Anda di halaman 1dari 57

OSP 

FTTH 
TECHNICAL SPECIFICATION
AERIAL INSTALLATIONS

1
Table of Contents
 PAGE 1 General Information OSP FTTH PROJECT_1
 PAGE 2 General Information OSP FTTH PROJECT_2 
 PAGE 3 General Information OSP FTTH PROJECT_3 
 PAGE 4 Installation Underground To Aerial
 PAGE 5 Temberang Sokong
 PAGE 6 Temberang Tarik
 PAGE 7 Pole Labeling
 PAGE 8 Pole Installation Position On Pedestrian Area_1
 PAGE 9 Pole Installation Position On Pedestrian Area_2
 PAGE 10 Pole Installation Position On Pedestrian Area_3
 PAGE 11 Cable Installation Route
 PAGE 12 ODC24 Installation On Pole
 PAGE 13 ODP Installation On Pole
 PAGE 14 Pole Color Installation
 PAGE 15 Pole Specification
 PAGE 16 Pole Installation
 PAGE 17 Pole Installation Distance
 PAGE 18 One Line Diagram Cable
 PAGE 19 Synoptic Cable
 PAGE 20 Core Management for Backbone and Feeder
 PAGE 21 Optical Fiber Cable Specification
 PAGE 22 Fiber Testing
 PAGE 23 ODC72 Labeling
 PAGE 24 ODP Labeling
 PAGE 25 Inside ODC72 Labeling
 PAGE 26 Inside ODC24 Installation
 PAGE 27 ODC24 Labeling
 PAGE 28 Standard Frame A3 As Plan Drawing For Vendor
1. Persamaan Terminology:
- Feeder -> Fiber optic dari Sub Hub/OLT ke ODC
- Distribution -> Fiber Optic dari ODC ke ODP
- Drop Cable -> Fiber Optic dari ODP ke ONT
2. 1 ODP standard adalah untuk 8 rumah, untuk kavling/tanah kosong akan menggunakan core spare yang
disediakan di ODP.
3. Untuk lebar jalan >12 meter jalan raya menggunakan tiang & ODP dimasing masing sisi jalan.
4. FO Feeder (OLT to ODC) jumlah core harus 264 core dengan design Planning MNC Kabel Mediakom.
5. Kabel yang digunakan untuk input 1 ODC adalah 48 core.
6. Dalam Gambar As Plan harus tergambar jelas info dan legend seperti format dibawah :
Keterangan Gambar/Legend, Posisi ODC, ODP & Handhole, Jalur kabel serta jalur pembagian IKR (untuk
Underground sampai As depan/antara 2 rumah), Nama ODP.
7. Kode ODC:
Jenis ODC . Kode Kelurahan . Nama RW . No ODC .
Contoh: ODC72.KYP.01.01
Penjelasan : ODC 72 untuk kelurahan Kayu putih RW.01, ODC yang pertama
8. Kode ODP:
Kode Kelurahan . Nama RW . No ODC. No Spliter di ODC - No Output spliter di ODC.
Contoh: KYP01.01.01.01
KYP01.01.01.01
Coding Increment untuk No.output Spliter di ODC (1 s/d 8)
Coding Increment untuk No. Spliter ODC Ke_01
Coding Increment untuk No.ODC Ke_1
Coding Increment untuk Nama RW_01
Coding Increment untuk Lokasi kelurahan_(Kayu Putih)
Type ODC yang digunakan untuk jenis jaringan kabel udara adalah ODC 72 core.
Type ODC yang digunakan untuk jenis jaringan kabel tanam adalah ODC 96 s/d 512
Core tergantung dari banyaknya homepass yang di layani.
GENERAL INFORMATION OSP FTTH PROJECT_1
PAGE 1
9. Seluruh core output spliter pada ODC yang menuju ke spliter distribusi ODP harus di terminasi di ODC dengan tidak lebih
dari dua titik sambungan yaitu 1 di ODC (output spliter ODC) dan 1 lagi di input spliter pada ODP.
Contoh: apabila ada 512 HP, menggunakan spliter pada ODC 1:8 sejumlah 8 unit dan 64 unit spliter pada
ODP type 1:8 ODP per 8 rumah maka membutuhkan 8 + 64 = 72 spliter type 1:8 modular, dimana tiap spliter ODP
terdapat 1 core yang diterminasi pada pigtail type SC/APC untuk input dan 64 core diterminasi pada output spliter OD C,
sehingga total terminasi adalah 64 x 2 +12 (input ODC+sphare) = 140 core.
10. Apabila jumlah rumah yang akan dicover ODC melebihi 512 HP untuk type jaringan kabel udara, maka bisa propose
menggunakan 2 ODC dalam 1 tempat atau titik berbeda tergantung dari design, atau pada type jaringan kabel tanam
menggunakan type ODC yang lebih besar.
11. Type ukuran ODC yang digunakan disesuaikan dengan jumlah rumah yang dicover.
12. Lokasi ODC propose ditanah kosong dekat Gerbang masuk cluster/Pos security atau di area utilitas yang strategis.
13. Jenis Konektor dan adapter yang digunakan di ODC adalah type SC/APC
14. Pemasangan ODC atau ODP harus menghadap jalan.
15. Penamaan atau labeling pada box harus sama dengan kode ODC atau ODP
16. Basemap menggunakan warna grey, no rumah menggunakan warna hitam.

