Run 3
CP = y 4.2591387387
y1 4.248
y2 4.27
x 51.7
x1 48.89
x2 54.44
y 4.2591387387
CP dalam satuan BTU/lbF 1.0173
Q Inner pipe
W.Cp.dT (BTU/jam) 1386.1819886277
B. LMTD
LMTD dalam C 19.9893287784
LMTD dalam F 67.9807918011
Perhitungan Reynold
T in pipe 125.06
u=y 0.000537206
y1 0.000562
y2 0.000513
x 125.06
x1 120
x2 130
y 0.000537206
u dalam satuan (Lb/jamFt) 1.2995268952
Re = D1.Gp /u 7412.137358985
H1 227.5186893383
1.86
1008.7263532948
12.4812741313
Faktor pengotor
Rd -0.0122356648
Re 6002.9115
F 0.0412550052
P(densitas) kg/ms3
y1 988.8
y2 985.7
x 125.06
x1 120
x2 130
y 987.2314
P(densitas) dalam kg/ft3 27.948520934
Δ Pf 392.313967212
2601.7070372547
Δ Pf 0.1507909851
ΔP= 0.0292665625
I. Menentukan n
n 1
%panas 0.00000000000
C = Cp . W
W(Kg/s) 0.016445523
Cp dalam J 4259.1387387387
Ch 70.0437640769
Cmin 70.0437640769
Cmax 207.562057065
eh 0.0385316453
Sigma paralel single pass He
Q dalam w 406.1513226679
U 14195.9432294556
NTU 0.0269485808
Sigma 0.0176960816
1.3374593848
0.013231117
Fluida dingin Celsius Fahrenheit
T in = 29.6 85.28
Suhu
Tout = 33.8 92.84
V Rata- Rata 31.7 89.06
3 dT 4.2 -7.56
177.66
391.56264
Jadi w fluida panas = 391,56264Lb/jam
CP = y 4.2070630631
y1 4.198
y2 4.208
x 31.7
x1 26.67
x2 32.22
y 4.207
CP dalam satuan BTU/lbF 1.0048
Q Inner pipe
W.Cp.dT (BTU/jam) -2974.54154
B. LMTD
LMTD dalam C 31.6535733668
LMTD dalam F 88.9764320602
Gp 56635.6064
Gp dalam kg/sft2 7.1360864064
Perhitungan Reynold
T in pipe 89.06
u=y 0.00077393
y1 0.00086
y2 0.000765
x 89.06
x1 80
x2 90
y 0.00077393
u dalam satuan (Lb/jamFt) 1.8721735238
Re = D1.Gp /u 1291.728764735
H0 159.914713019
1.86
216.8089169167
14.5703512881
A dalam m2 0.0001329662
G. Menghitung Pressure drop
Re 6002.9115
F 0.0480290265
P(densitas)
y1 995.8
y2 994.9
x 89.06
x1 80
x2 90
y 994.9846
P(densitas) dalam ft 28.168014026
Δ Pf 42.3684011539
2178.4686004724
Δ Pf 0.0194487087
ΔP= 0.0038043854
C = Cp . W
W(Kg/s) 0.049336569
Cp dalam J 4207.0630630631
Cc 207.562057065