Kronologi terjadi nya problem w/ top drive auxiliary not fungtion

extend,link,float

PADA HARI INI SELASA 16 MEI 2023 SAYA YANG BERTANDA TANGAN DI BAWAH INI

NAMA : YULIAN PUTRA SANDI

JABATAN : TEKNISI TOP DRIVE

BADGE : 210953

PADA HARI SELASA 16 MEI 2023 JAM 14.00

PADA SAAT MELAKUKAN FUNTION TEST EQUIPMENT RIG UNTUK PRIPARE SPUT IN DRILLER
MEMBUNYIKAN KLAKSON 4X KEBETULAN SAAT ITU SAYA BARU BERISTHIRAHAT KARENA HABIS BEKERJA
DAN BARU SIAP MENGANTI SAVER SUB DAN HOSE 3/4 ‘ PANJANG 75 FEET, LALU SAYA BERGERAK
MENUJU KE ARAH DRILLER CONSUL, DRILLER MENGATAKAN KEPADA SAYA BAHWASAN NYA LINK
EXTEND DAN FLOAT TIDAK BISA BERFUNGSI, DAN SAYA MELAKUKAN TEST PADA BARANG TERSEBUT
DAN LANGSUNG MENCOBA MELAKUKAN PADA PERBAIKAN, KEMUDIAN SAYA MENCOBA MELAKUKAN
RISET PADA HPU, DAN SAYA COBA HIDUPKAN KEMBALI JUGA TIDAK BERFUNGSI, STEP BERIKUT NYA
SAYA CHECK KOMUNIKASI PADA DRILLER CONSUL KE PANEL HPU BERFUNGSI KARENA COMUNIKASI
PADA HPU UNTUK EXTEND LINK DAN FLOAD KALO DI PERINTAH PADA POSISI ON, STEP BERIKUT NYA
MENCOBA MELAKUKAN PENGECEKAN PADA HPU KE ROBOTIK TOP DRIVE, SAYA MENGECHEK CABLE PIN
37 SATU PERSATU MENGUNAKAN MULTI STETER DAN CABLE TIDAK ADA SATU PUN YANG TERPUTUS
STEP BERIKUT NYA SAYA MELAKUKAN TEST MANUAL PADA LINK DENGAN CARA MENEKAN TOMBOL DI
TENGGAH DRIRECTIONAL VALVE DAN SAYA LIHAT DIRECTIONAL VALVE SUDAH TIDAK BEKERJA, LALU
SAYA MENGHUBUNGI SUPERVESOR SAYA PAK JONSON HUTAPEA DAN SAYA MENJELAKAN APA YANG
SUDAH SAYA KERJAKAN MENCOBA MELAKUKAN PERBAIKAN, LALU SUPERVESOR DATANG MENCOBA
MELAKUKAN PERBAIKAN STEP BY STEP, DAN SUPERVESOR MELAKUKAN PERGANTIAN VALVE
DIRECTIONAL, 3 POS, 4-WAY DO 3 24 VDC DENGAN PART NUMBER P 12422 DENGAN YANG BRAND
NEW

DEMIKIAN LAH KRONOLOGI INI SAYA BUAT