MEKANISME PERPINDAHAN PANAS

KONDUKSI _2

TIUR ELYSABETH, ST., MT


PROGRAM STUDI TEKNIK KIMIA
FAKULTAS TEKNIK
UNIVERSITAS SERANG RAYA
PERPINDAHAN PANAS KONDUKSI PADA
SILINDER

T2 r2

r1

T1

Keterangan :
L = panjang pipa
r1 = jari-jari dalam
r2 = jari-jari luar
T1 = temperatur permukaan dalam
T2 = temperatur permukaan luar
• Aliran panas berlangsung ke arah radial (R),
sehingga luas permukaan perpindahan
panas adalah:
Ar = 2πrL
• Penulisan Hukum Fourier menjadi :

Boundary Condition :
r = r1 T = T1
r = r2 T = T2
Karena :
Pipa Silinder Dinding Berlapis

r1 T1
r2
A T2
B r3
C
T3
r4 T4
CONTOH

• Sebuah pipa uap panas mempunyai suhu dalam


350oC. Diameter dalam pipa adalah 8 cm, tebalnya
10 mm. Pipa itu dilapisi dengan lapisan isolasi yang
mempunyai k= 0,5 W/m.oC setebal 10 cm, diikuti
dengan lapisan lain dengan k = 0,25 W/m.oC setebal
5 cm. Suhu luar isolasi adalah 30oC. Hitunglah
kehilangan kalor per satuan panjang andaikan k= 47
W/m.oC untuk pipa!
Overall Heat Transfer Coefficient (U)
• U adalah koefisien perpindahan panas yang
merupakan hasil gabungan dari proses konduksi dan
konveksi
• Satuan U W/m2 °C atau Btu/hr.ft2.°F
U pada Bidang Datar

Ta
T1

Fluida A k Fluida B
h1 h2

T2
q

Tb
dan

sehingga
Untuk bidang datar tunggal

Untuk bidang datar disusun seri


L

r1
r2

Ta

T1
T2
T

Tb
r
Luas perpindahan panas pada pipa :
 pipa in, A1 = 2πr1L
 pipa out, A2 = 2πr2L

sehingga
Bidang dalam
Bidang luar
TEBAL ISOLASI KRITIS
• Ketebalan suatu isolasi untuk menahan panas
maksimum

Contoh : pipa silinder

r1

rc

ha
Heat Loss by Convection and Conduction and Overall U

• Saturated steam at 267 °F is flowing inside a ¾ in steel pipe having an ID of 0.824


in and OD of 1.050 in. The pipe is insulated with 1.5 in of insulation om the
outside. The convective coefficient for the inside steam surface of the pipe is
estimated as h1 = 1000 Btu/hr.ft2.°F, and the convective coeffiecient on outside of
the lagging is estimated as h2 = 2 Btu/hr.ft2.°F. The mean thermal conductivity of
the metal is 45 W/m.K or 26 Btu/hr.ft2.°F and 0.064 W/m.K or 0.037 Btu/hr.ft.°F
for the insulation.
a) Calculate the heat loss for 1 ft of pipe using resistances if the surrounding air at
80°F
b) Repeat using the overall Ui based on inside area A 1
c) Repeat using the overall Uo based on inside area A3
Critical Radius for Insulation
• A metal steam pipe having an outside diameter of 30 mm
has a surface temperature of 400 K and is to be insulated
with an insulation having a thickness of 20 mm and a k of
0.08 W/m.K. The pipe is exposed to air at 300 K and a
convection coefficient of 30 W/m2.K.
a) Calculate the critical radius and the heat loss per m of
length for the bare pipe
b) Calculate the heat loss for the insulated pipe assuming that
the surface temperature of the pipe remains constant