tahun
14) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori WAN Edge
Infrastructure, dengan melampirkan bukti data peringkat Quadrant
pada setiap perangkat/barang yang ditawarkan.

6.2.12 Email Security


Perangkat Email Security yang ditawarkan adalah equal dengan email
security existing dengan memenuhi spesifikasi sebagai berikut:
1) Perangkat email security yang ditawarkan berupa Appliance dengan
form factor minimal 1 U
2) Memiliki prosesor minimal 1 x 2.1 GHz, 8 core
3) Memiliki memory minimal 16 GB DDR4
4) Memiliki kapasitas penyimpanan minimal 1 TB
5) Memiliki minimal 2 port NIC Rj45 10/100/1000 Mbps
6) Di lengkapi dengan lisensi untuk minimal 300 user
7) Memiliki redundant power supply
8) Memiliki fitur
 Anti Spam
 Anti virus
 Email encryption
 Data Loss Protection
 Anti Malware
9) Termasuk subscription license, garansi, support dan service minimal
selama 3 tahun

104
6.2.13 Load Balancer&WAF
Perangkat Load balancer & WAF yang ditawarkan harus memenuhi
spesifikasi sebagai berikut:
1) Merupakan appliance dengan form factor minimal 1U
2) Memiliki throughput L4/L7 minimal sebesar 20 Gbps
3) Memiliki kapasitas L7 request per second minimal sebesar 1000k
4) Memiliki kapasitas L4 connections per second minimal sebesar 450K
koneksi
5) Memiliki kapasitas L4 HTTP Request per second minimal sebesar
2000K
6) Memiliki minimal 8 port SFP 1 Gbps di lengkapi dengan 4
transceiver SFP SR
7) Memiliki minimal 2 port SFP 10 Gbps di lengkapi dengan 2
transceiver SFP+ SR
8) Memiliki minimal 1 processor 4-Core Intel Xeon processor
9) Memiliki minimal memory 32GB DDR4
10) Memiliki minimal storage 1 TB
11) Memiliki redundant power supply
12) Merupakan satu appliance dengan fungsi sebagai link load balancer
dan web application firewall
13) Memiliki Application Programming Interface (API) yang dapat di-
custom menggunakan tcl-based scripting language
14) Termasuk subscription license, garansi, support dan service minimal
selama 3 tahun
15) Perangkat yang ditawarkan minimal berada pada kuadrant
challengers gartner magic quadrant periode tahun 2020-2021 untuk
kategori Web Application Firewall, dengan melampirkan bukti data
peringkat Quadrant pada perangkat/barang yang ditawarkan.

105
6.2.14 Network & Application Performance Monitoring

A. Network Performance Monitoring


Network performance monitoring tools yang ditawarkan harus
memenuhi kriteria berikut:
1) Dapat di install pada server physical atau virtual
2) Dapat berjalan pada system operasi windows/unix
3) Mampu memonitor minimum 100 element/perangkat jaringan
4) Mampu memonitor perangkat dari berbagai macam brand (multi
brand)
5) Mampu memonitor perangkat wireless
6) Mampu melakukan discovery perangkat jaringan secara otomatis
7) Memiliki fitur mapping yang dapat menghasilkan mapping
topologi perangkat secara otomatis atau manual
8) Mampu memonitor performa dan kesehatan perangkat utama
perangkat termasuk temperature, fan speed dan power supply.
9) Mampu memberikan alert secara otomatis dan mengirimkan
notifikasi melalui email
10) Memiliki fungsi reporting yang dapat di kustomisasi dan di export
ke dalam format pdf atau format lainnya
11) Termasuk subscription license minimal selama 3 tahun

B. Application Performance Monitoring


1) Dapat di install pada server physical atau virtual
2) Dapat berjalan pada system operasi windows/unix
3) Mampu memonitor minimum 25 node/server baik berupa
physical atau virtual server
4) Mampu melakukan discovery server dan aplikasi secara otomatis
5) Mampu melakukan kalkulasi baseline tresshold untuk
performance alerting secara dinamis
6) Mampu memberikan alert secara otomatis dan mengirimkan
notifikasi melalui email
7) Memiliki fungsi reporting yang dapat di kustomisasi dan diexport
ke dalam format pdf atau format lainnya
8) Termasuk subscription license minimal selama 3 tahun

6.2.15 Bandwidth Management


Perangkat bandwidth Management yang ditawarkan harus memenuhi
spesifikasi sebagai berikut:
1) Mendukung hardware throughput minimal 8 Gbps

106
2) Memiliki lisensi bandwidth /throughput minimum 640 Mbps
3) Mendukung minimal 6.000.000 ip flows
4) Memiliki minimal 8 port 1GE Copper (RJ45) dengan kemampuan
bypass
5) Memiliki port management minimal 2 x 1GE Copper
6) Memiliki teknologi yang mampu menginspeksi setiap paket dan
melakukan klasifikasi traffic berdasarkan aplikasi, user, ip address,
lokasi dan berdasarkan elemen policy yang dibuat secara
statis/dinamis
7) Memiliki fitur Full Traffic Visibility dan Granular Traffic Control
8) Perangkat yang ditawarkan minimal berada pada kuadrant
challengers gartner magic quadrant periode tahun 2020-2021 untuk
kategori Broadband Traffic Management, dengan melampirkan
bukti data peringkat Quadrant pada perangkat/barang yang
ditawarkan.

6.2.16 Sistem Operasi


Microsoft Windows Server standard Edition LTSC versi terbaru dengan
lisensi minimal untuk 56 core
6.2.17 Software management Virtualisasi
Software Management Virtualisasi yang ditwarkan adalah VmWare versi
terbaru, termasuk subscription license minimal selama 3 tahun

6.2.18 Server Virtualisasi


Server Virtualisasi yang ditawarkan harus memenuhi spesifikasi minimal
sebagai berikut:
1) Memiliki prosesor 2 x intel® Xeon® Gold 6330 2G, 28C/56T,
11.2GT/s, 42M Cache, Turbo, DDR4-2933
2) Memiliki memory 16 x 32GB

107
3) Memiliki HDD 6 x 960GB SSD SATA Mix Use 6Gbps 512 2.5in Hot-
plug
4) Memiliki Dual-Port LOM 1Gb
5) Memiliki Dual Port 10G SFP+
6) Memiliki Dual Port 16Gb Fibre Channel HBA
7) Memiliki redundant power supply
8) Memiliki warranty dan support selama 3 tahun (24x7) 4-hour Onsite
Service
9) Termasuk menyediakan lisensi virtualisasi VMware vSphere 7
Enterprise Plus untuk 3 tahun
10) Termasuk menyediakan lisensi Network virtualisasi VMware NSX-T
Data Center Enterprise Plus untuk 3 tahun

11) Termasuk menyediakan lisensi Cloud Infrastructure VMware Tanzu-


basic untuk 3 tahun

6.2.19 SAN Switch


SAN Switch yang ditawarkan harus memenuhi spesifikasi sebagai
berikut:
1) Memiliki form factor maksimal 1U
2) Memiliki minimal 24 port 16G BFibre Channel dengan 24 port aktif
dilengkapi dengan 24 SFP FC 16GB Transceiver module
3) Memiliki warranty selama 3 tahun
4) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Primary
Storage, dengan melampirkan bukti data peringkat Quadrant pada
setiap perangkat/barang yang ditawarkan.

108
6.2.20 SAN Storage and expansion Enclosure
SAN Storage and expansion enclosure yang ditawarkan harus memenuhi
spesifikasi sebagai berikut:
1) Memiliki dual controller minimal 16Gb Fibre Channel 8 port
2) Dilengkapi minimal 8 unit SFP FC 16 GB
3) Memiliki memory minimal 32 Gb (total memory)
4) Memiliki 24 x 1.92TB read SSD dan 96 x 2.4TB 10K RPM SAS 12Gbps
512e 2.5in Hot-plug Hard Drive (4 x expansion enclosure)
5) Memiliki kemampuan ekpansi kapasitas hingga 2 PB
6) Memiliki dedicated management port tiap controller
7) Memiliki fitur auto tiering
8) Memiliki kemampuan untuk konfigurasi RAID 1, 5, 6, 10
9) Memiliki fitur thin provisioning
10) Memiliki fitur snapshot hingga 1024 maximum snapshots per array
11) Memiliki fitur replikasi antar storage
12) Server, SAN Switch, dan SAN Storage berasal dari Principal yang
sama untuk menjamin ketersediaan support, dan memudahkan
dalam hal klaim garansi serta pelaporan masalah.
13) Memiliki warranty support selama 3 tahun.
14) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori Primary
Storage, dengan melampirkan bukti data peringkat Quadrant pada
setiap perangkat/barang yang ditawarkan.

6.2.21 Cabling System


Cabling System yang ditawarkan harus memenuhi spesifikasi sebagai
berikut :
1) Menyediakan tarikan kabel UTP category 6 sebanyak 48 node/titik
dengan spesifikasi:

109
Cabiling Materials Qty Satuan

Paired - UTP Category 6 belden USA/Commscope/Schineider


lot
setara 1

KeyConnect Shielded Patch Panel, 24-port, 1U, Black (Empty) 2 Unit


Modular Connectors - CAT6+ Modular Jack – KeyConnect 96 Pcs
Horizontal Cable Manager, 1U Panel, 19" 2 Unit
24AWG Category 6 UTP Patch Cord, LSZH, Blue, 2 Meter 48 Pcs
24AWG Category 6 UTP Patch Cord, LSZH, Blue, 3 Meter 48 Pcs
86×86 Key Connect – Double Port - Faceplate 48 Pcs

2) Menyediakan tarikan Fiber Optik dengan spesifikasi berikut :


Cabiling Materials Qty Satuan
24 Core OM4 50um/125um, Outdoor Direct Buried Armored
Double Jacket 550 meter
8 Core OM4 Multimode Universal Duct Cable, Single Jacket
50/125um 120 meter
FiberExpress - Patch Panels in rack and wall mount with Splice Tray
and Adapter Strips, 1U 2 slots Rack mount Patch panel, Including 1 unit
8
x 24F splice tray
FiberExpress - Patch Panels in rack and wall mount with Splice Tray
and Adapter Strips, 2U 4 slots Rack mount Patch panel, Including 2 ea
2
x 24F splice trays

24F/ 12 Port LC Duplex adapter strip, Ceramic sleeve for OM4 24 Unit

Blank adapter strip 2 Unit


FiberExpress Simplex Pigtail, LC-Open Simplex, MM, OM4, Erika
Violet 576 Unit
Patch Cord FO LC-SC Duplex, 3 Meter, OM4. 248 ea

110
Buffer Tubing Kit (1 roll = 50 mtr) 2 Roll
Splice Protector 2 Pack

3) Menyediakan kelengkapan/aksesories pendukung seperti high


impact conduit, klem, sock dan lain-lain sesuai standar best practice
yang berlaku

6.2.22 Lisensi Pendukung aplikasi

Spesifikasi lisensi dan subskripsi pendukung aplikasi mobile perlindungan


saksi dan korban adalah Sebagai berikut :

Deskripsi Volume Satuan


Mobile Software
Playstore Account Developer 1 Years
Applestore Account Developer 1 Years
Maps SDK Android (100000 calls) 36 Month
Maps SDK IOS (100000 calls) 36 Month
Google Find Place (25000 calls) 36 Month
Dashboard Report License
Creator License 1 unit
Viewer License 10 unit

B. Perangkat Infrastruktur jaringan perwakilan daerah


6.2.23 SDWAN Router perwakilan daerah
Perangkat SDWAN router perwakilan daerah yang ditawarkan harus
memenuhi spesifikasi sebagai berikut :
1) Memiliki minimal 4 port Gigabit Ethernet
2) Memiliki minimal memory 4 GB
3) Mendukung LTE (dapat menggunakan external LTE modem)
4) Mendukung routing protocol static, OSPF dan BGP
5) Mendukung encapsulasi Generic Routing Encapsulation (GRE), IPSec,
Ethernet, 802.1q VLAN, PPP over Ethernet (PPPoE)

111
6) Mendukung algoritma kriptografi berikut :
 Encryption: AES-256 (in CBC mode)
 Authentication: SHA1-512 HMAC with zero touch provisioning
 Integrity: SHA1-512 HMAC
7) Memiliki fungsi traffic management
8) Mendukung minimum fitur secure end-to-end segmentation, stateful
firewall, web/URL filtering, dan secure application database update
9) Mendukung traffic flow analytic dan monitoring secara real-time dan
historical dengan on-premise SDWAN controller
10) Mendukung custom report yang dapat diunduh melalui GUI dalam
bentuk dokumen/pdf
11) Memiliki lisensi minimal 50 Mbps aggregate total
12) Dilengkapi SDWAN Controller (single management dashboard) yang
di install pada virtual machine
13) Termasuk subscription license, garansi, support dan service minimal
selama 3 tahun
14) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori WAN Edge
Infrastructure, dengan melampirkan bukti data peringkat Quadrant
pada setiap perangkat/barang yang ditawarkan.

6.2.24 Access Switch perwakilan daerah


Perangkat Switch perwakilan daerah yang ditawarkan harus memenuhi
spesifikasi sebagai berikut :
1) Memiliki minimal 8 port gigabit Ethernet dan 2 port SFP
2) Memiliki forwarding rate minimal 18 Mpps
3) Memiliki forwarding bandwidth minimal 24Gbps
4) Bisa di manage melalui CLI dan web UI
5) Mendukung minimal 4094 VLAN ID

112
6.2.25 SDWAN Router Mobile Witness Room
Perangkat SDWAN router mobile witness room yang ditawarkan harus
memenuhi spesifikasi sebagai berikut :
1) Memiliki minimal 4 port Gigabit Ethernet
2) Memiliki minimal memory 4 GB
3) Mendukung LTE (dapat menggunakan external LTE modem)
4) Mendukung routing protocol static, OSPF dan BGP
5) Mendukung encapsulasi Generic Routing Encapsulation (GRE), IPSec,
Ethernet, 802.1q VLAN, PPP over Ethernet (PPPoE)
6) Mendukung algoritma kriptografi berikut :
 Encryption: AES-256 (in CBC mode)
 Authentication: SHA1-512 HMAC with zero touch provisioning
 Integrity: SHA1-512 HMAC
7) Memiliki fungsi traffic management
8) Mendukung minimum fitur secure end-to-end segmentation, stateful
firewall, web/URL filtering, dan secure application database update
9) Mendukung traffic flow analytic dan monitoring secara real-time dan
historical dengan on-premise SDWAN controller
10) Mendukung custom report yang dapat diunduh melalui GUI dalam
bentuk dokumen/pdf
11) Memiliki lisensi minimal 50 Mbps aggregate total
12) Dilengkapi SDWAN Controller (single management dashboard) yang
di install pada virtual machine
13) Termasuk subscription license, garansi, support dan service minimal
selama 3 tahun
14) perangkat yang ditawarkan berada pada kuadran leader Gartner
magic quadrant periode tahun 2020-2021 untuk kategori WAN Edge
Infrastructure, dengan melampirkan bukti data peringkat Quadrant
pada setiap perangkat/barang yang ditawarkan.

113
6.3 Spesifikasi Teknis Ruang Sidang Mahkamah Pimpinan (Paripurna)

Ruang sidang mahkamah pimpinan bertempat di Lt.4 gedung LSPK dengan acuan
design sebagai berikut ini :

Gambar Design/layout Ruangan Rapat Paripurna Lt.4

Gambar Design interior Ruangan Rapat Paripurna Lt.4

Penyedia wajib menyerahkan gambar kerja sesuai standar yang berlaku untuk
setiap bagaian pekerjaan yang dilakukan dalam pembangunan ruang sidang
mahkamah pimpinan.

A. Pekerjaan Sipil
Pekerjaan sipil yang terdapat pada pembangunan ruangan rapat paripurna
meliputi :
a) Pembongkaran ruangan existing

114
Kegiatan pembongkaran ruangan existing harus memperhatikan aspek
keamanan, kebersihan dan kenyamanan pengguna di sekitar area
ruangan existing dan harus di koordinasikan dengan pihak pengelola
gedung.

b) Pemasangan dinding / partisi


Spesifikasi Teknis :
Partisi Gipsum :
 Rangka : Rangka vertikal Metal Stud tebal 0,4mm.
Rangka horizontal atas dan bawah U Runner tebal 0,4mm.
 Penutup partisi : Digunakan Gypsum Board yang bermutu baik tebal =
9 mm.
 Bahan penutup sambungan partisi : Compound, paper tape yang
berpori/berlubang dan bergaris tengah.

c) Pemasangan Plafon / Ceiling


Spesifikasi Teknis
Rangka :
 Rangka dari besi hollow galvanis 4 x 4 cm/ 2 x 4 cm, tebal pelat besi
hollow minimal 0,35 mm.
Penutup langit-langit :
 Gypsum Board yang bermutu baik produk Jayaboard/knauf
atau produk lain yang setara, tebal = 9mm.
Bahan penutup sambungan plafond :
 Compound atau bahan plester ex UB400 atau produk lain yg
setara. Dan paper tape yang berpori/berlubang dan bergaris
tengah.

d) Pekerjaan Struktur & Furnishing Serta Furniture R. Rapat Paripurna


pekerjaan ini meliputi pengadaan pekerjaan Struktur & Backdrop
Videowall dan bahan-bahan kelengkapannya serta, peralatan serta
alat-alat bantu yang dibutuhkan.
Spesifikasi Teknis
Struktur
 Rangka:
Besi Holow 40x40mm tebal 1,8mm Finishing Spraypaint ex.
Danaglos/Danapaint/setara
 Base Plate; 3mm

115
 Dinabolt & aksesoris
Backdrop
 Panel Backdrop: bahan Plywood dan MDF dengan lapisan HPL
0,8 mm
 Base Panel Videowall, dengan Bahan Plywood tebal 18mm,
Finishing Cat

Furniture
 Bahan Plywood tebal 18mm, Finishing dengan lapisan HPL.
 Besi Holow 40x40; tebal 1,8mm

B. Perangkat video Wall


Perangkat video wall yang ditawarkan harus memenuhi spesifikasi
berikut :
No Description Spesifikasi
1 Screen Size 55” class Panel Technology IPS Aspect Ratio
16:9
Native Resolution 1920 x 1080 (FHD)
Maksimum Bezel 0,4mm All Sides
Brightness 500cd/m
Contrast Ratio 1,400:1
Viewing Angle (H x V) 178 x 178
Color Depth 1.06 Billion
Video Wall 55"
Response Time 8ms (G to G BW)
Running Time 24Hr
Orientation Portrait & Landscape
Input : HDMI, DP, DVI-D, OPS, Analog RGB, RS232C,
RJ45, IR Receiver, USB
Output : DP, Audio, RS232C, RJ45
Power Supply 100-240V~, 50/60Hz
Power Type 220W, Smart Energy Saving
2 Bracket Video Wall Memiliki Kapabilitas untuk melakukan Front Akses
Maintenance, Sehingga mampu mempermudah
Servicing dan Space Saver

116
3 Video Wall Memilki Arstitektur Mesin NON OS (Sehingga Lebih
Controller Reliable dan Tidak Crash) Memiliki Hot Swappable
Modul Input dan Output serta Power Supply
Memiliki Input dan Output Card HDMI
Support 4K DP/HDMI untuk Input dan Output Support
VGA/HDMI/DVI Self Adaptation Support untuk minimal 8
windows on each two screen
Support sampai dengan 5 videowall grouping untuk
setiap controller dan bisa dimodifikasi sampai lebih dari
5
Support Scene management untuk fungsi setup
sejumlah 255 scene
Memiliki Input Embended Audio
4 Manajemen Video Memiliki Layar 10 inch dan IPS, Ram 4GB, Software IOS
Wall Controller

Volume pekerjaan Sipil Ruang Rapat Paripurna (Mahkamah Pimpinan)

No Description Qty Unit

A PEKERJAAN PRA POJECT


PEKERJAAN PERSIAPAN

1 Mobilisasi Alat dan Bahan Ls


1,00
2 Survey, Ploting dan Marking Area Ls
1,00
3 Kebersihan dan Keamanan Kerja Ls
1,00
4 Proteksi dan Alat Bantu Kerjaa Ls
1,00
5 Desain dan Shopdrawing Ls
1,00

B PEKERJAAN BONGKARAN

1 Pek. Bongkaran Partisi Gypsum Ls


1,00
2 Pek. Bongkaran Plafond Existing Ls
1,00
3 Pek. Bongkaram Jendela/Partisi kaca Ls
1,00

117
4 Pek. Bongkaran Instalasi Listrik Ls
1,00
5 Pek. Bongkaran Furniture Ls
1,00
6 Pek. Bongkaran Kusen/pintu Ls
1,00
7 Pek. Pembersigan/buang puing Ls
1,00
8 Pekerjaan Pembuangan Sampah bongkaran Ls
1,00

B PEKERJAAN STRUKTUR & BACKDROP

1 Pekerjaan Struktur Wall display 3 x 2, 55", Uk. 3660 x 3800 Unit


1,00
Spek:
- Besi Hollow 40x40mm Fin. Spraypaint ex.
Danaglos/Danapaint/setara

- 3mm thk. Base Plate, Dynabolt dan Material pendukung

2 Pekerjaan Backdrop Walldisplay uk 8761 x 3030 m2


21,50
Spek:
- Plywood 18,15,12,9mm Fin. HPL ex. TACO

3 Base Tv uk 3660 x 1380 m2


5,05
Spek:
- Plywood 18mm
- Black Painted Doff
4 Pek. List Stainless t: 5 Cm Ls
1,00

C PEKERJAAN PLAFON

1 Pek. Plafond Gypsum Flat m2


119,70
Spek:
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm

2 Pek. Pengecatan Plafond Gypsum m2


141,70
Spek:
- Cat Interior ex. Vynilex
3 Pek.Drop Ceiling m2

118
22,00
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm

4 Pek.List Drop Ceilling m2


18,00
- Plywood 12mm, Fin HPL ex Taco

5 Pek. Cornice t.5 cm m1


56,90

D PEKERJAAN DINDING
1 Pek. Partisi Gypsum 2 Muka 77,80 m2
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm

2 Pek. Pengecatan Plafond Gypsum m2


122,05
Spek:
- Cat Interior ex. Vynilex
3 Pek. Peredam Dinding m2
96,37
Spek:
- Rockwool Den. 60

