Anda di halaman 1dari 38

Dwi Joko Purnomo

(091321011)
teknik listrik 2A
Politeknik Negeri Bandung

150 KV

2572 MVA

Menghitung Impedansi
Impedansi sumber
Xs
=
8.748 ohm
Impedansi di sisi sekunder (sisi 20 KV)
Xs (sisi 20 KV)
=
0.156 ohm
=
0.15552099533437i

ohm

Menghitung Impedansi Penyulang


Z1 = Z2 (XLPE 150) =
0.381718+0.192712i
Z1 = Z2 (XLPE 240) =
0.22675+0.175958i

Z0 (XLPE 150)
Z0 (XLPE 240)
impedansi total
Z1 = Z2
=
Z0
=

=
=

0.659668+0.594813i
0.49885+0.052606i

0.608468+0.36867i
1.158518+0.647419i

ohm
ohm

lokasi
gangguan
(%panjang)
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100

Impedansi penyulang (Ohm)


urutan positif & negatif
(Z1&Z2)
0
0.0304234+0.0184335i
0.0608468+0.036867i
0.0912702+0.0553005i
0.1216936+0.073734i
0.152117+0.0921675i
0.1825404+0.110601i
0.2129638+0.1290345i
0.2433872+0.147468i
0.2738106+0.1659015i
0.304234+0.184335i
0.3346574+0.2027685i
0.3650808+0.221202i
0.3955042+0.2396355i
0.4259276+0.258069i
0.456351+0.2765025i
0.4867744+0.294936i
0.5171978+0.3133695i
0.5476212+0.331803i
0.5780446+0.3502365i
0.608468+0.36867i

Urutan Nol (Z0)


0
0.0579259+0.03237095i
0.1158518+0.0647419i
0.1737777+0.09711285i
0.2317036+0.1294838i
0.2896295+0.16185475i
0.3475554+0.1942257i
0.4054813+0.22659665i
0.4634072+0.2589676i
0.5213331+0.29133855i
0.579259+0.3237095i
0.6371849+0.35608045i
0.6951108+0.3884514i
0.7530367+0.42082235i
0.8109626+0.4531933i
0.8688885+0.48556425i
0.9268144+0.5179352i
0.9847403+0.55030615i
1.0426662+0.5826771i
1.1005921+0.61504805i
1.158518+0.647419i

Perhitungan Arus Ga
20 KV

TRAFO

60 MVA
XT =
RN =

3.667
11.89 %
12 ohm

Menghitung Reaktansi Trafo


Reaktansi trafo (Xt) pada 100%
Xt (pada 100%)=
6.667 ohm
Nilai reaktansi trafo tenaga
> Reaktansi urutan positif dan negatif
Xt (positif) = Xt (negatif) =

0.793
= 0.792666666666667i

ulang
Ohm
Ohm

Ohm
Ohm

> Reaktansi urutan 0


transformator daya dengan hubungan belitan Y
Xt0 =
0.793 ohm
= 0.792666666666667i
transformator daya dengan belitan Yyd
Xt0 =
2.378 ohm
= 2.378i
ohm
transformator daya dengan hubungan belitan YY
Xt0= 7.9266667 ohm
= 7.92666666666667i

Impedansi Jaringan (Ohm)


urutan positif & negatif
(Z1eq&Z2eq)
0.948187662001037i
0.0304234+0.966621162001037i
0.0608468+0.985054662001037i
0.0912702+1.00348816200104i
0.1216936+1.02192166200104i
0.152117+1.04035516200104i
0.1825404+1.05878866200104i
0.2129638+1.07722216200104i
0.2433872+1.09565566200104i
0.2738106+1.11408916200104i
0.304234+1.13252266200104i
0.3346574+1.15095616200104i
0.3650808+1.16938966200104i
0.3955042+1.18782316200104i
0.4259276+1.20625666200104i
0.456351+1.22469016200104i
0.4867744+1.24312366200104i
0.5171978+1.26155716200104i
0.5476212+1.27999066200104i
0.5780446+1.29842416200104i
0.608468+1.31685766200104i

Urutan Nol (Z0eq)


