Surge Tank Rev1 Img
Surge Tank Rev1 Img
meter
meter
meter
meter
m/det
meter
meter
m/det.2
meter
detik
kW
rpm
kg-m2
#2.Kriteria No.2
Lmaks.=3.14*Hn*Te / V
= 1358.46 meter
(perlu digunakan surge tank)
#3.Kriteria No.3
Kenaikan rpm > 45 %
(a) TK = 0.25 + Tf
(b) Tm =( GD 2 * n^ 2)/(3.6*10^5*Pr)
(c) Tk/Tm
(d) ns
=
=
=
=
=
0.25+5
5.25 detik
(74593*750^2)/((3.6*10^5*18962.149248))
6.15 detik
5.25/6.1
0.85
=
157.2 kW-m
=
31.781 %
= (2250*1.9)/(9.81*137*5)
=
0.64 detik
=
0.64/5
=
0.127
= 31.78*(1+0.13)
=
35.8 %
(tidak perlu surge tank)
#4.Kriteria N0.4
Kenaikan tekanan > 50
WaterStartTime,Tw = (LV)/(gHT)
=
=
^2
= (0.64/2)*(0.64+(0.64^2+4)^0.5)*100
.H/ H = Tw/2{Tw + (Tw +4)^0.5}
=
86.99 %
(perlu digunakan surge tank)
3.3 Perhitungan untuk menghitung tinggi Jagaan
3.3.1.BerdasarBuku:HYDROELECTRICSTATIONS,I.ILYNYKH,hal.143146
Data disain
A = Luas pipa
L = Panjang pipa
c = faktor losses
Ho= head turbin
Qo = debit pada kondisi steady
A2 = luas surge tank
g = perc. Gravitasi
L = panjang pipa
A = luas pipa
=
=
=
=
=
=
=
=
=
9.6
2000
0.1
123
18.1
490.6
9.8
2000.0
9.6
m2
meter
meter
m3/det
m2
m/det.2
meter
m2
4.89 m
4.46 m
(Hf*((As*g)/(L/A))^0.5)/Qo
(0.11*((127.51*9.81)/(2000/9.62))^0.5)/18.08
0.015 meter
losses pada pipa + (Vo2/2g)
0.1+0.02
0.114 meter
1.88/(2*9.81)
0.096 meter
0.02 meter