Anda di halaman 1dari 14

BLEED STEAM DRAIN

DCA TTD
m1 h1 m2 h2 m3 h3 m dot drain
C C kg/s kJ/kg kg/s kJ/kg kg/s kJ/kg kg/s
5 5 40.366 3156.2 47.732 3052.71 25.228 3358.88 113.327
5 0 41.65 3156.2 48.884 3052.71 29.879 3358.88 120.412
5 -2 42.192 3156.2 49.362 3052.71 31.756 3358.88 123.31
127403.1692 145711.95372 84737.82464 89675.6551
131455.73 149228.67564 100359.97552 95282.0156
133166.3904 150687.87102 106664.59328 97575.203
TTD (C) q all HPH (kW)
5 268177.29 292943.652
0 285762.37 292941.929
-2 292943.65
BLEED STEAM DRAIN
DCA TTD
m1 h1 m2 h2 m3 h3 m dot drain
C C kg/s kJ/kg kg/s kJ/kg kg/s kJ/kg kg/s
5 0 41.65 3156.2 48.884 3052.71 29.879 3358.88 120.412
10 0 42.193 3156.2 49.372 3052.71 30.069 3358.88 121
15 0 42.759 3156.2 49.871 3052.71 30.26 3358.88 122.89
20 0 43.35 3156.2 50.38 3052.71 30.45 3358.88 124.18
TTD
0 DCA m drainT in boiler Ef m dot fwq heat transfer
0 5 120.41 281.88 44.717 614.672 285759 295000
0 10 121 281.88 44.699 615.063 285895.9
290000
0 15 122.89 281.88 44.685 615.466 286128.1
285000
20 124.18 281.88 44.668 615.882 286321.3
280000

q (kW)
275000
270000
265000

TTD vs m dot feedwater 260000


255000
618 -3 -2

616
m dot feedwater (kg/s)

614

612 TT
44.800%
610
44.750%
608
Effisiensi thermal

44.700%
606
-3 -2 -1 0 1 2 3 4 5 6
44.650%
TTD
44.600%

44.550%

44.500%
-3 -2
Effisiensi ther
44.650%

44.600%

44.550%

44.500%
TTD vs m dot bleed steam -3 -2

60

50

m dot bleed steam (kg/s)


40
m1
30 m2 44.73
m3 44.72
20
44.71
10

Effisiensi thermal
44.7
44.69
0
-3 -2 -1 0 1 2 3 4 5 6 44.68
TTD 44.67
44.66
44.65
44.64
4

DCA vs m dot feedwater DCA


616
286400
615.8
286300
615.6
286200
m dot feedwater (kg/s)

615.4
286100

q all HPH (kg/s)


615.2
286000
615
285900
614.8
285800
614.6
285700
614.4
285600
614.2
285500
614
285400
4 6 8 10 12 14 16 18 20 22
4 6 8
DCA

DCA vs m dot b
55

50
m dot bleed steam (kg/s)

45

40

35

30

25

20
4 6 8 10 12 14
DCA
m dot bleed st
35

30

25

20
4 6 8 10 12 14
DCA
DRAIN FEEDWATER
h drain mfw h fw out h fw in Ef
kJ/kg kg/s kJ/kg kJ/kg
791.3 609.93 1216.52 776.83 44.607%
791.3 614.67 1241.72 776.83 44.717%
791.3 616.62 1251.91 776.83 44.762%
89675.6551
95282.0156
97575.203

609.93 439.69
614.67 464.89
616.62 475.08
DRAIN FEEDWATER
h drain mfw h fw out h fw in Ef
kJ/kg kg/s kJ/kg kJ/kg
759.2 614.67 1241.72 776.83 44.717%
759.2 615.06 1241.72 776.83 44.699%
759.2 615.47 1241.72 776.83 44.685%
759.2 615.88 1241.72 776.83 44.668%

TTD vs q all HPH


295000
290000
285000
280000
q (kW)

275000
270000
265000
260000
255000
-3 -2 -1 0 1 2 3 4 5 6
TTD (C)

