PERTAMINA DALAM PERHITUNGAN KUANTITAS MINYAK
MENGGUNAKAN SISTEM METRIC , BERDASARKAN ORDONANSI
TERA TH. 1949 DAN UNDANG UNDANG REPUBLIK INDONESIA NO.
2 TENTANG METROLOGI LEGAL.
5
ASTM TABEL NO. 1.
INTERRELATION OF UNIT MEASUREMENT ASTM - IP 5 A
UNTUK MENGKONVERSI DARI SUATU UNIT SATUAN KE
SATUAN UNIT LAINNYA , CUKUP DENGAN MENGALIKAN
( MULTIPLY BY ) FAKTOR PENGALI YANG TERLETAK
DISEBELAH KANAN .
TO CONVERT MULTIPLY BY
I. LENGTH.
* METER TO FEET 3.2808
0.30480
* FEET TO METER 0.25400
* INCHES TO CENTIMETERS
II.WEIGHT .
LONGTONS TO METRIC TONS. 0.97185
METRIC TONS TO LONGTONS. 0.98421
6
2.20462
ASTM TABEL NO. 1.
INTERRELATION OF UNIT MEASUREMENT ASTM - IP 5 B
III.VOLUME.
LITRES TO US BARREL
0.0062900
158.984
US BARREL TO LITRES .
3.78533
US GALLONS TO LITRES
7
| 1 |
M A T E R I K U L I A H A R U S M I N Y A K K O R P O R A T
I . W A W A S A N K O R P O R A T I N D U S T R I M I G A S
I I . W A W A S A N I N D U S T R I M I G A S D I T . H I L I R .
a . K E G I A T A N P E R T A M I N A D I T . H I L I R
B I D A N G P E N G O L A H A N .
b . K E G I A T A N P E R T A M I N A D I T . H I L I R
B I D A N G T R A N S P O R T A S I .
c . K E G I A T A N P E R T A M I N A D I T . H I L I R
B I D A N G P E M A S A R A N D A N N I A G A .
d . Q U A N T I T Y A C C O U N T I N G P E R T A M I N A .
I I I . S I S T I M P E N G U K U R A N M I N Y A K .
A . S T A T I C M E A S U R E M E N T :
1 . M A N U A L T A N K G U A G I N G .
P E R A L A T A N U K U R S T A N D A R D .
T A T A C A R A P E N G U K U R A N T I N G G I
P E R M U K A A N C A I R A N ( M I N Y A K / A I R )
6
ASTM TABEL NO. 2 .
TEMPERATUR CONVERSION
O
C * O
F
37.8 100 212.0
38.3 101 213.8
38.9 102 215.6
DST.
A. STATIC MEASUREMENT :
7
ASTM TABEL NO. 3
CONTOH SOAL :
API GRAVITY 60 O F = 61 , 25
BERAPA DENSITY 15 O C ?
9
8
( 61.25 – 61.20 )
D 15 oC = 0.7341 -{ --------------------- } X (0.7341–0.7337 )
( 61.30 - 61.40 )
DST. ….
CONTOH SOAL :
DIKETAHUI : SG 60/60 0 F = 0.7339
DITANYA : BERAPA DENSITY 15 0 C ?.
11
JAWAB : MENGUNAKAN RUMUS INTERPOLASI SBB :
( 0.7339 - 0.7330 )
D 15 O C = { --------------------- } X (0.7338 - 0.7328 ) + 0.7328
( 0.7340 - 0.7330 )
( 0.0009 )
= ------------ X 0.0010 + 0.7328
(0.0010 )
12
ASTM TABLE NO 51
DENSITY 15 0
C SPECIFIC GRAVITY 60 0 F API GRAVITY 60 0 F
CONTOH SOAL :
( DEN.15 0 C - BOT.DEN.15 0 C )
API 60 0 F = { ----------------------------------------} X ( UP DEN.150C– BOT DEN.150C) =?
