1. TANGKI-01 (T-01)
IDENTIFIKASI
Nama Alat Tangki – 01
Kode Alat T – 01
Fungsi Menampung bahan baku Etanol
Jumlah 3 unit
DATA DESAIN
Tipe Silinder vertikal dengan ellipsoidal head
Tekanan 1 atm
Temperatur 30 oC
Kapasitas 197,2379 m3
Diameter DATA5,3222 m
MEKANIK
OD 5,3330 m
Tebal Dinding 0,0092 m
Tinggi Tangki 9,3138 m
Volume Silinder 177,5141 m3
Volume Ellipsoidal Head 19,7238 m3
Bahan Konstruksi Stainless Steel (SA-240)
2. TANGKI-02 (T-02)
IDENTIFIKASI
Nama Alat Tangki – 02
Kode Alat T – 02
Fungsi Menampung bahan baku Asam Akrilat
Jumlah 1 unit
DATA DESAIN
Tipe Silinder vertikal dengan ellipsoidal head
Tekanan 1 Atm
Temperatur 30 oC
Kapasitas 120,6799 m3
Diameter DATA4,5183 m
MEKANIK
OD 4,5218 m
Tebal Dinding 0,0018 m
DATA MEKANIK
Tinggi Tangki 7,9070 m
Volume Silinder 108,6119 m3
Volume Ellipsoidal Head 12,0680 m3
Bahan Konstruksi Stainless Steel (SA – 240)
3. TANGKI-03 (T-03)
IDENTIFIKASI
Nama Alat Tangki – 03
Kode Alat T – 03
Fungsi Menampung produk Etil Akrilat
Jumlah 1 unit
DATA DESAIN
Tipe Silinder vertikal dengan ellipsoidal head
Tekanan 1 atm
Temperatur 30 oC
Kapasitas 120,6799 m3
Diameter DATA4,5183 m
MEKANIK
OD 4,5285 m
Tebal Dinding 0,0051 m
Tinggi Tangki 7,9070 m
Volume Silinder 108,6119 m3
Volume Ellipsoidal Head 12,0680 m3
Bahan Konstruksi Carbon Steel
4. REAKTOR-01 (R-01)
IDENTIFIKASI
Nama Alat Reaktor-01
Kode alat R-01
Jenis Fixed Bed Reactor
Jumlah 1 buah
Tempat terjadinya reaksi etanol dan asam akrilat
Fungsi menjadi etil akrilat sebagai produk utama dengan
proses esterifikasi
KONDISI OPERASI
Temperatur Inlet 85 oC
Tekanan 2 bar
VESSEL
Silinder Head
51
Jenis Silinder Ellipsoidal
Material Stainless Steel 304 Stainless Steel 304
Diameter 3,692711 m 3,692711 m
Tebal dinding 0,177175 m 0,177175 m
Tinggi 11,078133 m
Volume Reaktor 131,760222 m3
KATALIS
Senyawa Resin Asam Lewatit K1431
Bentuk Gel
Volume 65,8801 m3
JAKET PENDINGIN
Jenis Pendingin Air
Volume Air Pendingin 11,1972 m3
Waktu Tinggal 60 menit
Tebal Jaket 0,0917 m
6. KOLOM DESTILASI-(KD-02)
IDENTIFIKASI
Nama /
Kode Kolom Distilasi 1 / KD - 01
Alat
Jenis Sieve Tray Column
Jumlah 1 buah
Operasi Kontinyu
Memisahkan air dari campuran output reaktor 02 (R-
Fungsi 02)
DATA DESAIN
Top Bottom
Pin 0,9117 atm 1,0637 atm
Pout 0,9112 atm 1,0260 atm
Temperatur 75,8233 C
O
101,6922 OC
KOLOM
Tinggi kolom 37,3539 m
Umpan Masuk stage ke - 66
Total Tray 78 tray
Top Bottom
ID 3,5576 m 3,6371 m
OD 3,5716 m 3,6492 m
KOLOM
Tray spacing 0,3500 m 0,3500 m
Jumlah tray 66 buah 12 buah
Tebal silinder 0,0057 m 0,0060 m
Tebal head 0,0070 m 0,0072 m
Material Carbon Steel (SA-285, Cr. C)
PELAT
Top Bottom
Downcomer
1,1922 m2 1,2461 m2
area
Active area 8,7432 m2 9,1384 m2
Hole Diameter 5,0000 mm 5,0000 mm
Hole area 0,8743 m2 0,9138 m2
Tinggi weir 12,0000 mm 12,0000 mm
Panjang weir 2,7394 m 2,8006 m
Tebal pelat 5,0000 mm 5,0000 mm
Pressure drop 29,7990 mm liquid 27,0425 mm
per tray liquid
Tipe aliran
Single pass Single pass
cairan Desain
% flooding
85 % 85 %
Jumlah hole 44.552 Buah 46.536 buah
8 CONDENSOR-01 (CD-01)
IDENTIFIKASI
Nama Alat Condensor
Kode Alat CD – 01
Fungsi Mengkondensasi produk top KD-01
Jumlah 1 unit
DATA DESAIN
Tipe Shell and Tube Heat
Exchanger Clean Coefficient (Uc) 116,0840
Btu/hr.ft .°F Design Coefficient
2
9 CONDENSOR-02 (CD-02)
IDENTIFIKASI
Nama Alat Condensor
Kode Alat CD – 02
Fungsi Mengkondensasi produk top KD-02
Jumlah 1 unit
DATA DESAIN
Tipe Shell and Tube Heat Exchanger
Clean Coefficient (Uc) 79,0135 Btu/hr.ft2.°F
Design Coefficient (Ud) 75,1068 Btu/hr.ft2.°F
Tube Side Coefficient (hio) 75,5501 Btu/hr.ft2.°F
Shell Side Coefficient (ho) 1140,4222 Btu/hr.ft2.°F
Dirt Factor (Rd) 0,00002 hr.ft2.°F/Btu
Bahan Konstruksi Stainless Steel 316
Tube Side
Panjang 12,5 ft
Outside Diameter (OD) 1 in.
