Anda di halaman 1dari 1

n Q Q eco Qdes Head η η P Energi CF

Skenario
Turbin (m3/s) (m3/s) (m3/s) (m) Turbine Generato (MW) (GWH/thn) (%)
FS Q48 2 10.77 0.82 10.77 104.37 0.94 0.97 10.00 56.45 64.4%
S.1 Q41 2 12.09 1.32 10.77 104.37 0.94 0.97 10.00 53.74 61.3%
S.2 Q48 2 11.59 0.82 10.77 104.37 0.94 0.97 10.00 56.05 64.0%
S.2.1 Q48 2 11.27 0.50 10.77 104.37 0.95 0.97 10.11 56.58 64.59%
S.2.2 Q48 2 11.27 0.50 10.77 72.27 0.95 0.97 7.00 39.44 64.32%
S.2.3 Q58 2 7.96 0.50 7.46 104.37 0.95 0.97 7.00 44.05 71.84%
S.3 Q53 2 10.46 0.82 9.64 104.37 0.94 0.97 8.95 51.61 65.5%
S.4 Q55 2 9.39 0.82 8.57 104.37 0.94 0.97 7.96 47.25 67.4%
S.5 Q48 3 11.59 0.82 10.77 104.37 0.94 0.97 10.00 56.98 65.0%

Catatan :
* Skenario S.2.1 sudah memperhitungkan loses jaringan
* Turbin tidak beroperasi total selama 73 hari/tahun, bisa dimanfaatkan untuk maintenace