4 Pekerjaan Wallpanel Kayu Dinding uk.800 x 3000 unit


8,00
Spek:
- Plywood 18,15,12,9mm Fin. HPL ex. TACO

5 Pek. Wallpaper Dinding m2


86,90

E PEKERJAAN LANTAI

1 Pek. Peninggian Lantai (Stage Area Sidang) 29,80 m2


Spek:
- Besi Siku 40x40 thk. 3mm Fin. Spraypaint
- Plywood 18 mm Fin. Karpet
- Accessories

2 Pek. Pelapis Lantai Karpet 29,80 m2

3 Pek.Plint Lantai 10 cm 47,90 m2


- Plywood 12 mm fin HPL ex TACO

119
F PEKERJAAN FURNISHING

1 Pek. Backdrop Area Stage Uk. 8761 x 3030 26,55 m2


Spek:
- Plywood 18,15,12,9mm Fin. HPL ex. TACO

2 Pek. Kong Liong Pintu Area Entrance 7,24 m2


Spek:
- Plywood 9 mm Fin. HPL Ex. TACO/Setara

3 Pek. Pintu Kamuflase Area Stage Uk. 800 x 2400 1,00 Unit
- Plywood 18 mm Fin. HPL Ex. TACO/Setara

4 Pek.Pintu Utama Uk 900 x 2400 2,00 unit


- Plywood 18 mm Fin. HPL Ex. TACO/Setara

E PEKERJAAN FURNITURE

1 Pek. Meja Paripurna Uk. 6600 x800 set


1,00
Spek:
- Body Meja, Plywood 12 mm, MDF 6mm Fin. Duc
- Hollow 40 x 40 thk. 18mm
- Box Lampu Linier Cover Acrillyc
- Top Table 18mm Fin HPL ex. TACO
- Kisi - Kisi

2 Pek. Meja Sidang U shape Uk. 10400 x 650 Unit


1,00
Spek:
- Body Meja, Plywood 12 mm, MDF 6mm Fin. Duc
- Hollow 20 x 20 thk. 18mm
- Top Table 18mm Fin HPL ex. TACO

3 Pek. Meja Kecil Uk. 1200 x 600 Unit


2,00
Spek:
- Body Meja, Plywood 12 mm, MDF 6mm Fin. Duc
- Hollow 20 x 20 thk. 18mm
- Top Table 18mm Fin HPL ex. TACO

4 Pek. Pengadaan Kursi Pemimpin Rapat Unit


7,00
Spek:
- Senator I GAR Synch T35 CB/Setara

120
5 Pek. Pengadaan Kursi Peserta Sidang Unit
16,00
Spek:
- Senator II GAR Synch T35 SCB/Setara

6 Pek.Sofa 3 Seater Area Istirahat Pimpinan unit


1,00
Spek:
- Informa/IKEA/Setara

7 Pengadaan Meja Area Istirahat Pimpinan Uk 600 x 1000 unit


1,00
Spek:
- Mody Meja, Plywood 18 mm, MDF 3 mm Fin HPL
- Kaca Clear 5mm

8 Pek. Logo LPSK 1,00 Un


Spek:
- Neon box Dia. 40 Cm

9 Lettering LPSK t: 30 Cm 1,00 Lot


Spek:
- Stainless stell emboss + bending

10 Lettering LEMBAGA PERLINDUNGAN SAKSI DAN KORBAN t: 12 Cm 1,00 lot


Spek:
- Stainless stell emboss + bending

F PEKERJAAN MEP

1 Pek. Inst. Penerangan titik


30,00
Spek:
-Kabel NYM 3x2.5 ex. Supreme/Setara

2 Pek. Lampu Downlight unit


20,00
Spek:
- -slim Diameter 15 Cm, ex. Phillips/Setara
3 Pek. Lampu LED Spot unit
2,00
4 Pek. Lampu LED Linier incl balast m'
135,24
5 Pek. Exhaust Fan 10 inchi unit
1,00
6 Pek, Pemasangan AC Split 2 PK Plus Instalasinya buah

121
4,00

7 Material Bantu lot


1,00

8 Passive Mounting Speaker 8" 4,00 unit


Spek: Tannoy DVS8T/Setara

9 Power Amplifier 240 Watt 70V w/ DSP 1,00 unit


Spek : Lab Gruppen Lucia 240/1-70 /Setara

10 Dual Handheld Wireless Mic 3,00 unit


Spek: Shure BLX288/PG58 /Setara

11 10 Channel Analog Mixer 1,00 unit


Spek: Yamaha MG 10XU /Setara

12 Material Instalasi Audio 1,00 lot

Volume pekerjaan Video Wall Ruang Rapat Paripurna (Mahkamah


Pimpinan)

No Description Unit Qty

G Computer Facility
a Pekerjaan Video Wall R.Command Center

1 55" -Videowall ( 55 Inch IPS Panel Display 500 nits, 24/7 Operation 6 pcs

2 Front Mount Service Maintenance 6 pcs

3 Video Wall Procesor 4 Out, Incllude Video Wall Management Software 1 pcs

IPAD WIFI 32 GB and Wireless Router Asus For Management Video Wall
4 1 pcs
System

5 10M HDMI cable - copper 4 pcs

6 Splitter HDMI 1 In 8 Out 1 pcs

7 Retractable Lift Monitor 15.6 inch 7 pcs

122
8 Pemasangan, seting, programinng & Test Commisioning 1 set

6.4 Spesifikasi Teknis Ruang Sidang Saksi


Ruang sidang saksi bertempat di Lantai 1 gedung LSPK dengan acuan design
sebagai berikut ini :

Gambar Design Ruangan Sidang Lt.1

123
Gambar Design Interior Ruangan Sidang Lt.1

Penyedia wajib menyerahkan gambar kerja sesuai standar yang berlaku untuk
setiap bagian pekerjaan yang dilakukan dalam pembangunan Ruangan Sidang.

A. Pekerjaan Sipil
Pekerjaan sipil yang terdapat pada pembangunan ruangan sidang meliputi :
a) Pembongkaran ruangan existing
Kegiatan pembongkaran ruangan existing harus memperhatikan aspek
keamanan, kebersihan dan kenyamanan pengguna di sekitar area
ruangan existing dan harus di koordinasikan dengan pihak pengelola
gedung.
b) Pemasangan dinding / partisi
Spesifikasi Teknis :
 Rangka : Rangka vertikal Metal Stud tebal 0,4mm.
Rangka horizontal atas dan bawah U Runner tebal 0,4mm.
 Penutup partisi : Digunakan Gypsum Board yang bermutu baik tebal =
9 mm.
 Bahan penutup sambungan partisi : Compound, paper tape yang
berpori/berlubang dan bergaris tengah.
c) Pemasangan Plafon / Ceiling
Spesifikasi Teknis :
Rangka :

124
 Rangka dari besi hollow galvanis 4 x 4 cm/ 2 x 4 cm, tebal pelat besi
hollow minimal 0,35 mm.
Penutup langit-langit :
 Gypsum Board yang bermutu baik produk Jayaboard/knauf
atau produk lain yang setara, tebal = 9mm.
Bahan penutup sambungan plafond :
 Compound atau bahan plester ex UB400 atau produk lain yg
setara. Dan paper tape yang berpori/berlubang dan bergaris
tengah.
d) Pekerjaan Struktur & Furnishing Serta Furniture Ruangan Sidang
pekerjaan ini meliputi pengadaan pekerjaan Struktur & Backdrop
Videowall dan bahan-bahan kelengkapannya serta, peralatan serta alat-
alat bantu yang dibutuhkan.
Spesifikasi Teknis
Struktur
 Rangka:
Besi Holow 40x40mm tebal 1,8mm Fin. Spraypaint ex.
Danaglos/Danapaint/setara
 Base Plate; 3mm
 Dinabolt & aksesoris
Backdrop
 Panel Backdrop: bahan Plywood dan MDF dengan lapisan HPL
0,8 mm
 Base Panel Videowall, dengan Bahan Plywood tebal 18mm, Fin.
Cat
Furniture
 Bahan Plywood tebal 18mm, Finishing dengan lapisan HPL.
 Besi Holow 40x40; tebal 1,8mm

Volume pekerjaan sipil pembangunan ruang sidang saksi

No Description Qty Unit

A PEKERJAAN PRA POJECT


PEKERJAAN PERSIAPAN
1 Mobilisasi Alat dan Bahan 1,00 Ls
2 Survey, Ploting dan Marking Area 1,00 Ls

125
3 Kebersihan dan Keamanan Kerja 1,00 Ls
4 Proteksi dan Alat Bantu Kerjaa 1,00 Ls
5 Desain dan Shopdrawing 1,00 Ls

B PEKERJAAN BONGKARAN
1 Pek. Bongkaran Plafond Existing 1,00 Ls
2 Pek. Bongkaran Instalasi Listrik 1,00 Ls
3 Pek. Bongkaran Backdrop TV Existing 1,00 Ls
4 Pek. Bongkaran Furniutr Existing 1,00 Ls
5 Pek. Pembersihan/buang puing 1,00 Ls
6 Pek. Bongkar Lantai Vynil Existing 1,00 Ls

C PEKERJAAN STRUKTUR & BACKDROP


Pekerjaan Struktur Wall display 3 x 2, 55", Uk. 3660 x
1 1,00 Unit
3000
Spek:
- Besi Hollow 40x40mm Fin. Spraypaint ex.
Danaglos/Danapaint/setara
- 3mm thk. Base Plate, Dynabolt dan Material
pendukung
2 Pekerjaan Backdrop Wall display uk 3619 x 3795 8,70 m2
Spek:
- Plywood 18,15,12,9mm Fin. HPL ex. TACO
3 Base Tv uk 3660 x 1375 5,03 m2
Spek :
- Plywood 18mm
- Black Painted Doff
4 Pek. List Stainless t: 5 Cm 1,00 Ls

D PEKERJAAN PLAFON
1 Pek. Plafond Gypsum Flat 30,30 m2
Spek:
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
2 Pekerjaan Plafond Gypsum (UP Ceiling ) 9,72 m2
Spek:
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm

126
3 Pek. Pengecatan Plafond Gypsum 40,02 m2
Spek:
- Cat Interior ex. Vynilex/Setara

E PEKERJAAN DINDING
1 Pek. Partisi Gypsum 2 Muka 20,46 m2
- Gypsumboard 9mm, Ex. Jayaboard/Knauf/Setara
- Rangka Hollow Galvanis 4x4, 4x2, 0.35 mm
2 Pek. Peredam Dinding 20,46 m2
Spek:
- Rockwool Den,60
3 Pek. Pengecatan Dinding 2 sisi 97,30 m2
Spek:
- Cat Interior ex. Vynilex
4 Pekerjaan Skirting Kayu (Plint Lantai) t.100 mm 20,89 m2
Spek:
- Plywood 12 mm Fin. HPL ex. TACO

F PEKERJAAN LANTAI
1 Pek. Peninggian Struktur Lantai 10,60 m2
Spek:
- Plywood 18 mm Fin. Karpet
- Accessories
2 Pek. Lantai Karpet/Carpet tile uk.50x50 10,60 m2

G PEKERJAAN PINTU
1 Pek. Pintu Single Uk 900 x 2400 1,00 Unit
Spek:
- Plywood 18mm Fin. HPL ex. TACO
H PEKERJAAN FURNITURE & FURNISHING
1 Pek. Meja Sidang uk.31000 x 800 mm 1,00 set
Spek:
- Body Meja, Plywood 18 mm Double Fin HPL ex TACO
- Hollow 40 x 40 thk. 18mm fin spraypaint
- Accecories
2 Pek. Meja Peserta Uk 2500 x 600 2,00 Unit
Spek:
- Body Meja, Plywood 18 mm Double Fin HPL ex TACO

127
- Hollow 40 x 40 thk. 18mm fin spraypaint
- Accecories
3 Pek. Meja Saksi Uk 1500 x 600 1,00 Un
Spek:
- Body Meja, Plywood 18 mm Double Fin HPL ex TACO
- Hollow 40 x 40 thk. 18mm fin spraypaint
- Accecories
4 Pek. Pengadaan Kursi Pimpinan Sidang 3,00 Unit
Spek:
- Senator I GAR Synch T35 CB
5 Pek. Pengadaan Kursi Jaksa & Saksi 5,00 Unit
Spek:
- Senator II GAR Synch T35 SCB
6 Pek. Logo LPSK 1,00 Un
Spek:
- Neon box Dia. 40 Cm

I PEKERJAAN MEP + AUDIO


1 Pek. Inst. Penerangan 16,00 titik
Spek:
-Kabel NYM 3x2.5 ex. Supreme/Setara
2 Pek. Lampu Downlight 15,00 unit
Spek:
- -slim Diameter 15 Cm, ex. Phillips/Setara
3 Pek. Lampu LED Linier incl balast 10,00 m'
4 Material Bantu 1,00 lot
5 Passive Mounting Speaker 8" 4,00 unit
Spek: Tannoy DVS8T/Setara
6 Power Amplifier 240 Watt 70V w/ DSP 1,00 unit
Spek : Lab Gruppen Lucia 240/1-70 /Setara
7 Dual Handheld Wireless Mic 2,00 unit
Spek: Shure BLX288/PG58 /Setara
8 10 Channel Analog Mixer 1,00 unit
Spek: Yamaha MG 10XU /Setara
9 Material Instalasi Audio 1,00 lot

128
B. Spesifikasi Video Wall

Perangkat video Wall yang ditawarkan harus memenuhi spesifikasi berikut :

No Description Spesifikasi
1 Screen Size 55” class
Panel Technology IPS
Aspect Ratio 16:9
Native Resolution 1920 x 1080 (FHD)
Maksimum Bezel 0,4mm All Sides
Brightness 500cd/m
Contrast Ratio 1,400:1
Viewing Angle (H x V) 178 x 178
Video Wall 55" Color Depth 1.06 Billion
Response Time 8ms (G to G BW)
Running Time 24Hr
Orientation Portrait & Landscape
Input : HDMI, DP, DVI-D, OPS, Analog RGB,
RS232C, RJ45, IR Receiver, USB
Output : DP, Audio, RS232C, RJ45
Power Supply 100-240V~, 50/60Hz
Power Type 220W, Smart Energy Saving
2 Bracket Video Wall Memiliki Kapabilitas untuk melakukan Front
Akses Maintenance, Sehingga mampu
mempermudah Servicing dan Space Saver
3 Video Wall Memilki Arstitektur Mesin NON OS (Sehingga
Controller Lebih Reliable dan Tidak Crash)
Memiliki Hot Swappable Modul Input dan
Output serta Power Supply
Memiliki Input dan Output Card HDMI
Support 4K DP/HDMI untuk Input dan Output
Support VGA/HDMI/DVI Self Adaptation
Support untuk minimal 8 windows on each two
screen
Support sampai dengan 5 videowall grouping
untuk setiap controller dan bisa dimodifikasi

129
sampai lebih dari 5
Support Scene management untuk fungsi setup
sejumlah 255 scene
Memiliki Input Embended Audio

4 Manajemen Video Memiliki Layar 10 inch dan IPS, RAM 4GB,


Wall Controller Software IOS

Volume pekerjaan videowall ruang sidang saksi

No Description Unit Qty

G Videowall Ruang Sidang

1 55" -Videowall IPS Panel Display 500 nits, 24/7 Operation. 6 pcs

2 Front Mount Service Maintenance 6 pcs

Video Wall Procesor in 4 Out, Include Video Wall Management


3 1 pcs
Software
IPAD WIFI 32 GB and Wireless Router Asus For Management
4 1 pcs
Video Wall System

5 10M HDMI cable - copper 4 pcs

6 Pemasangan, seting, programinng & Test Commisioning 1 set

130
6.5 Spesifikasi Teknis Infrastruktur sistem security gedung LPSK

Gambar rencana sistem keamanan Gedung LPSK

proses instalasi sistem security LPSK harus memperhatikan unsur keamanan dan
keselamatan kerja, kebersihan dan kerapihan hasil pekerjaan (penyedia wajib
membersihkan dan merapikan area kerja setelah pekerjaan selesai dilakukan).

6.5.1 Spesifikasi Sistem CCTV LPSK


Sistem CCTV LPSK di kategorikan berdasarkan lokasi pemasangan CCTV :
 CCTV system Gedung LPSK
 CCTV system Data Center dan Command Center
 CCTV system rumah aman

131
Sistem CCTV yang ditawarkan harus memenuhi spesifikasi sebagai berikut :

Spesifikasi
IP CCTV Dome Indoor 5MP IR Vari-focal
Overview : With solution and deep learning algorithm, network camera
has various intelligent functions, including face capture, perimeter
protection and people counting, which greatly improve the accuracy of
video analysis. The camera supports dust-proof function, waterproof
function and vandal-proof function, complying with the standards of IP67
and IK10 (Supported by some select models).
Face Detection
Face Detection technology can detect the face in the image.
With deep learning algorithm, the technology supports detecting,
tracking, capturing and selecting the best face image, and then outputs
face snapshot.
Face Attributes
With deep learning algorithm, the network camera can recognize face
attributes, such as gender, age, expression, glasses, mouth mask, and
beard.
Perimeter Protection
With deep learning algorithm, Perimeter Protection technology can
recognize human and vehicle accurately. In restricted area (such as
pedestrian area and vehicle area), the false alarms of intelligent detec-
tion based on target type (such as tripwire, intrusion, fast moving, parking
detection, loitering
detection and gathering detection) are largely reduced.
People Counting
With deep learning algorithm, People Counting technology
can track and process moving human body targets to realize the

132
accurate statistics of enter No., leave No., and In Area No. Working with
management platform, it outputs yearly/monthly/daily reports to meet
your requirements.
ePoE
Technology encompasses pure network systems where a single CAT6
cable can carry signals up to 300 m (984 ft) at 100 Mbps, 800 m (2625 ft)
at 10 Mbps.
Cyber Security
Network camera is equipped with a key security
technologies, such as security authentication and authorization, access
control, trusted protection, encrypted transmission, and encrypted
storage, which improve its security defense and data protection, and
prevent malicious programs from invading the device.
Protection (IP67, IK10, wide voltage)
IP67: The camera passes of strict test on dust and soak. It has dust-proof
function, and the enclosure can works normal after soaking in 1 m deep
water for 30 minutes.
IK10: The enclosure can stand the punch more than 5 times from a 5 kg
hammer falling from a height of 40 cm (Impact energy is 20J).
Wide voltage: The camera allows ±30% (for some power supplies)
input voltage tolerance (wide voltage range), and it is widely applied to
outdoor environment with instable voltage.
Image Sensor : 1/2.7” CMOS
Max. Resolution : 2592 (H) × 1944 (V)
RAM/ROM : 1 GB/128 MB
Scanning System : Progressive
Electronic Shutter : Speed Auto/Manual, 1/3 s–1/100000 s
S/N Ratio : > 56 dB
Minimum Illumination : 0.003 lux@F1.3 (Color, 30I RE) 0.0003 lux@F1.3

133
(B/W, 30I RE) 0 lux (Illuminator on)
Illumination Distance : Distance up to 80 m (262 ft)
Illuminator On/Off : Control Auto/Manual
Focal Length : 7 mm–35 mm
Max. Aperture : F1.3 (Constant)
Angle of View H: 31°–9°, V: 23°–7° (2592 × 1944) H: 32°–9°, V: 18°–5°
(2688 × 1520)
Close Focus Distance : 0.4 m–2.0 m (1.31 ft–6.56 ft)
DORI Distance
Lens W 190 m (623 ft) Detect
Lens W 76 m (249 ft) Observe
Lens W 38 m (125 ft) Recognize
Lens W 19 m (62 ft) Identify
Lens T 620 m (2034 ft) Detect
Lens T 248 m (814 ft) Observe
Lens T 124 m (407 ft) Recognize
Lens T 62 m (203 ft) Identify
Pan/Tilt/Rotation Range Pan: 0˚–355˚; Tilt: 0˚–65˚; Rotation: 0˚–355˚
Professional, intelligent
Face detection; track; optimization; snapshot; report high quality picture;
face enhancement; face exposure; face attribute extract, 6 attributes and
8 expressions: Gender, age, glasses, expressions (anger, calm, happiness,
sadness, disgust, surprise, confusion and fear), mask, beard; face matting
setting: face, single inch photo;three snapshot methods: real-time
snapshot, optimization snapshot, quality priority; face angle filter;
optimization time setting.
Perimeter Protection
Tripwire; intrusion; fast moving (the three functions support the
classification and accurate detection of vehicle and human); loitering

134
detection; people gathering; parking detection
People Counting
Support the counting of enter number, leave number, and pass number,
and displaying and outputting yearly/monthly/daily reports. Support the
counting of number in area, and 4 rules
configuration. Count number of people or stay time and link alarm.
Support queue management, and 4 rules configuration. Count number of
people or stay time and link alarm.
Smart Event
IVS Object Abandoned/Missing
Heat Map : Yes
Video
Compression : H.265,H.264,H.264B,H.264H, MJPEG (only supported by
sub stream)
Smart Codec : Smart H.265+/ Smart H.264+
Streaming Capability 3 Streams
Resolution : 2592 × 1944/2688 × 1520/2560 × 1440/2304 ×
1296/1080P (1920 × 1080)/1.3M (1280 × 960)/720P
(1280 × 720)/D1 (704 × 576/704 × 480)/VGA (640 ×
480)/CIF (352 × 288/352 × 240)
Frame Rate
Main Stream: 2592 × 1944 (1 fps–20 fps)
2560 × 1440 (1 fps–25/30 fps)
1920 × 1080 (1 fps–50/60 fps)
Sub Stream: D1 (1 fps–20/30 fps)
D1 (1 fps–50 fps)
Third Stream: 1080P (1 fps–17 fps)
Bit Rate Control : CBR/VBR
Bit Rate

