Tampak Transparan
Power distribution unit ( PDU ), 6 Stop Kontak VDE Standard, dengan mempunyai Proteksi
Terhadap Petir 3,5 k.a.,Over Current 16A ,Spike,dan dilengkapi dengan saklar berindikator
Lampu.
Variasi Warna
Black
Order No
RU
External
Width(mm)
Overall
Height(mm)
External
Depth(mm)
Internal
Depth(mm)
Weight
(kg)
CRS 20U-900-19
20
600
1060
900
720
100
CRS 30U-900-19
30
600
1510
900
730
130
CRS 42U-900-19
42
600
2040
900
730
162
CRS 45U-900-19
45
600
2170
900
730
171
CRS 42U-1100-19 42
600
2040
1100
930
180
CRS 45U-1100-19 45
600
2170
1100
930
191
CRS 42U-1100-24 42
800
2040
1100
930
198
CRS 45U-1100-24 45
800
2170
1100
930
209
Grey
02
Standard Supply 19 to 24
03
New Generation Network ( NGN ) Cabinet Type Heavy Duty Close Rack
19 to 26 HEAVY DUTY Close Rack Cabinet
Spesifikasi
Enclosure racking system terbuat dari Galvanis Metal, Cold Steel
(SGHC) dan painting Finshing Powder Coating.
Top Cover Cable Way ( 4 lubang ), sudah di persiapkan untuk
pemasangan Cable Ladder atau Tray pada sistem pemasangan
Data Center dan dengan acuan NGN Standard.
Pintu depan (Single dan Double) dengan kaca Tempered atau
Perforated Door dengan Swing handle dan Locking System Dirak
buatan Jerman.
Pintu samping dengan Cylinder Key lock dan termasuk juga Slide
Latch untuk setiap kunci pintu samping panels lift samping mudah
untuk di akses.
Pintu belakang (Single dan Double) Perforated Metal Door, 60%
perforated frame dengan diameter lubang 3mm, di lengkapi dengan
silinder lock Dirak buatan Jerman.
Lebar 800 mm, dan Panjang 1100 mm dengan 4 Galvalum Vertical
Frame dapat terpasang dari 19 sampai 26.
Diseluruh akses cabinet dilengkapi dengan Fastening Down Holes di
frame bagian bawah dengan Cable Way untuk melindungi kabel dan
mempermudah dalam instalasi.
Grounding System,Cable Way dan Cabinet Lamp sudah tersedia.
Grey
Black
Order No
04
RU
CRH 45U-1100-24 45
External
Overall
External
Internal Weight
Width(mm) Height(mm) Depth(mm) Depth(mm) (kg)
800
2210
1100
930
259
Termasuk di dalamnya:
Termasuk di dalamnya:
Telco Rack
Server Rack
Fan
Vertical Cable
Manager
(Optional)
Fortuna Swinghandle
Grounding Unit
05
Order No
RU
External
Width(mm)
Overall
Height(mm)
External
Depth(mm)
Internal
Depth(mm)
Weight
(kg)
ORH 25U-19
25
600
1400
20
ORH 40U-19
40
600
2050
25
ORH 45U-19
45
600
2150
26
Grey
Black
06
Grey
Black
Wallmount Cabinet
Spesifikasi dan Standard Supply
l
b
u
Do
r
o
o
D
RU
External
Width(mm)
WRS-8U-470-19 DD
600
440
470
360
35
600
600
470
360
42
WRS-12U-470-19 DD 12
Overall
Height(mm)
External
Depth(mm)
Internal
Depth(mm)
Weight
(kg)
WRS-15U-470-19 DD 15
600
750
470
360
52
WRS-15U-600-19 DD 15
600
750
655
540
55
Grey
Black
Residential Cabinet
Spesifikasi dan Standard Supply
Terbuat ColdSteel SPCC-SD
Pengecatan dengan sistem Powder Coating
Fan 220V 60 CFM & Guard
Kunci Silinder Dirack (Jerman)
20 buah Cagenut
Pemasangan sebagai Consolidation Point
Terdapat Backbone untuk pemasangan pada area yang sempit.
Sebagai Access antar gedung atau Box perangkat elektronik pada
sistem pemasangan apartement
Order No
RU
Residential Boxes
External
Overall
External
Internal Weight
Width(mm) Height(mm) Depth(mm) Depth(mm) (kg)
500
700
244
220
07
Ceiling Cabinet
Spesifikasi
dan Standard
Supply
Terbuat dari Cold Steel SPCC-SD
Pengecatan dengan sistem Powder
Coating
Handle dish (Jerman)
Fan 220V 25 CFM & Guard
(garansi 18 bulan)
Telescopic cover stay
Wing Handle (Germany)
Support 8U System.
