Anda di halaman 1dari 15

i

TESIS

MANAJEMEN PEMELIHARAAN TRANSFORMATOR
TEGANGAN MENENGAH BERBASIS ANALISIS
KANDUNGAN GAS TERLARUT (DGA)
























I GUSTI NGURAH SEGARA PUTRA
NIM 0991761023









PROGRAM MAGISTER
PROGRAM STUDI TEKNIK ELEKTRO
PROGRAM PASCASARJANA
UNIVERSITAS UDAYANA
DENPASAR
2013
ii

MANAJEMEN PEMELIHARAAN TRANSFORMATOR
TEGANGAN MENENGAH BERBASIS ANALISIS
KANDUNGAN GAS TERLARUT (DGA)










Tesis untuk Memperoleh Gelar Magister
pada Program Magister, Program Studi Teknik Elektro,
Program Pascasarjana Universitas Udayana










I GUSTI NGURAH SEGARA PUTRA
NIM 0991761023


PROGRAM MAGISTER
PROGRAM STUDI TEKNIK ELEKTRO
PROGRAM PASCASARJANA
UNIVERSITAS UDAYANA
DENPASAR
2013
iii

Lembar Pengesahan



TESIS INI TELAH DISETUJ UI
TANGGAL 13 DESEMBER 2013







Pembimbing I, Pembimbing II,






Prof.Ir.I.A.Dwi Giriantari,MEngSc.,PhD Wayan Gede Ariastina,ST,MEngSc.,PhD
NIP. 196512131991032001 NIP. 196904131994121001







Mengetahui






Ketua Program Studi Magister Teknik Elektro Direktur
Program Pascasarjana Program Pascasarjana
Universitas Udayana Universitas Udayana






Prof.Ir. I.A.Dwi Giriantari,MengSc.,PhD Prof.Dr.dr.A.A.Raka Sudewi,Sp.S(K)
NIP. 196512131991032001 NIP. 195902151985102001

iv

Tesis Ini Telah Diuji pada
Tanggal 13 Desember 2013
Panitia Penguji Tesis Berdasarkan SK Rektor Universitas Udayana,
No : 3341 / UN 14.4 / HK / 2013 , Tanggal 11 Desember 2013

Panitia Penguji Hasil Penelitian Tesis adalah:
Ketua : Prof.Ir. I.A.Dwi Giriantari,MEngSc.,PhD
Anggota :
1. Wayan Gede Ariastina,ST,MEngSc.,PhD
2. Prof.Ir. Rukmi Sari Hartati,MT.,PhD
2. I Nyoman Satya Kumara,ST.,MSc.,PhD
3. Ir. Linawati, MEngSc.,PhD























v

SURAT PERNYATAAN BEBAS PLAGIAT

Saya yang bertanda tangan dibawah ini ,
Nama : I Gusti Ngurah Segara Putra
NIM : 0991761023
Program Studi : Magister Teknik Elektro
J udul Tesis : Manajemen Pemeliharaan Transformator Tegangan
Menengah Berbasis Analisis Kandungan Gas Terlarut
(DGA)

Dengan ini menyatakan bahwa karya ilmiah Tesis ini bebas plagiat.

Apabila di kemudian hari terbukti plagiat dalam karya ilmiah ini, maka saya bersedia
menerima sanksi sesuai peraturan Mendiknas RI No.17 Tahun 2010 dan Peraturan
Perundang-undangan yang berlaku