135
H.264: 32 Kbps–8192 Kbps
H.265: 19 Kbps–8192 Kbps
Day/Night : Auto (ICR)/Color/B/W
BLC Mode : BLC/HLC/WDR (120 dB)
Scene Self-adaptation (SSA) : Yes
White Balance : Auto/Natural/Street Lamp/Outdoor/Manual
Gain Control Auto/Manual
Noise Reduction : 3D NR
Motion Detection : OFF/ON (4 areas, rectangular)
Region of Interest : Yes (4 areas)
Electronic Image Stabilization (EIS) : Yes
Smart Illumination : Yes
Defog : Yes
Flip : 0°/90°/180°/270°
Mirror : Yes
Privacy Masking : 8 areas
Audio Compression : G.711a, G.711Mu, G.726, G.723
Alarm Event
No SD card;SD card full;SD card error;network
disconnection;IP conflict;illegal access;motion
detection;video tampering;Defocus
Detection;scene changing;intrusion;tripwire;aban
doned object;missing object;fast moving;parking
detection;loitering detection;people
gathering;audio detection;people counting;face
detection;People counting in area;Stay alarm;People
No. exception detection;Queue Management
Network : RJ-45 (10/100 Base-T)
SDK and API : Yes

136
Cyber Security
Video encryption; firmware encryption;
configuration encryption; Digest; WSSE; account
lockout; security logs; IP/MAC filtering; generation
and importing of X.509 certification; syslog; HTTPS;
802.1x; trusted boot; trusted execution; trusted upgrade
Protocol
IPv4; IPv6; HTTP;TCP; UDP; ARP; RTP; RTSP; RTCP;
RTMP; SMTP; FTP; SFTP; DHCP; DNS; DDNS; QoS;
UPnP; NTP; Multicast; ICMP; IGMP; NFS; SAMBA;
PPPoE; SNMP; Bonjour
Interoperability
ONVIF (Profile S/Profile G/Profile T), CGI, Milstone,
Genetec, P2P
User/Host : 20 Users
Storage : NAS; FTP; SFTP; Micro SD card 256 GB
Browser :
IE (versions newer than IE8), Chrome,
Firefox, Safari (versions newer than Safari 12)
Management Software : Smart PSS, DSS, DMSS
Mobile Phone : iOS, Android
Interface
Audio Interface : 1/1 channel In/Out
Alarm
1 channel In: 5mA 5V DC
1 channel Out: 300mA 12V DC
Power Supply : DC 12V (±30%)/AC 24V (±30%)/PoE (802.3af)/ePoE
Power Consumption
Basic power consumption: 4.9W (12V DC); 5.1W

137
(24V AC); 5.2W (PoE)
Max. power consumption (max. stream + intelligent
function + IR LED + focus): 12.4W (12V DC); 11.9W
(24V AC); 11.6W (PoE)

Environmental
Operating Conditions : -30° C to +60° C (-22° F to +140° F)/Less than 95%
RH
Storage Conditions : -40° C to +60° C (-40° F to +140° F)
Protection Grade : IP67,IK10
SDK and API : Yes
Cyber Security : Video encryption; firmware encryption; configuration
encryption; Digest; WSSE; account lockout; security logs; IP/MAC filtering;
generation and importing of X.509 certification; syslog; HTTPS; 802.1x;
trusted boot; trusted execution; trusted upgrade
Interoperability : ONVIF (Profile S/Profile G/Profile T), CGI, Milstone,
Genetec, P2P
Storage : NAS; FTP; SFTP; Slot Micro SD card
Certifications : CE-LVD: EN62368-1
CE-EMC: Electromagnetic Compatibility Directive
2014/30/EU
FCC: 47 CFR FCC Part 15, Subpart B
UL/CUL: UL60950-1 CAN/CSA C22.2 No.60950-1-07
Construction
Casing : Metal
Dimensions : Φ159.0 mm × 117.9 mm (6.26” × 4.64”)
Net Weight : 0.95 kg (2.09 lb)
Gross Weight : 1.20 kg (2.65 lb)

138
5MP Network Camera Indoor Commad Center Built-in MIC, Built-in
Speaker
Overview :
"With solution and deep learning algorithm,
network camera has various intelligent functions, including face capture,
perimeter protection and people counting, which greatly improve the
accuracy of video analysis. The camera supports dust-proof function,
waterproof function and vandal-proof function, complying with the
standards of IP67 and IK10 (Supported by some select models. "
"Functions
Perimeter Protection
With deep learning algorithm, Perimeter Protection technology can
recognize human and vehicle accurately. In restricted area (such as
pedestrian area and vehicle area), the false alarms of intelligent detection
based on target type (such as tripwire, intrusion,
fast moving, parking detection, loitering detection and gathering
detection) are largely reduced.
People Counting
With deep learning algorithm, People Counting technology
can track and process moving human body targets to realize the
accurate statistics of enter No., leave No., and In Area No. Working with
management platform, it outputs yearly/monthly/daily reports to meet
your requirements."
"Active Deterrence
Active deterrence is to warn off intruders actively with white light and
siren even before users are aware of the incidence. Once an intursion
is detected, the white light will turn on and the siren will buzzer to alert
the intruder. The white light can be set to Normally on or Flash, the
content of siren is configurable.

139
Protection (IP67, wide voltage)
IP67: The camera passes of strict test on dust and soak. It has dust-
proof function, and the enclosure can works normal after soaking in 1 m
deep water for 30 minutes.
Wide voltage: The camera allows ±30% (for some power supplies)
input voltage tolerance (wide voltage range), and it is widely applied to
outdoor environment with instable voltage. "
Image Sensor 1/2.7” : 5Megapixel progressive scan CMOS
Max. Resolution : 2592 (H) × 1944 (V)
RAM/ROM : 512 MB/128 MB
Scanning System : Progressive
Electronic Shutter Speed : Auto/Manual, 1/3 s–1/100000 s
S/N Ratio : > 56 dB
Minimum Illumination : 0.005 Lux@F1.6
Illumination Distance : Distance up to 50 m (164ft)
Illuminator On/Off Control : Auto/Manual
Illuminator Number : 1 IR, 1 LED
Lens Type : Fixed-focal
Mount Type : Board-in
Focal Length : 2.8 mm,
Max. Aperture : F1.6
Angle of View : H: 102°, V: 71°/H: 84°, V: 58°/H: 51°, V: 37°
Aperture Type : Fixed
Close Focus Distance : 0.9 m (2.95 ft)
DORI Distance
Lens 2.8mm :
56m(184ft) Detect
22m(72ft) Observe
11m(36ft) Recognize

140
6m(20ft) Identify
Pan/Tilt/Rotation Range : Pan: 0˚–360˚; Tilt: 0˚–78˚; Rotation: 0˚–360˚
Artificial Intelligence
"Perimeter Protection : Tripwire; intrusion; fast moving (the three
functions support the classification and accurate detection of vehicle and
human); loitering detection; people
gathering; parking detection"
"People Counting : Support the counting of enter number, leave
number, and pass number, and displaying and outputting
yearly/monthly/daily reports.
Support the counting of number in area, and 4 rules configuration. Count
number of people or stay time and link alarm.
Support queue management, and 4 rules configuration. Count number of
people or stay time and link alarm."
General Intelligence
"Event Trigger : Motion detection, Video tampering , Scene
changing, Network disconnection , IP address conflict, Illegal Access,
Storage anomaly"

General Intelligence : Object Abandoned/Missing


Heat Map : Yes
Video
Compression : H.265,H.264,H.264B,H.264H, MJPEG (only supported by
sub stream)
Smart Codec : Smart H.265+/ Smart H.264+
Streaming Capability : 3 Streams
"Resolution : 2592 × 1944/2688 × 1520/2560 × 1440/2304 ×
1296/1080P (1920 × 1080)/1.3M (1280 × 960)/720P

141
(1280 × 720)/D1 (704 × 576/704 × 480)/VGA (640 ×
480)/CIF (352 × 288/352 × 240) "
Frame Rate
Main Stream : 2592 × 1944 (1 fps–20 fps)
2560 × 1440 (1 fps–25/30 fps)
1920 × 1080 (1 fps–50/60 fps)
Sub Stream : D1 (1 fps–20/30 fps)
D1 (1 fps–50 fps)
Third Stream : 1080P (1 fps–17 fps)
Bit Rate Control : CBR/VBR
Bit Rate :
H.264: 32 Kbps–8192 Kbps
H.265: 19 Kbps–8192 Kbps
"Day/Night : Auto (ICR)/Color/B/W
BLC Mode : BLC/HLC/WDR (120 dB)"
"White Balance : Auto/Natural/Street Lamp/Outdoor/Manual.
Gain Control : Auto/Manual.
Noise Reduction : 3D DNR.
Motion Detection : Off/On (4 Zone, Rectangle).
Region of Interest : Off/On (4 Zone).
Smart Illumination : Yes.
Defog : Yes.
Flip : 0°/90°/180°/270°.
Mirror : Off/On.
Privacy Masking : Off/On (4 Area, Rectangle)."
Audio Compression : G.711a, G.711Mu, G.726, AAC, G.723
"Alarm Event : No SD card;SD card full;SD card error;network
disconnection;IP conflict;illegal access;motion detection;video
tampering;Defocus Detection;scene changing;intrusion;tripwire;aban

142
doned object;missing object;fast moving;parking detection;loitering
detection;people gathering;audio detection;people counting;face
detection;People counting in area;Stay alarm;People No. exception
detection;Queue Management;White light alarm;Voice alarm (11 Built-in
voices, and custom voices are supported."
Network : RJ-45 (10/100 Base-T)
SDK and API : Yes
Protocol : IPv4;IPv6;HTTP;HTTPS;TCP;UDP;ARP;RTP;RTSP;RTCP
;RTMP;SMTP;FTP;SFTP;DHCP;DNS;DDNS;QoS;UPnP
;NTP;Multicast;ICMP;IGMP;NFS;PPPoE;802.1x;SNMP
Interoperability : ONVIF (Profile S/Profile G/Profile T), CGI, Milstone,
Genetec, P2P
User/Host : 20 Users
Storage : NAS;FTP;SFTP; Cloud; Slot Micro SD card
"Browser : IE (versions newer than IE8), Chrome,
Firefox, Safari (versions newer than Safari 12)."
"Management Software : Smart PSS, DSS, DMSS
Mobile Phone : iOS, Android"
"Audio Interface : 1/1 channel In/Out, Built-in MIC, Built-in Speaker.
Alarm :
1 channel In: 5mA 5V DC
1 channel Out: 300mA 12V DC"
Power Supply : DC 12V (±30%), PoE (802.3af)
Power Consumption : <7.2W
Operating Conditions : -40°C to +60°C (-40°F to +140°F)/Less than 95% RH
Storage Conditions : -40°C to +60°C (-40°F to +140°F)
Protection Grade : IP67
Certifications : CE-LVD: EN62368-1, CE-EMC: Electromagnetic
Compatibility Directive, 2014/30/EU, FCC: 47 CFR FCC Part 15, Subpart B,

143
UL/CUL: UL60950-1 CAN/CSA C22.2 No.60950-1-07
"Construction
Casing : Metal, plastic
Dimensions : Φ122 mm × 113.5 mm (4.80” × 4.47”)
Net Weight : 0.49 kg (1.08 lb)
Gross Weight : 0.65 kg (1.43 lb)"

Video Management System Surveillance


"It supports up to 1,000 cameras, and this number can be larger with
distributed deployment. It has a 3.5"" chassis with up to 15 hot-swapping
hard drives for center storage, providing a very powerful
all-in-one solution for projects. "
Hardware Specification
System
Main Processor : Intel i5-6600, 64 bits 4 Core Processor
Operating System : Embedded Linux
Memory : 8 GB
Motherboard : Embedded board (7 × 24 operation)
"Hard Disk Hot swap : Support hot swap and online replacement
Hard Disk Compatibility : SAS/SATA disk"
Key Components
Service
· Central Management Service (CMS)
· Device Management Service(DMS)
· Storage Service (SS)
· Media Transmission Service (MTS)
· Auto Register Service (ARS)
· Alarm Dispatch Service(ADS)
· Picture Transfer Service (PTS)

144
· Object Storage Service (OSS)
Client
· Windows PC Client
· DSS Mobile 2
· DSS Mobile for VDP
Running Environments
Operating System
· OS for Windows Control Client:
Win7 - 32 bit / Win7 - 64 bit/ Win10 - 64 bit
· OS for DSS Mobile Client:
IOS: IOS 9.0 and above
Android: Android 4.4 and above
Hardware
· Hardware for Control Client
"Recommended
CPU : Intel Core i5, 64 bits 4 Core Processor
Memory : 8 GB
Graphics Card : NVIDIA® GeForce®GT 730
Hard Drive Capacity : 200 GB free for DSS Control Client
Ethernet Port : 1000 Mbps"
"Minimum
CPU : Intel Core i3, 64 bits 4 Core Processor
Memory : 4 GB
Graphics Card : Intel® HD Graphics 4400
Hard Drive Capacity : 100 GB free for DSS Control Client
Ethernet Port : 1000 Mbps
Hardware for Mobile Client
iPhone : iPhone 5S and above
Android : Resolution: 1280 × 720 and above

145
RAM: 3 GB and above"
"Browser Version
· Internet Explorer: 9 and above
· Chrome: 52 and above
· Firefox: 51 and above
Features
Easy Expansion
· 3.5"" chassis with up to 15 hot-swapping hard drives and extends
storage through ISCSI.
· Up to 1,000 video channels per server and the number can be larger
with distributed deployment.
High Reliability
· Hot standby application of two servers ensures 7 × 24h stable
operation.
· N+M distributed deployment ensures 7 × 24h stable operation.
High Compatibility
· Devices: Network camera, network speed dome, decoder, NVR, DVR,
ANPR, access control device, VDP, and alarm controller.
· Connect third-party devices through standard ONVIF protocol."
" Main Functions
System
· Support hot standby for main server.
· Support distributed deployment.
· Support LAN and WAN deployment.
1. Web Manager
· Business Configuration
Organization Management
· Device group management through organization.
Device Management

146
· Initialize devices.
· Add devices through auto search, IP, Domain, IP segment, auto register
(for 3G, 4G, DHCP device).
· Manage devices such as network camera, network speed
dome, NVR, DVR, access control, video intercom, alarm controller, and
decoder.
· Add third-party devices through ONVIF protocol.
· Modify device IP address.
· Modify the password of added device.
· Import intercom devices.
· Bind the associated camera: Link cameras for alarm video display"
"Role and User Management
· Manage user permissions by role (device permission, control
permissions).
· User can be assigned with roles to obtain the corresponding
permissions.
· User can be restricted by MAC and expiry information.
Set PTZ permission for user.
· User can be locked.
· Support importing domain user and assigning roles to the user.
Event Management
· Alarm type: Device, video channel, audio detection, alarm input,
IVS alarm, thermal, vehicle blocklist, access control, face arming,
emergency, entrance alarm.
· Alarm scheme: All day template, weekday template, weekend
template and custom template.
· Alarm priority: Low, medium, high.
· Linkage: Recording, snapshot, live video, alarm output, PTZ, video wall,
e-mail, door control, and user notification.

147
Storage
· Support edge storage and central storage.
· Central storage: Extend storage through iSCSI.
· Server disk configuration for picture storage involving face detection
and recognition, alarms, and object detection.
· Create recording plan by time template: All day template, weekday
template, weekend template and custom template.
· Back up video as scheduled from the edge storage devices such as
EVS, NVR, and DVR.
· Back up video from edge storage devices through Wi-Fi.
· Disk quota: Group the disks, and cameras can be allocated to different
disk groups.
Map
· Google online map, Google offline map, raster map
· Up to 8 levels of submap.
· Configure hot spots (camera, alarm input, access control channel) and
sub maps on the map."
"Video Wall
· Display or hide the screen ID.
· Support screen combination.
· Bind the decoding channel with the corresponding screen.
Face Database
· Face library management.
· Add face one by one.
· Import faces in batches.
· Set person type.
· Send face database to face recognition devices, and configure the
similarity.
Vehicle Blocklist

148
· Vehicle blocklist management.
· Set start time and end time for vehicle blocklist.
· Vehicle blocklist arming and disarming.
· Import and export vehicle blocklist."
"Video Intercom
· Residence configuration: Set whether to enable Building No. and Unit
No.
· Issue VTH contact list to VTO.
· Set VTH private password for unlocking VTO.
· View, delete and freeze users of DSS Mobile for VDP.
· System Maintenance
Backup and Restore
· Automatically back up system database (daily, weekly, monthly).
· Manually back up system database.
· Restore system database from server or local file.
System Dashboard
· Overview and detailed system information.
· Status of CPU, storage, bandwidth.
· Service, device and user online information, device health report.
· Event information statistics : Total and processed events.
· Source information: Video channel, alarm channel."
"Log
· System, admin, client log.
· Log search and export.
System Configuration
· Configure data retention duration of logs, alarms, heatmap, face
recognition, vehicle records, and people counting data.
· Time synchronization: Timed synchronization and device connection
synchronization.

149
· Email server configuration.
· Active directory configuration.
· Support importing HTTPS certificate.
Service Management
· Delete sub servers.
· Enable or disable sub servers.
· Manually or automatically assign devices to different servers to
balance server load.
2. Control Client
· Basic Video Management Features
Live View
· Display device tree with offline devices shown or hidden.
· Display device IP address or name on the device tree.
· View live video."
"· Common layout (1/4/6/8/9/13/16/20/25/36/64) and custom layout.
· PTZ control.
· Electric focus.
· Manual recording (store on PC or central storage).
· Snapshot.
· Instant playback.
· Digital zoom.
· Fisheye dewarp.
· Fisheye-PTZ smart track.
· Panoramic camera smart track.
· Bullet-PTZ smart track.
· Audio talk.
· Set alarm window.
· Turn on/off audio in live view.
· Turn on/off the IVS display in live view.

150
· Region of interest: Divide one window into 4 or 6 parts, one for whole
image, the others for the details.
· Display map in live view.
· Save the current live view as a view.
· Up to 4 live view tabs for multi-display operation.
· Support adding channels to favorites.
· Video tour by device, organization, favorites, or view.
· Quickly switch to playback.
· Support NKB1000.
· Adjust the video image.
· Adjust the display mode (full screen and original).
· Live video on map.
· Basic device setting: Camera properties, video, and audio."
"Playback
· Play videos from the front-end devices or central storage.
· Video filter: Normal, motion, alarm.
· Synchronous play.
· Reverse playback of central record.
· Digital zoom.
· Slow and fast forward (up to 64X and 1/64X).
· Frame-by-frame playback.
· Lock or mark the important records for central storage.
· Download video in the formats of .avi, .dav, .mp4, and .asf.
· Turn on/off the IVS display in playback.
· Video decoding on video wall.
· Fisheye dewarp.
· Adjust video image.
· Snapshot.
· Quickly switch to live view.

151
· Adjust the display mode (full screen and original).
· Common layout (1/4/6/8/9/13/16/20/25/36) and custom layout.
· Support search by thumbnail.
· Support smart search."
"Download Center
· Download records from central storage or devices in the formats of
.avi, .dav, .mp4, and .asf.
· Download records by timeline, file or tag.
· Support multi-task download.
Event
· Real-time and history alarm information.
· Alarm details: Live video, records and pictures from related camera,
and alarm source location on the map."
"· Acknowledge alarms.
· Arming control for alarm source.
· Forward the alarm to relevant user.
· Manually send alarm email to relevant person.
· Handle alarms and fill out the handling comments.
· Search for alarms by alarm source, alarm time, status, handle user, and
priority.
· Search for alarms and export alarm list."
"Video Wall
· Create different video wall tasks.
· View real-time video.
· Real-time video on video wall.
· Manually or automatic video wall display.
· Manage video wall split.
· Change stream type of video channel.
· Turn on/off audio.

152
· Add box, turn on/off screen and get video stream to control client.
· Video tour in one screen.
· Scheduled plan: Set the running task on timeline.
· Tour plan: Loop display of tasks at specific intervals.
· Support NKB1000 for video wall control."
"Map
· View live and recorded videos on the map.
· Support area or length measurement on GIS map.
· Support visible range and initial angle (only available on select PTZ
models).
· Alarm source turns red and flickers on the map when alarm occurs.
· Remote access control.
· Access Control Features
Personnel Management
· Add, edit and delete people and department.
· Upload face pictures by selecting files or taking pictures.
· Import personnel information in batches.
· Issue cards and fingerprints through USB reader or devices.
· Authorize by door group.
· Authorize video intercom devices.
· Card, password, fingerprint and face authentications.
· Guest, VIP, normal and blocklist personnel management.
· Extract person information (ID, card, fingerprint, IR face feature
code) from device.
· Support setting super passwords for access control devices.
· Support holiday management."
"Access Control
· Door status and door events monitoring.
· View related videos.

