Kolom Distilasi
P-35
18
Heater
P-36
17
Orifice
Data Perancangan:
F = 23551,7 kg/jam
Tin = 311 K
𝐹 𝑚3 𝑚3
𝑄 = = 30122,93 = 8,3674
𝜌 𝑗𝑎𝑚 𝑠
∆𝑃
𝑃𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑙𝑜𝑠𝑠 = × 100% = 95%
𝑃𝑖𝑛
a. Luas penampang
𝐴𝑖 = 𝜋 × 𝑟𝑖 2
Maka:
𝑄
𝑣𝑖 =
𝐴𝑖
Maka:
𝑚
𝑣1 = 25,8907
𝑠
𝑚
𝑣2 = 41965,4
𝑠
c. Coefficient of discharge
ρvD 4F
NRe = = = 174192,2
μ πμD
91.71β2.5
Cd = 0.5959 + 0.0312β2.1 − 0.184β8 + = 0,5959
NRe0.75
∆𝑃
𝑌 = 1 − (0.41 + 0.35𝛽 4 ) = 0,721786
𝜒𝑃1
e. Flow coefficient
Cd
K= =0,5959
√(1−β4 )
Nilai K juga dapat diperoleh dari grafik berikut:
f. Pressure drop
1
∆𝑃 = × 𝜌 × 𝑣12 × 𝐾 = 156,1551 𝑝𝑠𝑖
2
g. Suhu keluaran
𝐾−1
𝛼= = −0,67813
𝐾
Maka:
𝑃𝑜𝑢𝑡 𝛼
𝑇𝑜𝑢𝑡 = 𝑇𝑖𝑛 × ( ) = 5𝑜 𝐶 = 278𝑜 𝐾
𝑃𝑖𝑛