Order No
RU
Ceiling Boxes
External
Overall
External
Internal Weight
Width(mm) Height(mm) Depth(mm) Depth(mm) (kg)
624
300
644
390
08
Spesifikasi
Material: Mill Finish 6065-T6 aluminum.
cUL Certified.
NEMA VE1 Load Class 12B.
Spesifikasi
Material: 16 gs. Tubular Steel.
Tubular powder coat.
Stringer dimensions: 0.375 W x 1.5 H.
Rung Spacing: 9.0.
Kapasitas berat: 45 lbs./kaki.
09
Cabinet Accessories
Fortuna Ventilation System
10
Power dist, dengan soket (vertikal atau horizontal) Gaya Eropa dengan switchand LNG
menggelora perlindungan.
U
1
1
Socket
6
8
Order Code
VP-HP6.E
VP-HP8.E
Color Depth
Order Code
Black 48 Port
WM 48
Black FO
WMFO
Black 24 Port
WM 24
Order Code
20U
CT-20U
40U
CT-40U
Depth
Order Code
4EA/Pack
CS CR
Depth
Order Code
6 x 15
CN-M6x15
Order Code
Order Code
SFCR-25CFM
SFCR-195CFM
SFCR-92CFM
Depth(mm)
Order Code
500
FSCR-500
600
FSOR-600
680
FSCR-680
800
FSCR-800
19 Cantilever Shelf
19 Flatshelf for
Wallmount Rack
Depth(mm)
Order Code
360
CSWM-360
500
CSCR-500
0.5 300
Depth(mm)
Order Code
500
PFCR-500
Depth(mm)
Order Code
FSWR-300
19 & 24 Telescopic
Drawer Swing/ Pivot
Type for Close Rack
U
Depth(mm)
1.5 500
Order Code
TDCR-500
11
Spesifikasi
.
Memonitoring total output PDU hingga
per Outlet.
Tersedia data KWH.
Mendeteksi temperatur dan kelembaban.
Pengendalian outlet jarak jauh.
1 phase (tahap) dan 3 phase PDU.
10AMP hingga 32 AMP.
100V hingga 240V dan 400Vs.
Basic PDU
Features
Pemasangan pada rack, Horizontal atau vertical.
Remote Power Monitor, dapat di upgrade.
Proteksi, Circuit Breaker.
Paket, Mounting Bracket.
Metered PDU
PDU yang terintegrasi dengan fasilitas Pengukur Digital.
Dapat bekerja sendiri atau digabung dengan Cabinet
Monitor untuk memantau pemakaian daya.
Features
Current Meter, Digital True RMS Current meter.
Pemasangan pada Rack, Horizontal atau vertical.
Remote Power Monitor, dapat di upgrade.
Audible Alarm, 2 Tahap, Peringatan and Overload.
Proteksi, Circuit Breaker.
Paket, Mounting Bracket.
12
Monitored PDU
PDU yang dapat memantau pemakaian daya dari semua
pengukur arus digital maupun melalui jaringan.
Features
Current Meter, Digital True RMS Current meter.
Pemasangan Rack, Horizontal atau vertical.
Power Monitor, Meter, Web SNMP, Paket Software.
Audible Alarm, 2 Tahap, Peringatan dan Overload.
Peringatan Pemberitahuan, E-mail, Trap, audible Alarm.
Proteksi, Circuit Breaker.
Paket, Mounting Bracket; User manual; Amazing PDU Sofware
Switched PDU
PDU yang bukan hanya dapat memantau daya juga dapat
disambung maupun dimatikan melalui jaringan dan dapat
mengontrol penuh terhadap PDU lain.
Features
Current Meter, Digital True RMS Current meter.
Pemasangan pada Rack, Horizontal atau vertical.
Power Monitor, Meter, Web SNMP, Paket Software.
Power Control, Web SNMP.
Audible Alarm, 2 Tahap, Warning danOverload.
Penringatan Pemberitahuan, E-mail, Trap, audible Alarm.
Proteksi Circuit Breaker.
Paket, Mounting Bracket; User manual; Amazing PDU Sofware
RPM PDU
Fungsi PDU berbasis web Spesial PDU penuh dari IP base
adalah program kontrol ON/OFF, Kontrol ON/OFF telepon,
temperatur dan kelembaban, penghentian komputer
berbasis linux maupun windowsdll
ATS PDU
Menyediakan arus AC yang lebih banyak untuk
dihubungkan dengan perangkat. Jika arus utama AC gagal,
maka secara otomatis switch akan berpindah ke sumber
arus alternatif.
13
Kartu garansi
Sertifikat QC
QC Before Assembling
QCAfter Assembling
Serial Number
14