Anda di halaman 1dari 23

PT.

ARLISCOPUTRA
HANTAMA
SETTING
F6 RECLOSER CONTROLLER
METODE PENGOPERASIAN
Form 6
MANUAL
KOMPUTER
MENU SETTING
REVIEW DAN MERUBAH SETTING SEMUA
FUNGSI DARI SEMUA PROFILE PROTEKSI
DARI CONTROL F6
MASUK KE MENU SETTING (VIEW ONLY)
•TEKAN TOMBOL MENU
•TEPATKAN CURSOR (>) PADA SETTING
•TEKAN ENTER
•PILIH MOD/VIEW SETTING DENGAN CURSOR
(>)
•TEKAN ENTER
•TEKAN F1 UNTUK HANYA MELIHAT
SETTING
•PILIH APLIKASI YG AKAN DI LIHAT
•TEKAN ENTER
MASUK KE MENU SETTING (MODIFY)
•TEKAN TOMBOL MENU
•TEPATKAN CURSOR (>) PADA SETTING
•TEKAN ENTER
•PILIH MOD/VIEW SETTING DENGA CURSOR
(>)
•TEKAN ENTER
UNTUK MASUK KE MENU SETTING JUGA
BISA
MELALUI SHORTCUT/JALAN PINTAS
DENGAN
MENEKAN TOMBOL SETTINGS PADA
ANALYSIS
KEY
SETTING OVERCURRENT
PADA PROTEKSI OVERCURRENT INI AKAN DI
TAMPILKAN PADA DISPLAY LCD LIST DARI
SETING PHASE, GROUND DAN NEGATIVE
SQUENCE. KURVA PROTEKSI JUGA BISA
DIPILIH UNTUK TCC1 DAN TCC2.
PARAMETER SETTING YG AKAN DI
TAMPILKAN:
•BESARAN MINIMUM TRIP OC.
•MENU KURVA TCC1 & TCC2, TERMASUK
SUBMENU KURVA:
•SETTING MULTIPLIER.
•SETTING ADDER.
•SETTING MINIMUM RESPON.
•SETTING HIGH CURRENT TRIP.

SEMUA BESARAN SETTING BISA


DIRUBAH MELALUI FRONT CONTROL
PANEL F6. DENGAN MENGIKUTI
GAMBAR DI SEBELAH KIRI INI TAHAP
DEMI TAHAP AKAN MEMANDU PROSES
SETTING
SETTING MINIMUM TRIP UNTUK PHASE,
GROUND, DAN NEGATIVE SQUENCE
MINIMUM TRIP MERUPAKAN BESARAN
ARUS MINIMAL UNTUK MEMBUAT PROTEKSI
BEKERJA SESUAI DENGAN TIMING KURVA
ARUSNYA.

PERHATIKAN HURUP DI BELAKANG TCC”P”


ITU MENUNJUKAN SETING AKAN DI
PERUNTUKAN UNTUK PHASE, “G” UNTUK
GROUND DAN “Q” UNTUK NEGATIVE
SEQUENCE.

BESARAN SETING ARUS YANG DI


TAMPILKAN DI DISPLAY LCD ADALAH ARUS
PRIMER.

BESARAN SETTING YANG DI PERBOLEHKAN


AKAN DI TUNJUKAN PADA DISPLAY
(MINIMUM DAN MAKSIMUM).

TAMPILAN GAMBAR INI ADALAH CONTOH


SETTING UNTUK “P” PHASE.
METODE PEMBACAAN
F6 RECLOSER CONTROLLER
METERING
MENU METERING
MENU METERING PADA DISPLAY LCD INI
ADALAH UNTUK PEMBACAAN
PENGUKURAN. DI MENU INI TIDAK ADA
MODIFIKASI YG BISA DILAKUKAN MANUAL.

PEMBACAAN METERING YG DITAMPILKAN:

•PENGUKURAN LANGSUNG ARUS DAN


TEGANGAN UNTUK PHASE DAN GROUND.
•ARUS PUNCAK.
•POWER PUNCAK.
•PENGUKURAN POWER LANSUNG.
•BESARAN ENERGY.
•POWER FACTOR.
•FREQUENCY.

PERHATIKAN GAMBAR BAGAI MANA


MENGGUNAKAN MENU METERING DARI
FRONT PANEL CONTROL F6. JUGA BISA DI
LIHAT SHORTCUT UNTUK MENGGUNAKAN
MENU INI.
PEMBACAAN METERING INSTAN
(LANSGUNG)
ILUSTRASI INI MENAMPILKAN CONTOH
PEMBACAAN PENGUKURAN LANGSUNG

ARUS DAN TEGANGAN PRIMER

POWER FAKTOR

FREQUENCY
SQUENCE OF EVEN
SQUENCE OF EVEN, PEMBACAAN
REKAMAN KEJADIAN – KEJADIAN.
PADA PENGGUNAAN MENU REKAM
KEJADIAN (EVEN) INI F6 MAMPU
MENAMPILKAN 25 REKAMAN KEJADIAN
TERAKHIR PADA DISPLAY LCD-NYA.

EVEN YG DI TAMPILKAN:
•PENJELASAN KEJADIAN
•TANGGAL KEJADIAN DENGAN FORMAT :
TAHUN-BULAN-TANGGAL.
•WAKTU/JAM DARI KEJADIAN.
•PHASE ARUS GANGGUAN A, B DAN C.
•ARUS PENTANAHAN / GROUND.
•TEGANGAN SECONDARY PHASE A, B DAN C.