BWG 18
Tube Pitch 1,25 in.
Tube Arrangement Triangular
Jumlah Pass 2
Jumlah Tube 282 tubes
Pressure drop 0,0297 psi
Shell Side
Inside Diameter (ID) 25 in.
Baffle Spacing (B) 12,5 in.
Jumlah Pass 2
Jumlah Baffle 12 baffle
Pressure Drop 0,1378 psi
HEAT EXCHANGER
Tipe Shell and Tube Heat Exchanger
Bahan Konstruksi Stainless Steel (18/8)
Overall Heat Transfer Coefficient (U) 901,4721
Tube Side Transfer Coefficient (hi) 2549,7026 W/m2K
Shell Side Heat Transfer Coefficient (hs) 8735,4047 W/m2K
Tube SideShell Side
Length 2,44 m Tipe Baffle Single Segmental
Baffle
OD 10 mm ID 349,0348 mm
ID 6 mm Baffle Space 89,4961 mm
Pitch 12,5 mm (Triangular) Passes 1
Passes 2 Jumlah Baffle 27 baffle
Jumlah Tube 440 tube 4033,198 11166,7102Pa
ΔPT 15727,6515 Pa
12. REBOILER-02 (RB-02)
IDENTIFIKASI
Nama Alat Reboiler-02
Kode Alat RB-02
Jumlah 1 buah
Operasi Kontinu
Fungsi Memanaskan keluaran bottom KD-02
HEAT EXCHANGER
Tipe Shell and Tube Heat Exchanger
Bahan Konstruksi Carbon Steel
Overall Heat Transfer Coefficient (U) 750,7011 W/m2K
Tube Side Transfer Coefficient (hi) 1503,8617 W/m2K
Shell Side Heat Transfer Coefficient (hs) 3482,5558 W/m2K
Tube SideShell Side
Length 4,88 m Tipe Baffle Single Segmental Baffle
OD 50 mm ID 459,614 mm
ID 46 mm Baffle Space 91,9228 mm
Pitch 62,5 mm (Triangular) Passes 1
Passes 2 Jumlah Baffle 53 baffle
Jumlah Tube 25 tube 4033,198 1874,885 Pa
ΔPT 181,6037 Pa
13. REBOILER-03
IDENTIFIKASI
Nama Alat Reboiler-03
Kode Alat RB-03
Jumlah 1 buah
Operasi Kontinu
Fungsi Memanaskan keluaran bottom KD-01
HEAT EXCHANGER
Tipe Shell and Tube Heat Exchanger
Bahan Konstruksi Stainless Steel (18/8)
Overall Heat Transfer Coefficient (U) 1280,8303
Tube Side Transfer Coefficient (hi) 7275,3536 W/m2K
Shell Side Heat Transfer Coefficient (hs) 3893,7825 W/m2K
Tube SideShell Side
Length 4,88 m Single Single Segmental
Segmental Baffle
Baffle
OD 40 mm 331,2358 mm 331,2358 mm
ID 36 mm 110,4120 mm 110,4120 mm
Pitch 50 mm (Triangular) 1 1
Passes 2 44 baffle 44 baffle
Jumlah Tube 18 tube 1896,218851 Pa 1896,218851 Pa
ΔPT 4,88 m
15. ACCUMULATOR-03
Nama Alat Accumulator – 02
IDENTIFIKASI
Kode Alat ACC – 02
Fungsi Menampung kondensat dari CD-02
Jumlah 1 unit
Tipe Silinder vertikal
DATA DESAINdengan ellipsoidal head
Tekanan 0,91 Atm
Temperatur 75,8233 oC
Kapasitas 0,3427 m3
DATA MEKANIK
Diameter 0,4653 m
OD 0,4731 m
Tebal Dinding 0,0039 m
Panjang 2,5593 m
Bahan Konstruksi Carbon Steel (SA-285)
IDENTIFIKASI
Nama Alat Cooler
Kode Alat C – 02
Fungsi Menurunkan temperatur produk etil akrilat
Jumlah 1 unit
DATA DESAIN
Tipe Shell and Tube Heat Exchanger
Clean Coefficient (Uc) 89,6050 Btu/hr.ft2.°F
Design Coefficient (Ud) 75,2495 Btu/hr.ft2.°F
Tube Side Coefficient (hio) 772,7209 Btu/hr.ft2.°F
DATA DESAIN
Shell Side Coefficient (ho) 101,3587 Btu/hr.ft2.°F
Dirt Factor (Rd) 0,0021 hr.ft2.°F/Btu
Bahan Konstruksi Stainless Steel 316
Tube Side
Panjang 10 ft
Outside Diameter (OD) 1 in.
BWG 18
Tube Pitch 1,25 in.
Tube Arrangement Triangular
Jumlah Pass 2
Jumlah Tube 86 tubes
Pressure drop 0,07482 psi
Shell Side
Inside Diameter (ID) 13,25 in.
Baffle Spacing (B) 6,625 in.
Jumlah Pass 1
Jumlah Baffle 12 baffle
Pressure Drop 0,05249 psi