GENERAL INFORMATION OSP FTTH PROJECT_2


PAGE 2
Under Ground:
1. Pada jaringan Feeder setiap crossing harus ada Handhole ukuran 80 x 80 x 80 cm di kedua sisi.
2. Pada jaringan distribusi setiap ODC harus ada Handhole ukuran 60 X 60 x 60 cm.
3. Pada Jaringan distribusi setiap ODP harus ada Handhole ukuran 40 x 40 x 40 cm dan ditempatkan di batas persil rumah
pada jalan.
4. Pada Jaringan distribusi setiap batas persil rumah per 2 rumah harus ada bak control dengan ukuran 20 x 20 x 20 cm,
yang diperuntukan sebagai jalur IKR untuk 2 rumah dengan jalur pipa diameter 1 inchi menuju ODP,yang berbeda
dengan jalur distribusi menggunakan HDPE.
5. Pada Jaringan distribusi pada crossing tidak diperlukan handhole kedua sisi (HDPE tanam langsung), kecuali ada
jalur IKR.
6. Tidak diijinkan ada crossing didepan rumah, kecuali sudah terdapat existing handhole.

Aerial:
1. Kabel yang digunakan adalah type Aerial/Kabel Udara/menggunakan type ADSS G652.
2. Untuk Feeder, setiap 5 tiang harus terdapat spare kabel dengan panjang 15 meter.
3. Jumlah kabel aerial dari ODC maksimal dalam 1 tiang adalah 5 kabel, apabila melebihi harus melalui underground
sampai ke tiang dimana terdapat FAT.
4. Drop Cable dari tiang tidak boleh langsung melintang kearah rumah, melainkan harus menyusuri Distribution Cable
kemudian baru berbelok didepan rumah menggunakan Q-Span. Messenger yang menempel di rumah juga diikat
menggunakan screw eye hanger.
5. Pemasangan ODP adalah di Tiang, dimana posisi pemasangan tiang harus berdekatan atau bersebelahan dengan
tiang PLN atau Telkom yang sudah ada serta harus dikordinasikan & mendapat persetujuan dari MKM dan
pengelola kawasan.

