COOLER-01
T1 = 30 oC T2 = 36°C
COOLER
t2 = 40 °C t1 = 123,1202 °C
t masuk = 123,1202 ºC =
253,6163 °F
t keluar = 40 ºC =
104 °F
Fluida pendingin :
Tmasuk = 30 ºC = 86 °F
Tkeluar = 36 ºC = 96,8 °F
1. Beban Panas
Dari Yaws, 1991 diketahui Cp (Kkal/Kgmol K) rata-rata untuk masing-
masing komponen sebagai berikut:
Cp=A+BT +CT^2+DT^3(J/mol K)
Komponen
A B C D
CH3OH 40,152 0,31036 -0,0010291 1,4598E-06
H2O 92,053 -0,039953 -0,00021102 5,3469E-07
C6H60 38,622 1,0983 -0,0024897 2,2802E-06
C8H8O3 97,902 1,0367 -0,0024663 2,4373E-06
C7H603 254,4574886 0,20025823 -0,000358637 0
Neraca Panas
Bahan : Qumpan -
Qair = Qkeluar
referensi (Tref) = 25 oC
= 298 K
Komponen BM kmol/jam Cp dT Q (kJ/jam)
CH3OH 32 0,2605 1208,2350 314,6859
𝑘𝐽 𝑘𝐽
= 683.405,2634 − 102399,4609
𝑗𝑎𝑚 𝑗𝑎𝑚
𝑘𝐽 0,9478 𝐵𝑇𝑈
= 581005,8025 ×
𝑗𝑎𝑚 1 𝑘𝐽
𝐵𝑇𝑈
= 550.677,30
𝑗𝑎𝑚
2. Media Pendingin
Media pendingin yang digunakan adalah air pada suhu 86 ºF.
𝑇2
𝑄 𝑐𝑜𝑙𝑑
𝑚𝑎𝑠𝑠𝑎 𝑎𝑖𝑟 (𝑊𝑎) = ∫
𝑇1 𝐶𝑝 𝑑𝑇
𝑘𝑚𝑜𝑙 𝑘𝑔 𝑙𝑏
= 1284,454774 = 23120,18593 = 50970,7619
𝑗𝑎𝑚 𝑗𝑎𝑚 𝑗𝑎𝑚
t1 T2 t 2 T1
ΔT LMTD =
t T (Persamaan 5.14 Kern)
Ln 1 2
t 2 T1
ΔT LMTD =
253,6163 96,8 104 86
253,6163 96,8
Ln
104 86
64,1272o F
∆𝑇 = ∆𝑇 𝐿𝑚𝑡𝑑 × 𝐹𝑡
= 64,1272 𝐹 × 1
= 64,1272 𝐹
550677,2996 𝐵𝑡𝑢/𝑗𝑎𝑚
A = 60×64,1272 𝐹
= 143,1212 ft2
