Anda di halaman 1dari 4

UNIVERSITAS GORONTALO

LABORATORIUM TERPADU
Jl. Abdul Wahab, No. 247, Limboto, Gorontalo

UJI PENETRASI LAPANGAN DENGAN ALAT SONDIR


Proyek : DED Pembangunan Gedung IGD Rumah Sakit Pratama
Lokasi : Desa Tolinggula Pantai, Kecamatan Tolinggula, Kabupaten Gorontalo Utara
Titik : 1
Koordinat : 01o 01' 02.44" N dan 122o 12' 02.96" E
Tanggal Uji : 27/02/2022
Dibuat Oleh : Azhar A. Wahab, Dkk.

Kedalaman qc Lf = qf + lf Fs = Lf*Ac/As Tf = 20*Fs Tf total Rf = (Fs/qc)*100


2 2 2
(m) (kg/cm ) (kg/cm ) (kg/cm ) (kg/cm) (kg/cm) (%)
0 0 0 0 0 0 0
0.2 0 0 0 0 0 #DIV/0!
0.4 0 0 0 0 0 #DIV/0!
0.6 0 0 0 0 0 #DIV/0!
0.8 0 0 0 0 0 #DIV/0!
1 0 0 0 0 0 #DIV/0!
1.2 10 15 0.33 6.69 6.69 3.34
1.4 20 25 0.33 6.69 13.37 1.67
1.6 20 30 0.67 13.37 26.74 3.34
1.8 10 15 0.33 6.69 33.43 3.34
2 10 15 0.33 6.69 40.11 3.34
2.2 60 70 0.67 13.37 53.48 1.11
2.4 50 60 0.67 13.37 66.85 1.34
2.6 30 35 0.33 6.69 73.54 1.11
2.8 30 40 0.67 13.37 86.91 2.23
3 20 25 0.33 6.69 93.60 1.67
3.2 30 40 0.67 13.37 106.97 2.23
3.4 20 30 0.67 13.37 120.34 3.34
3.6 10 15 0.33 6.69 127.02 3.34
3.8 20 25 0.33 6.69 133.71 1.67
4 20 25 0.33 6.69 140.39 1.67
4.2 10 15 0.33 6.69 147.08 3.34
4.4 20 25 0.33 6.69 153.76 1.67
4.6 20 30 0.67 13.37 167.13 3.34
4.8 10 20 0.67 13.37 180.51 6.69
5 10 15 0.33 6.69 187.19 3.34
5.2 20 25 0.33 6.69 193.88 1.67
5.4 30 40 0.67 13.37 207.25 2.23
5.6 30 40 0.67 13.37 220.62 2.23
5.8 50 60 0.67 13.37 233.99 1.34
6 70 80 0.67 13.37 247.36 0.96
Keterangan Gorontalo, 01 Maret 2022
qc = perlawanan konus Kepala Laboratorium Terpadu
Fs = perlawanan geser lokal Univeersitas Gorontalo
Rf = angka banding geser
Tf = geseran
2
Ac = 10 cm
2 Dr. Muhammad Ramdhan Olii, ST., M.Eng.
As = 150 cm
tidak ada perlawanan konus NIDN. 0924058701

LABORATORIUM MEKANIKA TANAH-PROGRAM STUDI TEKNIK SIPIL-FAKULTAS TEKNIK-UNIVERSITAS GORONTALO


UNIVERSITAS GORONTALO
LABORATORIUM TERPADU
Jl. Abdul Wahab, No. 247, Limboto, Gorontalo

UJI PENETRASI LAPANGAN DENGAN ALAT SONDIR


Proyek : DED Pembangunan Gedung IGD Rumah Sakit Pratama
Lokasi : Desa Tolinggula Pantai, Kecamatan Tolinggula, Kabupaten Gorontalo Utara
Titik : 1
Koordinat : 01o 01' 02.44" N dan 122o 12' 02.96" E
Tanggal Uji : 2/27/2022
Dibuat Oleh : Azhar A. Wahab, Dkk.

