SEMARANG
PRAKTEK
PENGUJIAN KAPASITAS
BATERE
MENYIAPKAN ALAT :
PERALATAN KERJA DAN ALAT UJI
BUKU CATATAN / LEMBAR KERJA
RECTIFIER ( BATTERY CHARGER )
PENCATATAN / PENGUKURAN :
DATA BATERE
TEGANGAN PER-SEL BATERE
BERAT JENIS ELEKTROLIT
TEMPERATUR ELEKTROLIT
PEMERIKSAAN :
TINGGI PERMUKAAN / LEVEL ELEKTROLIT
KEKENCANGAN MUR BAUT KLEM ANTAR SEL
DIAGRAM PENGUJIAN
BATERE
YG DIUJI
BATTERY
CHARGER
NFB
NFB
ALAT UJI
ISA BTS.100. PLUS
LAPTOP
COMPUTER
PRINTER
SETING TEST KAPASITAS DAN PENGISIAN MUATAN
PRINSIP PENGUJIAN
HASIL UJI KAPASITAS PADA BATERE DIDASARKAN PADA LAMANYA PENGOSONGAN
MUATAN YANG DICAPAI, SELANJUTNYA DIHITUNG KEDALAM SATUAN PROSEN ( % )
1. PERIKSA TEMPERATUR SELURUH SEL BATERE APAKAH KONDISI NORMAL. BILA MELEBIHI
YANG DIIJINKAN TUNGGU SAMPAI TEMPERATUR ELEKTROLIT TURUN.
2. PERIKSA LEVEL CAIRAN ELEKTROLIT BATERE, BILA KURANG TAMBAHKAN AIR MURNI.
3. LAKUKAN PENGISIAN DENGAN MENGOPERASIKAN RECTIFIER YANG TERSEDIA, SETING
BESARNYA ARUS DAN TEGANGAN OUTPUT.( SEBAIKNYA GUNAKAN METODA ARUS
KONSTAN ).
4. CATAT TIAP JAM BESARAN ARUS, TEGANGAN, TEMPERATUR SETIAP SEL BATERE.
5. OFF-KAN RECTIFIER BILA PENGISIAN SUDAH SUDAH DINYATAKAN PENUH.
6. HENTIKAN PENGISIAN APABILATERDAPAT SEL YANG TIDAK NORMAL ATAU SUHU
ELEKTROLIT DIATAS 35 oC, TUNGGU SAMPAI TURUN DAN LANJUTKAN PENGISIAN.
HAL – HAL PENTING YANG HARUS DIPERHATIKAN
KETIKA PENGISIAN BERLANGSUNG
1. HENTIKAN PENGISIAN APABILA TERDAPAT SEL YANG TIDAK NORMAL ATAU SUHU
ELEKTROLIT DIATAS 35 oC, TUNGGU SAMPAI TURUN ATAU KELUARKANSEL YANG
TIDAK NORMAL DAN LANJUTKAN PENGISIAN.
2. PERIKSA SECARA KONTINU KERJA RECTIFIER.
3. BANDINGKAN HASIL UKUR TEGANGAN DAN ARUS ANTARA PENUNJUKAN PADA
RECTIFIER DENGAN DI BATERE.
4. PENGISIAN DIHENTIKAN BILA SUDAH DIANGGAP PENUH ATAU TIAP SEL TELAH
MENCAPAI TEGANGAN MAKSIMUMNYA ( UNTUK BATERE ALKALI 1,7 VOLT PER-SEL )
5. KONDISI BATERE TIDAK BAIK BILA WAKTU PENGISIAN SINGKAT.
6. BILA KETIKA PENGISIAN TERDAPAT SALAH SATU SEL YANG TIDAK NORMAL JANGAN
DIHUBUNG SINGKATKAN.
PEMBUATAN LAPORAN
ISI LAPORAN :
1. DAFTAR ISI
2. LATAR BELAKANG
3. TANGGAL PELAKSANAAN
4. DATA BATERE YANG DI UJI
5. DATA RECTIFIER ( PENGISI BATERE )
6. DATA ALAT UJI YANG DIGUNAKAN
7. HASIL PENGUJIAN
8. KESIMPULAN
9. REKOMENDASI
10. PENUTUP.
LAMPIRAN :