( 34,2 % )
(
HHV =33950(50,4 %)+144200 (5,8 % )−
8 ) + 9400(0,3 %) [ kJ /kg ]
100
( 576,072 )+ ( 34,5 (1,525 ) )+ 1,296
Ath =
100
629,9805
Ath=
100
Ath =6,3 kg udara /kg bb
Excess Air
% O2 ×100
EA=
(21−% O2)
34,2% ×100
EA=
(21−34,2 %)
34,2
EA=
20,658
EA=1,65
Kebutuhan udara actual
Aak = (1+ EA ) × A th
Aak = (1+1,65 ) × 6,3
Aak =16,695 kg udara /kg bb
c. Efisiensi ketel
a. Loses gas asap kering :
Berat CO2 = 3,66 (C)
Berat SO2 = 2,00 (S)
Berat H2O = 9,00 (H2)
Berat N2 = 77% (Aak)
Berat O2 = 23% (EA) (Ath)