GENERAL INFORMATION OSP FTTH PROJECT_3


PAGE 3
85
Slack Support

Spare In : 10 m
Spare Out : 10 m

85
Stainless Steel Belt
Buckle

411
Stainless Steel Belt
Buckle

Handhole 40x40x40 cm
Berfungsi sebagai bak kontrol
peralihan jalur

25
25

Pipa Galvanis
2 x 1,25 inch
120

Bellmouth

PERALIHAN JALUR KABEL TANAM KE KABEL UDARA


SCALE :
N.T.S

INSTALLATION UNDERGROUND TO AERIAL


PAGE 4
63.5

137
101.6

137
Klem dobel
127.0

Tiang Penahan 4"

700 Fondasi, Beton 1:2:3

426 45

Muka Tanah
50

50
135

Dasar penahan fondasi :


batu kali

TEMBERANG SOKONG
PAGE 5
Kawat Baja 10 mm

Lapis HDPE Subduct


40 mm panjang 3 m

Jepit / Klip Kabel

Angkur galvanis 16mm, panjang 75 cm


200

Muka Tanah Muka Tanah


1500

750

TEMBERANG TARIK
PAGE 6
PELABELAN TIANG BERDASARKAN NO. TIANG YANG
TERCANTUM PADA AS BUILT DRAWING.
5 cm format : ABC00.000
ABC - Nama Kelurahan,
format = ABC00.000,

00 - No. RW, PENULISAN LABEL TEGAK LURUS MENGHADAP KE ARAH


. ATAS. AWAL LABEL PADA 10 cm DARI SAMBUNGAN TIANG

SAG17.1
10 cm
000 - No.Tiang - PERTAMA
1, mulai dari ODC, diurutkan
sesuai jalur, kemudian PELABELAN DILAKUKAN DENGAN CAT SEMPROT ATAU
dilanjutkan ke jalur berikutnya. MENGGUNAKAN SPON
Penomoran dilakukan per ODC
dengan meneruskan urutan no. UKURAN :
dari ODC sebelumnya. 5 cm
LEBAR : 5 cm
TIPE HURUF : ARIAL BLACK

SAG17.1
10 cm
WARNA : PUTIH
detil 1
detil 1

PEMBERIAN 2 RING
BERWARNA BIRU LANGIT

UKURAN :
TEBAL RING & JARAK ANTAR
RING : 2 CM
JARAK DARI UJUNG BAWAH
2 cm TIANG : 2 CM
2 cm

2 cm
20 cm

14 cm

detil 2 20 cm
2 cm

2 cm

2 cm

14 cm

detil 2

PAVING BLOK JALAN RAYA

POLE LABELING
PAGE 7
63,5
63,5

1370

1370
101,6
101,6
1370

1370
127
127
7000

7000
4260

4260
TYPE
TYPE
SALURAN
SALURAN
TERBUKA
TERBUKA
500

500
PAVING BLOK JALAN RAYA
PAVING BLOK JALAN RAYA
700

700
1350

1350
600
600

POLE INSTALLATION POSITION ON PEDESTRIAN AREA


PAGE 8
63,5 63,5

1370
1370
101,6 101,6

1370
1370

127 127

7000
7000

4260
4260

500
BETON
500

JALAN RAYA KERAMIK BETON JALAN RAYA


TYPE
700

SALURAN
TERTUTUP TYPE

700
SALURAN
TERTUTUP

1350
1350

600

600

POLE INSTALLATION POSITION ON PEDESTRIAN AREA


PAGE 9
penyebrangan kabel
menggunakan tiang 9 m

pada tarikan lurus tanpa


tracking messenger pada 2
gawang kabel antara 2 tiang
Tiang 9 m Tiang 9 m
yang di tracking.
messenger
pada tarikan lurus tracking
pemasangan accessories pada pole strap 2,5 inch
messenger per 3 gawang
j-clamp
posisi antara 2 tiang yang kabel fiber optik
messenger-nya di-tracking buldog grip
pemasangan accessories pada
span wartel 16 mm posisi tracking messenger

cable ties 45 cm

Tiang 7 m
Tiang 7 m

Pedestrian Pedestrian JALAN RAYA Pedestrian Pedestrian

POLE INSTALLATION POSITION ON PEDESTRIAN AREA


PAGE 10
CABLE INSTALLATION ROUTE
PAGE 11
ODC24
Diletakkan

3
berpunggungan
pada tiang

Masing-masing
ODC24 dipasang
sesuai standar
pemasangan ODP/FAT.
Masing-masing diawali
pemasangan slack
support dengan panjang
slack sekitar 15 m dan
kemudian ODC diletakkan
di atasnya.