36+7.92666666666667i
36.0579259+7.95903761666667i
36.1158518+7.99140856666667i
36.1737777+8.02377951666667i
36.2317036+8.05615046666667i
36.2896295+8.08852141666667i
36.3475554+8.12089236666667i
36.4054813+8.15326331666667i
36.4634072+8.18563426666667i
36.5213331+8.21800521666667i
36.579259+8.25037616666667i
36.6371849+8.28274711666667i
36.6951108+8.31511806666667i
36.7530367+8.34748901666667i
36.8109626+8.37985996666667i
36.8688885+8.41223091666667i
36.9268144+8.44460186666667i
36.9847403+8.47697281666667i
37.0426662+8.50934376666667i
37.1005921+8.54171471666667i
37.158518+8.57408566666667i

Arus Gangguan (Ampere)


1 fasa ke
tanah

2 fasa

928.3126
925.01999
921.74984
918.50192
915.27601
912.07191
908.8894
905.72827
902.58831
899.46932
896.3711
893.29345
890.23617
887.19906
884.18195
881.18463
878.20692
875.24863
872.30958
869.38959
866.48848

10546.44
10340.19
10132.41
9924.275
9716.832
9510.971
9307.444
9106.875
8909.774
8716.548
8527.514
8342.911
8162.909
7987.619
7817.107
7651.393
7490.467
7334.288
7182.794
7035.904
6893.524

n Arus Gangguan Hubung Singkat


Data Trafo tenaga
Merk
= Hyundai
Tipe
= TL-369
Daya
=
60 MVA
Tegangan
=
150 / 20 KV
Impedansi ( Z %)
=
11.89 %
R ngr
=
20 ohm
Rasio CT
=
2000 / 5
Vektor Grup
= YNyn0 (dll)

Nama penyulang
Jenis penyulang
Panjang
Kabel yang digunakan

=
=
=
=

Data Penyulang
CLK
SKTM (Saluran Kabel Tegangan Menengah
3.667 Km
XLPE
150 mm 2 dan

ktansi Trafo

an negatif
ohm
0.792666666666667i

ohm

ubungan belitan Y

elitan Yyd

Kurva Arus Gangguan Hubung


14000

ubungan belitan YY
ohm

12000

rus Gangguan (Ampere)


3 fasa
12178
11939.828
11699.898
11459.566
11220.031
10982.323
10747.31
10515.713
10288.12
10065.002
9846.7252
9633.5638
9425.7149
9223.3084
9026.4175
8835.068
8649.2463
8468.9064
8293.9762
8124.3625
7959.9557

Arus Gangguan hubung singkat (A)

10000

8000

6000

4000

2000

10

15

20

25

30

35

40

45
Panjang Penyulang (%)

g Singkat
DATA TEKNIS
Data Teknis Kabel AL
XLPE
240 mm 2
Z1/Km
Z0/Km
XLPE
150 mm 2
Z1/Km
Z0/Km
Penyulang

M (Saluran Kabel Tegangan Menengah


XLPE

240 mm 2

va Arus Gangguan Hubung Singkat

Data per Km
R

jX
0.125
0.275
Data per Km

0.097
0.029
jX

0.206
0.356

0.104
0.321

3 fasa
2 fasa

1 fasa

45

50

55

Panjang Penyulang (%)

60

65

70

75

80

85

90

95

100

a Teknis Kabel AL
1.814 Km
R
0.227
0.499
1.853 Km
R
0.3817
0.6597

jX
0.176
0.053
jX
0.1927
0.5948

928.31
925.02
921.75
918.5
915.28
912.07
908.89
905.73
902.59
899.47
896.37
893.29
890.24
887.2
884.18
881.18
878.21
875.25
872.31
869.39
866.49

150 KV

2572 MVA

Menghitung Impedansi
Impedansi sumber
Xs
=
8.748 ohm
Impedansi di sisi sekunder (sisi 20 KV)
Xs (sisi 20 KV)
=
0.156 ohm
=
0.15552099533437i

ohm

Menghitung Impedansi Penyulang


Z1 = Z2 (XLPE 150) =
0.381718+0.192712i
Z1 = Z2 (XLPE 240) =
0.22675+0.175958i
Z0 (XLPE 150)
Z0 (XLPE 240)
impedansi total
Z1 = Z2
=

=
=

0.659668+0.594813i
0.49885+0.052606i

0.608468+0.36867i

ohm

Z0

lokasi
gangguan
(%panjang)
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100