Denpasar, 13 Desember 2013
Yang membuat pernyataan



I Gusti Ngurah Segara Putra




vi

UCAPAN TERIMA KASIH


Pertama-tama perkenankanlah penulis memanjatkan puji syukur ke hadapan
Ida Sang Hyang Widhi Wasa/ Tuhan Yang Maha Esa, karena hanya atas asung wara
nugraha-Nya/kurnia-Nya, tesis ini dapat diselesaikan.
Pada kesempatan ini perkenankanlah penulis mengucapkan terima kasih
yang sebesar - besarnya kepada Prof. Ir. I.A.Dwi Giriantari ,MEngSc.,PhD,
pembimbing I yang dengan penuh perhatian telah memberikan dorongan, semangat,
bimbingan, dan saran selama penulis mengikuti Program Magister, khususnya dalam
penyelesaian tesis ini. Terima kasih sebesar-besarnya pula penulis sampaikan
kepada Wayan Gede Ariastina,ST.,MEngSc.,PhD , Pembimbing II yang dengan
penuh perhatian dan kesabaran telah memberikan bimbingan dan saran kepada
penulis.
Ucapan yang sama juga ditujukan kepada Rektor Universitas Udayana Prof.
Dr.dr. Ketut Suastika,Sp.,PD-KEMD atas kesempatan dan fasilitas yang diberikan
kepada penulis untuk mengikuti dan menyelesaikan pendidikan Program Magister di
Universitas Udayana. Ucapan terima kasih ini juga ditujukan kepada Direktur
Program Pascasarjana Universitas Udayana yang dijabat oleh Prof.Dr.dr.A.A.Raka
Sudewi,Sp.S(K) atas kesempatan yang diberikan kepada penulis untuk menjadi
mahasiswa Program Magister pada Program Pascasarjana Universitas Udayana.
Tidak lupa pula penulis ucapkan terima kasih kepada Prof.Ir. I.A.Dwi
Giriantari,M.EngSc.,PhD Ketua Program Studi Magister Teknik Elektro atas ijin
yang diberikan kepada penulis untuk mengikuti pendidikan Program Magister.
Ungkapan terima kasih penulis sampaikan pula kepada para penguji tesis, yaitu
Prof.Ir. Rukmi Sari Hartati,MT,.PhD , I Nyoman Satya Kumara,ST.,MSc.,PhD ,
vii

Ir. Linawati, MEngSC.,PhD yang telah memberikan masukan, saran, sanggahan, dan
koreksi sehingga tesis ini dapat terwujud seperti ini. Penulis juga mengucapkan
terima kasih sebesar-besarnya kepada PT. Tiara Cipta Nirwana yang telah
memberikan bantuan finansial kepada penulis dalam menyelesaikan studi ini.
Pada kesempatan ini penulis menyampaikan ucapan terima kasih yang tulus
disertai penghargaan kepada seluruh guru-guru yang telah membimbing penulis,
mulai dari sekolah dasar sampai perguruan tinggi. J uga penulis ucapkan terima kasih
kepada Ibu dan Ayah yang telah mengasuh dan membesarkan penulis, memberikan
dasar-dasar berpikir logik dan suasana demokratis sehingga tercipta lahan yang baik
untuk berkembangnya kreativitas. Akhirnya penulis sampaikan terima kasih kepada
isteri tercinta Ida Ayu Surya Agustini, serta anak-anak I.G.N.Agung Krisna Putra
Airsania dan I.G.A. Agung Karina Ersania tersayang, yang dengan penuh
pengorbanan telah memberikan kepada penulis kesempatan untuk lebih
berkonsentrasi menyelesaikan tesis ini.
Semoga Ida Sang Hyang Widhi Wasa/ Tuhan Yang Maha Esa selalu
melimpahkan rahmat-Nya kepada semua pihak yang telah membantu pelaksanaan
dan penyelesaian tesis ini, serta kepada penulis sekeluarga.







viii

ABSTRAK
MANAJEMEN PEMELIHARAAN TRANSFORMATOR TEGANGAN
MENENGAH BERBASIS ANALISIS KANDUNGAN GAS TERLARUT
(DGA)