153
· Lock or unlock doors by one key.
· Global operation of opening or closing doors.
· Support access control channel configuration.
· Advanced door rules, such as anti-passback, first card unlock,
inter-door lock, multi-card unlock, and remote verification.
· View logs and records from device.
· Support device log search.
Video Intercom
· Video intercom between VDP devices based on SIP protocol.
· Video intercom between VDP devices and the command center.
· Release text information to VTH."
"· View video intercom logs.
· Call management: Support configuring device groups, management
groups, and relationship groups to enable call between specific groups.
Visitor Management
· Support visit registration and appointment.
· Support issuing access permissions by card or face recognition.
· Support card-swiping record query.
· Support visitor record query."
"Vehicle Entrance
· Overview of entrance and exit information: Number of parking spaces
and remaining parking spaces, traffic statistics, parking turnover, and
parking utilization rates.
· View real-time number plate recognition.
· Edit parking-lot information such as total and available spaces and
parking lot name.
· Support configuration of barrier control rules for normal and
zero-space-left cases.
· Support searching for vehicle records, on-site vehicles, and ANPR

154
details.
· Manage owners, vehicles and cards.
· Bind LED screen with ITC or spot detector device.
· Open barrier gate remotely or by swiping card on VTO.
· Forced leave for existing vehicles.
· Vehicle records search and export.
· Support daily, weekly, monthly, and annual statistics of vehicle access
records.
· Advanced Features"
"Face Recognition
· Automatic face capture.
· Extract face attribute information from face snapshot.
· Real-time face comparison.
· Quickly register face to face library.
· Search for face by face attribute.
· Search for face by uploading a face image.
· Search for face comparison records.
· Generate travel routes for specific faces.
· Generate daily, weekly, monthly attribute report based on gender and
age.
Object Detection
· Real-time face capture by camera, and display information about
human, motor vehicles, and non-motor vehicles.
· Extract attribute information from snapshots.
· Search for objects in the snapshot database quickly by setting up
criteria.
· Generate daily, weekly, monthly attribute report based on human,
motor vehicles, and non-motor vehicles."
"Flow Analysis

155
· People counting: Provides daily, weekly, monthly, yearly reports.
· Heatmap.
· Export people counting and heatmap data.
· Dwell time reports.
ANPR
· Real-time number plate recognition.
· View vehicle records.
· Generate vehicle track based on number plate and time.
· Search for arming records."
"Alarm Controller
· Support custom alarm types.
· Update the status of alarm controller.
· Global arming, disarming; arming or disarming specific zones or
subsystems.
· Zone status control: Bypass, Isolate and Normal.
· Cancel alarms.
· Control Client Information and Configuration
Control Client Information
· Show status of network, CPU, and memory usage.
· User information.
· Support auto-discovery of online DSS services.
· Support modifying passwords.
· Support client lockout."
"Control Client Configuration
· Basic settings: Language, theme, resolution, time synchronization,
automatic login, auto-start on power-on, whether to restore the last live
view, adaptive intercom parameters, and device nodes display.
· Video settings: Default window split, split number threshold for
switching to sub stream, playback modes, custom video buffer time,

156
instant playback duration, GPU decoding, closing video after a specified
time of silence, and switching to main stream on full screen.
· Video playback: Default window split, recording stream type, and
extract-frame playback.
· Snapshot settings: Snapshot format, saving path, naming rules,
continuous snapshot interval, and number of continuous snapshots.
· Recording: Saving path, naming rules, and recording file size
· Alarm: Alarm sound, loop play, map flash warning, and associated
video play.
· Video wall: Stream type, tour interval, split number threshold for
switching to sub stream, and switching to main stream on full screen.
· View shortcuts for PC keyboard and NKB."
"3. Mobile Client
History Record
· Show recently viewed channels; open live video or playback through
history records.
· Display up to 20 latest history records.
Live View
· Open more than one channel at the same time, up to 16 channels.
· Three stream types: HD (high definition), SD (standard definition), FL
(Fluency).
· Support PTZ control.
· Support horizontal screen play.
· One-key switch to playback.
· Snapshot, local record, audio talk.
· Supports fisheye dewarp.
Playback
· Play back records from device or central storage (Up to 8X and 1/8X).
· The calendar shows whether there is video on that day.

157
· Support snapshot.
· Manually start recording for local storage.
· Support 1X, 2X, 3X, 4X, 1/2X, 1/4X, 1/8X playback."
"Face Recognition
· Support searching the face database or snapshot records for target
faces by uploading a face picture.
· Support face database management."
"Object Detection
· Search for objects classified by people, vehicle and non-motor
vehicle.
Alarm Center
· Alarm subscription.
· Query for alarm messages by category.
· Claim and handle alarm messages.
· History alarm message query.
Map
· Support Google map and raster map.
· Display video channels on the map.
· View live and recorded videos.
Access Control
· Open or close doors remotely.
· View and delete personnel.
Video Intercom
· Support video intercom.
· Support calling VDP devices.
· View call records.
Favorite
· Quickly view videos of channels in the favorites.
Files Management

158
View local pictures and videos."
Interface
Number of Network Ports : 4 Ethernet ports (100/1000 Mbps)
RS-485 : Reserved
RS-232 : Reserved
USB : 2 × USB 2.0 on front panel; 2 × USB 3.0 on rear panel
HDMI : 3 HDMI ports
VGA : 1 VGA port
Storage
" HDD Installation : Support 15 HDDs (3.5"") for video or picture storage
(8 TB per HDD)
Storage : Up to 200 TB per server
HDD Mode : Single; raid 0/1/5/6/10
Bandwidth of Video Storage per Server : 600 Mbps"
Other
"Power : Maximum power 315W; stable power 210W
Working Environment Temperature : 0°C to 40°C (32°F to 104°F)
Working Environment Humidity : 10%–80% (RH) (non-condensation)
Storage Environment Temperature : -20°C to +70°C (-4°F to +158°F)
Storage Environment Humidity : 5%–90% (RH) (non-condensation)
Working Altitude : 0 m–5000 m (0 ft–16,404.2 ft)
Weight (Without Package) : 19.1 kg (42.1 lb)
Dimension : 444.8 mm × 133.2 mm × 522.2 mm
(17.5"" × 5.24"" × 20.6"")
Installation Method : Standard 19-inch rack mount
Secondary Development : Platform SDK provided"
Performance Specification
Organization, User and Role
"Organization : 10 hierarchies, 999 organizations per hierarchy

159
Role (User Permission) : 100
User : 50 online users and 200 total users
User for VDP Mobile APP : 500 online users and 5,000 total users"
Total Device : 2,000 devices
"Video Device and Channel
Total Video Device and Channel : 500 devices; 1,000 channels
Auto-Register : 500 devices; 1,000 channels
ONVIF : 200 devices; 400 channels
ANPR Device : 64 channels (6 pairs for entrance and exit)
Face Recognition Channel : 100 channels
Object Detection Channel : 20 channels
Heatmap Channel : 64 channels
People Counting Channel : 100 channels"
"ACS Device
Access Control : 200 IPs; 512 Doors
VDP : 2,000 IPs (Unit VTO no more than 200)
Alarm Device
Alarm Controller : 10 IPs; 100 channels
Media Transmission Server
Video Input per Server : 600 Mbps
Video Output per Server : 600 Mbps"
"Playback and Download
Playback Bandwidth per Server : 100 Mbps
Download Task : 5
Maximum Record Plan : 100
Alarm
Alarm Rules : 200
Map
Hierarchy : 8 hierarchies

160
Submap : 32 per hierarchy
Map Size of Raster Map : 14.7 MB
Spots per Map (e.g. Camera Alarm Input) : Up to 300 (GIS and Raster)"
"Face Recognition
Face Library : 50
Total Persons for Face Library : 5,000
Face Images Imported Each Time : 1,000"
ANPR Vehicle Blocklist : 100
"Data Information
Alarm Records : 5,000,000¹
Face Snapshot Records :5,000,000¹
Number Plate Recognition Records : 5,000,000¹
Violation Records : 5,000,000¹
Average Speed Records : 5,000,000¹
People Counting Records : 5,000,000¹
Heatmap Records : 5,000,000¹
Video Intercom Records : 5,000,000¹
Log : 5,000,000¹"
"Personnel Management
Person : 5,000
Card : 5,000
Face : 5,000
Fingerprint : 5,000"
Total Event : 240 per second²
"Event without Picture
Alarm without Picture : 240 per second²
Alarm Controller Event : 40 per second²
Access Control Event : 16 per second²"
"Event with Picture (for ANPR)

161
ANPR : 12 per second (12 per 3 s for entrance and exit )²
Event with Picture (for others)
Alarm with Picture : 40 per second²
Face Capture : 120 per second²
Object Detection : 40 per second²"
Distributed System
Number of Sub Server : Up to 5
"Device and Channel
Total Device Number
Total Device Number : 5,000 devices"
"Video Device and Channel
Total Number of Video Devices and Channels : 2,500 devices; 5,000
channels.
Auto-register : 2,500 devices; 5,000 channels
ONVIF : 400 devices; 800 channels
ANPR Device : 320 channels
Face Recognition Channel : 500 channels
Object Detection Channel : 100 channels
Heatmap Channel : 320 channels
People Counting Channel : 500 channels"
Access Control : 500 IPs; 2,500 doors
Total Event : 480 per second²
"Event without Picture
Alarm without Picture : 480 per second²
Access Control Event : 96 per second²"
ANPR Event : 120 per second (120 per 3 s for entrance and exit)²
"Event with Picture (for others)
Alarm with Picture : 120 per second²
Face Capture : 280 per second²

162
Object Detection : 80 per second²"
"1: The record number depends on the disk capacity, and the maximum
record quantity is 5,000,000.
2: The sum of event of each type cannot exceed the total number of
events. One piece of access controller event is
equivalent to three general alarms without pictures; one piece of alarm
controller event is equivalent to a general alarm without picture; one
piece of alarm with picture or one object
detection is equivalent to three face detection events."

16-Port FE PoE+ 1-Port Gigabit Combo PoE Switch


"> Compliant IEEE 802.3, IEEE 802.3u, IEEE802.3ab, IEEE802.3x standards
> Supports IEEE802.3af, IEEE802.3at, Hi-PoE standards
> Supports normal working mode, port isolation (VLAN) mode, monitoring
mode, network extend mode."

Switch Server 16 Port


"Features
· Layer 2 network management PoE switch
· Support IEEE802.3af, IEEE802.3at standard
· Support Hi-PoE 60W
· Network Redundancy: STP/RSTP/MSTP
· Support IPv4/IPv6, and DHCP
· Network management based on SNMP
· Configuration: Web, Telnet, CLI Command
· QoS (IEEE802.1p/1Q), CoS/ToS to Increase Determinism
· Enhanced Network Security with IEEE802.1X, SNMP v1/v2c/
v3, HTTPS, and SSH/SSL
· Large data cache(4M), real-time transmission

163
· MAC auto study and aging, MAC address list capacity is 8K
· EMC high protection design"

IP CCTV Bullet Outdoor 4MP IR


"· 4-MP 1/1.8"" CMOS image sensor, low luminance, and high definition
image.
· Outputs max. 4 MP (2688 × 1520)@50/60 fps.
· H.265 codec, high compression rate, ultra-low bit rate.
· ROI, SMART H.264 +/H.265+, flexible coding, applicable to various
bandwidth and storage environments.
· Built-in IR LED, and the max. illumination distance is 60 m.
· Rotation mode, WDR, 3D NR, HLC, BLC, digital watermarking, applicable
to various monitoring scenes.
· With deep learning algorithm, it supports video metadata, face
detection,face recognition,people counting, perimeter protection, etc.
· Supports P-Iris, the camera can control the iris more precisely for better
image effect.
· Alarm: 3 in, 2 out; audio: 1 in, 1 out; RS485, BNC, supports max. 256 G
Micro SD card.
· 12 VDC/24 VAC/PoE power supply (the power ports are different
depending on the power supply).
· IP67, IK10 protection grade.
· 12 VDC power output, max. current 165 mA , easy for installation
· Anti-corrosion coating (optional)."
"Functions
Smart H.265+ & Smart H.264+
With advanced scene-adaptive rate control algorithm, smart
encoding technology realizes the higher encoding efficiency than H.265
and H.264, provides high-quality video, and reduces the cost of storage

164
and transmission.
Starlight+
With advanced image processing technology, optical technology, and
image sensor of large target surface, Starlight+ technology can provide
clear colorful video in the environment of ultra-low illuminance.
It applies to various environments of low illuminance. "
"Video Metadata
With deep learning algorithm, Video Metadata technology can detect,
track, capture vehicle, non-motor vehicle and people, and select the best
images, and extract attributes."
"Perimeter Protection
With deep learning algorithm, Perimeter Protection technology can
recognize human and vehicle accurately. In restricted area (such as
pedestrian area and vehicle area), the false alarms of intelligent detection
based on target type (such as tripwire, intrusion, fast moving, parking
detection, loitering detection and gathering detection) are largely
reduced.
People Counting
With deep learning algorithm, People Counting technology
can track and process moving human body targets to realize the
accurate statistics of enter No., leave No., and In Area No. Working with
management platform, it outputs reports to meet your requirements."
"Face Detection Technology can detect the face in the image. With deep
learning algorithm, the technology supports detecting, tracking, capturing
and selecting the best face image, and then outputs face snapshot.
Face Recognition Technology extracts the features of captured
faces and compares them with that in face database to recognize the
person identity. "
"Cyber Security

165
Network camera is equipped with a key security
technologies, such as security authentication and authorization, access
control, trusted protection, encrypted transmission, and encrypted
storage, which improve its security defense and data protection, and
prevent malicious programs from invading the device. "

"Technical Specification
Camera"
Image Sensor 1/1.8" CMOS Max. Resolution 2688 (H) × 1520 (V)
ROM 4 GB RAM 2 GB Scanning System Progressiv.
Electronic Shutter Speed Auto/Manual 1/3 s–1/100,000 s
S/N Ratio >56 dB
Min. Illumination :
"0.001 Lux@F1.2 (Color, 30 IRE)
0.0002 Lux@F1.2 (B/W, 30 IRE)
0 Lux (Illuminator on) "

Illumination Distance 60 m (196.85 ft)


Illuminator On/Off Control Auto; Manual; Zoomprio
Illuminator Number 4 (IR LED)
Lens Type Motorized vari-focal
Focal Length 2.7-12 mm
Max. Aperture F1.2
Iris Control : Auto; P-iris
Close Focus Distance : 1 m (3.28 ft)
DORI Distance
Lens W Detect 60.1 m (197.18 ft), Lens W Observe 24 m (78.74 ft), Lens
W Recognize 12 m (39.37 ft), Lens W Identify 6 m (19.69 ft)

166
Lens T Detect 128.7 m (422.24 f), Lens T Observe 51.5 m (168.96 ft), Lens
T Recognize 25.7 m (84.32 ft), Lens T Identify 12.9 m (42.32 ft)
Field of View
"Horizontal: 114° (W)–48° (T)
Vertical: 59° (W)–27° (T)
Diagonal: 141° (W)–55° (T) "
Smart Event IVS : Abandoned object; missing object
Professional, intelligent
"IVS (Perimeter Protection) : Intrusion, tripwire, fast moving (the three
functions support the classification and accurate detection of vehicle and
human); loitering detection, people
gathering, and parking detection."
"Face detection; track; snapshot; snapshot optimization;
optimal face snapshot upload; face enhancement; face
exposure; face attributes extraction including 6 attributes
(gender, age, glasses, expressions, mask, and beard) and
8 expressions (angry, sad, disgusted, scared, surprised,
calm, happy, confused); face snapshot set as face or
one-inch photo; snapshot strategies (real-time snapshot,
quality priority and optimization snapshot); face angle
filter; optimization time setting."
"Face Recognition, Face detection; track; snapshot; snapshot
optimization; optimal face snapshot upload; face enhancement; face
exposure; face attributes extraction including 6 attributes (gender, age,
glasses, expressions, mask, and beard) and 8 expressions (angry, sad,
disgusted, scared, surprised, calm, happy, confused); face snapshot set as
face or
one-inch photo; snapshot strategies (recognition priority
and optimization snapshot); face angle filter; optimization

167
time setting. Support 5 face databases; register one by
one or in batches; support face recognition similarity
settings and face comparison on the basis of 100,000
face databases."
People Counting : Tripwire people counting and people counting in area;
generating and exporting report (day/month/year); queue management
and exporting report (day/month); 4 rules can be set for tripwire, people
counting in area and queue management.
"Video Metadata : Motor vehicle, non-motor vehicle, face, human
detection; track; snapshot; snapshot optimization;
optimal face snapshot upload.
Motor vehicle attributes: license plate, vehicle type,
vehicle color, vehicle logo, seatbelt, smoking, calling,etc.
Non-motor vehicle attributes: type, color, number of
people, top type and color ,helmet.
Human body attributes: top/bottom type and color, bag,
hat, gender, and umbrella.
Face attributes: gender, age, expressions, glasses, face
mask and beard."
"Smart Search : Work together with Smart NVR to perform refine
intelligent search, event extraction and merging to event videos"
Video Compression H.265; H.264; H.264H; MJPEG (Only supported by the
sub stream)
Smart Codec Smart H.265+; Smart H.264+
"Video Frame Rate
Main Stream: 2688 × 1520 (1–50/60 fps)
Sub stream: 704 × 576 (1–25 fps);704 × 480 (1–30 fps)
Third stream: 1920 × 1080 (1–25/30 fps)
Fourth stream: 1920 × 1080 (1–25/30 fps)

168
Fifth stream: 704 × 576 (1–25 fps);704 × 480 (1–30 fps)"
Stream Capability 5 streams
"Resolution
4M (2688 × 1520); 3M (2304 × 1296); 1080p (1920 ×
1080); 1.3M (1280 × 960); 720p (1280 × 720); D1 (704
× 576/704 × 480); VGA (640 × 480); CIF (352 × 288/352
× 240)"
"Video Bit Rate H.264: 32 kbps–10240 kbps
H.265: 12 kbps–9984 kbps. Bit Rate Control
CBR/VBR."
Day/Night Auto (ICR)/Color/B/W
WDR 140 Db, BLC : Yes, HLC : Yes
White Balance Auto; natural; street lamp; outdoor; manual; regional
custom
Gain Control Auto; Manual
Noise Reduction : 3D NR
Motion Detection : OFF/ON (4 areas, rectangular)
Region of Interest (RoI) : Yes (4 areas)
Image Stabilization : Electronic Image Stabilization (EIS)
"Smart Illumination : Yes. Defog : Yes. Image Rotation :
0°/90°/180°/270° (Support 90°/270° with 2688 × 1520
resolution and lower).
Mirror : Yes
Privacy Masking : 4 areas"
"Alarm Event : No SD card; SD card full; SD card error;
SD card durability warning; network disconnection;
IP conflict; illegal access; security exception; motion
detection; video tampering; tripwire; intrusion; fast
moving; abandoned object; missing object; loitering

169
detection; people gathering; parking detection; scene
changing; audio detection; defocus detection; external
alarm; face detection; video metedata; people counting
in area; people counting; queue management"
Network Port : RJ-45 (10/100/1000 Base-T)
SDK and API : Yes
"Cyber Security : Video encryption; Firmware encryption; Configuration
encryption; Digest; WSSE; Account lockout; Security logs; IP/MAC filtering;
Generation and importing of X.509 certification; syslog; HTTPS; 802.1x;
Trusted boot; Trusted
execution; Trusted upgrade"
"Network Protocol
IPv4; IPv6; HTTP; TCP; UDP; ARP; RTP; RTSP; RTCP; RTMP;
SMTP; FTP; SFTP; DHCP; DNS; DDNS; QoS; UPnP; NTP;
Multicast; ICMP; IGMP; NFS; SAMBA; PPPoE; SNMP"
Interoperability : ONVIF (Profile S/Profile G/Profile T); CGI; Milestone; P2P
User/Host : 20 (Total bandwidth: 80 M)
Storage : FTP; SFTP; Micro SD card (support max. 256 GB); NAS
"Browser With plug-in:
IE: IE 8 and later
Chrome: 45 and earlier
Firefox: 46 and earlier
Safari: 12 and earlier
Without plug-in:
Edge
Chrome: 45 and later
Firefox: 46 and later
Safari: 12 and later"
Management Software : Smart PSS; DSS; DMSS

170
Mobile Client : iOS; Android
"Certifications
CE-LVD: EN62368-1;
CE-EMC: Electromagnetic Compatibility Directive
2014/30/EU;
FCC: 47 CFR FCC Part 15, Subpart B;
UL/CUL: UL62368-1 & CAN/CSA C22.2 No. 62368-1-14;
UL 50E NEMA Type 4X (optional) "
"Port RS-485 : 1 (baud rate range:1200 bps–115200 bps)
Audio Input : 1 channel (RCA port)
Audio Output : 1 channel (RCA port)"
Protection Grade : IP67, IK10, Anti-Corrosion Protection: NEMA 4X
(optional)
Junction Box
Pole mount

2MP 25x Starlight PTZ Network Camera Rumah Aman


25x optical zoom, Digital Zoom 16x, Starlight technology, H.265
Encoding, Auto-tracking and IVS (Tripwire, Intrusion,
Abandoned/Missing) , Max. 50/60fps@1080P, Support PoE+, IP67, IK10.
Advanced Intelligent Functions : Face Detection, Heat Map
Include Wall Mount
• 1/2.8” 2Megapixel STARVIS™ CMOS
"Wide Dynamic Range
The camera achieves vivid images, even in the most intense contrast
lighting conditions, using industry-leading wide dynamic range (WDR)
technology. For applications with both bright and low lighting conditions
that change quickly, True WDR (120 dB) optimizes both the bright and
dark areas of a scene at the same time to provide usable video."

