Anda di halaman 1dari 10

Laporan Praktikum Teknik Pesawat Radiologi

Tabung Sinar-X

Disusun oleh
Kelompok 3

Dosen: Andrey Nino, S.St, M.Eng

1. M.Yanuar Wicaksono (P1337430218055)


2. Ahmad Nurul Pratama (P1337430218010)
3. M. Rizal Ainun Ni’am (P1337430218000)
4. Zuhda Choirulrrizal (P1337430218000)
5. Arifina Nuridzati (P1337430218064)
6. Radistya Milenia Sari (P1337430218058)
7. Sylvia Ishlahul Ummah (P1337430218000)
8. Widya Septiani Lestari (P1337430218084)

PRODI D IV TEKNIK RADIOLOGI


POLITEKNIK KESEHATAN KEMENTRIAN KESEHATAN SEMARANG
2018
NO GAMBAR NAMA FUNGSI
FILAMENT MENURUNKAN TEGANGAN
RECTIFIER

KABEL PADA MENYAMBNGKAN HT DGN DIODE


HTT REFTIFIER

2
TABUNG X RAY TEMPAT TERJADINYA X RAY PADA
PADA SINGLE SINGLE TANK BERTIPE PELINDUNG
TANK MOBILE INHERN

SISI DINDING UNTUK MENCEGAH TERJADINYA


SINGLE TANK KEBOCORAN X RAY
YANG DILAPISI
TIMBAL

KABEL YANG MENGHUBUNGKAN HTT KE TABUNG


TERSAMBUNG DAN DIODE RECTIFIER
PADA HTT

5
2 KUMPARAN TEMPAT UNTUK MENAIKKAN
HTT TEGANGAN

TABUNG X RAY TEMPAT TERJADINYA X RAY PADA


PADA SINGLE PESAWAT SINGLE TANK MOBILE
TANK

7
SINGLE TANK PESAWAT SINAR X YANG DAPAT
MOBILE DIPINDAH PINDAH
TAMPAK
BAWAH

TEMPAT UNTUK MELINDUNGI


TABUNG X RAY DAN MELETAKKAN
TABUNG X RAY

TUBE HAUSING
9 TAMPAK
TERTUTUP

TUTUP SISI UNTUK MELINDUNGI S RAY DAN


TUBE HAUSING MECEGAH AGAR SERANGGA DAN
TIKUS MASUK K DALAM TUBE
HAUSING

10
11 SOKET KABEL TEMPAT MELEKATKAN KABEL KE
BAGIAN ANODA ANODA

12 TEMPAT KELUARNYA SINAR X DAN


TEMPAT MENEMPELNYA COLIMATOR

LUBANG
WINDOW
13 TEMPAT MEMASUKKAN KABEL UNTUK
BAGIAN ANODA

SOKET KABEL /
LUBANG KABEL
BAGIAN ANODA

14 KARET MENUTUPI BAGIAN KATODA


AGAR OLI TIDAK KELUAR

KARET SHILD
15 TEMPAT MELINDUNGI SEKALIGUS
TEMPAT BERSEMAYAMNYA TABUNG
SINAR X

TUBE HAUSING

16 TEMPAT TERJADINYA X RAY

INSERT TUBE

17 LUBANG TEMPAT KELUARNYA SINAR X


WINDOWS

18 KABEL YANG TERHUBUNG UNTUK


MENGHUBUNGKAN SISI KATODA KE 2
KABEL HTT DAN 1 BUAH KABEL FTT

3 BUAH KABEL
PADA SISI
ANODA
19 INSERT TUBE TERDAPAT 3 KABEL YANG
BAGIAN ANODA MENGHUBUNGKAN KE BAGIAN ROTOR

20 LUBANG TEMPAT KELUARNYA X RAY


WINDOWS

21 TUBE HAUSING TEMPAT MELINDUNGI DAN


TAMPAK DARI BERSEMAYAMNYA TABUNG X RAY
SISI LUBANG
WINDOWS
22 SINGLE TANK SEBUAH PESAWAT RADIOLOGI YANG
MOBILE DAPAT DI PINDAH PINDAHKAN
TAMPAK ATAS

23 INSERT TUBE TEMPAT REJADINYA X RAY


DENGAN
DOUBLE FOCUS
KASAR DAN
HALUS

24
25 SISI WINDOWS TEMPAT KELUARNYA X RAY

26 SISI ROTOR DENGAN KUMPARAN DENGAN KERJA


INDUKSI AGAR DAPAT MEMUTAR
ROTOR

Anda mungkin juga menyukai