Perhitungan :
1). A = (b + mh)*h = (3,5h + 1,5h)*h = 5 h2
2). P = b + 2h (m2+1)0.5 = 3.5h + 2h(3,25)0,5 = 7.1056 h
3). R = A / P = 0.7037 h
4). Q = V*A
4.82 = 0.7*5h2
h= 1.1740 m Untuk penggambaran intake hulu
Maka :
5). w = 1/3 * h
w= 0.3913 m
6). H = h + w
H= 1.5653 m
7). Cek Aliran
Fr = (Q/A) / (g*h)0.5
Fr = 0.235 ≤ 1 (Untuk aliran sub kritis)
A= 6.891 m²
P= 8.342 m *Nomor 5,6,7 untuk hitungan sal. Pengelak
R= 0.8261 m S^1/2 0.02385
b= 4.109 m S 0.00057
T= 7.631 m
D= 0.903 m
Tabel De Vos
Debit b/h V ijin m
0 1 0.25 1
0.15 1 0.3 1
0.3 1 0.35 1
0.3 1.5 0.35 1
0.4 1.5 0.4 1
0.5 1.5 0.45 1
0.5 2 0.45 1
0.75 2 0.5 1
1.5 2 0.55 1
1.5 2.5 0.55 1
3 2.5 0.6 1
3 3 0.65 1.5
4.5 3 0.7 1.5
4.5 3.5 0.7 1.5
6 3.5 0.7 1.5
6 4 0.7 1.5
7.5 4 0.7 1.5
9 4.5 0.7 1.5
9 5 0.7 1.5
11 5 0.7 1.5
15 6 0.7 1.5
15 8 0.7 2
25 8 0.7 2
25 10 0.75 2
40 10 0.75 2
40 10 0.8 2
80 12 0.8 2
PERENCANAAN PINTU PENGAMBILAN
Data Teknis
Qintake 4.82 m3/dt
d 0.050 mm 0.055-0.06 x
h 1.174 m
d 0.00005 m
v² 0.046
v 0.214 m/dt
2.3480083
jumlah pintu 2
jumlah pilar 1
lebar pilar 0.5 m
μ 0.8
b 3.609 m
a 0.827 m
p 0.8 m 0.5-1
d 0.2 m 0.15-0.25
z 0.3 m 0.15-0.30
n 0.05 m
t 0.1
0.446
1.782 2.673306
141.460