Seiring dengan usia, minyak transformator akan mengalami penurunan
kualitas isolasi. Hal ini terjadi karena dua faktor, yaitu adanya pengaruh tegangan
(voltage stress) dan pemanasan (thermal stress). Akibatnya didalam minyak akan
terbentuk kontaminan yang dapat berupa partikel padat, gas ataupun cair.
Keberadaan kontaminan ini dapat menurunkan kualitas dielektrik minyak
transformator. Penurunan kualitas dielektrik minyak akan menyebabkan gangguan
internal transformator.
Untuk menghindari gangguan maka perlu dibuat suatu manajemen
pemeliharaan terhadap transformator-transformator tersebut. Pendekatan sederhana
untuk menentukan prioritas pemeliharaan transformator dibahas dalam tesis ini.
Pendekatan ini mengadopsi metode pembobotan dan skoring sederhana pada test
DGA dan tes tegangan tembus. Pembebanan transformator dan suhu operasi juga
dianggap sebagai parameter keputusan. Pendekatan ini diterapkan dalam manajemen
perawatan 29 trafo distribusi yang memasok sebuah bandara internasional.
Hasil penelitian menunjukkan dari 29 transformator yang di uji, satu
transformator berada pada prioritas 2 , dua transformator berada pada prioritas 3 ,
dan 26 transformator berada pada prioritas 4. Penanganan pekerjaan preventif
terhadap transformator yang masuk dalam kondisi kritis dengan melakukan treatment
/pemurnian kembali kondisi minyak transformator, dan membuat jadwal
pemeliharaan berkala terhadap transformator yang masih dalam katagori normal.
Pendekatan sederhana ini sangat berguna dalam membantu para engineer
dalam penentuan jadwal pemeliharaan transformator .Pendekatan yang dibahas di
sini dapat diperluas dengan menambahkan parameter lainnya untuk menunjang
pengambilan keputusan dalam manajemen aset.



Kata Kunci : Transformator, DGA, Jadwal Pemeliharaan.















ix

ABSTRACT

MAINTENANCE MANAGEMENT FOR MEDIUM VOLTAGE
TRANSFORMER BASED ON DISSOLVED GAS ANALYSIS (DGA)


The quality of transformers oil insulation is decreased due to its age. It
happens because of two factors: voltage stress and thermal stress. Contaminants such
as solid particles, gas and liquid will establish due to those factors. The occurrence of
those contaminants can decrease the quality of transformers oil insulation, that can
lead to the failure of transformer .
In order to prevent the transformer from failure, it needs a proper
maintenance management. A simple approach to determine the priority of
transformer maintenance is discussed in this thesis. This approach adopts a simple
method of weighting and scoring the test of DGA and breakdown voltage.
Transformer loading and operating temperature is also regarded as a decision
parameter. This approach is applied in care management 29 distribution transformers
supplying Ngurah Rai international airport.
The results of the 29 transformers in the test showed that one transformer is
categorised at priority 2, two transformers at priority 3, and 26 transformers at
priority 4. Preventive work scheduled to the transformer in critical condition by
performing treatment/oil purification. A periodic maintenance schedule is also
established for the transformer in normal category.
This simple approach is very useful in helping the engineers in the
determination of transformer maintenance schedule. Approach discussed here can be
extended by adding other parameters to support decision making in asset
management.


Keywords: transformers, DGA, Maintenance Schedule.


















x


DAFTAR ISI
Halaman
SAMPUL DALAMi
PRASYARAT GELAR ................................................................................................ ii
LEMBAR PERSETUJ UAN ....................................................................................... iii
PENETAPAN PANITIA PENGUJ I ...........................................................................iv
SURAT PERNYATAAN BEBAS PLAGIAT.v
UCAPAN TERIMA KASIH...vi
ABSTRAK.....viii
ABSTRACT.ix
DAFTAR ISI ................................................................................................................ x
DAFTAR TABEL ...................................................................................................... xii
DAFTAR GAMBAR ................................................................................................ xiii
DAFTAR SINGKATAN .......................................................................................... xiv

BAB I PENDAHULUAN
1.1 Latar Belakang ........................................................................................... 1
1.2 Rumusan Masalah ...................................................................................... 3
1.3 Tujuan ....................................................................................................... 3
1.4 Batasan Penelitian ...................................................................................... 3
1.5 Manfaat Penelitian ..................................................................................... 3

BAB II KAJIAN PUSTAKA
2.1 State of The Art Review .............................................................................. 4
2.2 Teori Dasar Transformator ......................................................................... 7
2.3 Kontruksi Transformator ............................................................................ 8
2.4 Gas Terlarut Pada Minyak Transforrmator .............................................. 10
2.5 Disolved Gas Analiser (DGA) ................................................................. 13
2.5.1 Metode Ekstraksi Gas14
2.5.2 Metode Interpretasi DGA......15
2.6 Klasifikasi Tingkat Prioritas Pemeliharaan..25
xi


