Anda di halaman 1dari 4

PT.

SAKURA ELEVATOR INDONESIA CORP


Gedung Metro Sunter Lt.3 Jln. Danau Sunter Utara Blok A2
Phone : (62)-21-29562206 Fax : (62)-21-29461007

Kepada Yth :
QUOTATION
PT. SINAR TIMUR DAYACIPTA
Date : Mei 24, 2018
Jl. Lingkar Selatan No. 88, Kampung Baru Asih, Muncul
Serpong Tangerang Selatan
No : SKQT-1805K-24
Lokasi : Serpong Tangerang Selatan

PENAWARAN HARGA PENGADAAN & PEMASANGAN LIFT


Dengan Hormat,

Sesuai dengan pertemuan kita mengenai pengadaan dan pemasangan lift SAKURA, untuk proyek di atas, mohon
perkenankan kami untuk menyampaikan penawaran sebagai berikut :

DESCRIPTION QTY UNIT PRICE SUB TOTAL

1 Passenger Lift 1 SET IDR 572.000.000 IDR 572.000.000


Kap : 15 Org/1.000 Kg
Lantai : 3 stops/ 3 openings,
Machine Roomless
Include :
1. ARD (Automatic Rescue Device)
2. Infrared Curtain door

2 Jasa Instalasi, Test Commisioning 3 Lantai / 1 SET IDR 30.000.000 IDR 30.000.000
3 stops

Sub Total IDR 602.000.000

PPN 10% IDR 60.200.000

TOTAL AMOUNT IDR 662.200.000

Harga penawaran di atas adalah berdasarkan nilai tukar USD terakhir dengan toleransi +/-5%, apabila nilai tukar
diluar batas toleransi, maka kami berhak melakukan penyesuaian sesuai keadaan nilai tukar terbaru.
Harga diatas tidak termasuk pengerjaan sipil.
Harga diatas sudah termasuk PPN 10%

KETENTUAN PEMBAYARAN

PENGADAAN DAN PEMASANGAN


30% Non refundable DP 1 (down payment) dibayarkan saat PO / SPK

50% Non refundable DP 2 (down payment) disaat Material Dikapalkan

15% Dibayarkan pada saat Material on Site

5% Dibayarkan pada saat serah terima.

SAKURA ELEVATOR JAPAN Co.,Ltd.


TTD-BLDG, 1-2-18, MITA, MINATOKU, TOKYO, 108-0073, JAPAN www.sakuraelevator.co.id
PT. SAKURA ELEVATOR INDONESIA CORP

Brand SAKURA® JAPAN Technology


TYPE

Type of Elevator Passenger Lift Type

Elevator Type PS1.000-CO : 3/3

Capacity (kg) 1.000

Person 15 Person

No of Stops / Floors 3 stops/ 3 openings


SPECIFICATION

Floor Served 1-3

Speed (meter per menit) 60

Power Capacity (kw) -

Power Supply 370V Triple Phase 50 Hz

Lighting 220V Single Phase 50 Hz

Control AC-VVVF

Operation System Simplex

Country Of Origin Taiwan

Min Hoistway Size (mm) Width x Depth 2350 x 1900


HOISTWAY

Over Head (mm) 4200

Pit Depth (mm) 1550

Travel - Meter

Counter Weight Position -

Machine Room Location Machine Roomless

Door Type Center Opening


CABIN

Door Opening (mm) W x H 900 x 2100

Car Size (mm) W x D x H 1600 x 1500 x 2300

CABIN SPECIFICATION

Ceiling Type : Standard type Cabin Enclosed : Pattern Steel Finish

Lighting : LED lighting Cabin Door : Pattern Steel Finish

Ventilation : Strimelined conditioning Landing Door : Pattern Steel Finish

Window : N/A Floor Type : PVC Anti Sliding Floor Tiles

Handrail : include for standard Operation Panel : HS06-EP02/CS06-EP02 /


Type /Material Pattern Stainless Steel

Display / Character : Standard Type /1.2.3 Jamb : Pattern Steel / Narrow Jamb

FEATURE (INCLUDED):

1.Cage complete set with standard accessories


2. Other Standard Features: Alarm Bell, Emergency light, Full Load By Pass Detection, Next
Landing Facility, Repeat Door Open and Close, Car Ventilation and Light automatically shut off, Mechanical Safety Edges, Safety
Gear (Brake), OverSpeed Governor, Car Top Inspection Box, DC/DO/Alarm/Hold Button, Anti-Nuisance Operation, Arrival Car Gong

www.sakuraelevator.co.id
PT. SAKURA ELEVATOR INDONESIA CORP

STANDARD FUNCTION INCLUDE

In case of a power failure and the car stops between floors, on restoration of
Power-on Re-leveling power, the car will move to the nearest floor ✔
In the event of power failure, emergency lighting in the car will automatically
Emergency Car Lighting turn on. ✔
When switching from inspection mode back to normal operation, the door will
Door Safety Detector open and close to detect any obstructions. If detected the Elevator will not ✔
return to normal operation until the fault has been rectified