171
Effective Pixels : 1920(H) x 1080(V), 2 Megapixels
"Auto-tracking
This feature controls the pan/tilt/zoom actions of the camera to
automatically track an object in motion and to keep it in the scene. The
tracking action can be triggered manually or automatically by defined
rules. Once a rule is triggered, the camera can zoom in and track the
defined target automatically."
RAM/ROM : 1024M/128M
Scanning System : Progressive
Electronic Shutter Speed : 1/1s~1/30,000s
Minimum Illumination Color : 0.005Lux@F1.6; B/W: 0.0005Lux@F1.6
S/N Ratio More than 55dB
Focal Length : 4.8mm~120mm
Max. Aperture : F1.6 ~ F4.4
Angle of View : H: 62.8° ~ 2.6°
Smart H.265+ technology reduces bit rate and storage requirements by up
to 70% when compared to standard H.265 video compression.
"PFA technology has innovatively introduced new methods of judgment
to ensure the accuracy and predictability of the direction of subject
distance adjustment. The result is a set of advanced focusing algorithms.
PFA ensures clarity of the image throughout the process of zooming
and shortens focus time. The realization of PFA technology substantially
improves user experience and increases product value."
"Environmental
Cameras operate in extreme temperature environments, rated
for use in temperatures from -40 °C to +60 °C (-40 °F to +140°F) with
95% humidity. The camera complies with the IK10 Vandal Resistance
impact rating. Subjected to rigorous dust and water immersion tests
and certified to the IP67 Ingress Protection rating makes it suitable for

172
demanding outdoor applications."
"Protection
The camera allows for ±10% input voltage tolerance, suitable for the
unstable conditions for outdoor applications. Its 6KV lightning rating
provides effective protection for both the camera and its structure
against lightning.
Interoperability
The camera conforms to the ONVIF (Open Network Video Interface
Forum) specifications, ensuring interoperability between network video
products regardless of manufacturer."
"Resolution
1080P(1920×1080)/1.3M(1280×960)/720P(1280×
720)/D1(704×576/704×480)/CIF(352×288/352×240)"
"Frame Rate Main stream: 1080P/1.3M/720P(1~50/60fps).
Sub stream1: D1/CIF(1 ~ 25/30fps).
Sub stream2: 1080P/1.3M/720P/D1/CIF (1~25/30fps)"
"Bit Rate Control : CBR/VBR
Bit Rate : H.265/H.264: 448K ~ 8192Kbps
Day/Night : Auto(ICR) / Color / B/W
Backlight Compensation
BLC / HLC / WDR (120dB)
White Balance : Auto, ATW, Indoor, Outdoor, Manual
Gain Control : Auto / Manual
Noise Reduction : Ultra DNR (2D/3D)
Motion Detection : Support
Region of Interest : Support"
"Electronic Image Stabilization (EIS) : Support
Defog : Support
Digital Zoom : 16x

173
Flip : 180°
Privacy Masking : Up to 24 areas"
RJ-45 (10Base-T/100Base-TX)
ONVIF Profile S&G, API
Max. User Access : 20 users
"Edge Storage : NAS (Network Attached Storage),Local PC for
instant recording, Micro SD card 256GB."
"Web Viewer : IE, Chrome, Firefox, Safari
Management Software : Smart PSS, DSS, DMSS
Smart Phone : IOS, Android"
"Electrical
Power Supply : AC24V/1.5A(±10%), PoE+(802.3at)
Power Consumption : 13W,23W (Heater on)"
Manual Control Speed Pan: 0.1° ~350° /s; Tilt: 0.1° ~250° /s
Pan/Tilt Range Pan: 0° ~ 360° endless; Tilt: 0° ~ 90°,auto flip 180°
Presets 300
PTZ Mode : 5 Pattern, 8 Tour, Auto Pan ,Auto Scan
Ethernet R J - 45 (10Base-T/10 0Base-T X)
Interoperability : ONVIF Profile S&G, API
Power Supply : AC24V/1.5A(±10%), PoE+(802.3at)
Ingress Protection : IP67
Vandal Resistance IK10
"Certifications
CE: EN55032/EN55024/EN50130- 4
FCC: Par t15 subpar tB, ANSI C63.4- 2014
UL: UL60950-1+CAN/CSA C22.2,No.60950-1"

8 Channel Network Video Recorder 4K & H.265


"· Smart H.265+/H.265/Smart H.264+/H.264/MJPEG

174
· Max 320Mbps Incoming Bandwidth
· Up to 12MP Resolution for Preview and Playback
· HDMI/VGA simultaneous video output"
"NVR can be served as edge storage, central storage or backup storage
with an intuitive shortcut operation menu for remote management and
control and is compatible with ONVIF 2.4
protocol, enabling interoperability with 4K cameras."
Automatic Number Plate Recognition available for convenient entrance/
exit management. Support license plate recognition(working with ITC
camera), black/white list import/export, add/delete B/W list number,
search result from recorded video.
Main Processor : Quad-core embedded processor
Operating System : Embedded Linux
Access Channel : 8
Max 320Mbps Incoming Bandwidth
Recording resolution 12MP with 15fps, 8MP, 6MP, 5MP, 4MP, 3MP,
1080P, 1.3MP, 720P, D1, CIF with 30fps
HDMI/VGA simultaneous video output
Multi-screen Display : 8-channel: 1/4/8/9
"Video Detection and Alarm
Trigger Events : Recording, PTZ, Tour, Alarm Out, Video Push, Email,
Snapshot, Buzzer and Screen Tips
Video Detection : Motion Detection, MD Zones: 396 (22 × 18), VideoLoss
and Tampering.
Alarm input : 4 Channel.
Relay Output : 2 Channel."
"Max. User Access : 128 users
Smart Phone : iPhone, iPad, Android
Interoperability : ONVIF 2.4, SDK, CGI"

175
"USB : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 )
RS232 : 1 Port, for PC Communication and Keyboard
RS485 : 1 Port, for PTZ Control"
Recording Compression : Smart H.265+/H.265/Smart
H.264+/H.264/MJPEG
Network Function : HT TP, HT TPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP,
UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE,DDNS,
FTP, Alarm Ser ver, IP Search (Support IP
camera, DVR, NVS, etc.), Easy4IP
Interoperability : ONVIF 2.4, SDK, CGI
Record Mode : Manual, Schedule (Regular, MD(Motion Detection) ,
Alarm, IVS), Stop
Network Interface : 1 RJ- 45 Por t (10/100/1000Mbps)
Power Supply : 12V/4A
Power Consumption : < 9.5W (without HDD)
Smar t fan, automatically adjust running speed
Certifications : CE: EN55022, EN55024, EN50130- 4, EN60950-1
FCC : Par t 15 Subpar t B, ANSI C63.4-2014
UL : UL 60950-1

CCTV System Gedung LPSK


Penyedia wajib menyediakan CCTV untuk cctv sytem Gedung LPSK dengan
jenis, jumlah dan kelengkapan berikut :
CCTV Gedung LPSK
IP CCTV Dome Indoor 5MP IR Vari-focal 2 Unit
CCTV Ruang Sidang
IP CCTV Dome Indoor 5MP IR Vari-focal 4 Unit
Server Video Management System Surveillance 1 Unit

176
Produk Pendukung
LED Monitor 32 Inch + Braket 2 Unit
Hardisk For Storage CCTV Kantor Pusat 8TB 10 Unit
16-Port FE PoE+ 1-Port Gigabit Combo PoE Switch 2 Unit
16-Port FE PoE+ 1-Port Gigabit Combo PoE Switch ruang
4 Unit
sidang
Switch POE 8 port 4 Unit
UPS 10KVA/9KW 1Ph in -1Ph out 1 Unit
Switch Server 16 Port 1 Unit
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

Sistem CCTV Data Center dan Comand Center

Penyedia wajib menyediakan CCTV untuk CCTV sytem Data Center dan
Comand Center LPSK dengan jenis, jumlah dan kelengkapan berikut :

CCTV System Data Center dan Comand Center


IP CCTV Dome Indoor 5MP IR Vari-focal 8 unit
5MP Network Camera Indoor Commad Center Built-in
4 unit
MIC, Built-in Speaker
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

Sistem CCTV Rumah Aman

Penyedia wajib menyediakan CCTV untuk CCTV sytem Data Center dan
Comand Center LPSK dengan jenis, jumlah dan kelengkapan berikut :

177
CCTV system Rumah Aman
IP CCTV Dome Indoor 5MP IR Vari-focal 15 Unit
IP CCTV Bullet Outdoor 4MP IR 10 Unit
2MP 25x Starlight PTZ Network Camera 5 Unit
8 Channel Network Video Recorder 4K & H.265 5 Unit
Produk Pendukung 1 lot
Acces Point Wireless CCTV IP Camera 30 Unit
Hardisk For Storage CCTV Rumah Aman 6TB 5 Unit
16-Port FE PoE+ 1-Port Gigabit Combo PoE Switch 5 Unit
Modem Router wireless wifi 5 Unit
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

6.5.2 Spesifikasi Teknis Automations Sliding Gate

Design security sistem di pintu gerbang LPSK

Sistem gate yang ditawarkan harus memenuhi spesifikasi minimal sebagai


berikut :

178
 Automations Sliding Gates
Spesfisikasi
AUTOMATIONS SLIDING GATES INDUSTRIAL USE
up to 2500 kg
"Control unit with built-in receiver, magnetic encoder and inverter
oil lubricated reductions IP68 limit switch personalised release key"
"230 Vac
• Three phase 230 Vac geared motor, ventilated for intensive use
• Full metal mechanics and oil lubrication. The type of oil used ensures
maximum efficiency even at low temperatures
• The encoder device ensures precision in the gate moving phases
• Casing protective treatment and paint
• The inverter technology allows for more precise adjustment of the gate
moving phases, and increased crush prevention security
• Optional built-in FTC.S photocells, available as accessory"
"Foundation plate with anchor bolts included.
Motor and floor fixing distance 269 mm x 114 mm, no. 4 Ø 12 mm."
Weight 2,500 (kg) Speed 10 (m/min)
Weight 2,000 (kg) Speed 11 (m/min)
Weight 1,450 (kg) Speed 13 (m/min)
Weight 1,100 (kg) Speed 15 (m/min)
Weight 650 (kg) Speed 19 (m/min)
Power supply 230 Vac (50-60Hz)
Motor supply 230 Vac
Max absorbed current 8 A
Max Thrust 2500 N
Max opening speed 19 m/mi n
Duty cycle intensive use
Protection level IP44

179
Operating temperature -20°C /+50°C
Lubrication OIL
Max gate weight 2500 kg
Driving gear for rack M4 Z18
Weight 41.2 kg
Include :
"Galvanised slotted M4
rack 22x22x2010 mm
for fastening to the
side with the teeth.
Supplied with M6 screws."
Power supply : 14÷30 Vac - 12÷30 Vdc 50/60 Hz
"Capacity : 20-25 m
Working temperature : -20°C / +70°C"
Absorption* : TX: 20 mA (Vdc) - 40 mA (Vac), RX: 20 mA (Vdc) - 40 mA (Vac)
"Protection rating : IP44
Size : 110x35x35 (mm)"
Remotes
"• 2 or 4-channel transmitter of the series
with Advanced Rolling Code
• The new ARC coding guarantees maximum security
due to the length of the transmitted code (128 bit)
and the high number of possible combinations
• Equipped with 12 V battery for long lifespan
• Long range, up to 230 m in a free area
• Car accessory (TO.CLIP) or wall accessory (SMART) available"
flashing light
keyswitch
"hardwired keypad : Battery operated wireless

180
vandal-proof digital keypad with alert buzzer and backlit buttons.
Triple coding: Rolling Code, Programmable Code and Advanced
Rolling Code. 254 memorisable codes."

Gerbang sliding dan pintu pedestrian untuk pejalan kaki


Pekerjaan Besi, 1.000 - 1.100 kg
Ukuran : 7,2 m x 1,8 m = 13 M
Spesifikasi Bahan :
Besi galvanis 5x10 (Tebal : 2 mili) Bingkai frame
Besi galvanis 5x5 (Tebal : 2 mili) Isi bingkai frame
Besi plat esser (Tebal : 3 mili)
Besi kanal U (Rel)
Roda kanal U (Roda rel)

kuantitas pekerjaan Automations Sliding Gates mengacu pada tabel berikut:


Pekerjaan Automations Sliding Gates
Automations Sliding Gates 1 Unit
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

6.5.3 Spesifikasi Teknis Rising Bollard

Rising Bollard yang ditawarkan harus memenuhi spesifikasi minimal


sebagai berikut:

181
 Automatic Hydraulic Bollard 275/800 for Car 3 Bollard & Motorcycle 1
Bollard
Spesifikasi
Cylinder diameter 275mm
Cylinder height 800mm
With cylinder thickness 6 mm
"- Cataphoresis treatment and “Graphite Black” painting or cover
in brushed AISI316 stainless steel"

- Cylinder with built-in LED lights, the control unit can manage 2 bollards at
the same time
"- Foundation box complying with the EN124 (40T) regulation and
independent hydraulic pump for each bollard, laterally positioned in order
to avoid any damage in the event of an impact and facilitate the
maintenance"
"- In the event of a power failure, the bollard will remain in the raised
position (manual release)"
- Heating for the foundation box, buzzer and pressure switch for obstacle
detection available as accessories.
Impact resistance: 40.000 J
Breakout resistance: 250.000 J
ACCESSORIES:
Foundation box for 275 h 800 mm
CABLE FG16 16X1,5 X BOLLARDS for hydraulic bollard.
TRANSMITTER (ELECTRONIC COMMAND & CONTROL)
2-channel transmitter with Advanced Rolling Code.
• The new ARC coding guarantees maximum security
due to the length of the transmitted code (128 bit)
and the high number of possible combinations
• The model allows users to set up to 9 channels,
thanks to the option of activating the command by
simultaneously pressing two buttons chosen by the user.
This function allows avoiding accidental openings caused
by pressing a button by mistake and is particularly
indicated for use with alarm systems
• Equipped with 12 V battery for long lifespan
• Long range, up to 230 m in a free area
• Car accessory or wall accessory available
"- 433.92 MHz receiver with power supply 12÷28 VDC / 21÷28 VAC,
2 channels with triple coding: Advanced Rolling Code and Rolling Code, in
box. 512 memorisable codes."
LOOP DETECTOR

182
Single channel vehicle ground loop controller.
TECHNICAL DATA
Cylinder material : Steel S355JR
Raising time : 4 s
Lowering time : 4 s
Power supply : 230 Vac - 50/60 Hz (control panel with different voltages
available on request)
Power consumption 550W
Hydraulic pump : Built-in
Load index (EN124) : D400 (40 tonnes)
Manual lowering cycle in case of power failure : Manual release
Automatic lowering cycle in case of power failure : Optional
Obstacle detection during the rising cycle : Optional (GL.PRES)
Capacitor : 25 μF
Daily cycles : 3500
MCBF : 3.000.000
Operating temperature : -40°C ÷ +60°C [GL.HEAT available as option for
temperatures lower than -10°]

Protection level : IP67


Weight (without foundation box) : 105 kg
MAX.CP BL CONTROL PANEL X 2 BOLLARDS
Control panel for 2 hydraulic bollards
• 230 Vac 50/60 Hz power supply
• Control panel for 1 or 2 hydraulic bollards
• Integrated 433.92 MHz 64-code receiver with 3 encoding systems
(Advanced Rolling Code, Rolling Code, Fixed Code)
• Removable terminal boards
• Parameter and operation logic regulations through integrated LCD display
• Automatic, semi-automatic and deadman’s logic
• Programming access password
• Equipped with step-by-step command
inputs separate for each bollard and
centralised command inputs ALL UP
and ALL DOWN for the raising and the
lowering of both bollards
• Version with built-in board to manage
buzzer/LED lights available (MAX.CP BL)
• Separate limit switch inputs for each motor
• Control inputs for loop detectors and protection devices (GL.PRES)
• 2 outputs configurable as bollard status indicator or command of the
optional board CP.BL

• Designed for the connection of the optional board CP.BL to manage signal

183
lights and the warning buzzer GL.BUZZ
• Protection level IP54

Fix Bollards ( 5 unit )


Spesifikasi

Fix bollard
Height 80 cm;
Diameter 25 cm;

Material : Composite Fiberglass

Include : Rantai Baja 6 mm

Detail dan kuantitas pekerjaan Rising Bollards dan Fix Bollards mengacu pada
tabel berikut:
Pekerjaan Rising Bollards dan Fix Bollards
Rising Bollards ( 1 set = 3 bollards untuk Mobil) + 1
1 Set
bollards (Motor)
Fix Bollards 5 Unit
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

6.5.4 Spesifikasi Under Vehicle Inspection System


Under Vehicle Inspection System yang ditawarkan harus memenuhi
spesifikasi minimal sebagai berikut:

Spesifikasi

184
Under Vehicle Inspection System "Permanent System"
HIGH RESOLUTION
As the innovation leader Under Vehicle Inspection System provides high
resolution images of the undercarriage of scanned vehicles, which
guarantees best security standards.
"FULL VIEW IMAGES
With its innovative technology Under Vehicle Inspection System displays
the full undercarriage (incl. door sills / running boards) of scanned vehicles
in one high resolution picture, which allows continuous zooming in to
finest details."
"""CLEAR COLOR IMAGES
For state-of-the-art security standards
Under Vehicle Inspection System provides crystal clear color images, which
today is vital to secure safety at any kind of gate."""
"AUTOMATIC FOREIGN OBJECT DETECTION
Under Vehicle Inspection System provides automatic identification of
foreign objects or modification to a vehicle´s
undercarriage and highlights these changes to assist the guards for fast
inspection.”
"Under Vehicle Inspection System enables effective
safety inspections without slowing down the traffic flow at control points
and gates."
"RANGE OF APPLICATIONS
Under Vehicle Inspection System
Systems act as security line at gates of industrial facilities, military camps,
government buildings, border
crossings, airports, seeports, stadiums, hotels, car parks, prisons etc."
System creates highest resolution images
Imaging in color

185
Automatic Foreign Object Detection
Continuous Zoom-In-Technology for inspection of finest details
View of full undercarriage (incl. door sills / running boards)
Network capability, e.g. for data exchange of networked systems
Easy integration via interfaces for customer specific solutions
Deployed in almost 50 countries worldwide under all climate conditions"
"AUTOMATIC FOREIGN OBJECT DETECTION
The Under Vehicle Inspection System
system is equipped with an Automatic Foreign Object Detection Algorithm
which is supporting the detection of explosives, weapons, contrabands,
etc.
The current scan is compared with a former scan and any differences found
on the image will be highlighted to
the operator in red."
"Under Vehicle Inspection System AS PERMANENT SYSTEM
The Under Vehicle Inspection System as permanent system is available
with guiding axels or heavy duty cover. With the high quality stainless steel
heavy duty cover, the Under Vehicle Inspection System is ideal as
permanent installation.
The heavy duty housing offers the best possible protection for the
technology inside.
Used for sophisticated safety inspections in connection with a
comprehensive access control system Easy to install – mounts into the road
surface with little constructional effort."
"Under Vehicle Inspection System Automatic Number Plate
Recognition System (ANPR)
The Under Vehicle Inspection System Automatic Number Plate Recognition
(ANPR) decodes all kinds of vehicle plates with high
speed and precision. "

186
"Under Vehicle Inspection System Scene Camera
The integrated Under Vehicle Inspection System Scene Camera creates e.g.
a top-view-photo of the vehicle while driving through the inspection area.
With this solution the operator is able to check the roof of trucks and other
vehicles for contrabands and unauthorized persons, which are trying to
hide. "
"Under Vehicle Inspection System Driver Camera
Provides different kinds of solutions to take an image of the driver. "
Unique features:
▪ Imaging in color and monochrome
▪ Line scan technology: No image stitching
▪ View on full undercarriage (incl. door sills)
▪ System creates images with the highest resolution on the market
▪ Automatic-Detection-Feature
▪ Zoom-In-Technology
▪ Network capability, e.g. for data exchange between several combined
systems or for integration in
central control software
▪ Interfaces for customer specific solutions
▪ Developed and produced in Germany
Details:
The system consists out of following components:
▪ ScanStation with software, monitor, keyboard and mouse
▪ Scanner with permanent installation housing, guiding axles and cables
▪ Traffic light
Specifications ScanStation
Highlighting Features:
▪ Using line-scan-technology
▪ NO image stitching!!!

187
- tower housing
- Intel® Core™ i5
- 8GB RAM
- license base-package Software
- 24" wide screen LCD
- keyboard
- optical mouse
- power supply cable
- back plate with connections to scanner and traffic light
Specifications Scanner with permanent installation housing and guiding
axles
Highlighting Features:
▪ Installation in the road surface with little design effort
Scanner
- stainless steel housing
- LED illumination
- line scan camera
▪ resolution of average car: about 10Mpx
▪ max. resolution: up to 100Mpx
- panel heating
- incl. 30 meter data cable (up to 100 meter optionally available)
- incl. 30 meter power supply cable (up to 100 meter optionally available)
Permanent Installation Housing
- stainless steel housing
Specifications Traffic Light
- red / green LED Ø 200mm
- incl. sun visors and signal head arms
- 30 meter traffic light cable

188
Detail dan kuantitas pekerjaan Under Vehicle Inspection System mengacu
pada tabel berikut:
Pekerjaan Under Vehicle Inspection System
Under Vehicle Inspection System 1 Set
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

6.5.5 Spesifikasi X-ray Scanner


Perangkat X-ray scanner yang ditawarkan harus memenuhi spesifikasi minimal
sebagai berikut :
X-Ray Baggage Scanner Dual-view
Spectrum 7-color Imaging Technology
Generators Dual Images from 2 directions
Auxiliary : Explosives and Narcotics Detection Tools
More Than : 30 Versatile Image Processing Functions
Advanced : material classification (atomic number)
Unique : Neoteric Double Symmetrical Swing Door
4 and 7-COLOR IMAGING & ASSISTANT EXPLOSIVE AND NARCOTICS DETECTION
"number.
* Light organic materials (i.e. natural gas, gasoline)
* Organic materials (i.e. C-4, plastic explosives)
* Light inorganic materials (i.e. drugs and narcotics)
* Inorganic materials (i.e. glass, propellants)
* Light metals (i.e. gunpowder, IEDs)
* Heavy metals (i.e. firearms, bullets, knives)
* Dense metals (i.e. gold, silver, other high-value contraband)"
DUAL-VIEW X-RAY SCREENING TECHNOLOGY
The scanner provides two high quality dual-view images shot from different
angels(horizontal and vertical), in order to find the concealed dangerous

189
and illegal objects. The display model can be Dual-vertical and Dual-
horizontal.
"Combine with the Zeff-scan function to auto-highlighting the potential threat of
explosive and narcotic (liquid or solid) on x-ray image in real time during
scanning process according to the characteristics range of explosives and
narcotics atomic number, which help to
identify the suspicious more effectively. "
"VERSATILE SOFTWARE WITH 30 IMAGING PROCESSING TOOLS
• With over 30 imaging processing tools and detection alert algorithm
functions. Multiple access level account with different operation privileges
according to the status hierarchy.
• Backed by a team of rich experts, support customized function modules
according to clients requirements."
" HUMANIZED STRUCTURE WITH HIGH PROTECTION LEVEL
• Leaded rigid-steel structure and double layer leaded curtain to block x-ray
dose;
• Equipped with double symmetrical swing door at its both sides for convenient
repair and maintenance.
• Provided with system energized, X-Ray on indicators and emergency stop
buttons at both ends of X-Ray tunnel;
• 4 high-strength caster wheels at its base for ease of maneuverability, enable
operator to move the scanner easily;
• Offer adjustable wear-resistant foot cups to achieve stability and security
during use;
• The shift knob and key switch are securely located on top of the scanner, one-
key start and shutdown anytime."
software is to control the x-ray baggage scanner as well to acquire and process
the x-ray image with different tools to find the potential threat, all the tools can
be controlled by Exclusive Control Panel.

