NERACA ENERGI
Tref = 780F
INPUT
1. Sensibel heat udara kering
Q = n . Cp. t
= n . Cp. (78 78)0F
= 0
OUTPUT
1. Sensibel heat dari dry flue gas
Entalpi :
CO2 = 5,925 lbmol x (10,018)(553 78) = 28194,40875 Btu
CO = 0,097 lbmol x (7,058)(553 78) = 325,19735 Btu
O2 = 3,400 lbmol x (7,268)(553 78) = 11737,82 Btu
N2 = 39,149 lbmol x (7,0272)(553 78)= 130676,2301 Btu
= 170933,6562 Btu
4. HV CO tak terbakar
CO pada stack = 0,097 lbmol
HV = 0,097 x 67636 x 1,8
= 11809,2456 Btu
6. Entalpi steam = m . hg
= 220 lb x 1193,75 Btu/lb
= 262625 Btu
INPUT
Sensibel heat udara kering 0 Btu
Sensibel heat batubara 0
HV batubara 1190000
Laten heat H2O dalam udara 29148,66
Entalpi BFW 13821
TOTAL 1232969,66 Btu
OUTPUT
Sensibel heat dry flue gas 170933,6562 Btu
HV C tak terbakar dalam refuse 17778,6
Laten heat H2O moisture flue gas 94338,2355
HV CO tak terbakar 11809,2456
Sensibel heat refuse 966,6486
Entalpi steam 262625
Heat loss 674518,2741
TOTAL 1232969,66 Btu