Anda di halaman 1dari 2

CARA MENCARI DAN MENENTUKAN

TERMINAL REGULATOR
SEBELUM MELAKUKAN PENGETESAN SETEL JARUM AVOMETER PADA
SKALA IX

I. TERMINAL TERMINAL YANG BERHUBUNGAN DENGAN MASSA/BODY


1. TERMINAL L
TERMINAL L BERHUBUNGAN DENGAN MASSA/BODY DENGAN
TAHANAN 0 (NOL) AKAN TETAPI TAHANAN AKAN BERUBAH
MENJADI BESAR JIKA VOLTAGE RELAY DITEKAN (VOLTAGE RELAY
YANG TIDAK ADA TAHANANNYA)

2. TERMINAL E
TERMINAL E BERHUBUNGAN DENGAN MASSA/BODY DENGAN
TAHANAN 0 (NOL) DAN TAHANAN TIDAK BERUBAH JIKA
VOLTGERELAY/VOLTAGE REGULATOR DITEKAN

3. TERMINAL N
TERMINAL N BERHUBUNGAN DENGAN MASSA/BODY DENGAN NILAI
TAHANAN BESAR ( 50 )DAN TAHANAN TETAP/TIDAK BERUBAH
JIKA VOLTAGE RELAY/VOLTAGE REGULATOR DITEKAN

II. TERMINAL TERMINAL YANG TIDAK BERHUBUNGAN DENGAN


MASSA/BODY

1. TERMINAL YANG SALING BERHUBUNGAN ADALAH TERMINAL IG


DAN TERMINAL F (DIANTARA KETIGA TERMINAL YANG TIDAK
BERHUBUNGAN DENGAN MASSA)

TERMINAL F
BERHUBUNGAN DENGAN MASSA/BODY DENGAN TAHANAN 0
(NOL) JIKA VOLTAGE REGULATOR DITEKAN

TERMINAL IG
BERHUBUNGAN DENGAN MASSA/BODY DENGAN TAHANAN
+/-10 JIKA VOLTAGE REGULATOR DITEKAN
2. TERMINAL B.
TERMINAL B AKAN BERHUBUNGAN DENGAN MASSA/BODY
DENGAN TAHANAN 50 JIKA VOLTAGE RELAY DITEKAN.

JIKA PENGETESAN DAN PENGUKURAN TIDAK SEPERTI


HASIL
DIATAS BERARTI REGULATOR RUSAK / TIDAK LAYAK PAKAI

Anda mungkin juga menyukai