1.158518+0.647419i

ohm

Impedansi penyulang (Ohm)


urutan positif & negatif
(Z1&Z2)
0
0.0304234+0.0184335i
0.0608468+0.036867i
0.0912702+0.0553005i
0.1216936+0.073734i
0.152117+0.0921675i
0.1825404+0.110601i
0.2129638+0.1290345i
0.2433872+0.147468i
0.2738106+0.1659015i
0.304234+0.184335i
0.3346574+0.2027685i
0.3650808+0.221202i
0.3955042+0.2396355i
0.4259276+0.258069i
0.456351+0.2765025i
0.4867744+0.294936i
0.5171978+0.3133695i
0.5476212+0.331803i
0.5780446+0.3502365i
0.608468+0.36867i

Urutan Nol (Z0)


0
0.0579259+0.03237095i
0.1158518+0.0647419i
0.1737777+0.09711285i
0.2317036+0.1294838i
0.2896295+0.16185475i
0.3475554+0.1942257i
0.4054813+0.22659665i
0.4634072+0.2589676i
0.5213331+0.29133855i
0.579259+0.3237095i
0.6371849+0.35608045i
0.6951108+0.3884514i
0.7530367+0.42082235i
0.8109626+0.4531933i
0.8688885+0.48556425i
0.9268144+0.5179352i
0.9847403+0.55030615i
1.0426662+0.5826771i
1.1005921+0.61504805i
1.158518+0.647419i

Perhitungan Arus Ga
20 KV

TRAFO

60 MVA
XT =
RN =

3.667
11.89 %
12 ohm

Menghitung Reaktansi Trafo


Reaktansi trafo (Xt) pada 100%
Xt (pada 100%)=
6.667 ohm

Ohm
Ohm
Ohm
Ohm

Nilai reaktansi trafo tenaga


> Reaktansi urutan positif dan negatif
Xt (positif) = Xt (negatif) =
0.793
= 0.792666666666667i
> Reaktansi urutan 0
transformator daya dengan hubungan belitan Y
Xt0 =
0.793 ohm
= 0.792666666666667i
transformator daya dengan belitan Yyd
Xt0 =
2.378 ohm
= 2.378i
ohm
transformator daya dengan hubungan belitan YY

Xt0= 7.92667 ohm


= 7.92666666666667i

Impedansi Jaringan (Ohm)


urutan positif & negatif
(Z1eq&Z2eq)
0.948187662001037i
0.0304234+0.966621162001037i
0.0608468+0.985054662001037i
0.0912702+1.00348816200104i
0.1216936+1.02192166200104i
0.152117+1.04035516200104i
0.1825404+1.05878866200104i
0.2129638+1.07722216200104i
0.2433872+1.09565566200104i
0.2738106+1.11408916200104i
0.304234+1.13252266200104i
0.3346574+1.15095616200104i
0.3650808+1.16938966200104i
0.3955042+1.18782316200104i
0.4259276+1.20625666200104i
0.456351+1.22469016200104i
0.4867744+1.24312366200104i
0.5171978+1.26155716200104i
0.5476212+1.27999066200104i
0.5780446+1.29842416200104i
0.608468+1.31685766200104i

Urutan Nol (Z0eq)


36+2.378i
36.0579259+2.41037095i
36.1158518+2.4427419i
36.1737777+2.47511285i
36.2317036+2.5074838i
36.2896295+2.53985475i
36.3475554+2.5722257i
36.4054813+2.60459665i
36.4634072+2.6369676i
36.5213331+2.66933855i
36.579259+2.7017095i
36.6371849+2.73408045i
36.6951108+2.7664514i
36.7530367+2.79882235i
36.8109626+2.8311933i
36.8688885+2.86356425i
36.9268144+2.8959352i
36.9847403+2.92830615i
37.0426662+2.9606771i
37.1005921+2.99304805i
37.158518+3.025419i

Arus Gangguan (Ampere)


1 fasa
ke
2 fasa
tanah
955.539
952.225
948.933
945.66
942.409
939.177
935.966
932.775
929.603
926.451
923.319
920.206
917.111
914.036
910.98
907.942
904.923
901.922
898.94
895.975
893.029

10546.4
10340.2
10132.4
9924.28
9716.83
9510.97
9307.44
9106.87
8909.77
8716.55
8527.51
8342.91
8162.91
7987.62
7817.11
7651.39
7490.47
7334.29
7182.79
7035.9
6893.52

Arus Gangguan Hubung Singka


Data Trafo tenaga
Merk
= Hyundai
Tipe
= TL-369
Daya
=
60 MVA
Tegangan
=
150 / 20 KV
Impedansi ( Z %)
=
11.89 %
R ngr
=
20 ohm
Rasio CT
=
2000 / 5
Vektor Grup
= YNyn0 (dll)