Menghitung Ud terkoreksi
𝑄
𝑈𝑑 𝑘𝑜𝑟𝑒𝑘𝑠𝑖 =
𝐴𝑡𝑜𝑡𝑎𝑙 × ∆𝑇𝑙𝑚𝑡𝑑
𝐵𝑡𝑢
550.677,30 𝑗𝑎𝑚
=
146,7200𝑓𝑡 2 × 64,1272 𝐹
𝐵𝑡𝑢
= 58,5283
𝑗𝑎𝑚 𝑓𝑡 2 𝐹
= 0,0216 𝑓𝑡2
(𝑂𝐷𝑜2 − 𝑂𝐷𝑖 2 )
𝐷𝑒 =
𝑂𝐷𝑖
(0,33552 − 0,29172 )
=
0,2917
= 0,0943 𝑓𝑡
𝑤𝑎
𝐺𝑎 =
𝐴𝑎
𝑙𝑏
7688,219438 𝑗𝑎𝑚
=
0,0216 𝑓𝑡2
= 356.261,30
(𝑇1 + 𝑇2)
𝑇 𝑐𝑜𝑙𝑑 𝑎𝑣𝑒𝑟𝑎𝑔𝑒 =
2
(253,6163 + 104)
=
2
= 178,8081476 F
𝑙𝑏
𝜇 = 0,9792𝑐𝑃 = 2,3696
𝑗𝑎𝑚 𝑓𝑡
𝐺𝑎 × 𝐷𝑒
𝑅𝑒 =
𝜇 𝑐𝑎𝑚𝑝
356.261,30 × 0,094 𝑓𝑡
=
𝑙𝑏
2,5471
𝑗𝑎𝑚 𝑓𝑡
= 13.183,09
𝐵𝑡𝑢
𝑘 𝑎𝑖𝑟 = 0,1051
𝑗𝑎𝑚 𝑓𝑡2 𝐹
𝐵𝑡𝑢
𝐶𝑝 𝑎𝑖𝑟 = 0,4798
𝑙𝑏 𝐹
1
𝐶𝑝 𝑎𝑖𝑟 × 𝜇 𝑎𝑖𝑟 −3
𝑆 𝑎𝑖𝑟 = ( )
𝑘 𝑎𝑖𝑟
1
−
𝐵𝑡𝑢 𝑙𝑏 3
0,4798 × 1,8558
𝑙𝑏 𝐹 𝑗𝑎𝑚 𝑓𝑡
=( )
𝐵𝑡𝑢
0,1051
𝑗𝑎𝑚 𝑓𝑡2 𝐹
= 2,26051
𝑙𝑏
𝜇𝑤 = 0,3247 𝑐𝑃 = 0,7858
𝑗𝑎𝑚 𝑓𝑡
𝜇 𝑐𝑎𝑚𝑝𝑢𝑟𝑎𝑛 0,14
ɸ=( )
𝜇𝑤
0,14
𝑙𝑏
2,3696
𝑗𝑎𝑚 𝑓𝑡
=( )
𝑙𝑏
0,7858
𝑗𝑎𝑚 𝑓𝑡
= 1,1671
𝐽𝐻 × 𝑘 × ɸ𝑠 × 𝑆
ℎ𝑜 =
𝐷𝑒
𝐵𝑡𝑢
= 162,708 𝑓𝑡2 𝐹
𝑗𝑎𝑚
3,14 × 0,25572
=
4
= 0,0513𝑓𝑡 2
Kecepatan massa
𝑊𝑘
𝐺𝑝 =
𝐴𝑝
50970,7619 𝑙𝑏/𝑗𝑎𝑚
=
0,0513 𝑓𝑡 2
𝑙𝑏
= 993352,1822
𝑗𝑎𝑚 𝑓𝑡 2
𝑡1 + 𝑡2
𝑡 𝑎𝑣𝑒𝑟𝑎𝑔𝑒 =
2
86 + 96,8
=
2
= 91,4 𝐹
𝑙𝑏
𝜇 𝑤𝑎𝑡𝑒𝑟 = 0,7668 𝑐𝑃 = 1,8558
𝑗𝑎𝑚 𝑓𝑡
𝐺𝑝 𝐼𝐷𝑖
𝑅𝑒 =
𝜇 𝑤𝑎𝑡𝑒𝑟
𝑙𝑏
993352,1822 × 0,2557 𝑓𝑡
𝑗𝑎𝑚 𝑓𝑡2
=
𝑙𝑏
1,8558
𝑗𝑎𝑚 𝑓𝑡
= 136.853,27
𝐵𝑡𝑢
𝑘 𝑤𝑎𝑡𝑒𝑟 = 0,3564
𝑗𝑎𝑚 𝑓𝑡2 𝐹
𝐵𝑡𝑢
𝐶𝑝 𝑤𝑎𝑡𝑒𝑟 = 0,9988
𝑙𝑏 𝐹
1
𝐶𝑝 𝑤𝑎𝑡𝑒𝑟 × 𝜇 𝑤𝑎𝑡𝑒𝑟 3
𝑆 𝑤𝑎𝑡𝑒𝑟 = ( )
𝑘 𝑤𝑎𝑡𝑒𝑟
1
𝐵𝑡𝑢 𝑙𝑏 3
0,9988 × 1,8558
𝑙𝑏 𝐹 𝑗𝑎𝑚 𝑓𝑡
=( )
𝐵𝑡𝑢
0,3564
𝑗𝑎𝑚 𝑓𝑡2 𝐹
= 1,7326
𝑙𝑏