When the Elevator electrical safety circuit is open the Elevator will immediately
Safety Circuit Detector stop until the fault is rectified. ✔

Cancel Error-Carry If someone pushed the wrong button, just push it once more and it would be
Function cancelled. ✔

Automatic Turn Off Control panel will be turn off automatically in case there is no hall or car call to
Control Panel save energy. ✔
Fan will be turn off automatically in case there is no hall call or car call to save
Automatic Turn Off Fan energy. ✔
Car illumination will turn off automatically in case there is no hall call or car call
Automatic Turn Off light to save energy. ✔
The Elevator will return to the designated floor to stand by after responding to
Elevator Homing all calls. ✔
For instance, when a car call is being called to 8th floor and if the 8th floor¡¯s
Auto Time-Extending hall call is being called at the same time, the door open timing will automatically
Door Holding Function extend 3-5 sec from the original door open timing which allows ample time for ✔
passengers to enter and exit the Elevator.

If an obstacle prevents the door from closing, the door will repeatedly open and
Door Nudging Feature close until the object is removed. ✔
Mounted on the leading edge of the car door, causes the door and landing
Door Reversal Device doors to reopen if obstructed. ✔
When overload is detected it will send a warning signal and only when the load
Over-Load Device is reduced to safe parameters will the elevator resume service. ✔
When the Elevator detects that more car calls have been registered than the
Anti-Nuisance measured weight in the car the control panel will cancel all the car calls. ✔
When the car completes the last upward or downward direction change, the
Wrong Direction Car Call system will automatically detect and cancel the wrong direction can still stored
Back Cancelling ✔
in the memory.

When a car stops between floors due to mechanical malfunction, it will descend
Safety Operation to the nearest floor at a low speed and hold the doors open after checking all ✔
safety measures.

The device can cause the door to return to the fully open position, should the
Safety Door Edge door encounter a person or obstacle while closing. ✔
Though interphone service, passengers in the car are able to communicated
Intercom System with the control room. ✔
In the case of power failure, the ARD will pick up the signal and send the
Auto Rescue Device Elevator car to the nearest landing and open the door, allowing the passenger
(ARD) ✔
to exit the Elevator car.

www.sakuraelevator.co.id
PT. SAKURA ELEVATOR INDONESIA CORP
Gedung Metro Sunter Lt.3 Jln. Danau Sunter Utara Blok A2
Phone : (62)-21-29562206 Fax : (62)-21-29461007

LINGKUP PEKERJAAN

Lingkup perkerjaan pihak kontrak dan Owner (Terlampir)

JADWAL PENGADAAN

1 Produksi dan Pengiriman 3 Bulan

2 Instalasi dan Testing Commisioning 1 Bulan

Total 4 Bulan (terhitung sejak DP-1 diterima dan Approval drawing


disetujui)

CATATAN

a Bahan-bahan untuk pemasangan elevator sudah termasuk dalam penawaran tersebut.

b Barang-barang tersebut akan dipetikan khusus sesuai standard pabrik

c Jaminan atas kesalahan bahan dan pembuatan pabrik (workmanship) adalah 12 (dua belas) bulan sejak barang
dikapalkan apabila pemeliharaannya dilakukan oleh kami.

d Penawaran ini berlaku 1(satu) bulan sejak tanggal surat penawaran ini dan harus ada penegasan dari setelah
tanggal tersebut diatas.

Semoga penawaran harga ini dapat memenuhi kebutuhan Bapak/Ibu, dan atas perhatiannya kami ucapkan terima
kasih. Bila diperlukan keterangan yang lebih lengkap kami selalu bersedia memberikan penjelasan.

Hormat Kami,

Kalyana Wira
(Sales Department)
Hp.081905076621
Untuk Pembayaran / Down Payment (DP)
harap ditransfer ke Rekening :

Bank BCA, KCP MAL SUNTER


PT SAKURA ELEVATOR INDONESIA
428-3009-168

SAKURA ELEVATOR JAPAN Co.,Ltd.


TTD-BLDG, 1-2-18, MITA, MINATOKU, TOKYO, 108-0073, JAPAN www.sakuraelevator.co.id