Nama penyulang
Jenis penyulang
Panjang
Kabel yang digunakan

nsi Trafo

negatif
ohm
0.792666666666667i ohm

bungan belitan Y

666666667i
itan Yyd

bungan belitan YY

=
=
=
=

Data Penyulang
CLK
SKTM (Saluran Kabel Tegangan Meneng
3.667 Km
XLPE
150 mm 2 dan

ohm

Kurva Arus Gangguan Hubung

angguan (Ampere)

14000

3 fasa
12000

10000

Arus Gangguan hubung singkat (A)

12177.975
11939.828
11699.898
11459.566
11220.031
10982.323
10747.31
10515.713
10288.12
10065.002
9846.7252
9633.5638
9425.7149
9223.3084
9026.4175
8835.068
8649.2463
8468.9064
8293.9762
8124.3625
7959.9557

8000

6000

4000

2000

0
0

10

15

20

25

30

35

40

45

50

Panjang Penyulang (%)

Singkat
DATA TEKNIS
Data Teknis Kabel AL
XLPE
240 mm 2
Z1/Km
Z0/Km
XLPE
150 mm 2
Z1/Km
Z0/Km

lang

ran Kabel Tegangan Menengah


XLPE

240 mm 2

Data per Km
R

jX
0.125
0.275
Data per Km

0.097
0.029
jX

0.206
0.356

0.104
0.321

Gangguan Hubung Singkat

3 fasa
2 fasa
1 fasa

50

55

60

Panjang Penyulang (%)

65

70

75

80

85

90

95

100

is Kabel AL
1.814 Km
R
0.227
0.499
1.853 Km
R
0.3817
0.6597

jX
0.176
0.053
jX
0.1927
0.5948

150 KV

2572 MVA

Menghitung Impedansi
Impedansi sumber
Xs
=
8.748 ohm
Impedansi di sisi sekunder (sisi 20 KV)
Xs (sisi 20 KV)
=
0.156 ohm
=
0.15552099533437i

ohm

Menghitung Impedansi Penyulang


Z1 = Z2 (XLPE 150) =
0.381718+0.192712i
Z1 = Z2 (XLPE 240) =
0.22675+0.175958i
Z0 (XLPE 150)
Z0 (XLPE 240)
impedansi total
Z1 = Z2
=

=
=

0.659668+0.594813i
0.49885+0.052606i

0.608468+0.36867i

ohm

Z0

lokasi
gangguan
(%panjang)
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100

1.158518+0.647419i

ohm

Impedansi penyulang (Ohm)


urutan positif & negatif
(Z1&Z2)
0
0.0304234+0.0184335i
0.0608468+0.036867i
0.0912702+0.0553005i
0.1216936+0.073734i
0.152117+0.0921675i
0.1825404+0.110601i
0.2129638+0.1290345i
0.2433872+0.147468i
0.2738106+0.1659015i
0.304234+0.184335i
0.3346574+0.2027685i
0.3650808+0.221202i
0.3955042+0.2396355i
0.4259276+0.258069i
0.456351+0.2765025i
0.4867744+0.294936i
0.5171978+0.3133695i
0.5476212+0.331803i
0.5780446+0.3502365i
0.608468+0.36867i

Urutan Nol (Z0)


0
0.0579259+0.03237095i
0.1158518+0.0647419i
0.1737777+0.09711285i
0.2317036+0.1294838i
0.2896295+0.16185475i
0.3475554+0.1942257i
0.4054813+0.22659665i
0.4634072+0.2589676i
0.5213331+0.29133855i
0.579259+0.3237095i
0.6371849+0.35608045i
0.6951108+0.3884514i
0.7530367+0.42082235i
0.8109626+0.4531933i
0.8688885+0.48556425i
0.9268144+0.5179352i
0.9847403+0.55030615i
1.0426662+0.5826771i
1.1005921+0.61504805i
1.158518+0.647419i