( BOT. API 60 0 F – UP.API 60 0 )
( 0.7337 - 0.7330 )
API 60 0 F = 61.48 - { --------------------- } X ( 61.48 – 61.22 )
( 0.7340 - 0.7330 )
( 0.0007 )
= 61.48 - ------------ X 0.26
(0.0010 )
= 61.48 - 0.182
API 60 0 F = 61.298
14
ASTM TABLE NO . 52
BARRELS AND IMPERIAL GALLONS TO US GALLONS , LITTERS
15
CONTOH SOAL :
JAWAB :
16
ASTM TABEL NO. 53
UNTUK MENGKONVERSI DENSITY OBSERVED MENJADI
DENSITY AT 15 0 C
OBSERVED DENSITY
OBSERVED
TEMP. 0.710 0.711 0.711
0
C
CORRESPONDING DENSITY TO 15 O C
( 43.25 - 43.00 )
D 15 0 C = 0.7329 + {------------------- } X ( 0.7333 - 0.7329 )
( 43.50 - 43.00 )
0.25
= 0.7329 + ( -------- ) x 0.0004
0.50
18
( 43.25 - 43.00 )
D 15 0 C = 0.7339 + { -------------------- } x ( 0.7333 - 0.7329 )
( 43.5 - 43.0 )
0.25
= 0.7339 + ( ----- ) x 0.0004
0.50
= 0.7339 + 0.0002 = 0.7341
OBS’D DENSITY AT 15 0
C
0
C FACTOR FOR REDUCING VOLUME TO 15 0
C
20
CONTOH SOAL ASTM TABLE NO. 54 :
JAWAB :
POINT 1 :
( 30.25 – 30.0 )
FFRV 15 0 C = 0.9823 - {------------------- } x ( 0.9823 – 0.9817 )
( 30.5 – 30.0 )
( 0.25 )
= 0.9823 - -------- x 0.0006 = 0.9823 - 0.0003 = 0.9820
( 0.50 )
POINT 2 :
30.25 – 30.0 )
FFRV 15 0 C = 0.9825 - {------------------- } x ( 0.98235– 0.9819 )
( 30.5 – 30.0 )
( 0.25 )
= 0.9825 - -------- x 0.0006 = 0.9825 - 0.0003 = 0.98202
( 0.50 )
22
POINT 3 :
( 0.7227 – 0.7200)
FFRV 15 0 C = 0.9820 - { ------------------- } x ( 0.9822 – 0.9820 )
(0.7250 -0.7200 )
0.0007
= 0.9820 - ( -------- ) x 0.0002 = 0.9820 - 0.000108 = 0.982108
0.0050
23
ASTM TABLE 56
UNTUK MENCARI KONVERSI KE METRIC TONS
24
CONTOH SOAL :
JAWAB :
0.7337 – 0.7330)
W.C.F = 1366.3 - { ------------------- } x (1366.3 – 1364.5 )
(0.7340 -0.7300 )
0.0007
= 1366.3 - ( -------- ) x 1.8 = 1366.3 – 1.26 = 1365.04
0.0010
25
ASTM TABLE 57
UNTUK MENCARI WEIGHTED CONVERTION FACTOR
TO LONG TONS DAN TO SHORT TONS
26
CONTOH SOAL :
JAWAB :
( 0.7337 – 0.7330 )
W.C.F = 0.7203 + { ------------------- } x ( 0.7213 – 0.7203 )
(0.7340 -0.7330 )
0.0007
= 0.7203 + ( -------- ) x 0.0010 = 0.7203 + 0.0007 = 0.7210
0.0010
27
MENGHITUNG VOLUME DI TANKI DARAT
29
CONTOH TABEL TANKI KALIBRASI NO 2
DI DEPOT TASIKMALAYA
DIKETAHUI
DATA HASIL PENGUKURAN TANKI NO. 2 DI DEPOT TASIKMALAYA
ADALAH SBB :
TINGGI CAIRAN = 6.978 MM , TINGGI AIR = 16 MM , TEMP.
TANKI = 31 0 C , OBS’D DENSITY 0.7225 TEMP. 30 0 C .
DITANYA :
1. BERAPA VOLUME MINYAK LITER OBS’D ?
2. BERAPA VOLUME MINYAK LITER AT 15 0 C ?
3. BERAPA VOLUME MINYAK BBLS 60 0 F ?
4. BERAPA BERAT MINYAK DALAM METRIC TONS ?
5. BERAPA BERAT MINYAK DALAM LONG TONS. ?
31
JAWAB :
32
III.4 SUHU DALAM TANKI = 31 0
C
33
IV.1 VOLUME AT 15 0 C ( 2.068.259 X 0.981882 ) = 2.030.786 LTR.
34
MENGHITUNG VOLUME DI TANKI KAPAL
35
> EVEN KEEL : KAPAL PADA POSISI RATA DAN TEGAK .
TRADING ZONE :
36
> LOADED DISPLACEMENT : BERAT KAPAL DALAM KEADAAN
DIMUATI .
