Self Assesment
Test No.7
An exhaust fan in a constant
area well insulated duct delivers
air at an exit velocity of 1.5 m/s
at a pressure differential of 6 cm
H2O. Thermometers show the
inlet and exit temperature of the
air to be 21.1°C and
22.8°C,respectively. The duct
area is 0.60 m2. Determine the
actual power requirement for
the fan.
Solution
 1. Mengkoversi nilai ΔP dari cmH O menjadi atm
2

ΔP= 6 cmH2O = = 0.0058 atm


2. Mencari nilai P2
P2 = P1 + ΔP = 1 + 0.0058 atm = 1.0058atm
3. Mencari nilai v1 menggunakan persamaan kontinuitas,dimana = 1.2 Kg/m3

1.2 Kg/m3 . 0.60 m2 . V1 = 1.2 Kg/m3 . 0.60 m2 . 1.5 m/s


V1 = 1.5 m/s
Dikarenakan V1=V2, maka dapat diasumsikan bahwa system merupakan steady
state.dimana

= 1.2 Kg/m3 x 0.60 m2 x 1.5 m/s


= 1.08 Kg/s
Solution
 4. Analisa Hukum Thermodinamika 1

……(1)
Asumsi yang digunakan:
5. ΔEK = 0 , dikarenakan v1=v2 sehingga diasumsikan tidak terjadi perubahan
energy kinetic.
6. ΔEP = 0 , dikarenakan ketinggian inlet sama dengan ketinggian outlet.
7. Q = 0 , dikarenakan tidak ada panas yang diberikan kedalam system maupun
panas yang dilepaskan dari system akibat system di insulasi dengan baik.
Maka persamaan 1 menjadi,
……(2)
……(3)
……(4)
Solution
  Dimana, = 37.241 grmol/s

5.Menghitung nilai ΔH, dimana nilai Heat Capacities dari udara didapatkan dari
appendix E1.
Solution
 

6. Mensubstitusikan nilai ΔH ke persamaan 3


……(3)
1838.087 J/s = Ws
1838.087 Watt = Ws
Jadi, dapat disimpulkann bahwa kebutuhan daya actual yang diperlukan oleh system
sebesar 1838.087 J/s atau 1838.087 Watt.