Perhitungan Arus G
20 KV

TRAFO

60 MVA
XT =
RN =

3.667
11.89 %
12 ohm

Menghitung Reaktansi Trafo


Reaktansi trafo (Xt) pada 100%
Xt (pada 100%)=
6.667 ohm

Ohm
Ohm
Ohm
Ohm

Nilai reaktansi trafo tenaga


> Reaktansi urutan positif dan negatif
Xt (positif) = Xt (negatif) =
0.793
= 0.792666666666667i
> Reaktansi urutan 0
transformator daya dengan hubungan belitan Y
Xt0 =
0.793 ohm
= 0.792666666666667i
transformator daya dengan belitan Yyd
Xt0 =
2.378 ohm
= 2.378i
ohm
transformator daya dengan hubungan belitan YY

Xt0= 7.92667 ohm


= 7.92666666666667i

Impedansi Jaringan (Ohm)


urutan positif & negatif
(Z1eq&Z2eq)
0.948187662001037i
0.0304234+0.966621162001037i
0.0608468+0.985054662001037i
0.0912702+1.00348816200104i
0.1216936+1.02192166200104i
0.152117+1.04035516200104i
0.1825404+1.05878866200104i
0.2129638+1.07722216200104i
0.2433872+1.09565566200104i
0.2738106+1.11408916200104i
0.304234+1.13252266200104i
0.3346574+1.15095616200104i
0.3650808+1.16938966200104i
0.3955042+1.18782316200104i
0.4259276+1.20625666200104i
0.456351+1.22469016200104i
0.4867744+1.24312366200104i
0.5171978+1.26155716200104i
0.5476212+1.27999066200104i
0.5780446+1.29842416200104i
0.608468+1.31685766200104i

Urutan Nol (Z0eq)


36+0.792666666666667i
36.0579259+0.825037616666667i
36.1158518+0.857408566666667i
36.1737777+0.889779516666667i
36.2317036+0.922150466666667i
36.2896295+8.08852141666667i
36.3475554+0.986892366666667i
36.4054813+8.15326331666667i
36.4634072+1.05163426666667i
36.5213331+1.08400521666667i
36.579259+1.11637616666667i
36.6371849+1.14874711666667i
36.6951108+1.18111806666667i
36.7530367+1.21348901666667i
36.8109626+1.24585996666667i
36.8688885+1.27823091666667i
36.9268144+1.31060186666667i
36.9847403+1.34297281666667i
37.0426662+1.37534376666667i
37.1005921+1.40771471666667i
37.158518+1.44008566666667i

Arus Gangguan (Ampere)


1 fasa
ke
2 fasa
tanah
959.577
956.302
953.046
949.81
946.593
912.072
940.216
905.728
933.916
930.794
927.69
924.605
921.538
918.489
915.458
912.445
909.45
906.472
903.512
900.569
897.643

10546.4
10340.2
10132.4
9924.28
9716.83
9510.97
9307.44
9106.87
8909.77
8716.55
8527.51
8342.91
8162.91
7987.62
7817.11
7651.39
7490.47
7334.29
7182.79
7035.9
6893.52

Arus Gangguan Hubung Singkat


Data Trafo tenaga
Merk
= Hyundai
Tipe
= TL-369
Daya
=
60 MVA
Tegangan
=
150 / 20 KV
Impedansi ( Z %)
=
11.89 %
R ngr
=
20 ohm
Rasio CT
=
2000 / 5
Vektor Grup
= YNyn0 (dll)

Nama penyulang
Jenis penyulang
Panjang
Kabel yang digunakan

i Trafo

gatif
ohm
0.792666666666667i ohm

gan belitan Y

666666667i
Yyd

gan belitan YY

=
=
=
=

Data Penyulang
CLK
SKTM (Saluran Kabel Tegangan Meneng
3.667 Km
XLPE
150 mm 2 dan

ohm

Kurva Arus Gangguan Hubung

angguan (Ampere)
14000

3 fasa
12000

10000

Arus Gangguan hubung singkat (A)

12177.975
11939.828
11699.898
11459.566
11220.031
10982.323
10747.31
10515.713
10288.12
10065.002
9846.7252
9633.5638
9425.7149
9223.3084
9026.4175
8835.068
8649.2463
8468.9064
8293.9762
8124.3625
7959.9557

8000

6000

4000

2000

0
0

10

15

20

25

30

35

40

45

50

Panjang Penyulang (%)

Singkat
DATA TEKNIS
Data Teknis Kabel AL
XLPE
240 mm 2
Z1/Km
Z0/Km
XLPE
150 mm 2
Z1/Km
Z0/Km

lang

ran Kabel Tegangan Menengah


XLPE

240 mm 2

Data per Km
R

jX
0.125
0.275
Data per Km

0.097
0.029
jX

0.206
0.356

0.104
0.321

Gangguan Hubung Singkat

3 fasa
2 fasa
1 fasa

50

55

anjang Penyulang (%)

