FLOW MEASUREMENT
Q = V.A
DIMANA :
Q = FLOW RATE MELALUI PIPA
V = AVERAGE VELOCITY
A = LUAS PENAMPANG PIPA
. .D
Re
DIMANA :
RE = REYNOLDS NUMBER
= FLUID DENSITY, KG/M3
= AVERAGE FLUID VELOCITY, M/S
D = DIAMETER PIPA, M
= FLUID VISCOSITY, KG/M.S
BERDASARKAN BILANGAN REYNOLD
FLOW DAPAT DIBAGI 3
3. JIKA 2000 < RE < 10000, MAKA ALIRAN TERSEBUT BERSIFAT TRANSITION
(BENTUK ALIRAN ADALAH FLAT PARABOLIC GEOMETRY DAN DISEBUT JUGA PLUG FLOW)
ACCURACY
REPEATABILITY
LINEARITY
FLOW RANGE
RESOLUTION
ACCURACY
CONTOH :
INDIKASI FLOW RATE TERHADAP ACTUAL RATE PADA LAJU 1000 GPM ADALAH
1000 – (3 % X 1000) = 970 GPM DAN 1000 + (3% X 1000) = 1030 GPM.
PADA SPESIFIKASI VENDOR, NILAI INI DIPEROLEH DARI PENGUJIAN DAN SHOP
PABRIK PEMBUAT UNTUK RANGE, PRESSURE, TEMPERATURE, DAN VISCOSITY
FLUIDA TERTENTU
CONTOH :
SINYAL OUTPUT DARI PRIMARY ELEMENT SEBUAH DP FLOW METER TIDAK LINEAR
TERHADAP FLOW RATE,
NAMUN AKAR KWADRAT-NYA LINEAR DENGAN FLOW RATE.
LINEARITY PADA TURBINE METER DAPAT DICONTOHKAN SEBAGAI KURVA GARIS LURUS
ANTARA PERUBAHAN NILAI K-FACTOR TERHADAP FLOW RATE.
FLOW RANGE (RANGEABILITY)
CONTOH :
JIKA SEBUAH FLOW METER MEMPUNYAI TURNDOWN 40:1 DAN DIOPERASIKAN PADA
RANGE MAXIMUM 1000 GPM.
TURNDOWN RATIO = 1000 GPM/40 = 25 GPM
ARTINYA
FLOW METER TERSEBUT DAPAT MELAKUKAN PENGUKURAN DENGAN AKURAT
PADA SAAT READING MENURUN HINGGA 25 GPM.
• SHARP EDGE
TANPA PERLAKUAN KHUSUS DAPAT DIPAKAI UNTUK ALIRAN DUA ARAH.
• QUADRANT EDGE
DIPAKAI UNTUK FLUIDA DENGAN VISKOSITAS TINGGI SEPERTI SLURRY
ATAU HEAVY CRUDE, DIMANA BIASANYA BILANGAN REYNOLD-NYA <
10000.
ORIFICE FITTING
UNTUK MENAHAN ORIFICE AGAR TERPASANG DENGAN BAIK PADA PIPA, UMUMNYA
MEMAKAI FLANGE.
• SENIOR FITTING
• JUNIOR FITTING
• SIMPLEX FITTING
SENIOR JUNIOR SIMPLEX DUAL CHAMBER
SENIOR FITTING
MEMBUKA PELAT ORIFICE KETIKA PIPA SEDANG DILALUI FLUIDA DAPAT
DILAKUKAN JIKA MEMAKAI SENIOR FITTING
JUNIOR FITTING
DIPAKAI PADA APLIKASI YANG MEMPUNYAI BYPASS LINE.
SIMPLEX FITTING
HAMPIR SAMA DENGAN JUNIOR, BEDANYA ADALAH PENGANGKATAN
ORIFICE PLATE DAPAT LANGSUNG DILAKUKAN DENGAN TANGAN KOSONG
(TANPA ALAT ENGKOL SEPERTI PADA SENIOR DAN JUNIOR FITTING).
