DATA BAHAN
Air Raksa
ρ (gr/ml) μ (cP) ρ (gr/ml) μ (cP)
1 0.899 13.6 -
∆h (ft)
Bukaan kran
Biru Ungu Kuning Hitam
1 0.0771 0.06724 0.05576 0.03936
1.25 0.1181 0.08200 0.06560 0.05576
1.5 0.1410 0.11972 0.10332 0.09184
Friction Loss
Energi
V^2 di setiap pipa (ft²/s²)
Bukaan Kf
D H G
1 0.75 0.0694 0.0255684 0.033030
1.25 0.75 0.0975 0.0358938 0.046369
1.5 0.75 0.1179 0.0434315 0.056106
A(ft2)
Bukaan
Pipa F Pipa H Pipa G Pipa I
1 0.03322 0.0233 0.0205 0.00891
1.25 0.03322 0.0233 0.0205 0.00891
1.5 0.03322 0.0233 0.0205 0.00891
Tabel keseluruhan
Perhitungan Power Pompa
Q Qm E kinetik
Bukaan Efisiensi
(cuft/s) (lbm/s) (ft lbf/lbm)
1 0.00373 0.23258805 0.7 0.000539
1.25 0.00441 0.27557826 0.7 0.001515
1.5 0.00486 0.30313609 0.7 0.001833
∆H (cm)
Kuning Hitam
1.8 1.3
1.6 1.1
1.7 1.2 konversi
2.1 1.8 1 ml = 3.53147E-05 cubft
1.9 1.6 1 cm = 0.0328 ft
2 1.7 1m 3.2808 ft
3.3 2.9
3 2.7
3.15 2.8
Konversi
Air Raksa
ρ (lbm/cubft) μ (lbm/ft.s) ρ (lbm/cubft) μ (lbm/ft.s)
62.428 0.0006041 0.21785 -
Energi Potensial
(ft.lbf/lbm)
1.64
g karena ekspansi
V^2 di tiap pipa gc hf (ft lbf/lbm) Total Hf (ft lbf/lbm)
Pipa F (ft lbm/lbf s²) Pipa C ke G Pipa C ke G
0.012578 32.174 0.0003559
0.017658 32.174 0.0004996 0.0014601
0.021366 32.174 0.0006046
∆P g/gc
ft lbf/lbm
2119.9569
2121.2367
2123.3355
gc Energi Kinetik
Nre α
(ft.lbm/lbf.s2) (ft.lbf/lbm)
3653.2028 2 32.174 0.000539
4328.4394 1 32.174 0.001515
4761.2833 1 32.174 0.001833
Ʃff
(ft lbf/lbm)
0.001648887
Ʃff
(ft lbf/lbm)
0.018946326
Ʃff
(ft lbf/lbm)
0.024721589
Ʃff
(ft lbf/lbm)
0.000145862
Ʃff
(ft lbf/lbm)
0.000178032
ft lbf/lbm)
I J
0.002037918 0.006497
0.002860895 0.009121
0.003461683 0.011037
0.00346628 0.0031719
Q
Bukaan
Debit (cuft/s)
(cuft/s) Grafik Hubungan Bukaan Valve dengan Debit
1 0.00372570085 0.006
1.25 0.0044143375
0.005
1.5 0.00485577125
f(x) = 0.0022601408 x + 0.001506760
0.004 R² = 0.984299903876962
0.003
0.002
0.001
0
0 0.25 0.5 0.75 1 1.25 1.5 1
Bukaan Valve
Perubahan tekanan
Q ∆P (E tekanan)
(cuft/s) (ft lbf/lbm)
(ft lbf/lbm)
2121.00000
2120.00000
2119.00000
2118.00000
0.0036 0.0038 0.004 0.0042 0.0044 0.0046 0.0048
Debit (cuft/s)
Q Friction Loss
(cuft/s) (ft lbf/lbm) Grafik Hubungan Debit dengan Total Friksi
0.0037257009 0.065972526343
0.125
0.0044143375 0.072859189699
0.0048557713 0.10726971869 0.1
f(x) = 34.2221008588334 x − 0.06621415738039
Friction Loss
R² = 0.776048432814944
0.075
(ft lbf/lbm)
0.05
0.025
0
0.003 0.0045 0.006
Debit (cuft/s)
0.05
Fric
(ft l
0.025
0
0.003 0.0045 0.006
Debit (cuft/s)
P ow er pompa (H p)
Grafik Hubungan Total Friksi dengan Power Pompa
Friction Loss wp percobaan
2
(ft lbf/lbm) (Hp)
1.75
0.0659725263 1.283031283877 1.5 f(x) = 7.87014875592101 x + 0.847390607739336
0.0728591897 1.521101841838 R² = 0.777788972102499
1.25
0.1072697187 1.674893597891 1
0.75
0.5
0.25
0
0.06 0.08 0.1
.0022601408 x + 0.001506760533333
984299903876962
alve
388433 x + 2108.98709952097
880598
Debit (cuft/s)
588334 x − 0.066214157380397
814944
5 0.006
s)
5 0.006
s)
+ 0.847390607739336
0.1 0.12
.lbf/lbm)