SAMAKAN TERLEBIH DAHULU PROTOCOL DI SOFTWARE DIALOG 600 DENGAN HARD WARE EC600 DAN KLIK
TANDA CENTANG PADA BAGIAN KANAN ATAS .
COMUNICATION DIGUNAKAN UNTUK MENSETING PRTOTOKOL DAN SPEED UNTUK KOMUNIKASI RS 232
DAN RS 485, DAN JUGA SETING SPEED PADA IR HEAD
SERVICE PARAMETER DIGUNAKAN UNTUK MENSETING WAKTU SAMPLING PADA EVC (MEASURING PERIOD)
UNTUK UJI STATIS DAPAT DIGUNAKAN 1 SECOND DAN UNTUK PENGUKURAN REAL NYA DI GUNAKAN 30
SECOND
CONVERSION BERFUNGSI UNTUK MERUBAH STANDAR COMPRESSIBILITY DAN MERUBAH BASE PRESSURE ,
BASE TEMPERATURE
UNTUK MENGSETING NILAI K FAKTOR, DENGAN CARA KLIK GAMBAR ORANG “SIMPLE VARIANT OF
PARAMETER SETUP”
NILAI K FACTOR DAPAT DI SETING DI MENU *K Conversion constants, S.N DAN AKAN MUNCUL Vm(01)
PRIMARY VOLUME (VALUE) DAN Q(01) Flow (VALUE) “ (VALUE DI SET SESUAI DENGAN NILAI YANG ADA DI
TURBIN).
UNTUK MENYAMAKAN NILAI Vm PADA VOLUME CORECTOR DENGAN NILAI YANG ADA DI TURBIN DENGAN
CARA. KLIK ACTUAL VALUE DAN Vm “PRIMARY VOLUME” VALUE EVC DI SET SAMAKAN DENGANG VALUE DI
TURBIN.