Kedalaman qc Lf = qf + lf Fs = Lf*Ac/As Tf = 20*Fs Tf total Rf = (Fs/qc)*100


(m) (kg/cm2) (kg/cm2) (kg/cm2) (kg/cm) (kg/cm) (%)
6.2 60 70 0.67 13.37 260.73 1.11
6.4 80 90 0.67 13.37 274.10 0.84
6.6 100 110 0.67 13.37 287.47 0.67
6.8 80 90 0.67 13.37 300.84 0.84
7 100 110 0.67 13.37 314.21 0.67
7.2 70 80 0.67 13.37 327.58 0.96
7.4 70 80 0.67 13.37 340.96 0.96
7.6 110 120 0.67 13.37 354.33 0.61
7.8 80 90 0.67 13.37 367.70 0.84
8 50 60 0.67 13.37 381.07 1.34
8.2 70 80 0.67 13.37 394.44 0.96
8.4 50 60 0.67 13.37 407.81 1.34
8.6 20 30 0.67 13.37 421.18 3.34
8.8 10 15 0.33 6.69 427.87 3.34
9 10 15 0.33 6.69 434.55 3.34
9.2 20 25 0.33 6.69 441.24 1.67
9.4 10 15 0.33 6.69 447.92 3.34
9.6 20 30 0.67 13.37 461.29 3.34
9.8 20 30 0.67 13.37 474.66 3.34
10 20 30 0.67 13.37 488.03 3.34
10.2 20 30 0.67 13.37 501.40 3.34
10.4 20 30 0.67 13.37 514.78 3.34
10.6 20 25 0.33 6.69 521.46 1.67
10.8 20 30 0.67 13.37 534.83 3.34
11 10 15 0.33 6.69 541.52 3.34
11.2 40 50 0.67 13.37 554.89 1.67
11.4 40 50 0.67 13.37 568.26 1.67
11.6 40 50 0.67 13.37 581.63 1.67
11.8 40 50 0.67 13.37 595.00 1.67
12 40 45 0.33 6.69 601.69 0.84

Keterangan Gorontalo, 01 Maret 2022


qc = perlawanan konus Kepala Laboratorium Terpadu
Fs = perlawanan geser lokal Univeersitas Gorontalo
Rf = angka banding geser
Tf = geseran
2
Ac = 10 cm
2 Dr. Muhammad Ramdhan Olii, ST., M.Eng.
As = 150 cm
NIDN. 0924058701

LABORATORIUM MEKANIKA TANAH-PROGRAM STUDI TEKNIK SIPIL-FAKULTAS TEKNIK-UNIVERSITAS GORONTALO


UNIVERSITAS GORONTALO
LABORATORIUM TERPADU
Jl. Abdul Wahab, No. 247, Limboto, Gorontalo

UJI PENETRASI LAPANGAN DENGAN ALAT SONDIR


Proyek : DED Pembangunan Gedung IGD Rumah Sakit Pratama
Lokasi : Desa Tolinggula Pantai, Kecamatan Tolinggula, Kabupaten Gorontalo Utara
Titik : 1
Koordinat : 01o 01' 02.44" N dan 122o 12' 02.96" E
Tanggal Uji : 2/27/2022
Dibuat Oleh : Azhar A. Wahab, Dkk.