FLOW RECORDER
PADA BAGIAN INI TERDAPAT CIRCULAR CHART ATAU ROLLING STRIP DENGAN
UKURAN 12 ATAU 24 JAM BAHKAN ADA YANG BEBERAPA HARI. CHART
DIGERAKKAN SECARA ELEKTRIK ATAU SECARA JAM MEKANIK.
FIXED / VARIABLE ORIFICE PEREKAM TEKANAN DIHUBUNGKAN MELALUI TUBING (IMPULS LINE) KE DP CELLS.
DIFFERENTIAL PRESSURE PADA BEBERAPA SISTEM PENGUKUR
TYPE INI DAPAT DILIHAT MENEMPEL PADA BAGIAN BELAKANG RECORDER FRAME, YANG MEMPUNYAI DUA
RUANG YANG JELAS.
GAMBAR 9.15 MEMPERLIHATKAN PRINSIP DARI DIFFERENTIAL PRESSURE UNIT. BILA LAJU
ALIR MENINGKAT MAKA LOW PRESSURE CHAMBER MENURUN SEMENTARA HIGH PRESSURE
CHAMBER TETAP/KONSTAN.
DIFFERENTIAL PRESSURE MEASUREMENT
HAL INI HARUS DILAKUKAN BILA GAS MEMASUKI IMPELSE LINE. BILA OPERATOR MELIHAT BAHWA DP CELL
TIDAK AKURAT LAGI, HARUS DILAKUKAN PEMBERSIHAN DAHULU SEBELUM MEMANGGIL STAF MAINTENANCE.
PENCATATAN BIASANYA BEBAS DARI PERMASALAHAN. MASALAH YANG UTAMA ADALAH MEYAKINKAN
BAHWA KERTAS PENCATAT TIDAK TERLIPAT ATAU KUSUT DAN DIUSAHAKAN TETAP DATAR MENEMPEL
PADA BIDANG SUATU PERMUKAAN.
JUGA HARUS DICHECK APAKAH PULPEN YANG DIGUNAKAN BERSIH DAN MEMPUNYAI SUPLAI WARNA
DAN ISI YANG CUKUP SELAMA OPERASI BERLANGSUNG.
TINDAKAN RUTIN YANG HARUS DILAKSANAKAN :
• MEMBERSIHKAN CHART MEKANIK DRIVE CLOCK
• MEMASANG CHART YANG TEPAT DAN MENYAKINKAN BAHWA ARAH KECEPATAN ROTASI BENAR
• CHECK KEBEBASAN GERAK DARI PULPEN.
PEMBERSIHAN DP CELL
MELAKUKAN CHECK DAN OBSERVASI UNTUK MEYAKINKAN BERLANGSUNG DAN EFISIENNYA OPERASI
PENCATATAN
JENIS DIFFERENTIAL-METER YANG SERING DIGUNAKAN DALAM INDUSTRI GAS ADALAH ORIFICE METER.