TTD vs Effisiensi Thermal


44.800%

44.750%
Effisiensi thermal

44.700%

44.650%

44.600%

44.550%

44.500%
-3 -2 -1 0 1 2 3 4 5 6
TTD
Effisiensi ther
44.650%

44.600%

44.550%

44.500%
-3 -2 -1 0 1 2 3 4 5 6
TTD

DCA vs Effisiensi Thermal


44.73
44.72
44.71
Effisiensi thermal

44.7
44.69
44.68
44.67
44.66
44.65
44.64
4 6 8 10 12 14 16 18 20 22
DCA

DCA vs q all HPH


286400
286300
286200
286100
286000
285900
285800
285700
285600
285500
285400
4 6 8 10 12 14 16 18 20 22
DCA

DCA vs m dot bleed steam

kg/s
kg/s
kg/s

4 6 8 10 12 14 16 18 20 22
DCA
kg/s
kg/s

4 6 8 10 12 14 16 18 20 22
DCA
BLEED STEAM DRAIN
DCA TTD
m1 h1 m2 h2 m3 h3 m dot drain
C C kg/s kJ/kg kg/s kJ/kg kg/s kJ/kg kg/s
5 5 40.366 3156.2 47.732 3052.71 25.228 3358.88 113.327
5 0 41.65 3156.2 48.884 3052.71 29.879 3358.88 120.412
5 -2 42.192 3156.2 49.362 3052.71 31.756 3358.88 123.31
127403.1692 145711.95372 84737.82464 89675.6551
131455.73 149228.67564 100359.97552 95282.0156
133166.3904 150687.87102 106664.59328 97575.203
TTD (C) q all HPH (kW)
5 268177.29 292943.652
0 285762.37 292941.929
-2 292943.65
BLEED STEAM DRAIN
DCA TTD
m1 h1 m2 h2 m3 h3 m dot drain
C C kg/s kJ/kg kg/s kJ/kg kg/s kJ/kg kg/s
5 0 41.65 3156.2 48.884 3052.71 29.879 3358.88 120.412
10 0 42.193 3156.2 49.372 3052.71 30.069 3358.88 121.635
15 0 42.759 3156.2 49.871 3052.71 30.26 3358.88 122.89
20 0 43.35 3156.2 50.38 3052.71 30.45 3358.88 124.18
TTD
0 DCA m drainT in boiler Ef m dot fwq heat transfer
0 5 120.41 281.88 44.717 614.672 285759 295000
0 10 121 281.88 44.699 615.063 285895.9
290000
0 15 122.89 281.88 44.685 615.466 286128.1
285000
20 124.18 281.88 44.668 615.882 286321.3
280000

q (kW)
275000
270000
265000

TTD vs m dot feedwater 260000


255000
618 -3

616
m dot feedwater (kg/s)

614

612 T
46.000%
610

608 45.500%
Effisiensi thermal

606 45.000%
-3 -2 -1 0 1 2 3 4 5 6
TTD 44.500%

44.000%

43.500%
-3 -2
45.000%

Effisiensi ther
44.500%

44.000%

43.500%
TTD vs m dot bleed steam -3 -2

60

50

m dot bleed steam (kg/s)


40
m1
30 m2 44.73
m3 44.72
20
44.71
10

Effisiensi thermal
44.7
44.69
0
-3 -2 -1 0 1 2 3 4 5 6 44.68
TTD 44.67
44.66
44.65
44.64
4

DCA vs m dot feedwater DCA


616
286400
615.8
286300
615.6
286200
m dot feedwater (kg/s)

615.4
286100

q all HPH (kg/s)


615.2
286000
615
285900
614.8
285800
614.6
285700
614.4
285600
614.2
285500
614
285400
4 6 8 10 12 14 16 18 20 22
4 6 8
DCA

DCA vs m dot
55

50
m dot bleed steam (kg/s)

45

40

35

30

25

20
4 6 8 10 12 1
DCA
m dot bleed st
35

30

25

20
4 6 8 10 12 1
DCA
DRAIN FEEDWATER
Q boiler Mass flow
h drain mfw h fw out h fw in Ef coal NPHR
kJ/kg kg/s kJ/kg kJ/kg MW kg/s
791.3 609.932 1216.52 776.83 44.314% 1312.571 53.335 594678.81 1897.849 708662.6
791.3 614.672 1241.72 776.83 45.671% 1302.145 52.911 594707.69 1882.671 708696.9
791.3 616.616 1251.91 776.83 45.819% 1297.898 52.739 594778 1876.329 708780.4
89675.6551
95282.0156
97575.203

609.932 439.69
614.672 464.89
616.616 475.08
DRAIN FEEDWATER
Q boiler Mass flow
h drain mfw h fw out h fw in Ef coal NPHR
kJ/kg kg/s kJ/kg kJ/kg MW kg/s
759.2 614.672 1241.72 776.83 45.671% 1302145 52.911 594707.69 1882.671 708696.9
759.2 615.063 1241.72 776.83 44.650% 1302732 52.935 594699 1883.552 708690
759.2 615.466 1241.72 776.83 45.628% 1303337 52.960 594690 1884.47 708780.4
759.2 615.882 1241.72 776.83 44.606% 1303961 52.985

TTD vs q all HPH


295000
290000
285000
280000
q (kW)

275000
270000
265000
260000
255000
-3 -2 -1 0 1 2 3 4 5 6
TTD (C)

TTD vs Effisiensi Thermal


46.000%

45.500%
Effisiensi thermal

45.000%

44.500%

44.000%

43.500%
-3 -2 -1 0 1 2 3 4 5 6
TTD
45.000%

Effisiensi ther 44.500%

44.000%

43.500%
-3 -2 -1 0 1 2 3 4 5 6
TTD

DCA vs Effisiensi Thermal


44.73
44.72
44.71
Effisiensi thermal

44.7
44.69
44.68
44.67
44.66
44.65
44.64
4 6 8 10 12 14 16 18 20 22
DCA

DCA vs q all HPH


286400
286300
286200
286100
286000
285900
285800
285700
285600
285500
285400
4 6 8 10 12 14 16 18 20 22
DCA

DCA vs m dot bleed steam

kg/s
kg/s
kg/s

4 6 8 10 12 14 16 18 20 22
DCA
kg/s
kg/s

4 6 8 10 12 14 16 18 20 22
DCA
tphr m1 h1 m2 h2 m3 h3 m out h out
124.180 858.21 26.924 3161.16 464.778 593.61 615.882 759.2 20
1592.593 122.890 835.79 28.104 3161.16 464.472 593.61 615.446 759.2 15
1579.855 121.635 813.48 29.253 3161.16 464.176 593.61 615.063 759.2 10
1574.534 120.412 791.30 30.373 3161.16 463.888 593.61 614.672 759.2 5
467580.45822 467577.6144
467266.69766 467246.6032
466960.56864 466955.8296
466664.48396 466658.9824

tphr

1579.855
1580.587
1581.132
q DA
467577.61
467246.60
466955.83
466658.98

1
3 out

Anda mungkin juga menyukai