Lembar Kerja Simulasi KONTROL CAHAYA

NAMA : Ana Surya Ningrum NRP :0920040092

Lib. komponen yg digunakan :


Sensor cahaya :LDR Transistor : BD139
Resistor :RES Lampu :LAMP
Opamp :LM741 Relay : RELAY(24V)
Potensiometer :POT-HG Baterai : CELL
Diode :DIODE

Dimana :
Vin : tegangan output sensor (LDR)
Vref : teganganreferensi

Dari gambar rangkaian diatas, ukur tegangan pada Vin, Vref, dan Vout
Atur tegangan referensi (Pot) = 3 Volt
Atur intensitas cahaya (LDR) mulai dari 30 – 100 lux dg kenaikan setiap 5 lux
Isikan tabel berikut
No. Lux Vref Vin Vout RELAY(ON/OFF) Lamp(Nyala/Padam)
1. 30 +3.01v +4.87v +10.7v ON Nyala
2. 35 +3.01v +4.49v +10.7v ON Nyala
3. 40 +3.01v +4.18v +10.7v ON Nyala
4. 45 +3.01v +3.91v +10.1v ON Nyala
5. 50 +3.01v +3.68v +10.1v ON Nyala
6. 55 +3v +3.48v +10.1v ON Nyala
7. 60 +3v +3.3v +10.1v ON Nyala
8. 65 +3v +3.14v +10.1v ON Nyala
9. 70 +3v +2.99v -11v OFF Padam
10. 75 +3v +2.86v -11v OFF Padam
11. 80 +3v +2.74v -11v OFF Padam
12. 85 +3v +2.63v -11v OFF Padam
13. 90 +3v +2.54v -11v OFF Padam
14. 95 +3v +2.44v -11v OFF Padam
15. 100 +2.99v +2.36v -11v OFF Padam

Dari tabel tersebut buat kurva karakteristik In / Out :

1. Vin >< Vout


Y-Vout
Y-Vout

15

10

0
0 1 2 3 4 5 6
-5

-10

-15

Kesimpulan : Semakin besar LUX yang ditambahkan semakin kecil juga Vin-nya dan Vout juka akan
menurun pada pertengahan lux yaitu 30-40=+10,7v ; 45-65=+10,1v ; 70-100=-11v.

1. Lux ><Relay

Y-Relay
1.2

0.8

0.6

0.4

0.2

0
40 60 80 10
0 20 0 120
-0.2

Y-Relay

Kesimpulan : Semakin bertambah nilai LUX berpengaruh juga terhadap perubahan Relay
yaitu 30-65=ON ; 70-100=OFF.
2. Lux ><Lamp

Y-Relay
1.2

0.8

0.6

0.4

0.2

0 20 40 60 80 100 120
-0.2

Y-Relay

Kesimpulan : Semakin bertambah nilai LUX berpengaruh juga terhadap perubahan Relay
yaitu 30-65=Nyala ; 70-100=Padam.