Fluida panas :
Tekanan : 8,48 atm
Suhu masuk, T1 = 373,15 K = 100 oC
Suhu keluar, T2 = 313,15 K = 40 oC
Komponen Mr kmol/jam kg/jam xmass
O2 32 0,642 20,556 0,001
C2H4 28 771,701 21607,631 0,962
C2H6 30 0,080 2,398 0,000
CO2 44 19,090 839,953 0,037
C4H6O2 86 0,016 1,337 0,000
H2O 18 0,011 0,197 0,000
CH3COOH 60 0,013 0,762 0,000
Total 791,552 22472,834 1,000
Langkah Perhitungan :
1. Beban panas
2. Media pemanas
3. Beda suhu rerata
4. Koefisien perpindahan panas
5. Alat penukar panas
6. Route fluida
7. Koefisien hi, hio, ho, Uc
8. Factor Pengotoran (Rd)
9. Pressure drop
1. Beban Panas
Beban panas untuk menurunkan suhu embunan
Dihitung dengan persamaan :
Qt = ΣVi cpgi ( T1 - T2)
Keterangan :
Cpgi : kapasitas panas masing-masing komponen pada fase gas (kJ/kgK)
Qt : beban panas untuk menurunkan suhu embunan (kJ/jam)
T1 : suhu fluida paanas masuk (K)
T2 : suhu fluida panas keluar (K)
Vi : kecapatan massa masing-masing komponen pada fase gas (kg/jam)
𝑚air=𝑄𝑡𝑜𝑡𝑎𝑙/(𝑐𝑝𝑎𝑖𝑟(𝑡2−𝑡1))
kJ
347950,408
jam kg
mair = =8312,208
kJ jam
4,186 x ( 313 ,15−303 ,15 ) K
kgK
Bilangan Reynold
2
0,0148 m x 970,557 kg/m s
ℜ=id .> ¿ = −4
=19633,178 ¿
visc 7 ,33 x 10 kg /ms
Koefisien perpindahan kalor
4 .2 (1 . 35+0 . 02 tav ) vlin 0 . 8 (towler dan Sinnot,hal 827)
hi=
Id 0 . 2
0,8
4 , 2 x ( 1, 35+0 , 02 x 308 , 15 K ) x 2,303 KJ
hi= =142,808
0,01480 , 2 m2 sK
Id KJ 0,0148 m kJ
hio=hi x =¿ 142,808 2 x =111,200 2
Od m sK 0,019 m m sK
Selongsong : fluida panas
Luas aliran (as)
'
Ids. C . B
as=
Pith
keterangan :
as: luas aliran (m2)
B : jarak antar baffle (m)
C’: clearance (m)
Pitch : pitch (m)
Jarak buffle (B) :
Ids
B= =0,102 m
5
Clearance (C’)
Pitch – OD = 0,0254 m – 0,0191 m = 0,0064 m
'
Ids. C . B 0 ,508 m x 0,102 m x 0,0064 m
as= =¿ =0,013 m2
Pith 0,0254 m
kecepatan massa umpan:
kg 1 jam
22472,834 x
kec massa fluida panas jam 3600 detik
Gs= =
as 0,013 m
2
2
¿ 483,791 kg /m s
Suhu Rerata (Tav)
T 1+ T 2 409 , 25 K + 323 ,15 K
Tav= = =366 , 20 K
2 2
Sifat Fisis Komponen pada suhu 366,20 K
µ Kth Cp rho
Komponen Mr x
[kg/ms ] [kJ/msK] [kJ/kmolK] [kg/m3]
O2 32,00 0,001 2,349,E-05 3,099,E-05 0,935 264,427
C2H4 28,00 0,975 1,228,E-05 2,879,E-05 1,765 192,399
C2H6 30,00 0,000 1,135,E-05 3,172,E-05 2,035 186,732
CO2 44,00 0,024 1,795,E-05 2,258,E-05 0,920 428,419
C4H6O2 86,00 0,000 9,642,E-06 1,541,E-05 1,329 357,326
H2O 18,00 0,000 1,181,E-05 2,443,E-05 1,892 407,558
CH3COOH 60,00 0,000 8,705,E-06 7,865,E-08 1,219 402,443
Total
x kth x µ x cp x rho
2,515,E- 0,00
08 1,906,E-08 1 0,215
2,807,E- 1,72
05 1,197,E-05 1 187,574
3,204,E- 0,00
09 1,146,E-09 0 0,019
5,444,E- 0,02
07 4,330,E-07 2 10,332
3,027,E- 0,00
10 1,894,E-10 0 0,007
3,371,E- 0,00
10 1,630,E-10 0 0,006
1,262,E- 0,00
12 1,397,E-10 0 0,006
2,864,E- 1,74
05 1,242,E-05 4 198,159
Bilangan Reynold
2
De . Gs 0,018 m x 483,791 kg/m s
ℜ= = −5
=722075,726
visc 1,242 x 10 kg /m s
Bilangan Prandtl
CpavgVisc
Pr=
kth
Kj −5
1,744 x 1,242 x 10 kg /m s
Kg K
Pr= =0,756
−5 Kj
2,864 x 10
msK
kth
ho=0 , 36 ( )Re0 ,55 x Pr1 /3
De
ho = 0,845 kJ/m2 s K
kJ kJ
111,200
2
x 0,845 2
hio . ho m sK m sK 2
Uc= = =0,839 kJ /m sK
hio +ho kJ kJ
111,200 2 +0,845 2
m sK m sK
8. Faktor Pengotor
2
1 1 1 1 m sK
Rd= − = − =4,407
Ud Uc 0,178 0,839 kJ
Rd min total = 0,3527 m2 s K / kJ
9. Pressure drop
a. Selongsong
De : 0,018 m
Gs : 483,791 kg/m2s
Ids : 0,508 m
ρf : 198,159 kg/m3
Jumlah baffle
L 7,3152 m
( N +1 )= = =72
B 0,102m
Faktor Friksi (f)
0 .264
f =0 . 0035+
Re0 . 42
f = 0,0044
f ( N +1 ) Gs2 Ids
Δ Ps=
2 ρf De
ΔPs = 5142,274 Pa = 0,051 atm
10
ΔPs max = = 0,6803 atm
14 , 7
b. Pipa
L : 7,3152 m
Gs : 970,557 kg/m2s
Id : 0,0148 m
ρair : 421,307 kg/m3
np : 2
Faktor Friksi (f)
0 . 125
f =0 . 0014+
Re0. 32
f = 0,0067
4 f Gt 2 L np
Δ Pt =
2 ρ air Id
ΔPt = 15,192 Pa = 1,499 x 10-4 atm
10
ΔPt max = = 0,6803 atm
14 , 7
Kesimpulan Cooler (CL-07)