Anda di halaman 1dari 1

PERUSAHAAN LISTRIK NEGARA

PEMBANGKITAN SUMATERA BAGIAN UTARA

JOB CARD EMERGENCY

No. WO : WO979379 ULPLTA Renun #01 Shaft Seal CW Pressure Low Trip
No. Task : WT1126395 Pemulihan Unit 1

Reported By : 93161932ZY Yohanes Adi Santoso


Work Type : EM
Asset : RNUN-TA-01-PAC11AT101 RNUN TA 01 MOTOR & FILTER SHAFT SEAL
Location : 170404010205 PLTA RENUN #1 SHAFT SEAL PUMP AREA
Actual Start : Nov 15, 2021 11:06 PM
Actual Finish : 16-11-2021/15:00
Actual Labor : 16-11-2021/16:30

Isolasi dan Perhatian Keselamatan Kerja

1. MENGGUNAKAN APD
2. BEKERJA SESUAI IK

Verifikasi

Supervisor Operasi Pelepasan Sistem

Verifikasi

Supervisor KLK3

Failure Reporting

PROBLEM : SHAFT SEAL CW PRESSURE LOW TRIP

COUSE : MOTOR & FILTER SHAFT SEAL TIDAK BEKERJA SECARA NORMAL

REMEDY ; MELAKUKAN PENGGANTIAN KAPASITOR MOTOR & FILTER SHAFT SEAL

Work Order Release

Diminta Oleh

Supervisor Pemeliharaan

Verifikasi

Supervisor Operasi

Anda mungkin juga menyukai