190
IMAGING PROCESSING TOOLS
"• Switchable 4 and 7 Colors Mode
• Inverse Mode
• Gray
• Variable Gamma
• Organics & Inorganic & Mixture Striping
• Plus 6 kinds Pseudo Color Display
• Variable High & Low Penetration
• Log & Exp Trans
• Gaussian Blur& Sharpen
• Super &Partial Enhancement
• High & Low & Fusion Energy
• Density Threshold Alarm(DTA)
• Continuous Zoom(64X)
• Splicing-scan(S-scan)
• Continuous Scan(C-scan)
• Zeff-scan(Z-scan)
• AI Roller(optional)
• Reset Image
• Calibration"
AUXILIARY FUNCTIONS
"• Bidirectional Scanning
• Recall Historical Image
• Query & Backup & Mark Image
• Print Image
• Baggage Counter
• Day/Time Display
• Multi-language Operation
• Auto Image Archiving

191
• Storage Type:PNG, JPEG, BMP
• Start-up Self-diagnostics
• Real-time Image Manipulation
• Different Access Level Account
• Network Ready
• Secure Access Key
• Emergence Stop Button
• 0.7 m Standard Extension Table
• Interlock(optional)
• Threat Image Projection(TIP)(optional)
• Operator Training System (OTS)(optional)"
GENERAL SPECIFICATION
"• Tunnel Size: 624(W)x 429(H)mm *24.5x24.7 in.+
• Belt Speed: 0.23m/s (45ft/min) Forward
• Conveyor Load: 165 kg(363 lb) Evenly Distributed
• Conveyor Height: 750mm(29.5 in.)
• Noise: <45DB"
X-RAY GENERATOR
• Voltage: 140kV*2
• Wire Detectability: 40 AWG
• Spatial Resolution: 1.0 mm Horizontal, 1.0 mm Vertical
• Steel Penetration: 36 mm steel Typical
• Tube Current: 0.7 mA
• Cooling: Sealed Oil Bath with Forced Air
• Duty Cycle: 100%,No Warm-Up Procedure Required
• Beam Direction: Upward and Sideward
• Detector: 1024 Channels in an L-Shaped Array
• Dual-energy: Yes
• Generate Angel: 80º

192
WORKING ENVIRONMENT
• Operating Temperature: 0°C- 40°C \ 32ºF - 104°F
• Storage Temperature: -20°C- 60°C \ -4ºF- 140ºF
• Humidity: Up to 95% Non-Condensing
• Power Requirements: 220VAC±10%, 50/60Hz, 10A Max
3440 x 1440; 24 bit/Pixel Color
2,00,000 images
COMPUTER
• Processor: Intel Pentium G4560
• Memory: 4 GB RAM
• Storage: 1TB SSD (standard)
• Platform: Windows®OS
• Display Type: 34”Curved-display
• Display Resolution: 3440 x 1440; 24 bit/Pixel Color
• Image Arching: 2,00,000 images
HEALTH AND SAFETY
• Compliant with National Radiation Safety Standards for
Cabinet X-Ray Systems.
• Typical Radiation leakage is less than 0.1 mR/hr(1.0 μSv/hr)
• Film Safety: Guarantee ISO 1600 (33 DIN)
Certificate and Standard
* US. FDA: Title [21, CFR, Part 1020.40]
* CE Compliance:
Directive 2014/30/EU Electromagnetic Compatibility
The Machinery Directive 2006/42/EC
LVD Directive 2014/35/EU
* RoHS: EN62321:2008
* FCC Compliance
* Film Safety: Up to ISO 1600( 33 DIN)

193
* Radiation Safety Certificate
* ISO9001 Quality Management System
• RADIATION SAFETY CERTIFCATE
Systems comply with all applicable
international health and safety regulations including
USA FDA X-ray systems (Federal Standard 2.1-CFR
1020.40), Ministry Security and Radiation Safety
Certificate by Human Settlement and Environment
Commission of Shenzhen Municipality. The x-ray
leakage is lower than the limit of 1.0μSv/hr(100μ
R/hr) at all panels and ports measured at the
distance of 5cm. The external radiation emission of
U.S. Federal Limit is 5μSv/hr.

Detail dan kuantitas pekerjaan X-ray Scanner mengacu pada tabel berikut:
Pekerjaan X-ray Scanner
X-ray Scanner 1 Unit
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

6.5.6 Spesifikasi Walk Through Metal Detector


Perangkat walk through metal detector yang ditawarkan harus memenuhi
spesifikasi minimal sebagai berikut :
Spesifikasi

Walk-through Metal Detector

194
Suitable for use both indoors and outdoors.
· 33 detection zones with corresponding indicators
· Built-in dual-direction traffic lights, Supports traffic lights that remind
pedestrians whether the pass is
allowed or prohibited.
Detection Capacity 60-100 person/min.
· 7-inch full color touch screen LCD display
Remote Control
An IR remote controller with maximum remote control range of 2 m
(6.56 ft)
Dual-mode Control
Adopts a 7-inch touch screen, which supports dual-mode control of
touch screen and remote control.
· Temperature monitoring display, Supports real-time body temperature
monitoring, visible and audible
alarm and real-time recording of abnormal body temperature.
· Counting passing number, pass/return numbers, and alarm number
255 adjustable sensitivity levels in each detection zone (sensitivity
increases by levels)
Safety Level, Supports 1-100 selectable security level.
Alarm Volume, Support 0-10 adjustable alarm volume, mute mode can
be set.
Leakage Current
< 0.5 mA, complying with safety requirements for electronic devices
Safety
Complies with the EMC Electromagnetic Radiation Standards by using
very low frequency electromagnetic fields. No harm caused to
pacemakers, pregnant women and magnetic storage devices.
Environmental

195
With a temperature range of –30 °C to +60 °C (–22 °F to +140 °F), the
camera is designed for extreme temperature environments. Subjected
and certified to rigorous dust and water immersion tests, the IP67 rating
makes it suitable for demanding outdoor applications.
· Easy-to-install modular design
· Monitor and display the real-time signal strength of environmental
interference
· Pass/Return statistics, alarm statistics, and searching by hour/day
· Display the alarm position via human shape display
· Ultra-high sensitivity, Minimum detect target: CNY ten-cent coin
· Independent detection of ferromagnetic and non-ferromagnetic metals
· Innocuous metal object filtering
· 90 applications selectable and it associates various detection features,
supports independent detection of magnetic metals, non-magnetic
metals and innocuous metal object filtering.
· Automatically searches operating frequency (100 levels available)
· Random alarm
· 2-level user management of operators and administrators
· Support multi-language, real-time switching
· 2-channel alarm output
· Monitoring and configuration through the network, and managed by
platform
Camera
· Uncooled VOx thermal sensor technology, Detector Type Vanadium
Oxide Uncooled FPA
· Athermalized lens (thermal camera), focus-free
· 4-MP 1/2.7'' progressive scan CMOS
· ROI, motion detection, color palettes

196
· Smoking and call behaviour detection
· Fire detection & alarm, With built-in fire detect function, the camera
has the ability to detect fire
in a long distance. Thermal camera is sensitive to temperature, so the
accuracy of fire detection will be higher than visible camera.
· Built-in 1/1 alarm in/out
· Micro SD memory, IP67, PoE
· Smart linkage with strobe light & audio
· Dual image fusion (visible and thermal images)
Camera Technical Specification Thermal Max. Resolution
256 × 192, Focal Length 3.5 mm, Close Focus
Distance 0.5 m (1.64 ft), Effective Distance Human (1.8 m × 0.5 m),
Digital Zoom 16 ×, Color Palettes 18
(Whitehot/Blackhot/Ironrow/Icefire/Fusion/Rainbow/Globow/
Iconbow1/Iconbow2, etc.)

Visible camera
Image Sensor 1/2.7'' CMOS, Max. Resolution
2336 × 1752, Pixel 4 MP, Min. Illumination : Color: 0.05 lux, Black &
white: 0.005 lux 0 lux (IR on), IR Illumination
Distance : ≥ 30 m (98.43 ft), Focal Length
4 mm, Close Focus Distance : 1.0 m (3.28 ft),
Video Compression
H.265/H.264M/H.264H/H.264B/MJEPG
Resolution Thermal:
Main Stream: 1280 × 960 (1.3M)/XVGA (1024 × 768)/
VGA (640 × 480)/256 × 192, 1280 × 960 by default
Sub Stream: VGA (640 × 480)/256 × 192, 256 × 192 by
default
Resolution Visual:

197
Main Stream: 2336 × 1752/1080p (1920 × 1080)/720p
(1280 × 720)/D1 (704 × 576), 2336 × 1752 by default
Sub Stream: 720p (1280 × 720)/D1 (704 × 576)/CIF (352
× 288), 352 × 288 by default
Frame Rate : Thermal
50Hz: (main stream) 1 fps–25 fps adjustable, 25 fps by
default; (sub stream) 1 fps–25 fps adjustable, 15 fps by
default
60Hz: (main stream) 1 fps–30 fps adjustable, 30 fps by
default; (sub stream) 1fps–30 fps adjustable, 15 fps by
default
Frame Rate : Visual
50Hz: (main stream) 1 fps–25 fps adjustable, 25 fps by
default; (sub stream) 1 fps–25 fps adjustable, 15 fps by
default
60Hz: (main stream) 1 fps–30 fps adjustable, 30 fps by
default; (sub strea
m) 1 fps–30 fps adjustable, 15 fps by
default
High Sensitivity
High thermal sensitivity (< 50 mK) makes cameras capture more image
details and temperature difference information.
Intelligent Video System (IVS)
With built-in intelligent video analytics, the camera has the ability to
detect and analyze moving objects for improved video surveillance. The
camera provides optional standard intelligence at the edge allowing
detection of multiple object behaviors such as motion detection. IVS also
supports tripwire analytics, allowing the camera to detect when a pre-
determined line has been crossed.

198
Smoking Detection
Thermal camera can provide a real-time monitoring, in the use of
AI technology, to automatically detect people's smoking behavior and
provide intelligent voice and light warning (loudspeaker and white light,
etc.) in an effort to dissuade smoker, and avoid potential risk and loss.
Certifications
Certifications : GB 15210-2018
IEC 60068-2-1
IEC 60068-2-2
CE-LVD: Low Voltage Directive 2014/35/EU
CE-EMC: Electromagnetic Compatibility Directive 2014/30/EU
CE-RED: Radio Equipment Directive 2014/53/EU
FCC: 47 CFR FCC Part 18, Subpart B
Safety :
ICNIRP 2010 Guidelines
ICNIRP 1998 Guidelines
EC directive 2013/35/EU
EC recommendation 1999/519/EC
IEEE C95.1:2005
Network Protocol HTTPS; HTTP; TCP; ARP; RTSP; RTP; UDP; RTCP; SMTP;
FTP; DHCP; DNS; DDNS; PPPOE; IPv4/v6; SNMP; QoS; UPnP; NTP
Interoperability ONVIF; CGI
Browser : IE: IE8 and the later, and explorer with IE core
Google: 42 and the earlier
Firefox: 42 and the earlier
Security : Authorized username and password; attached MAC address;
encrypted HTTPS; IEEE 802.1x; controlled network access

199
Detail dan kuantitas pekerjaan Walk Through Metal Detector mengacu pada
tabel berikut:
Pekerjaan Walk Through Metal Detector
Walk Through Metal Detector 1 Unit
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

6.5.7 Spesifikasi Access Control System


Access Control System

Access control system yang ditawarkan harus memenuhi spesifikasi


minimal sebagai berikut :
Features of Main Controller For Sliding Gate & Rissing Bollard
Support Single Door / 2 Doors
Support Car Park Mode
Support Dynamic Reader Location
Compatible with Various Reader Technologies
ActiveTransmit & ActiveDownload
Peer To Peer Global Anti-Passback
Configurable Digital / Supervised Inputs (8)
Event Based Triggering (EBT)
Unlimited Access Level
Onboard & Cross-Board Interlocking
User Counting (Card Holder / Car Park)
Advance Encryption Standard (AES)
Reader Output Control
Dynamic Storage Allocation
Dynamic Operation Profile
Support 30,000 Users And 80,000 Events Memory
Dimension 158mm (w) x 90mm (H)

200
MCU : 32bits @ 60MHz
Memory :
256K Flash Memory
32K SRAM (Buffer)
64Mbits Non-Volatile SPI Flash Memory (Storage)
Card holder : 30,000
Event Transaction : 80,000
Digital/Supervise Inputs : 8, User configurable
(Door Sensor/Request-To-Exit/Fire Input/General Purpose)
Digital Output : Max. 4 Dry contact Relay
Network Communication Port : RJ-45 Self-Negotiate 10/100mbps
Power Protection : Resettable Fuse - 2.5A
Surge Protection : TVS - Up to 15KVA
Onboard LED Control : Power / Communication / LAN / Event / Error
AC Fail Monitoring : Yes
Battery Monitoring : Yes (Firmware threshold control to shutdown control
panel)
External Short Circuit Protection : At readers
Backup Battery : Yes, Apply to RTC only

Features of Reader HID Mifare 13,5 Mhz


Typical Read Range : iCLASS: 1.6" (4 cm) MIFARE Classic: 1.2" (3 cm)
Mounting : Ideally suited for mullion-mounted door installations
or any flat surface
Color : Black
Keypad : No
Dimensions : 1.9" x 4.1" x 0.9" 4.8 cm x 10.3 cm x 2.3 cm
Operating Humidity : 5% to 95% relative humidity non-condensing

201
Environmental Rating : Indoor/Outdoor IP55; IP65 if installed with optional
gasket (IP65GSKT)
Transmit Frequency : 13.56 MHz & 125 kHz
Panel Connection Pigtail or Terminal Strip
Transmit Frequency 13.56 MHz & 125 kHz
13.56 MHz Card Compatibility Secure Identity Object™ (SIO®) on iCLASS
Seos, iCLASS SE/SR, MIFARE DESFire EV1 and MIFARE Classic (On by
Default) standard iCLASS Access Control Application (order with Standard
interpreter) ISO14443A (MIFARE) CSN, ISO14443B CSN, ISO15693 CSN
MIFARE Classic and MIFARE DESFire EV1 custom data models FeliCa™ CSN,
CEPAS CSN or CAN MIFARE DESFire EV2 via EV1 backward compatibility
125 kHz Card Compatibility HID Prox, AWID, Indala, EM4102
Communications Optional OSDP with SCP over RS485 Wiegand/Clock-and-
Data Interface 500ft (150m) (22AWG) - Use Shielded cable for best results
Certifications UL294/cUL (US), FCC Certification (US), IC (Canada), CE (EU),
C-tick (Australia, New Zealand), SRRC (China), MIC (Korea), NCC (Taiwan),
iDA (Singapore), RoHS
Cryto Processor Hardware Common Criteria Rating EAL5+
Patents US7180403, US7439862, US7124943, US5952935, US6058481,
US6337619
Housing Material UL94 Polycarbonate.
Features of Elevator Master Controll Panel
Support 8 floors by default (expendable to 136 Floors max.)
Support timezone control bypass for individual floor
Support up to 4 readers max.
Support both RFID & biometrics readers
Emergency bypass function by software
Emergency bypass function by key Switch
Support 30,000 Users And 80,000 Event Memory

202
MCU : 161 x 120 mm + 158 x 90 mm (HCB)
Memory :
32bits @ 60MHz
256K Flash Memory
32K SRAM (Buffer)
Operating Temperature : 64Mbits Non-Volatile SPI Flash Memory (Storage)
Card holder : 0 °C to 40 °C
Event Transaction : 30,000
Number Reader Supported : 80,000
Number of IO Supported : 8 (Complete with Expand Board)
Power Protection : RS232/RS485 User Configurable
Surge Protection : Resettable Fuse - 2.5A
Onboard LED Control : TVS - Up to 15KVA
Onboard Buzzer : Power / Communication / LAN / Event / Error
Battery Monitoring : Yes

Profesional Management Software And Card


Platform1 Software (Professional Edition)
On-line Transaction Event
Wizard Based Configuration
Door Interlocking
Global Anti-Passback (Peer to Peer)
Active Download
Unlimited Access Level Configuration
Customizable Card Format
Interactive Floor Plan
Event Based Triggering
Interactive Device Control
Alarm Monitoring

203
Roll Call Counting Screen
Location Tracking
Lift Access Control
Online Guard Tour
AES 128 BIT Encrition
Time Attendance Report
Various Reporting Module

Visitor Management System (1-Client)


Web based application
Host nottification upon visitor overstay did not checkout
Operator dashboard for real time visitor status
Simple to use intutive interface
whitelist and Blacklist
Comprehensive reporting engine
Integrated with Platform1 Access Control System
Encrypted database
Pre-Scheduling for visit
Host quick search
Automatic database backup to local or remote host
Searchable visitor history
Export report to various format (csv/pdf)
Selfexpiring visitor badges (RFID card)
HD camera Integration
MYkad reader Integration
Visitor category listing
Emergency evacuation report.

Mifare Card 13,56 MHz

204
ID Scanner
Active Scan Area 125mm x 88mm (4,92" x 3,46")
Illumination Sources LED visible white IR (8900), UVA (optional)
Image Resolution 500 PPI
Provider images Visible, IR, UV(UVA), OVD image, glare-free image
Image Formats BMP, JPG, JPG2000 and PNG
Image Color Depth 24 bits/pixels (RGB, 8bits/pixel (IR Image))
Automatic Document Detection (ADD) Yes
Reflection Removal (RR) Yes
ICAO MRZ Reading ICAO compliant documents per ICAO 9303 spesification
Part 1, Part 1v2, Part 2, Part 3 and Part 3v2 for type ID-2 and ID-3 MRZ
Optical Character Recognition
VIZ Reading Available based on user-devined fields
Barcode Reading 1D; UPC-A, EAN8, EAN13, Code39, Code128 and ITF 2D;
PDF 417, Data Matrix, QR Code, Aztec Code From paper-based documents
and mobile devices AAMVA compliant PDF417 and IATA BCBP
Contactless IC (RFID) Option Reading and writing contactless ICs according
to ISO 14443 Type A & R, ALL Standardized rates up to 848 Kbps
Magnetic Stripe Option Track 1, 2 and 3 stripes according to related ISO,
ANSI and AAMVA standards
Contact Smart Card Option ISO 7816 Class A, AB and C, ISO 7816 & EMV2
2000 Level 1

Smart Card Reader


Dual frequency – Simultaneously supports low and high frequency
credentials, including iCLASS Seos®, HID Prox®, iCLASS SE®, MIFARE
Classic®, MIFARE Plus®, MIFARE Ultralight® and MIFARE® DESFire® EV1,
EV2 as well as NFC

205
Supports mobile access – Available with Bluetooth interface to leverage
HID Global’s mobile credentials to access computer, network, data or cloud
Supports Seos® and iCLASS SE® Platform - Provides multi-layered security
that extends beyond the card technology, offering additional protection to
identity data.
Ease of use – Straightforward utilization of existing access control
credentials for PC login in both CCID and Keyboard Wedge operation
modes
Keyboard Wedge support – Retrieves data from a card and presents the
information directly to any application by emulating keyboard strokes.
HID Prox®, Indala® & EM Prox®, MIFARE® Classic, MIFARE DESFire® EV1,
EV2, iCLASS®, iCLASS SE®, iCLASS® Seos™, iCLASS® Elite, and other SIO
enabled credentials
Available with Bluetooth interface to be used with HID mobile access
credential for IT Access
Includes Apple’s Enhanced Contactless Polling (ECP) application to support
credentials in Apple Wallet
USB Interface USB 2.0 Full Speed Device (12 Mbps) USB 3.0 extended
operability, tested with hubs/controllers
Connector / Cable USB Type A connector; 59.1" (150 cm) cable
Supported APIs PC/SC - API, SAM - API
Status Indicator Dual Colour Led (White + Blue)
Housing Poly Carbonate Cover Black / Body Light Grey Card Holder for card
presence operation
Dimensions 2.79" x 3.66" x 0.63" (71 mm x 93 mm x 16 mm)
Weight ~100 g (3.53 oz)
Operating Temperature 32° - 131° F (0° - 55°C)
Operating Humidity 10-95% rH (not condensing)
Storage Temperature -4° - 176° F (-20° - 80°C)

206
Meantime Between Failure (MTBF) 500.000 hours
Compliance / Certification USB 2.0
Regional certifications CE, FCC, UL, KCC, RCM
Environmental WEEE, RoHS3, Reach

WebCam
HD video calling (1280 x 720 pixels) with recommended system
HD video capture: up to 1280 x 720 pixels
Fluid Crystal™ Technology
More HD technology
Autofocus
Photos: up to 8 megapixels (software enhanced)
Built-in microphone with Logitech RightSound™ technology
Hi-Speed USB 2.0 certified (recommended)
Universal clip fits laptops, LCD or CRT monitor
Logitech RightLight™ 2 technology
Video and photo capture
MAGIX™ photo and video editing software
1-click Facebook™, Twitter™ and YouTube™ HD upload (registration
required)
Video Effects™: fun filters, avatars, face accessories, video masks and mask
maker*

Main Controller For Server room and Control Room


Support 8 floors by default (expendable to 136 Floors max.)
Support timezone control bypass for individual floor
Support up to 4 readers max.
Support both RFID & biometrics readers
Emergency bypass function by software

207
Emergency bypass function by key Switch
Support 30,000 Users And 80,000 Event Memory
MCU : 161 x 120 mm + 158 x 90 mm (HCB)
Memory :
32bits @ 60MHz
256K Flash Memory
32K SRAM (Buffer)
Operating Temperature : 64Mbits Non-Volatile SPI Flash Memory (Storage)
Card holder : 0 °C to 40 °C
Event Transaction : 30,000
Number Reader Supported : 80,000
Number of IO Supported : 8 (Complete with Expand Board)
Power Protection : RS232/RS485 User Configurable
Surge Protection : Resettable Fuse - 2.5A
Onboard LED Control : TVS - Up to 15KVA
Onboard Buzzer : Power / Communication / LAN / Event / Error
Battery Monitoring : Yes

Fingerprint IP Access Terminal


Biometric : Fingerprint
Template : ISO 19794-2/ANSI 378
Extractor / Matcher : MINEX certified and compliant
LFD : Supported
RF Option : 125 KHz EM & 13.56 MHz Mifare, DESFire EV1/EV2*, FeliCa,
NFC
CPU : 1.2 GHz Quad-Core
Memory : 2GB Flash + 256 MB RAM

208
Max. User : 500,000 (1:1), 100,000(1:N)
Max. Template : 1,000,000(1:1), 200,000(1:N)
Max. Logs : 1,000,000(text)
LCD : 2-inch color LCD
Sound : 16-bit Hi-Fi
Certificates : CE, FCC, KC, RoHS, REACH, WEEE

High Performance Authentication Scanner


Sensor Type : Optical
Resolution : 500 ppi
Gray Scale : 256 level
Platen Size (W x L mm) : 16 x 18
Sensing Area (W x H mm) : 14.6 x 16.2
Image Size (W x H pixels) : 288 x 320
Ingress Protection : IP65 (Sensor Surface)
S/W : Windows, Linux
Image Format : RAW, BMP, WSQ, ISO 19794-4
Certification : CE, FCC, KC, WHQL
Contactless Button Exit
"Size : 115 * 70 * 25mm
Input : 12VDC
Contact Rating : 3A@12~28VDC
Output : NO/NC/COM
Weight : 150g"

Emergency Break Glass Door Release


The EB4 emergency door release is designed with replaceable glass for ease
of breaking through.
Electric Bolt Action LOCK wit Fail Safe

209
"Operating Voltage: 12VDC
Operating Current: 900mA
Holding Current: 350mA
Lock Type: Fail-safe type
Operation Delay Time: 0sec, 2.5sec, 5sec, 9sec
Door Sensor: N.C
Built-in Delayed Egress, Control Point
Dimension:
Face Plate: 200mm x 32mm x 40mm
Strike Plate: 90mm x 26mm x 2mm
Bolt Stainless Steel: 15.5 Diameter, 16mm throw"
Braket U For Drop Bolt
"To be used with elock-B100 Bolt Action Lock.
Suitable for glass (thickness of 9mm -12mm).
Stainless steel built for durability.
Rubber plate and steel plate for strong holding.
Dimensions of large glass holder: 90X27X40 (mm).
Weight: 300g."