𝜇𝑤 = 0,7688 𝑐𝑃 = 1,8558
𝑗𝑎𝑚 𝑓𝑡
ɸ𝑠 = 1
𝐽𝐻 × 𝑘 𝑤𝑎𝑡𝑒𝑟 𝑥 𝑆 𝑤𝑎𝑡𝑒𝑟 × ɸ𝑠
ℎ𝑖 =
𝐼𝐷𝑖
= 724,3296
ℎ𝑖×ℎ𝑜
Uc =
ℎ𝑖+ℎ𝑜
724,3296 × 162,7081
=
724,3296 + 162,7081
𝐵𝑡𝑢
= 132,8628
𝑗𝑎𝑚 𝑓𝑡2 𝐹
9. Faktor Pengotoran
Uc U D
Rd =
UcxUD
132,8628 − 58,5283
𝑅𝑑 = = 0,0090
132,8628 × 58,5283
= 0,0438 𝑓𝑡
𝐷𝑒. 𝐺𝑎
𝑅𝑒𝑎′ =
𝜇
0,0438 × 356.261,30
=
2,3696
= 6.130,85
0,264
𝐹𝑟𝑖𝑐𝑡𝑖𝑜𝑛 𝑓𝑎𝑐𝑡𝑜𝑟 (𝑓) = 0,0035 +
𝑅𝑒 0,42
0,264
= 0,0035 +
6.130,85 0,42
= 0,0102
4. 𝑓. 𝐺𝑎2 . 𝐿
𝐹𝑎 =
2.4,18 × 108 . 𝜌2 . 𝐷𝑒
= 4,8097 𝑓𝑡
𝐺𝑎
𝑉=
3600. 𝜌
356.261,30
=
3600 × 67,6788
𝑓𝑡
= 1,4561
𝑑𝑒𝑡𝑖𝑘
𝑉2
𝐹1 = 3.
2. 𝑔
1,45612
=3× = 0,0988 𝑓𝑡
2 × 32,2
(𝐹𝑎 + 𝐹1). 𝜌
𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑑𝑟𝑜𝑝 =
144
(4,8097 + 0,0988)67,6788
=
144
= 0,0987 𝑝𝑠𝑖
Inner Pipe
0,264
𝑓𝑟𝑖𝑐𝑡𝑖𝑜𝑛 𝑓𝑎𝑐𝑡𝑜𝑟 (𝑓) = 0,0035 +
𝐺𝑝. 𝐷 0,42
( 𝜇 )
0,264
= 0,0035 + = 0,0054
993352,1822 × 0,2556 0,42
( )
1,8558
4. 𝑓. 𝐺𝑝2 . 𝐿
𝐹𝑝 =
2.4,18 × 108 . 𝜌2 . 𝐼𝐷
𝐹𝑝. 𝜌
𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑑𝑟𝑜𝑝 (𝑃) =
144
3,3310 × 67,6788
= = 1,4733 𝑝𝑠𝑖
144
Annulus side
Normal pipe size (NPS) = 4 in
Schedule number = 40
Outside diameter (OD) = 4,5 in
Inside diameter (ID) = 4,026 in
= 0,2557 ft
Inner pipe
Normal pipe size (NPS) = 3 in
Schedule number = 40
Outside diameter (OD) = 3,5 in
Inside diameter (ID) = 3,068 in