60

65

70

75

80

85

90

95

100

is Kabel AL
1.814 Km
R
0.227
0.499
1.853 Km
R
0.3817
0.6597

jX
0.176
0.053
jX
0.1927
0.5948

trafo hubungan YY

rectangular(Z1 Eq) rectangular (Z0 eq)


0.948
36.86233911
0.967
36.92587575
0.987
36.9894223
1.008
37.0529787
1.029
37.11654491
1.051
37.18012087
1.074
37.24370653
1.098
37.30730185
1.122
37.37090677
1.147
37.43452125
1.173
37.49814523
1.199
37.56177867
1.225
37.62542153
1.252
37.68907374
1.279
37.75273527
1.307
37.81640607
1.335
37.88008609
1.363
37.94377529
1.392
38.00747361
1.421
38.07118102
1.451
38.13489747

2 x Z1eq

1.89637532400207i
0.0608468+1.93324232400207i
0.1216936+1.97010932400207i
0.1825404+2.00697632400208i
0.2433872+2.04384332400208i
0.304234+2.08071032400208i
0.3650808+2.11757732400208i
0.4259276+2.15444432400208i
0.4867744+2.19131132400208i
0.5476212+2.22817832400208i
0.608468+2.26504532400208i
0.6693148+2.30191232400208i
0.7301616+2.33877932400208i
0.7910084+2.37564632400208i
0.8518552+2.41251332400208i
0.912702+2.44938032400208i
0.9735488+2.48624732400208i
1.0343956+2.52311432400208i
1.0952424+2.55998132400208i
1.1560892+2.59684832400208i
1.216936+2.63371532400208i

trafo hubungan YyD

rectangular(Z1 Eq) rectangular (Z0 eq)


0.948
36.07845457
0.967
36.13839936
0.987
36.19836653
1.008
36.25835596
1.029
36.31836754
1.051
36.37840117
1.074
36.43845673
1.098
36.49853411
1.122
36.55863322
1.147
36.61875393
1.173
36.67889616
1.199
36.73905978
1.225
36.79924469
1.252
36.8594508
1.279
36.91967799
1.307
36.97992617
1.335
37.04019523
1.363
37.10048506

2 x Z1eq

1.89637532400207i
0.0608468+1.93324232400207i
0.1216936+1.97010932400207i
0.1825404+2.00697632400208i
0.2433872+2.04384332400208i
0.304234+2.08071032400208i
0.3650808+2.11757732400208i
0.4259276+2.15444432400208i
0.4867744+2.19131132400208i
0.5476212+2.22817832400208i
0.608468+2.26504532400208i
0.6693148+2.30191232400208i
0.7301616+2.33877932400208i
0.7910084+2.37564632400208i
0.8518552+2.41251332400208i
0.912702+2.44938032400208i
0.9735488+2.48624732400208i
1.0343956+2.52311432400208i

1.392
1.421
1.451

37.16079558
37.22112667
37.28147824

1.0952424+2.55998132400208i
1.1560892+2.59684832400208i
1.216936+2.63371532400208i

trafo hubungan DY

rectangular(Z1 Eq) rectangular (Z0 eq)


0.948
36.00872562
0.967
36.06736346
0.987
36.12602802
1.008
36.18471916
1.029
36.24343675
1.051
37.18012087
1.074
36.36095076
1.098
37.30730185
1.122
36.47856904
1.147
36.53741697
1.173
36.59629059
1.199
36.65518977
1.225
36.7141144
1.252
36.77306436
1.279
36.83203951
1.307
36.89103975
1.335
36.95006494
1.363
37.00911497
1.392
37.06818973
1.421
37.12728909
1.451
37.18641293

2 x Z1eq

1.89637532400207i
0.0608468+1.93324232400207i
0.1216936+1.97010932400207i
0.1825404+2.00697632400208i
0.2433872+2.04384332400208i
0.304234+2.08071032400208i
0.3650808+2.11757732400208i
0.4259276+2.15444432400208i
0.4867744+2.19131132400208i
0.5476212+2.22817832400208i
0.608468+2.26504532400208i
0.6693148+2.30191232400208i
0.7301616+2.33877932400208i
0.7910084+2.37564632400208i
0.8518552+2.41251332400208i
0.912702+2.44938032400208i
0.9735488+2.48624732400208i
1.0343956+2.52311432400208i
1.0952424+2.55998132400208i
1.1560892+2.59684832400208i
1.216936+2.63371532400208i

