Laboratorium Geomekanika
Departemen Teknik Pertambangan
Institut Teknologi Bandung
Parameter A = 22
Parameter B = 24
Parameter C = 16
length: 1-3 m
separation: 0.1-1.0 mm
slightly rough
no infilling
slightly weathered
Discontinuity length
Separation
Roughness
Infilling
12
13
10
4
4
3
6
Groundwater
Total sebelum penyesuaian
22
7
64
Shotcrete
RQD
Jn
Jr
Ja
Jw
SRF
= 90
= 4
= 3
= 1.0
= 1.0
= 15
= 2.3 m
= 2.7 m
Shotcrete
unreinforced
tebal = 50 mm
Drifts
2.4 m long rock bolt
0.75 m spacing
100 mm reinforced shotcrete
Intersections
10 m long cable
3.0 m spacing
Drifts
2.3 m long rock bolt3)
1.1 m spacing
120 mm reinforced shotcrete
Intersections
2.3 m long rock bolt3)
<1 m spacing
150 mm reinforced shotcrete
Drifts
2.3 m long rock bolt3)
1.5 m spacing
60 mm reinforced shotcrete
Intersections
2.3 m long rock bolt3)
1.3 m spacing
90 mm reinforced shotcrete
Installed Support
Drifts
2.4 m long rock bolt
1.25 - 1.0 m spacing
50 mm reinforced shotcrete
Intersections
8 m long rock bolt
2 m spacing
Drifts
2.4 m long rock bolt3)
1.5 m spacing
50 mm reinforced shotcrete
Intersections
2.4 m long rock bolt3)
1.3 m spacing
90 mm reinforced shotcrete
Drifts
2.4 m long rock bolt3)
1.6 m spacing
with no shotcrete
Intersections
2.4 m long rock bolt3)
1.7 m spacing
45 mm reinforced shotcrete
Drifts
2.4 m long rock bolt
1.0 m spacing
50 mm reinforced shotcrete
Intersections
8 m long rock bolt
2 m spacing
Drifts
2.4 m long rock bolt3)
1.6 m spacing
50 mm reinforced shotcrete
Intersections
2.4 m long rock bolt3)
1.3 m spacing
90 mm reinforced shotcrete
Drifts
2.4 m long rock bolt3)
1.8 m spacing
45 mm reinforced shotcrete
Intersections
2.4 m long rock bolt3)
1.5 m spacing
75 mm reinforced shotcrete
Installed Support
Drifts
2.2 m long rock bolt2)
1.5 m spacing
50 mm reinforced shotcrete
Intersections
2.2 m long rock bolt3)
1.3 m spacing
100 mm reinforced shotcrete
1) Determined using SRF values from Grimstad and Barton (1993) and Peck (2000)
2) Assuming an ESR = 1 for rock bolt length only
Installed Support
Drifts
2.2 m long rock bolt2)
1.5 m spacing
50 mm reinforced shotcrete
Intersections
2.2 m long rock bolt3)
1.3 m spacing
100 mm reinforced shotcrete
1) Determined using SRF values from Grimstad and Barton (1993) and Peck (2000)
2) Assuming an ESR = 1 for rock bolt length only
Installed Support
Drifts
2.3 m long rock bolt2)
1.7 m spacing
45 mm reinforced shotcrete
Intersections
2.3 m long rock bolt3)
1.4 m spacing
75 mm reinforced shotcrete
1) Determined using SRF values from Grimstad and Barton (1993) and Peck (2000)
2) Assuming an ESR = 1 for rock bolt length only