PC Server dan Receptionis (Setara)


Processor: Intel Core i7-G11
RAM: 16GB DDR4
SSD: 1TB
ODD: DVDRW
VGA: AMD Radeon R7 430 2GB
Konektivitas: NIC, WiFi 5
Sistem Operasi: WIndows 10 Pro
Monitor minimal 17 inch

210
Perangkat Pendukung:
 Switch PoE+ 16 Port
 Switch PoE+ 8 Port
 Manual Push Button
 Rain Proof Housing

Detail dan kuantitas pekerjaan Access Control System mengacu pada tabel
berikut:
Pekerjaan Access Control System
Main Controller 2 Unit
Reader HID Mifare 13,5 Mhz 4 Unit
Entrypass Elevator Master Control Panel 2 Unit
Reader HID Mifare 13,5 Mhz 2 Unit
Coneverter Serial To IP 2 Unit
Platform1 Software (Professional Edition) 1 Unit
Visitor Management System (1-Client) 1 Unit
Mifare Card 13,56 MHz 1500 Pcs
ID Scanner 1 Unit
Smart Card Reader 1 Unit
WebCam 1 Unit
Produk Pendukung, PC Server, Monitor, Switch, manual
1 lot
push Button, Rain Proof Housing
Material Instalasi ( Kabel, Pipa, dll ) 1 lot
Instalasi, Setting, Testing Commissioning, Training 1 lot

Access Control Data Center


Perangkat Access Control yang disediakan di pasang dengan ketentuan
berikut :

211
 Seluruh pintu diruangan Data Center harus dipasang Acces Control dengan
finger print dan support untuk proximity card
 System Controler pada acces control harus terintegrasi dengan system Fire
Alarm yang ada, sehingga jika Fire Alarm aktif maka semua pintu harus
terbuka untuk memudahkan proses evakuasi

detail dan kuantitas pekerjaan access control dapat mengacu pada tabel
berikut :

No Deskripsi QTY
Pekerjaan Acces Control
Main Controler 3 Unit
Fingerprint IP Access Terminal 5 Unit
High Performance Authentication Scanner 1 Unit
Produk Pendukung : Contactless Button Exit,
Emergency Break Glass Door Release, Electric Bolt
1 Lot
Action LOCK wit Fail Safe, Braket U For Drop Bolt. (Cek
BQ).
Material Instalasi ( Kabel, Pipa, dll ) 1 Lot
Instalasi, Setting, Testing Commissioning, Training 1 Lot
6.5.8 Spesifikasi Teknis Perangkat pendukung komunikasi
Perangkat pendukung komunikasi yang ditawarkan harus memenuhi spesifikasi
minimal sebagai berikut :
NO DESCRIPTION QTY

1 HT DIGITAL 10 Unit
Frekuensi : UHF (403-527 MHz)
VHF 136-174 MHz
350 (350-400 MHz)
Channel spacing : 12.5/25 kHz

212
Power Supply : - 7.5V
Channel Capacity 256
TRANSMITTER SPECIFICATIONS
Digital Modulation : 12.5 kHz Data: 7K60F1D and
7K60FXD, 12.5 kHz Voice: 7K60F1E and 7K60FXE,
Combination of 12.5 kHz Voice and Data: 7K60F1W
Digital Protocol ETSI TS 102 361-1, -2, -3
RECEIVER SPECIFICATIONS
Analogue Sensitivity (12dB SINAD) 0.16 uV
Digital Sensitivity (5% BER) 0.14 uV
Intermodulation (TIA603D) 70 dB
AUDIO SPECIFICATIONS
Digital Vocoder Type AMBE+2™
Audio Response TIA603D
Rated Audio 0.5 W

2 Telepon Satelit 2 Unit


Dudukan hotspot: 142 x 69 x 38mm / 290g
coating steel finish.
Adaptor smartphone universal : 138 x 69 x 42mm / 256g
(Adaptor universal dapat menampung smartphone dengan
lebar antara 58 - 85mm).
Konektivitas : jack headset 3.5mm, Micro USB, jack pengisian
DC,
Jangkauan WiFi : 30m (Hotspot)
Baterai: 3.7V Li-ion, 2440 mAh
Waktu bicara: hingga 3 jam
WiFi terus menyala : hingga 9 jam
WiFi mati : hingga 70 jam
Kecepatan Data : Unduh hingga 60 kbps, Unggah hingga 15
kbps (GmPRS)
Daya: Output DC 5V / 2.0A

213
Suhu pengoperasian : -10°C hingga + 55°C
Suhu penyimpanan : -20°C hingga + 70°C

Simcard Inmarsat isatphone pro 2 Unit

6.7 Spesifikasi teknis renovasi Pos Keamanan


a) Pembongkaran ruangan existing
Kegiatan pembongkaran ruangan existing harus memperhatikan aspek
keamanan, kebersihan dan kenyamanan pengguna di sekitar area ruangan
existing dan harus di koordinasikan dengan pihak pengelola gedung.

b) Pemasangan dinding / partisi


Spesifikasi Teknis:
 Rangka : Rangka vertikal Metal Stud tebal 0,4mm.
Rangka horizontal atas dan bawah U Runner tebal 0,4mm.
 Penutup partisi: Digunakan Gypsum Board yang bermutu baik tebal = 9 mm.
 Bahan penutup sambungan partisi: Compound, paper tape yang
berpori/berlubang dan bergaris tengah.

c) Pemasangan Plafon / Ceiling


Spesifikasi Teknis:
Rangka:
 Rangka dari besi hollow galvanis 4 x 4 cm/ 2 x 4 cm, tebal pelat besi hollow
minimal 0,35 mm.
Penutup langit-langit:
 Gypsum Board yang bermutu baik produk Jayaboard/knauf atau produk lain
yang setara, tebal = 9mm.
Bahan penutup sambungan plafond:
 Compound atau bahan plester ex UB400 atau produk lain yg setara. Dan
paper tape yang berpori/berlubang dan bergaris tengah.

Volume pekerjaan renovasi Pos Keamanan

No Description Qty Unit

214
A PEKERJAAN PRA POJECT
PEKERJAAN PERSIAPAN
1 Mobilisasi Alat dan Bahan Ls
1.00
2 Survey, Ploting dan Marking Area Ls
1.00
3 Kebersihan dan Keamanan Kerja Ls
1.00
4 Proteksi dan Alat Bantu Kerja Ls
1.00
5 Desain dan Shopdrawing Ls
1.00

B PEKERJAAN BONGKARAN
1 Pek. Bongkaran Plafond Existing Ls
1.00
2 Pek. Bongkaran Instalasi Listrik Ls
1.00
3 Pek. Bongkar dan Pasang Pintu Existing Ls
1.00
4 Pek. Pembersihan/buang puing Ls
1.00
5 Pek. Perapihan bongkaran Ls
1.00
6 Pekerjaan Perapihan Talang air Ls
1.00

C PEKERJAAN SIPIL
Pekerjaan Pasangan Dinding
Pekerjaan Penambalan Dinding Atas Toilet uk. 2000 x
1 Ls
310 1.00
Spek:
- Bata Merah dan Semen
2 Pek. Pengecetan dinding toilet m2
4.94
Spek:
- Vinilex/setara
3 Pekerjaan Penambalan Dinding Atas Kaca t. 31cm Ls
1.00
Spek:
- Clear Glass 5mm
- Frame Alumunium

PEKERJAAN PLAFON
1 Pek. Plafond Gypsum Flat m2
24.00

215
Spek:
- GRC Board 9mm
- Rangka Hollow Galvanis 4x4, 4x2, 0.4 mm
2 Pek. Pengecatan Plafond Gypsum m2
24.00
Spek:
- Cat Interior ex. Vynilex atau setara

D PEKERJAAN MEP
1 Pekerjaan Inst. Lampu Penerangan 6.00 ttk
- NYM 3x2.5 mm, Ex. Supreme/Setara
2 Pekerjaan Pengadaan Lampu Downlight ttk
6.00
Spek:
- Lampu 16 Watt Ex. Phillips/Setara
3 Pekerjaan Perapihan Instalasi lot
1.00
3 Pekerjaan Pemasangan AC Split 1/2 Pk + Instalasinya lot
1.00

216
6.8 Spesifikasi teknis Mobile Witness Room
Mobile witness room yang ditawarkan harus memenuhi spesifikasi berikut :
 Design

 Spesifikasi

Jumlah/
No. Uraian Spesifikasi satuan

I Chassis Heavy truck 6 Roda Minimal standar : 1 unit


- Kapasitas mesin 4000cc
- Tenaga 136 Ps
- Euro 4
- Jarak Sumbu Roda 3.350mm-3.360mm
II 1 Karoseri 1 unit
a Eksterior
Konstruksi
Panel body assy full plat galvanil 1,0 mm
Bumper depan original
Bumper belakang modifikasi custom
Lantai plat 2.0 mm
Body samping kiri terdapat :
- Pintu depan ass.driver model swing
- Pintu akses masuk ruang cabin belakang

217
- Kompartemen Tools bawah
- Kompartemen Tools belakang
- Kompartemen maintenance genset
Body samping kanan terdapat :
- Pintu depan driver model swing
- Pintu emergency di dalam toilet
- Kompartemen Tools bawah
- Kompartemen Tools belakang
Body belakang :
Pintu belakang model kupu-kupu untuk ruang genset
Lampu - lampu :
Lampu depan model standard chassis
Lampu belakang standar karoseri
Lampu ketinggian depan dan belakang
Roof atas model High roof
Cat standar karoseri
Anti karat standard karoseri
Logo atau cutting sticker sesuai pesanan
Kaca-kaca :
kaca depan original chassis
kaca pintu driver & assisten original chassis
Kaca pintu belakang tempered glass
Kaca samping tempered glass
b Partisi
Ruang kabin depan dengan ruang cabin belakang full plate
dilapis polywood finishing duco dan dengan ruang Genset
penyekat menggunakan bahan full plate finishing cover bahan
peredam
c Interior
a. Cabin depan
Kursi Driver original chassis + safety belt
Kursi ass. driver original chassis + safety belt
Side trim dan door trim ruang sopir original chassis
b. Cabin Belakang
Flapon Ceiling model ducting dengan konsep luxury bahan
acrylic dan HPL
Lantai bahan vinyl motif kayu (disesuaikan interior)
Dinding /trimboard bahan deco sheet kombinsai vinyl
C. Kursi,Sofa dan Lemari
Kursi captain seat bahan kulit Mbtech/setara 2 buah
Sofa letter "L" bahan kain sofa 1 set
lemari dan kitche set kayu MDF lapis tacon 1 unit
Lantai ruang Genset menggunakan bahan allumunium bordes

218
2.3 mm
Lampu - lampu penerangan :
- Lampu penerangan (AC/DC) model tanam
2 Kelengkapan
a Pendingin ruang listrik AC model roof top 1 unit
b Pemadam api kapasitas 2 kg 2 unit
c Ac unit triple blower 1 unit
d Genset 5 Kva Type Silent 1 unit
g Gorden 1 unit
h Kaca film 40%,80% 1 unit
i Smart TV 40" 2 pc
j Kulkas mini 1 pc
k Toilet 1 Unit
l Console depan 1 pc
m Storage dan standing bracket untuk TV 40" 1 pc

Ketentuan lainnya;
 Peraturan dan ketentuan yang harus di ikuti dalam pembuatan Mobile witness room;
o Peraturan Menteri Perhubungan Republik Indonesia Nomor PM 60 Tahun 2019 Tentang
Penyelenggaraan Angkutan Barang Dengan Kendaraan Bermotor Di Jalan
o Peraturan Menteri Perhubungan Republik Indonesia Nomor PM 33 Tahun 2018 Tentang
Pengujian Tipe Kendaraan Bermotor
o Peraturan Menteri Perhubungan Republik Indonesia Nomor PM 54 Tahun 2019 Tentang Tata
Cara Uji Sampel Kendaraan Bermotor

 Surat Keputusan Rancang Bangun (SKRB) yang dikeluarkan oleh Kementerian Perhubungan dan di
lampirkan oleh pelaksana

 Harga kendaraan Mobile Witness Room merupakan OTR (on the road)

 Pelaksana pekerjaan bertanggung jawab terhadap pengurusan nomor polisi kendaraan

 Mobile witness room mempunyai garansi selama 12 bulan untuk seluruh item yang terinstall dan
terpasang didalam kendaraan

 APAR yang tersedia juga dilengkapi dengan sertifikasi

 Tersedianya perangkat keselamatan yang cukup dan sesuai peraturan dan perundangan yang berlaku bagi
pengendara dan penumpang

 Tersedia panel kelistrikan yang memadai untuk pengaturan kelistrikan internal dan eksternal dari Mobile
witness room

 Tangki air bersih dan kotor mempunyai garansi anti kebocoran selama 4 tahun

219
6.9 Spesifikasi Teknis sistem Manajemen Kasus Saksi dan Korban
6.9.1 Spesifikasi Umum Sistem

1. Sistem informasi harus dibangun dengan prinsip scalable dan


interoperabilitas untuk mengantisipasi pertumbuhan dari pengguna
maupun pengembangan fungsionalitas sistem;
2. Sistem informasi harus dibangun dengan prinsip Standard Development
Methodology yang sudah teruji;
3. Sistem informasi harus dibangun dengan prinsip accessible yaitu
kemudahan untuk diakses;
4. Sistem informasi harus dibangun dengan prinsip mendukung proses
pengambilan keputusan;
5. Sistem informasi harus dibangun dengan teknologi berbasis microservices
6. Sistem informasi harus dibangun dengan prinsip Uniform User Interface
untuk mendukung kemudahan penggunaan sistem bagi User;
7. Sistem informasi ini harus fleksibel sehingga memungkinkan dilakukan
perubahan dan penambahan fungsi untuk mengadaptasi perkembangan
kebutuhan LPSK di kemudian hari;
8. Sistem informasi ini harus memiliki high performance untuk menangani
bertambahnya jumlah transaksi dan response;
9. Sistem informasi ini harus reliable, dengan menggunakan komponen,
desain dan teknologi yang sudah terbukti banyak digunakan untuk solusi
enterprise;
10. Sistem informasi ini harus bersifat terbuka agar bisa berkomunikasi dengan
sub-sistem lain dengan menggunakan interface yang umum digunakan;
11. Sistem informasi ini mempunyai kemampuan menangani
hardware/software fail-over dalam waktu yang singkat.
12. Sistem informasi dikembangkan dengan berbasis web, mobile android dan
ios sehingga dapat diakses dari manapun dan kapanpun.
13. Sistem informasi dikembangkan menggunakan komponen teknologi dan
desain arsitektur untuk Enterprise solution;

220
14. Sistem informasi dikembangkan menggunakan arsitektur aplikasi adalah 3
tier atau N-tier di mana database, application server dan presentation tier
dipisahkan secara logik, sehingga memudahkan pengelolaan data dan
aplikasi;
15. Sistem informasi diinstal pada infrastruktur perangkat keras milik LPSK dan
dapat dijamin tidak dapat diakses dari luar oleh pihak yang tidak diberikan
akses;
16. Sistem informasi dapat berjalan pada sistem operasi server multi platform
Windows Server/Linux/Unix.
17. Sistem informasi menggunakan standar industri SSL;
18. Dokumentasi analisa kebutuhan, dokumentasi perancangan sistem, source
code, dokumentasi pemeliharaan dan dokumentasi user manual
diserahkan kepada pihak LPSK seluruhnya dan menjadi hak cipta LPSK;
19. Garansi / pemeliharaan sistem informasi selama 12 bulan setelah Go-Live;
20. Sistem informasi dikembangkan dengan menggunakan metode secure
coding;
21. Sistem informasi yang dibuat wajib dilakukan pengujian kelaikan paling
kurang meliputi:
- Uji Fungsi
- Uji Integrasi
- Uji Beban/Stress Test
- Uji Keamanan
22. Sebelum dilaksanakan user acceptance test (UAT), sistem informasi yang
dibuat wajib lulus uji penetrasi dari pihak ketiga yang ditunjuk oleh LPSK.

6.9.2 Spesifikasi Fungsional Sistem

1. Manajemen User

a. Mengelola user publik yang mengakses sistem (register, login, forgot password)
b. Pengamanan menggunakan OTP (Email dan Whatsapp/Telegram)
c. Mengelola user internal yang mengakses sistem (login, forgot password)
d. Dapat terintegrasi dengan sistem manajemen identitas dan single sign-on

221
e. Role user (viewer, editor dan admin)
f. Audit log semua activity user

2. Pengajuan Permohonan

a. Modul dapat diakses dari aplikasi web ataupun mobile


b. Mengelola semua jenis permohonan (Perlindungan Fisik, Perlindungan Prosedural,
Perlindungan Hukum, Fasilitasi Restitusi dan Kompensasi, dsb)
c. Mengelola permohonan baik yang disampaikan melalui aplikasi ataupun offline
d. Integrasi dengan data e-KTP / Dukcapil untuk proses validasi data
e. Setiap data permohonan tersimpan dan dikelola berdasarkan status
f. Upload data, dokumen dan gambar dengan format tertentu
g. Memberikan alert / notifikasi kepada pemohon apabila ada perubahan status

3. Pemeriksaan Permohonan

a. Modul dapat diakses dari dashboard aplikasi web oleh petugas


b. Memberikan informasi notifikasi kepada petugas
c. Mengelola dan menelaah semua jenis permohonan yang masuk seperti (Perlindungan Fisik,
Perlindungan Prosedural, Perlindungan Hukum, Fasilitasi Restitusi dan Kompensasi, dsb)
d. Menyediakan jenjang status / flow pemeriksaan yang dinamis
e. Mencatat hasil pemeriksaan data permohonan

4. Permintaan Dokumen Persyaratan (sesuai dengan jenis laporan)

a. Mengelola jenis dokumen persyaratan (sesuai dengan jenis laporan) secara dinamis
b. Memberikan informasi kepada pemohon untuk upload dokumen persyaratan yang
dibutuhkan
c. Fitur upload dokumen persyaratan
d. Memberikan alert / notifikasi kepada petugas apabila dokumen persyaratan sudah
diupload ke dalam sistem
e. Memberikan catatan / revisi perbaikan dokumen persyaratan

5. Wawancara

222
a. Menugaskan pelaksana wawancara
b. Melakukan penjadwalan wawancara dengan pemohon
c. Mendokumentasikan hasil wawancara dalam bentuk audio/ video/ catatan
d. Link dengan data permohonan yang diajukan
e. Dokumen tersimpan dan dapat dicari dengan mudah

6. Assessment Psikologis Medis

a. Menentukan pelaksana assessment


b. Melakukan penjadwalan assessment dengan pemohon
c. Mendokumentasikan hasil assessment dalam bentuk audio/ video/ catatan
d. Link dengan data pemohon
e. Dokumen tersimpan dan dapat dicari dengan mudah

7. Penelaahan Lapangan

a. Menentukan pelaksana penelaahan lapangan


b. Melakukan penjadwalan penelaahan lapangan dengan pemohon
c. Mendokumentasikan hasil penelaahan dalam bentuk audio/ video/ catatan
d. Link dengan data pemohon
e. Dokumen tersimpan dan dapat dicari dengan mudah

8. Laporan Risalah Permohonan Perlindungan

a. Upload laporan risalah permohonan perlindungan catatan


b. Link dengan data permohonan
c. Dokumen tersimpan dan dapat dicari dengan mudah

9. Rapat Paripurna Pimpinan

a. Mencatat jadwal paripurna pembahasan permohonan


b. Mendokumentasikan hasil rapat paripurna pimpinan dalam bentuk audio/ video/ catatan
c. Link dengan data permohonan
d. Dokumen tersimpan dan dapat dicari dengan mudah
e. Proses Voting, Penutupan Voting, Hasil Putusan Rapat
f. Menentukan case manager

223
10. Penyusunan Perjanjian

a. Mendokumentasikan draft perjanjian dalam bentuk dokumen dan versioning


b. Mendokumentasikan baseline perjanjian dalam bentuk dokumen dan versioning
c. Link dengan data permohonan
d. Dokumen tersimpan dan dapat dicari dengan mudah

11. Penandatanganan Perjanjian

a. Memberikan alert / notifikasi kepada pemohon terkait jadwal penandatanganan perjanjian


b. Mendokumentasikan perjanjian dalam bentuk dokumen yang telah ditandatangani
c. Dokumen tersimpan dan dapat dicari dengan mudah

12. Monitor Pengelolaan Kasus (subjek perlindungan)

a. Notifikasi / alert jadwal kegiatan yang ditentukan (pemeriksaan medis, dll)


b. Update Informasi terkait kasus
c. Survey Penilaian Kinerja (periodik & di akhir kasus)
d. Live Chat
e. Panic Button - Kondisi Panik