Kedalaman qc Lf = qf + lf Fs = Lf*Ac/As Tf = 20*Fs Tf total Rf = (Fs/qc)*100


(m) (kg/cm2) (kg/cm2) (kg/cm2) (kg/cm) (kg/cm) (%)
12.2 30 40 0.67 13.37 615.06 2.23
12.4 30 35 0.33 6.69 621.74 1.11
12.6 30 40 0.67 13.37 635.11 2.23
12.8 10 15 0.33 6.69 641.80 3.34
13 10 15 0.33 6.69 648.48 3.34
13.2 10 15 0.33 6.69 655.17 3.34
13.4 40 50 0.67 13.37 668.54 1.67
13.6 50 60 0.67 13.37 681.91 1.34
13.8 30 40 0.67 13.37 695.28 2.23
14 30 40 0.67 13.37 708.65 2.23
14.2 30 40 0.67 13.37 722.02 2.23
14.4 30 40 0.67 13.37 735.39 2.23
14.6 20 30 0.67 13.37 748.76 3.34
14.8 10 15 0.33 6.69 755.45 3.34
15 10 15 0.33 6.69 762.13 3.34
15.2 10 15 0.33 6.69 768.82 3.34
15.4 10 15 0.33 6.69 775.51 3.34
15.6 20 30 0.67 13.37 788.88 3.34
15.8 20 30 0.67 13.37 802.25 3.34
16 20 30 0.67 13.37 815.62 3.34
16.2 10 15 0.33 6.69 822.30 3.34
16.4 10 15 0.33 6.69 828.99 3.34
16.6 10 15 0.33 6.69 835.67 3.34
16.8 20 30 0.67 13.37 849.04 3.34
17 20 30 0.67 13.37 862.42 3.34
17.2 10 15 0.33 6.69 869.10 3.34
17.4 10 15 0.33 6.69 875.79 3.34
17.6 20 30 0.67 13.37 889.16 3.34
17.8 20 30 0.67 13.37 902.53 3.34
18 20 25 0.33 6.69 909.21 1.67

Keterangan Gorontalo, 01 Maret 2022


qc = perlawanan konus Kepala Laboratorium Terpadu
Fs = perlawanan geser lokal Univeersitas Gorontalo
Rf = angka banding geser
Tf = geseran
2
Ac = 10 cm
2 Dr. Muhammad Ramdhan Olii, ST., M.Eng.
As = 150 cm
NIDN. 0924058701

LABORATORIUM MEKANIKA TANAH-PROGRAM STUDI TEKNIK SIPIL-FAKULTAS TEKNIK-UNIVERSITAS GORONTALO


UNIVERSITAS GORONTALO
LABORATORIUM TERPADU
Jl. Abdul Wahab, No. 247, Limboto, Gorontalo

UJI PENETRASI LAPANGAN DENGAN ALAT SONDIR


Proyek : DED Pembangunan Gedung IGD Rumah Sakit Pratama
Lokasi : Desa Tolinggula Pantai, Kecamatan Tolinggula, Kabupaten Gorontalo Utara
Titik : 1
Koordinat : 01o 01' 02.44" N dan 122o 12' 02.96" E
Tanggal Uji : 2/27/2022
Dibuat Oleh : Azhar A. Wahab, Dkk.
qc (kg/cm2) Fs/qc (%)
0 20 40 60 80 100 120 140 160 180 200 220 240 0 5 10 15 20
0 0
0.4 Qc Tf total 0.4 Fs/qc
0.8 0.8
1.2 1.2
1.6 1.6
2 2
2.4 2.4
2.8 2.8
3.2 3.2
3.6 3.6
4 4
4.4 4.4
4.8 4.8
5.2 5.2
5.6 5.6
6 6
6.4 6.4
6.8 6.8
7.2 7.2
7.6 7.6
8 8
Kedalaman (m)

8.4 8.4
8.8 8.8
9.2 9.2
9.6 9.6
10 10
10.4 10.4
10.8 10.8
11.2 11.2
11.6 11.6
12 12
12.4 12.4
12.8 12.8
13.2 13.2
13.6 13.6
14 14
14.4 14.4
14.8 14.8
15.2 15.2
15.6 15.6
16 16
16.4 16.4
16.8 16.8
17.2 17.2
17.6 17.6
18 18
18.4 18.4
18.8 18.8
19.2 19.2
19.6 19.6
20 20
0 200 400 600 800 1000
Tf total (kg/cm)
Keterangan Gorontalo, 01 Maret 2022
qc = perlawanan konus Kepala Laboratorium Terpadu
Fs = perlawanan geser Univeersitas Gorontalo
Rf = angka banding geser
Tf = geseran

Dr. Muhammad Ramdhan Olii, ST., M.Eng.


NIDN. 0924058701

LABORATORIUM MEKANIKA TANAH-PROGRAM STUDI TEKNIK SIPIL-FAKULTAS TEKNIK-UNIVERSITAS GORONTALO