ILUSTRASI PENGGUNAAN MENU EVEN BAIK


LEWAT URUTAN MENU MAUPUN LEWAT
SHORTCUT.
ALARM
ALARM LOG AND STATUS MENU,
REKAMAN ALARM LOG DAN STATUS
MENU
MENU INI MENAMPILKAN ALARM YG AKTIF
SAAT ITU YG TERDETEKSI OLEH KONTROL
F6.

ALARM YG AKTIF STATUSNYA DI


TAMPILKAN DENGAN ANGKA “1” DAN
ANGKA “0” UNTUK ALARM YG TIDAK AKTIF
(NO ALARM).

ILUSTRASI PENGGUNAAN MENU ALARM


BAIK LEWAT URUTAN MENU MAUPUN
LEWAT SHORTCUT.
RESETTING ALARM, CARA MERESET
ALARM YG AKTIF
ALARM YG DI TAMPILKAN DI LCD DISPLAY
BISA DI RESET MELALUI FRONT PANEL.

ALARM YG AKTIF STATUSNYA DI


TAMPILKAN DENGAN ANGKA “1” DAN
ANGKA “0” UNTUK ALARM YG TIDAK AKTIF
(NO ALARM).

ILUSTRASI PENGGUNAAN MENU UNTUK ME-


RESET ALARM.

KETIKA ALARM DI RESET AKAN MUNCUL


KONFIRMASI “ALARMS ARE RESET”.
KONFIRMASI INI HANYA MUNCUL SESAAT
+/-2DETIK.

ALARM HANYA DI RESET BILA HANYA


KONDISI PENYEBAB ALARM SUDAH TIDAK
ADA ATAU SUDAH DI PERBAIKI.
COUNTER
MENU COUNTER
CONTROL F6 MEMILIKI COUNTER UNTUK
MENGHITUNG OPERASI DARI RECLOSER.
CONTER INI BISA DI RESET MELALUI FRONT
PANEL BILA DI INGINKAN.

COUNTER:
•TRIP OPERATIONS COUNTER
•TRIP TARGET A-PHASE, B-PHASE, C-PHASE,
GROUND DAM SEF FAULT.

ILUSTRASI PENGGUNAAN MENU COUNTER


BAIK LEWAT URUTAN MENU MAUPUN
LEWAT SHORTCUT.
RESETTING COUNTERS, CARA MERESET
HITUNGAN COUNTER

ILUSTRASI PENGGUNAAN MENU UNTUK ME-


RESET HITUNGAN COUNTER.
ProViewTM Software
SYSTEM REQUIREMENTS:
PC DENGAN INTEL PENTIUM II ATAU LEBIH.
PROCESSOR 350 MHz ATAU LEBIH.
RAM 256 MB ATAU LEBIH.
OS : WINDOWS95, WINDOWSNT, ATAU WINDOWS YG
TERBARU.
CD ROM (FOR INSTALLATION)
80 MB FREE HARDISK STORAGE
INSTALL PROGRAM:
MASUKAN CD PROVIEW
IKUTI PETUNJUK TAMPILAN KOMPUTER AUTO-RUN
BILA TIDAK AUTO-RUN
EXPLORE CD, KLIK D:\SETUP.EXE
IKUTI PETUNJUK KOMPUTER
PASSWORD:
GUNAKAN USER NAME = PASSWORD
CONTOH Modify => PASSWORDNYA => Modify
RUNNING PROGRAM, MENJALANKAN
PROGRAM.
SETELAH INSTALASI SOFTWARE SELESAI.
MAKA AKAN ADA ICON-SHORTCUT DI
DESKTOP UNTUK MENJALANKAN
PROVIEW YG SUDAH DI INSTAL.

FUNGSI SHORTCUT:
1. MENJALANKAN PROVIEW TANPA FILE
ATAU SCHEME SETTING.

2. MENJALANKAN PROVIEW DENGAN FILE


ATAU SCHEME FORM 6 DEFAULT DARI
PABRIKAN.

3. MENJALANKAN PROVIEW DENGAN FILE


ATAU SCHEME FORM 6 –TS DEFAULT
DARI PABRIKAN.

4. MENJALAKAN UPGRADE FORM 6.

5. MENJALANKAN PROGRAM TCC-EDITOR


ATAU PROGRAM EDITOR UNTUK KURVA
PROTEKSI.
LOGIN / LOGOUT
KLIK PANAH PADA BOX “NAME”

ADA TIGA PILIHAN LEVEL:

•VIEW : HANYA UNTUK MELIHAT METERING


& DATA EVEN, CHECK SETTING & PRINT
SETTING.

•OPERATE : OPSI INI SELAIN FUNGSI LEVEL


VIEW JUGA FUNGSI MENGOPERASIKAN
SOFTWARE, DOWNLOAD SCHEME,
SETTINGS, DAN FIRMWARE. MENGHAPUS
EVEN. TAPI TIDAK UNTUK MELAKUKAN
MODIFIKASI.

•MODIFY : MEMPUNYAI KAPABILITAS


LEVEL OPERATE PLUS KEMAMPUAN UNTUK
MEMBUAT SETTING SCHEME DAN
MODIFIKASI STRUKTUR.

KLIK BOX “PASSWORD”

PASSWORD ADALAH SAMA DENGAN NAME

Anda mungkin juga menyukai