2*Z1eq + Z0eq

36+9.82304199066874i
36.1187727+9.89227994066874i
36.2375454+9.96151789066874i
36.3563181+10.0307558406687i
36.4750908+10.0999937906688i
36.5938635+10.1692317406687i
36.7126362+10.2384696906688i
36.8314089+10.3077076406688i
36.9501816+10.3769455906688i
37.0689543+10.4461835406688i
37.187727+10.5154214906687i
37.3064997+10.5846594406687i
37.4252724+10.6538973906687i
37.5440451+10.7231353406687i
37.6628178+10.7923732906687i
37.7815905+10.8616112406688i
37.9003632+10.9308491906687i
38.0191359+11.0000871406688i
38.1379086+11.0693250906687i
38.2566813+11.1385630406687i
38.375454+11.2078009906688i

2*Z1eq + Z0eq

36+4.27437532400207i
36.1187727+4.34361327400207i
36.2375454+4.41285122400207i
36.3563181+4.48208917400208i
36.4750908+4.55132712400208i
36.5938635+4.62056507400208i
36.7126362+4.68980302400208i
36.8314089+4.75904097400208i
36.9501816+4.82827892400208i
37.0689543+4.89751687400208i
37.187727+4.96675482400208i
37.3064997+5.03599277400208i
37.4252724+5.10523072400208i
37.5440451+5.17446867400208i
37.6628178+5.24370662400208i
37.7815905+5.31294457400208i
37.9003632+5.38218252400208i
38.0191359+5.45142047400208i

rectangular (2*Z1eq + Z0eq)

37.316
37.449
37.582
37.715
37.848
37.981
38.114
38.247
38.380
38.513
38.646
38.779
38.912
39.045
39.179
39.312
39.445
39.578
39.712
39.845
39.979

rectangular (2*Z1eq + Z0eq)

36.253
36.379
36.505
36.632
36.758
36.884
37.011
37.138
37.264
37.391
37.518
37.645
37.772
37.899
38.026
38.153
38.281
38.408

3 x Vph

34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016

3 x Vph

34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016

38.1379086+5.52065842400208i
38.2566813+5.58989637400208i
38.375454+5.65913432400208i

2*Z1eq + Z0eq

36+2.68904199066874i
36.1187727+2.75827994066874i
36.2375454+2.82751789066874i
36.3563181+2.89675584066875i
36.4750908+2.96599379066875i
36.5938635+10.1692317406687i
36.7126362+3.10446969066875i
36.8314089+10.3077076406688i
36.9501816+3.24294559066875i
37.0689543+3.31218354066875i
37.187727+3.38142149066875i
37.3064997+3.45065944066875i
37.4252724+3.51989739066875i
37.5440451+3.58913534066875i
37.6628178+3.65837329066875i
37.7815905+3.72761124066875i
37.9003632+3.79684919066875i
38.0191359+3.86608714066875i
38.1379086+3.93532509066875i
38.2566813+4.00456304066875i
38.375454+4.07380099066875i

38.535
38.663
38.790

rectangular (2*Z1eq + Z0eq)

36.100
36.224
36.348
36.472
36.595
37.981
36.844
38.247
37.092
37.217
37.341
37.466
37.590
37.715
37.840
37.965
38.090
38.215
38.340
38.466
38.591

34641.016
34641.016
34641.016

3 x Vph

34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016
34641.016

rectangular (2 x Z1eq)
1.896
1.934
1.974
2.015
2.058
2.103
2.149
2.196
2.245
2.294
2.345
2.397
2.450
2.504
2.558
2.614
2.670
2.727
2.784
2.843
2.901

Vph
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547

rectangular (2 x Z1eq)
1.896
1.934
1.974
2.015
2.058
2.103
2.149
2.196
2.245
2.294
2.345
2.397
2.450
2.504
2.558
2.614
2.670
2.727

Vph
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547

2.784 11547
2.843 11547
2.901 11547

rectangular (2 x Z1eq)
1.896
1.934
1.974
2.015
2.058
2.103
2.149
2.196
2.245
2.294
2.345
2.397
2.450
2.504
2.558
2.614
2.670
2.727
2.784
2.843
2.901

Vph
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547
11547

Anda mungkin juga menyukai