UNTUK PERHITUNGAN JUMLAH GAS, AGA COMMITTEE REPORT NO. 3 MEMBERIKAN PERSAMAAN UMUM YANG
SERING DIPERGUNAKAN :
DENGAN,
QH = LAJU ALIR GAS PADA KONDISI DASAR, CFH
C' = KONSTANTA ALIRAN ORIFICE
HW S PERBEDAAN TEKANAN, DALAM INCHES AIR @ 600F
PF = TEKANAN ABSOLUT STATIK, PSIA
KONSTANTA ALIRAN ORIFICE (C') ADALAH LAJU ALIR GAS DALAM CUBIC FEET PER JAM, PADA KONDISI DASAR
(BASE), YAITU DENGAN MENGALIKAN BASIC ORIFICE FACTOR (FB) DENGAN BEBERAPA FAKTOR PENGOREKSI,
YANG DITURUNKAN MENJADI :
C' = (FB)(FR)(P)(FPB)(FTB)(FTF)(FG)(FPV)(FM)(FL)(FA)
DENGAN,
FB = FAKTOR ORIFICE, CFH FTB = FAKTOR TEMPERATUR DASAR (KONTRAK)
FR = FAKTOR REYNOLD NUMBER (VISKOSITAS) FTF = FAKTOR TEMPERATUR ALIR
Y = FAKTOR EKSPANSIPON FG = SPESIFIC GRAFITY GAS
YL = BERDASARKAN UPSTREAN STATIC PRESSURE FPV = FAKTOR SUPERCOMPRESSIBILITY
Y2 = BERDASARKAN DOWNSTREAN STATIC PRESSURE FM = FAKTOR MANOMETER (UNTUK MERCURY METER)
FPB = FAKTOR TEKANAN DASAR (KONTRAK) FL = FAKTOR LETAK PENGUKURAN
FA - FAKTOR EKSPANSI THERMAL ORIFICE
CONTOH :
SUATU ORIFOCE METER TERDIRI DARI TAPS, DAN MENGGUNAKAN UPSTREAM PRESSURE CONNECTION :
ROUND CHART TELAH DIGUNAKAN SECARA INTENSIF PADA BEBERAPA PERALATAN YANG BERHUBUNGAN
DENGAN PENGUKURAN LAJU ALIR GAS.
CIRCULAR CHART YANG BIASA DIGUNAKAN UNTUK PENCATATAN DIFFERENTIAL PRESSURE DAN STATIC
PRESSURE GAUGE UMUMNYA BERDIAMETER SEBESAR 12 IN.
TERDAPAT DUA BENTUK DASAR CHART YANG DIPERGUNAKAN, YAITU DENGAN SEKALA YANG SERAGAM ATAU
meter range
chart factor
100
CONTOH :
SUATU CHART DIPASANG DENGAN SKALA 5O IN. X 100 LB. GAUGE, YAITU :
DIFFERENTIAL RANGE, RH = 50 IN.
STATIC PRESSURE RANGE, RP = 100 PSI.
TENTUKAN :
A. DIFFERENTIAL PRESSURE, HW
B. STATIC PRESSURE, PF
SECONDARY ELEMENTS
• MELAKUKAN RECORDING.
MELALUI TAP PADA PIPA (PIPE TAP) ATAU FLANGE (FLANGE TAP).
VENTURY TUBE
MENGGUNAKAN PRINSIP BERNOULI UNTUK MERELASIKAN HUBUNGAN ANTARA FLUID VELOCITY DENGAN
PRESSURE.
KENAIKAN FLUID VELOCITY MELALUI SEBENTUK THROAT PADA DIAMETER TERTENTU, AKAN MENIMBULKAN
SELISIH TEKANAN (P) UNTUKMENDAPATKAN FLOW RATE.
FLOW METER JENIS INI DIPAKAI PADA PIPA BERUKURAN LEBIH BESAR
UNTUK APLIKASI GAS, STEAM DAN LIQUIDA BERSIH.
INSTALASI :
SEKAT-SEKAT PENUH BERISI LIQUIDA AKAN BERPUTAR DAN SETIAP PUTARAN DIHITUNG
MENGGUNAKAN COUNTER.
• EXTERNAL HOUSING,
UMUMNYA DIGUNAKAN UNTUK CRUDE OIL, LUBE OIL, DAN BAHAN-BAHAN KIMIA
DENGAN VISKOSITAS TINGGI.
DAN POLA ALIRAN YANG DISEBABKAN OLEH VALVE, ELBOW, FITTING PIPA, DLL.
GAS TURBINE METER JENIS AXIAL FLOW ADALAH YANG UMUM DIPAKAI
DI INDUSTRI.
Next