BAB III METODE PENELITIAN
3.1 Rancangan Penelitian30
3.2 Lokasi dan Waktu Penelitian ................................................................... 31
3.3 Pengambilan Sampel Minyak Transformator .......................................... 32
3.4 Prosedur Pengambilan Sampel ................................................................. 34
3.5 Pengujian Tegangan Tembus ................................................................... 35
3.6 Disolved Gas Analiser (DGA) ................................................................ 36
3.7 Alur Proses Pengambilan Keputusan Manajemen
Perawatan Transformator ......................................................................... 41

BAB IV HASIL DAN PEMBAHASAN PENELITIAN
4.1 Hasil Tes Tegangan Tembus dan Tes DGA.....45
4.2 Hasil dan Pembahasan..55
4.2.1 Hasil Perhitungan Skor Total.55
4.2.2 Rentangan Skor..57
4.2.3 Hasil Klasifikasi.59
4.2.4 Interpretasi DGA...60

BAB V KESIMPULAN DAN SARAN-SARAN
5.1 Kesimpulan...67
5.2 Saran-saran68

DAFTAR PUSTAKA
LAMPIRAN







xii


DAFTAR TABEL

Halaman
2.1 Molekul Gas Hidrokarbon..............................................................................11
2.2 Batasan Konsentrasi Gas Terlarut...................................................................16
2.3 Periode pengambilan sample minyak dan prosedur operasi pada tiap
kondisi dan nilai TDCG. ..............................................................................18
2.4 Roger Ratio Code...22
2.5 Syarat Menggunakan Metode Segitiga Duval24
2.6 Tingkat akurasi berbagai metode interpretasi DGA... 27
2.7 Pemberian skor pada tes tegangan tembus minyak transformator..28
3.1 Data Sampel Uji..32
4.1 Hasil Tes Tegangan Tembus...45
4.2 Hasil Interpretasi Tes TDCG..46
4.3 Hasil Interpretasi Key Gas..47
4.4 Hasil Interpretasi Roger ratio.........48
4.5 Hasil Interpretasi Duval Triangel49
4.6 Hasil Pengukuran Beban.....50
4.7 Hasil Pengukuran Suhu...51
4.8 Pemberian Bobot dan Skor Individu..54
4.9 Hasil Perhitungan Total Skor Masing-masing Transformator56
4.10 Klasifikasi Prioritas.57
4.11 Klasifikasi Skor. 58
4.12 Skor Individu dari T10, T28 dan T7...59
4.13 Interpretasi DGA dari T10, T28 dan T7.61
4.14 J adwal Perawatan / Maintenance62






xiii


DAFTAR GAMBAR

Halaman
2.1 Kontruksi Transformator............................................................................... 8
2.2 Metode Exstrasi dengan Gas Cromatograpy................................................. 14
2.3 Metode Ekstraksi dengan Photoacoustic Spectroscopy.15
2.4 Grafik Prosentase Gas Kunci C2H4/Kriteria Thermal Oil.19
2.5 Grafik Prosentase Gas Kunci CO / Kriteria Thermal Celullose19
2.6 Grafik Prosentase Gas Kunci H2 / Kriteria Electrical Corona.20
2.7 Grafik Prosentase Gas Kunci C2H2 / Kriteria Arching in Oil..20
2.8 Koordinat Segitiga Duval...23
3.1 Alat Test Tegangan Tembus Minyak Transformator ....................................36
3.2 Syringe di sambungkan ke saluran penguras minyak trasformator................37
3.3 Minyak dialirkan ke syringe...........................................................................37
3.4 Memvacum syringe........................................................................................38
3.5 Cara pengambilan sampel yang benar dengan syringe...................................39
3.6 Sampel Minyak di Injeksikan ke Dalam Tabung Sampel...............................39
3.7 Kandungan Gas Yang Mudah Terbakar (TDCG)
Dalam Minyak Transformator........................................................................40
3.8 Alur Proses Pengambilan Keputusan Manajemen
Perawatan Transformator............................................................................... 42












xiv


DAFTAR SINGKATAN


AI : Aging Index
BDV : Breakdown Voltage
DGA : Dissolved Gas Analysis
GI : Gardu Induk
IEC : International Electrical Comision
KV : Kilo Volt
KVA : Kilo Volt Ampere
MPH : Main Power House
PPM : Part Per Milion
SS : Sub Stasion
TDCG : Total Dissolved Combustible Gas























xv

Anda mungkin juga menyukai