Q 20 gpm
V 25000 gal
Sg 0.81 ρ 50.463
μ 1.125 Cp
pump section velocity 2 ft/s table 4.13 ambil diantara 1--5
g 9.81 m/s 32.2 ft 2g
ε 0.0018 TABLE 4-3
d 2.067 Hal 138. nominal pipe size in for 2 in s
asumsi t 60 detik
2
1 (v) estimated flow velocity
"v "=(� � 8,33 ��/��� � ��)/((62,3 � �� � � �
60�/���)/144)
v= 1.912959 ft/s
Velocity head �^2/2� 0.0568232 ft
�/� 0.0008708
A (�/�)/3,7+(6,7/𝑅𝑒)
^0,9
A= 0.000920804
1/√(𝑓_𝑐 )=−4 log{�/3,7𝐷−5,02/𝑅𝑒 log𝐴 }
12.12738
fc 0.006799327
Fd 0.0271973078
hf = 4.0063343127
total friction loss pada discharge side pompa
hf = hf kerosine + hf Fluid
hf = 18.0089585322 ft fluid kerosene
∆𝑃𝑓= ℎ𝑓𝑥𝑆𝑝𝐺𝑟/2,31
∆Pf = 6.3148296152
𝐾𝑓=
𝐾�/𝑅𝑒+K∞(1+1/𝐼𝐷)
energi kinetik
p2
pump discharge pipe sezing only A baru
pipa diameter
ID in ft
A
v
velocity head
6 Re
ε/d untuk pipa 1 1/4 in ID 1,38
A
1/√(𝑓_𝑐 )=−4 log{�/3,7𝐷−5,02/𝑅𝑒 log𝐴 }
∆P psi / 100 ft
D in pipe ID in ft 1,38/12
hf total
K pipe
sum K's =
�/�𝑐+144 𝑃1/𝜌+Z1�/�𝑐+
〖� 1 〗 ^2/2�𝑐=144 𝑃2/𝜌+Z2�/�𝑐+
〖� 2 〗 ^2/2�𝑐+𝑒𝑓/�𝑐+�/�𝑐
ketika konfigurasi pipa sama, v1 = v2 dan asumsikan tidak ada heat transfer yang
bekerja pada sistem, q=w=0
pressure drop :
−∆𝑃=(𝑃1−𝑃2)=𝜌/144 (𝑍2−𝑍1) �/�𝑐+𝜌/144 𝑒𝑓/�𝑐
𝑒𝑓=(𝑓�
𝐿/𝐷+∑▒ 〖�� )�^2/2 〗
�� = 579.8885
−∆𝑃=P1−P2
−∆𝑃= 4.907045 + 6.3110144056
−∆𝑃= 11.21806 psi
144
=0,0216 ×𝑓 × 𝜌 × 𝑄^2/�^5
psi
4
ft2/s2 k tiap fitti 0.669
0.060484 lbf/in2
10 ft
3.504375 lbf/in2 static head total
-0.01991
100.2988 psig
0.007427 in2 5
1.069519 in2
1.167238 in
0.115 ft diambil dari ukuran pipa 1 1/2 velocity akan berkurang
0.010382 ft2 volumetrik 7.48 gal/ft3 0.000351
4.292515 ft/s 0.000476
0.286113 ft of fluid
32894.4 turbulen anggap 33000
0.0013
0.000828
12.34114
2.291116
0.115 ft
14.00262 ft of kerosine pipe
48.94087
Kf total + K pipe
62.94349
7