Bacaan
σ=P/3 Hasil uji CBR
Arloji P=9.573*
n (Inch) b (lbs) (Psi)
Beban (b) 400.00
350.00
0.000 0.00 0.00 0.00
300.00 293.57
0.025 20.00 191.46 63.82
250.00
Tekanan (Psi)
0.050 45.00 430.79 143.60
223.37
0.075 60.00 574.38 191.46 200.00
0.100 70.00 670.11 223.37 150.00
0.125 77.00 737.12 245.71
100.00
0.150 82.50 789.77 263.26
50.00
0.175 87.50 837.64 279.21
0.200 92.00 880.72 293.57 0.00
0.000 0.050 0.100 0.150 0.200 0.250 0.3
0.225 96.50 923.79 307.93
Penurunan (inch)
0.250 101.00 966.87 322.29
0.275 105.00 1005.17 335.06
0.300 109.00 1043.46 347.82
CBR 1 = 22.33%
CBR 2 = 19.57%
JADI NILAI CBR YANG DIGUNAKAN DAN DI LAPORKAN ADALAH NILAI UNTUK PENETRASI 0,1 KARENA SESUAI DENGA
asil uji CBR
ASI 0,1 KARENA SESUAI DENGAN MODUL PRAKTIKUM MEKANIKA TANAH II. II (NILAI MAKS).