Anda di halaman 1dari 4

LAPORAN SIMULASI MATCHING IMPEDANCE

ELEKTRONIKA TELEKOMUNIKASI + LAB

Biondi Andan Safarinda


05 / 1841160022
JTD 2C

JARINGAN TELEKOMUNIKASI DIGITAL


TEKNIK ELEKTRO
POLITEKNIK NEGERI MALANG
2019/2020
Rangkaian Matching Impedance
Model T

A. Tujuan
Mensimulasikan matching impedance model T

B. Gambar

C. Hasil
D. Pembahasan
1. 𝑄 = 10

𝑄
𝑄=√ −1
𝑅𝑇𝑒𝑟𝑘𝑒𝑐𝑖𝑙

𝑅𝑣
10 = √ − 1
50
𝑅𝑣
100 = −1
50
𝑅𝑣
101 =
50
𝑅𝑣 = 5050𝛺
2. Sebelah Kiri
𝑋𝑆1 = 𝑄 . 𝑅𝑆1
𝑅𝑃
𝑄 =√ −1
𝑅𝑆 𝑋𝑆1 = 10 . 50
𝑋𝑆1 = 500
5050
𝑄=√ −1 𝑅𝑃
50 𝑋𝑃1 =
𝑄
𝑄 = √100 5050
𝑋𝑃1 =
𝑄 = 10 10
𝑋𝑃1 = 505𝛺
3. Sebelah Kanan
𝑋𝑆2 = 𝑄. 𝑅𝑆2
𝑅𝑉
𝑄 =√ −1 𝑋𝑆2 = 2,01 . 1000
𝑅𝑃
𝑋𝑆2 = 2010
5050
𝑄=√ −1 𝑅𝑉
1000 𝑋𝑃2 =
𝑄
𝑄 = √4.05 5050
𝑋𝑃2 =
𝑄 = 2,01 2,01
𝑋𝑃2 = 2512,4𝛺
4. L&C
𝑋𝑆1 = 2𝜋𝑓𝐿1 𝑋𝑆2 = 2𝜋𝑓𝐿2
500 = 2𝜋106 𝐿1 2010 = 2𝜋106 𝐿2
𝐿1 = 7,95 . 10−5 𝐿1 = 3,199 . 10−4
𝐿1 = 79.5𝜇 𝐿1 = 0.319 𝑚𝐻

1 1
𝑋𝐶1 = 𝑋𝐶2 =
2𝜋𝑓𝐶1 2𝜋𝑓𝐶2
1 1
505 = 2512,4 =
2𝜋106 𝐶1 2𝜋106 𝐶2
𝐶1 = 3,15 . 10−10 𝐶2 = 6,33 . 10−10
𝐶1 = 0,315 𝑛𝐹 𝐶2 = 0,6 𝑛𝐹

E. Kesimpulan
Pada hasil grafik yang ditampilkan, titik tertinggi yang di tampilkan
menunjukkan titik 10MHz.