37
CONTOH SOAL PERHITUNGAN DEMMURAGE :
38
JAWAB :
39
TABEL TANKI KAPAL
> SETIAP CARGO OIL TANK DILENGKAPI DENGAN TABEL TRIM DAN
HEEL CORRECTION .
40
CARGO OIL TANK CENTER NO. 3
TRIM CORRECTION ( IN MM ) ULLAGE HOLE
ULLAGE ULLAGE
(M) (-1M ) (1M) (2M) (3M) (4M) (5M) (M)
0.06 - - - - - 690 0.06
0.20 - - - - 552 590 0.20
0.33 - - - 414 457 503 0.33
0.47 - - 276 311 366 416 0.47
0.61 - 138 174 235 292 344 0.61
0.71 38 72 140 199 254 306 0.71
0.88 -41 53 106 156 211 265 0.88
1.00 -47 50 100 150 201 253 1.00
1.10 -50 50 99 149 199 250 1.10
1.14 -50 50 99 149 199 250 1.14
2.00 -50 50 99 149 199 250 2.00
7.00 -50 50 99 150 201 254 7.00
15.00 -49 50 100 151 203 257 15.00
15.41 -49 50 100 151 203 257 15.41
15.55 -49 50 100 151 203 257 15.55
15.69 -49 50 100 151 203 247 15.69
15.85 -49 50 100 151 192 211 15.85
15.97 -49 50 100 133 148 150 15.97
16.11 -49 50 72 78 79 77 16.11
16.16 -49 41 50 49 46 42 16.16
16.20 -49 26 28 25 20 13 16.20
41
16.27 -53 -2 -10 -13 -17 -21 16.27
CARGO OIL TANK CENTER NO. 3
HEEL CORRECTION ( IN MM ) ULLAGE HOLE
PORT SIDE HEEL
ULLAGE ( M ) 5 0
4 0
3 0
2 0
1 0
0.69 60 - - - -
0.73 34 -34 - - -
0.79 -4 -34 -41 - -42
0.83 -27 -48 -60 -72 -46
0.90 -62 -72 -79 -81 -51
0.96 -89 -93 -91 -77 -51
1.00 -98 -102 -97 -82 -55
1.14 -161 -163 -142 -113 -68
1.16 -176 -169 -147 -116 -69
1.24 -208 -192 -165 -127 -69
1.38 -251 -224 -100 -136 -69
1.54 -287 -249 -205 -136 -69
1.74 -318 -269 -205 -136 -69
1.92 -336 -269 -205 -136 -69
2.00 -336 -269 -205 -136 -69
7.00 -309 -252 -194 -132 -68
42
DST. …
CARGO OIL TANK CENTER NO. 3
HEEL CORRECTION ( IN MM ) ULLAGE HOLE
PORT SIDE HEEL
ULLAGE ( M ) 5 0
4 0
3 0
2 0
1 0
1 0 2 0
3 0
4 0
5 0
ULLAGE ( M )
1 0 2 0
3 0
4 0
5 0
ULLAGE ( M )
I.1 DRAFT
I.2 HEEL
II.1 ULLAGE CAIRAN
II.2 TRIM CORRECTION
II.3 HEEL CORRECTION
II.4 CORRECTED ULLAGE CAIRAN
III.1 TINGGI TANKI
III.2 WATTER INNAGE
III.3 F.W. ULLAGE
III.4 TRIM CORRECTION
III.5 HEEL CORRECTION
III.6 F.W. ULLAGE CORRECTED
IV.1 GORSS OBS’D VOLUME CAIRAN
IV.2 GROSS OBS’D VOLUME AIR
IV.3 NET. OBS’D VOLUME CAIRAN
( POINT IV.1 - POINT IV.2 )
47
LANJUTAN TAHAPAN PERHITUNGAN TANKI KAPAL .
48
CONTOH SOAL PERHITUNGAN VOLUME DI TANKI KAPAL
HITUNGLAH :
1. VOLUME PREMIUM AT LITER 15 0 C ?
2. VOLUME PREMIUM AT BBLS 60 0 F ?
3. BERAT PREMIUM DALAM LONG TONS ?
4. BERAT PREMIUM DALAM METRIC TONS ?
49
JAWAB SOAL PERHITUNGAN TANKI KAPAL
51
VI.3 VOLUME LITER AT 15 0 C = 335.451,570 LITER
( 341.629,6 X 0.981916 )
52
VIII.2 BERAT BBM DALAM LONG TONS = 241,118 L/T
( 333.774 X 0.7224 )
1000
53