13. Administrasi Pengelolaan Kasus (case manager)

a. Mengelola bantuan medis (rumah sakit) dari penjadwalan hingga pencatatan hasil
pemeriksaan medis
b. Mengelola rehabilitasi psikologis dari penjadwalan hingga pencatatan hasil pemeriksaan
medis
c. Mengelola rehabilitasi psikososial dari penjadwalan hingga pencatatan hasil pemeriksaan
medis
d. Mengelola permohonan kompensasi dari pengajuan hingga persetujuan/tidak
e. Mengelola permohonan restitusi dari pengajuan subjek hingga Kejaksaan
f. Melakukan update informasi terkait kasus
g. Live Chat dengan terlindung
h. Memonitor lokasi / positioning subjek secara real time

14. Dashboard dan Laporan

224
a. Dashboard / Laporan Monitoring Lokasi Subjek
b. Dashboard / Laporan statistik permohonan perlindungan
c. Dashboard / Laporan statistik kasus perlindungan
d. Dashboard / Laporan progres penanganan kasus
e. Dashboard / Laporan kinerja case manager
f. Dashboard / Laporan SLA penanganan permohonan
g. Dashboard / Laporan hasil survey
h. Dashboard / Laporan penanganan bantuan medis kesehatan, rehabilitasi, dll
i. Dashboard / Laporan pengecekan kondisi fisik dan psikologis saksi dan korban terlindung
j. Dashboard / laporan penanganan tindakan atas alert PANIK
k. Dashboard / Laporan lainnya yang dibutuhkan oleh manajemen

6.10 Spesifikasi Teknis alat pengolah Data


a) Notebook Type 1 sebanyak 25 unit
 Display : 13.3” retina display
 Processor : minimal Apple M1 Chip (CPU 8-Core, GPU 7-Core)
 RAM : 8 GB
 Storage : 512 GB SSD
 OS : Mac OS
 Bundling MS Office Standar 2021 LTSC

b) Notebook Type 2 sebanyak 150 unit


 Display : 14” FHD
 Processor : Intel Core i7 – Gen11
 RAM : 16 GB
 Storage : 512 GB SSD
 Graphic : 2 GB GDDR6 dedicated
 OS : Windows 10 Professional Edition
 Bundling MS Office Standar 2021 LTSC

c) Notebook Type 3 sebanyak 5 unit


 Display : 14” FHD
 Processor : Intel® Core™ i7-1165G7 (up to 4.7 GHz with Intel®
Turbo Boost Technology, 12 MB L3 cache, 4 cores)

225
 RAM : 32 GB DDR4-3200 MHz RAM
 Storage : 1 TB SSD
 Graphic : Intel® Iris® Xᵉ Graphics NVIDIA® T500
(4 GB GDDR6 dedicated)
 OS : Windows 10 Professional Edition
 Bundling MS Office Standar 2021 LTSC

6.11 Spesifikasi Teknis Managed Service


Menyediakan 2 orang Engineer On Site 8 jam x 5 hari selama 1 tahun dengan
kualifikasi :
1) 1 orang Network Engineer yang memiliki sertifikasi minimal level associate
di bidang jaringan
2) 1 orang DCV Engineer yang memiliki sertifikasi minimal level associate di
bidang server atau storage atau virtualisasi
3) Menyediakan alat pendukung pekerjaan seperti pc/laptop, printer dan
lainnya
4) Melakukan corrective maintenance terhadap perangkat jaringan,
keamanan jaringan, server dan storage dengan detail pekerjaan berikut :
a) Melakukan monitoring terhadap performance perangkat jaringan,
keamanan jaringan, server dan storage
b) Melakukan backup konfigurasi perangkat jaringan dan keamanan
jaringan secara berkala
c) Melakukan troubleshooting dan rekonfigurasi perangkat jaringan dan
keamanan jaringan jika terjadi problem pada perangkat terkait
d) Melakukan troubleshooting dan resetting perangkat server dan storage
jika terjadi problem pada perangkat terkait
e) Melakukan eskalasi ke principal jika dibutuhkan
f) Memberikan rekomendasi untuk peningkatan performa jaringan jika
dibutuhkan
g) Memberikan laporan bulanan yang memuat informasi performa
perangkat jaringan, keamanan jaringan, server dan storage serta
coorective maintenance yang telah dilakukan

6.12 Spesifikasi Teknis Videotron Office Hall

Perangkat videotron yang ditawarkan harus memenuhi spesifikasi berikut:

a. Spesifikasi sistem Videotron:

226
Screen Size 4 x 2m Cabinet Size
: 500x500x65mm
(Layar Utama)
Screen Size 3 x 2m Cabinet Size
: 500x500x65mm
(Layar Kanan)
Screen Size 3 x 2m Cabinet Size
: 500x500x65mm
(Layar Kiri)
Pixel Pitch : 2,5mm
Minimal Brightness : 900 nit
Contrast Ratio : 1:5000
Processing Dept : 14bit
Viewing Angle : 160x160
Module Resolution : 84x168
Refresh Rate : 2880 hz
Frame rate : 50/60
Lifetime : 100.000 Hours
Controller : 1 unit
IP Rating : 30
Interface : HDMI, DP, USB and OPS
Input Resolution : 4k
3 in 1 SMD
HDR 10 Feature
Signal Redundancy Feature

b. Spesifikasi Struktur Rangka


 Rangka : Besi Holow 40x40mm tebal 1,8mm
Finishing Spraypaint ex. Danaglos/Danapaint/setara
 Base Plate; 3mm
 Dinabolt & aksesoris
c. Spesifikasi Backrop
 Panel Backdrop : bahan Multiplkes Fin. HPL ex. TACO,
 Base Panel Videowall, dengan Bahan Plywood tebal 18mm, Finishing Cat
d. Spesifikasi ruang operator videotron
 Kaca cermin dua arah uk 10 mm
 Frame Alumunium Ex YKK/Setara

227
Volume pekerjaan videotron Office Hall

No Description Unit Qty

A PEKERJAAN PERSIAPAN
1 Mobilisasi dan Demobilisasi Alat dan Bahan Material ls
1,00
2 Kebersihan dan Kemanan Area Kerja ls
1,00
3 Proteksi dan alat bantu kerja ls
1,00
4 Ploting dan Pengukuran Area Kerja ls
1,00
5 Shopdrawing dan Desain ls
1,00

B STRUKTUR & BACKDROP


Struktur dan Backdrop Videotron Layar Utama
1 Pekerjaan Struktur Rangka LED Videotron Un
1,00
Spek:
- Besi Holow 40x40mm thk.18mm, Fin. Spraypaint ex. Danaglos/Danapaint/setara
- 3mm thk. Base Plate
- Dinabolt & aksesoris
2 Backdrop Videotron Uk. 3720 x 6000 Un
17,65
Spek:
- Multiplkes Fin. HPL ex. TACO
- Nat Stainless 3 Cm
3 List Stainless Uk. 5 Cm ls
1,00
Struktur dan Backdrop Videotron Layar Kanan
1 Pekerjaan Struktur Rangka LED Videotron Un
1,00
Spek:
- Besi Holow 40x40mm thk.18mm, Fin. Spraypaint ex. Danaglos/Danapaint/setara
- 3mm thk. Base Plate
- Dinabolt & aksesoris
2 Backdrop Videotron Uk. 3720 x 6000 Un
17,65
Spek:
- Multiplkes Fin. HPL ex. TACO
- Nat Stainless 3 Cm
3 List Stainless Uk. 5 Cm ls
1,00

228
Struktur dan Backdrop Videotron Layar Kiri
1 Pekerjaan Struktur Rangka LED Videotron Un
1,00
Spek:
- Besi Holow 40x40mm thk.18mm, Fin. Spraypaint ex. Danaglos/Danapaint/setara
- 3mm thk. Base Plate
- Dinabolt & aksesoris
2 Backdrop Videotron Uk. 3720 x 6000 Un
17,65
Spek:
- Multiplkes Fin. HPL ex. TACO
- Nat Stainless 3 Cm
3 List Stainless Uk. 5 Cm ls
1,00

C PEKERJAAN PLAFON
1 Pembongkaran & Perapihan Plafon akibat Bongkaran ls
1,00
2 Pengecetan Plafon ls
1,00

D PEKERJAAN DINDING dan FURNISHING


1 Pekerjaan Pembuatan Wallpanel Uk. 3720 x 800 Unit
2,00
Spek :
- Plywood 18,15,12,9mm Fin. HPL ex. TACO
2 Pekerjaan Pembuatan Pintu Kamuflase Unit
1,00
Spek :
- Plywood 18 Fin HPL ex TACO
3 Pekerjaan Pemasangan Wallpaper m2
6,00
4 Pekerjaan Meja Operator Uk. 1200 x 800 bh
1,00
5 Pekerjaan Pengadaan Kursi : Senator II GAR Synch T35 SCB bh
1,00

E Pekerjaan VideotronAuditorium Lt.6


1 LED Wall Display with Pixel Pitch P2.5 ( Layar Utama ) 8 m2
Indoor LED with cabinet Size 500x500x65mm
Brightness 1000nits, max Power 540w/sqm, with Lifetime 100.000 Hours

2 LED Wall Display with Pixel Pitch P2.5 ( Layar kanan ) 6 m2

Indoor LED with cabinet Size 500x500x65mm


Brightness 1000nits, max Power 540w/sqm, with Lifetime 100.000 Hours

3 LED Wall Display with Pixel Pitch P2.5 ( Layar Kiri ) 6 m2

229
Indoor LED with cabinet Size 500x500x65mm
Brightness 1000nits, max Power 540w/sqm, with Lifetime 100.000 Hours

4 CVCA LED Controller 1 pcs

5 10M HDMI cable - copper 3 pcs


6 Pemasangan, seting, programing & Test Commisioning 1 set
7 Personal Computer 1 set
- Prosessor intel i7
- DDR3 : 8GB
- Hardisk SSD 1TB

7. Daftar Kuantitas
Daftar kuantitas untuk kegiatan Pembangunan Sarana Pusat Data dan Revitalisasi
Infrastruktur Teknologi Informasi dan Komunikasi LPSK adalah :

NO JENIS BARANG / JASA QTY


I Data Center Tier 3
A Data Center Infrastructure
1 Pekerjaan Sipil & Interior Data Center 1 lot
2 Pekerjaan sistem kelistrikan 1 lot
3 Pengadaan Sistem UPS modular 1 lot
4 Pengadaan Genset & Rumah Genset 1 lot
Pengadaan Sistem Pencegah Kebakaran ( fire supression
5 1 lot
system )
6 Pengadaan Sistem Pendingin ( precisscion Air Cooling ) 1 lot
7 Pengadaan Infrastruktur pendukung Data Center 1 lot

B Data Center Network Infrastructure


 1  Core Switch 2 unit
2 Server Farm Firewall 2 unit
 3  Internet Firewall 2 unit
4 TOR Switch 2 Unit
5 Management Switch 1 unit
6 SDWAN Router kantor pusat 1 unit
7 Email Security 1 unit
8 Load Balancer&WAF 1 unit

230
9 Bandwidth management 1 unit
10 Network & Application performance monitoring 1 Paket
11 Server Vitualisasi 4 unit
13 SAN Switch 2 unit
14 SAN Storage 1 unit
15 Sistem Operasi 1 Paket
16 Software Manajemen Virtualisasi 1 unit

II Campus Network , Perwakilan&Rumah Aman


A Campus Network
1 Access Switch Non Poe 6 unit
2 Access Switch Poe 6 unit
3 Access Point 30 unit
4 Wireless Controller 2 unit
5 Cabling system 1 Lot
B Perwakilan & Rumah Aman
1 SDWAN Router 3 unit
2 Access Switch 3 unit
3 SDWAN Router rumah aman 5 unit
C Pengadaan Managed Service
1 EOS 8 x 5 durasi 1 tahun 1 Paket

III Comand Center


Pekerjaan Sipil & Infrastruktur pendukung Comand
1 1 lot
Center

IV Pengadaan Renovasi Ruang Sidang Mahkamah Pimpinan & Ruang Sidang kasus

1 Renovasi Ruang Sidang mahkamah pimpinan 1 lot

V Pengadaan Renovasi pos security


1 Pekerjaan renovasi pos security 1 lot

VI Pengadaan Infratsruktur Sistem Security gedung LPSK


1 CCTV System LPSK 1 lot
2 Pengadaan automatic sliding gate 1 Set
3 Pengadaan Rising Bolard for car & motor cycle 1 Set
4 Pengadaan Under Vehicle Inspection System 1 lot

231
5 Pengadaan Xray Scanner 1 Unit
6 Pengadaan Walkthrough Metal detector 1 Unit

7 Pengadaan Access Control System Gedung LPSK 1 lot

Pengadaan perangkat pendukung komunikasi ( 2 unit


8 1 lot
Telepon Satelit & 10 unit HT )

VII Pengadaan Mobile Witness Room


1 Pengadaan Mobile Witness Room 1 Paket
Chasis 1 unit
Karoseri 1 Paket
2 Pengadaan SDWAN router 1 Unit

VIII Pengembangan aplikasi mobile sistem manajemen kasus saksi dan korban

Mobile App mobile sistem manajemen kasus saksi dan


1 1 Paket
korban
2 lisensi pendukung software
Mobile Software
Playstore Account Developer 1 Years
Applestore Account Developer 1 Years
Maps SDK Android (100000 calls) 36 Month
Maps SDK IOS (100000 calls) 36 Month
Google Find Place (25000 calls) 36 Month
Dashboard Report License
Creator license 1
Viewer license 10

IX Capacity Building
1 Capacity building /pelatihan untuk staff LPSK 1 Paket

X Alat Pengolah Data


1 notebook type 1 25 unit
2 notebook type 2 150 unit
3 Laptop Workstation 5 unit

XI Videotron Office Hall


1 Videotron Office Hall 1 Lot

232
8. Kualifikasi Tenaga Ahli
Penyedia wajib menyediakan tenaga ahli dengan kualifikasi berikut:
Pengala
No Jabatan Jml Sertifikasi/Kualifikasi Pendidikan man
minimal
Tenaga Ahli Infrastruktur
I
Project Management
1 Project Manager 1 Minimal S2 Teknologi Informasi 5 tahun
Professional
S1 Ilmu
Sertifikasi level expert
Tenaga Ahli Komputer/Informatika/Sistem
2 1 untuk enterprise 5 tahun
jaringan Senior informasi/Teknik
internetwork /setara
komputer/Teknik Elektro
Sertifikasi level S1 Ilmu
Tenaga Ahli profesional untuk Komputer/Informatika/Sistem
3 4 5 tahun
jaringan junior enterprise internetwork / informasi/Teknik
setara komputer/Teknik Elektro
S1 Ilmu
Tenaga ahli Sertifikasi level expert
Komputer/Informatika/Sistem
4 Keamanan 1 untuk network security / 5 tahun
informasi/Teknik
jaringan setara
komputer/Teknik Elektro
1 orang Sertifikasi level
associate untuk S1 Ilmu
Tenaga Ahli networking. dan 1 orang Komputer/Informatika/Sistem
5 2 5 tahun
Managed Services sertifikasi level associate informasi/Teknik
untuk server / komputer/Teknik Elektro
storage/virtualization
Sertifikasi level
S1 Ilmu
Tenaga ahli professional untuk
Komputer/Informatika/Sistem
6 server, storage 1 sistem operasi / 5 tahun
informasi/Teknik
dan virtualisasi virtualisasi sesuai dengan
komputer/Teknik Elektro
produk yang di tawarkan
S1 Ilmu
Sertifikasi level
Tenaga ahli Data Komputer/Informatika/Sistem
7 1 professional untuk data 5 tahun
Center informasi/Teknik
center
komputer/Teknik Elektro
Tenaga Ahli
8 1 SKA Arsitek S1 Teknil Sipil/Arsitektur 5 tahun
Arsitektur
S1 Teknik Mesin/ D3 Teknik
9 Tenaga Ahli HVAC 1 Sertifikat terkait HVAC 5 tahun
Mesin/SMK TPTU
Tenaga Ahli Sertifikat SKA Teknik
10 1 S1 Teknik Sipil 5 tahun
Bangunan Bagunan Gedung
- Sertifikat SKA Teknik
Tenaga Ahli Tenaga Listrik dan teknik
11 2 S1 Teknik Listrik 5 tahun
Electrical Elektronika & Komunikasi
dalam Gedung

233
- Sertifikat Tenaga Ahli
UPS
-Surat Izin Bekerja
sebagai Petugas Proteksi
Tenaga Ahli Radiasi dari BAPETEN Sistem informasi
12 Petugas Proteksi 1 -Sertifikat Training Teknologi/Elektro/Telekomunik 2 tahun
Radiasi Petugas Proteksi Radiasi asi
Industri Tk. 3 dari
BAPETEN
Tenaga Ahli
Sertifikat K3 dari
Kesehatan dan
12 1 Lembaga yang Minimal D3 3 tahun
Keselamatan
berwenang
Kerja
II Tenaga Ahli Aplikasi
1. Co-Project 1 a) Memahami konsep S1 Ilmu 5 tahun
Manager integrasi data, Komputer/Informatika/Sistem
bahasa informasi/Teknik
pemrograman, basis komputer/Teknik Elektro
data.
b) Memahami instalasi
aplikasi di lingkungan
Linux ataupun
Windows.
c) Memahami konsep
pembangunan Single
Sign On (SSO) dan
LDAP.
d) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.
2. System Analyst 2 a) Memiliki keahlian di Minimal S2 Teknologi Informasi 5 tahun
bidang analisa dan
design aplikasi
b) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.
3. Database 1 a) Memiliki keahlian di S1 Ilmu 5 tahun
Administrator bidang pengelolaan Komputer/Informatika/Sistem
database skala informasi/Teknik
enterprise komputer/Teknik Elektro
b) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.

234
c) Sertifikat Database

4. Development 1 a) Memiliki keahlian di S1 Ilmu 5 tahun


Operations bidang pemrograman Komputer/Informatika/Sistem
skala enterprise informasi/Teknik
b) Memiliki sertifikasi komputer/Teknik Elektro
pemrograman Java
c) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.
5. Web Developer 6 Memiliki keahlian di S1 Ilmu 5 tahun
bidang pemrograman Komputer/Informatika/Sistem
aplikasi web informasi/Teknik
komputer/Teknik Elektro
6. Android dan IOS 4 Memiliki keahlian di S1 Ilmu 3 tahun
Mobile Developer bidang pemrograman Komputer/Informatika/Sistem
aplikasi mobile Andoid / informasi/Teknik
IOS komputer/Teknik Elektro

7. API Developer 2 a) Memiliki keahlian S1 Ilmu 3 tahun


pemrograman Komputer/Informatika/Sistem
berbasis API / informasi/Teknik
microservices komputer/Teknik Elektro
b) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.
8. Software Tester 2 a) Memiliki keahlian di S1 Ilmu 3 tahun
bidang pengujian Komputer/Informatika/Sistem
software sehingga informasi/Teknik
memperoleh standar komputer/Teknik Elektro
kualitas yang sesuai
b) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.
9. ETL Developer 1 a) Memiliki keahlian S1 Ilmu 3 tahun
pemrograman ETL Komputer/Informatika/Sistem
b) Berpengalaman informasi/Teknik
dalam proyek terkait komputer/Teknik Elektro
pengembangan
aplikasi IT di
pemerintah dan

235
Swasta.

10 DevOps Engineer 1 a) Memiliki keahlian di S1 Ilmu 2 tahun


bidang DevOps Komputer/Informatika/Sistem
b) Memiliki pengalaman informasi/Teknik
mengembangkan komputer/Teknik Elektro
aplikasi berbasis
microservices/contai
ner Kubernetes atau
setara
11. Technical Writer 1 c) Memiliki keahlian di S1 Ilmu 3 tahun
bidang penulisan Komputer/Informatika/Sistem
dokumentasi secara informasi/Teknik
tersistem komputer/Teknik Elektro
d) Berpengalaman
dalam proyek terkait
pengembangan
aplikasi IT di
pemerintah dan
Swasta.
III Tenaga Pendukung

1 Drafter 1 Memiliki pengalaman SMK Teknik Gambar Bangunan 1 tahun


sebagai drafter
2 Administrasi 1 Memiliki pengalaman D3 1 tahun
Proyek sebagai proyek
administrator

9. Pelaporan
Penyedia barang dan jasa wajib membuat laporan pelaksaan kegiatan sesuai dengan
rangkaian kegiatan, meliputi :
a. Laporan Pendahuluan
Merupakan laporan yang memberikan gambaran proses tahapan kerja yang akan
dilaksanakan. Laporan ini akan berisikan antara lain:
- Rencana kerja pelaksanaan secara menyeluruh
- Design dan gambar kerja yang terkait dengan bagian pekerjaan yang akan
dikerjakan
- Contoh material bangunan, mekanikal, elektrikal dan arsitektur wajib di setujui
oleh pihak pemberi kerja sebelum dilakukan pembelian, dengan mengajukan
papan contoh material dan surat persetujuan.

236
- Rencana Mobilisasi perangkat, material dukung, tenaga ahli dan tenaga
pendukung lainnya
- Jadwal kegiatan pelaksanaan kerja
b. Laporan kemajuan pekerjaan
Merupakan laporan yang memberikan informasi mengenai kemajuan pelaksanaan
pekerjaan yang dilaporkan per 2 minggu, progress pekerjaan akan dibahas dalam
rapat dwimingguan
c. Laporan Akhir
Merupakan laporan yang memberikan informasi mengenai seluruh kegiatan yang
telah dilaksanakan.
10. Lokasi kegiatan
Lokasi kegiatan Pengadaan pembangunan Pusat Data dan Revitalisasi Infrastruktur
Teknologi Informasi dan Komunikasi LPSK dilakukan di Gedung LPSK Jl. Raya Bogor
No.KM. 24 No. 47-49, Kel. Susukan, Kec. Ciracas, Kota Jakarta Timur, Daerah Khusus
Ibukota Jakarta.
11. Jangka Waktu pelaksanaan Kegiatan
Pelaksanaan pekerjaan dilaksanakan selama 120 hari kalender (4 bulan) sejak surat
perintah mulai kerja (SPK) di terbitkan.
Penyedia wajib menyampaikan jadwal pelaksanaan pekerjaan yang terperinci untuk
setiap bagian pekerjaan yang akan dilaksanakan.

237

Anda mungkin juga menyukai