ODC24 INSTALLATION ON POLE


PAGE 12
Fixed Clamp

300
Suspension

850
Slack Support Slack Support

ODC+ODP 64,25

Slack Kabel Slack Cabel


15 m Kiri-Kanan 15 m Kiri-Kanan

ODP INSTALLATION ON POLE


PAGE 13
Page 14
TIANG 7 M TIANG 9 M

200 cm
OD= 2,5 inch
tebal : 2,9 mm

137 cm
OD= 2,5 inch

30 cm
tebal : 2,9 mm
pasak

200 cm
30 cm
OD= 4 inch
pasak
tebal : 3,2 mm

137 cm
OD= 4 inch

30 cm
tebal : 3,2 mm pasak

900 cm

700 cm
700 cm

30 cm

pasak

OD= 5 inch
tebal : 4,5 mm
OD= 5 inch

500 cm
tebal : 4,5 mm
426 cm

25
lakop
pelapisan
25

oleh pipa
4,5 mm

25
160 cm
120 cm

25

POLE SPECIFICATION
PAGE 15
TIANG 7 M TIANG 9 M
OD= 2,5 inch

OD= 2,5 inch

OD= 4 inch

OD= 4 inch

900 cm
700 cm

OD= 5 inch

OD= 5 inch
10 cm
10 cm

MUKA

25 cm
COR
25 cm

COR TANAH

25 cm
25 cm

160 cm
120 cm

POLE INSTALLATION
PAGE 16
40 - 45. meter 40 - 45 meter
. 40 - 45 meter
. 40 - 45. meter

Fixed Clamp

300
96 Core F.O. 48 Core F.O. 48 Core F.O.
96 Core F.O.

85

85

85

85

850
Slack Support Slack Support Slack Support

CLOSURE 296c CLOSURE 96c ODC/ODP

Slack Cabel Slack Cabel Slack Kabel


15 m Kiri-Kanan 15 m Kiri-Kanan 15 m Kiri-Kanan
85

85

85

85
264 Core F.O.

Stainless Steel Belt


Buckle
411

411

411

411
Stainless Steel Belt
Buckle

Handhole 40x40x40 cm
Berfungsi sebagai bak kontrol
peralihan jalur
25

25

25

25
25

25

25

25
Pipa Galvanis
2 x 1,25 inch
120

120

120

120
Bellmouth

PERALIHAN JALUR KABEL TANAM KE KABEL UDARA


SCALE :

POLE INSTALLATION DISTANCE


PAGE 17
CYBER LN.10

CIRANJANG

PLAZA CYBER LN.3


INDONESIA ARIOBIMO
MNC
B CYBER A

HH.01 HH.06
SJ.96/01 SJ.96/02 SJ.96/03 A
B

INDOVISION 2

MCR RCTI
INDOVISION 1 GD. KOPERASI
B A

SJ.96/07 SJ.96/06 SJ.96/05


B SJ.96/04 A

ONE LINE DIAGRAM CABLE


PAGE 18
MNC PLAZA
INDONESIA ARIOBIMO CYBER
CIRANJANG

KFD 24" - 2.823 m

KFD 96" - 3.708m

KFD 96" - 3.264m KFD 96" - 3.044m


HH. 75
KFD 96" - 2.456m KFD 96" - 3.016m KFD 96" - 3.319m

HH. 11 HH. 27 HH. 33

HH. 01 HH. 06
JOINT ALL CORE
HH. 18 HH. 22 JOINT ALL CORE JOINT ALL CORE

KFD 96" - 1.574m KFD 96" - 3.296m

RCTI
INDOVISION 1
INDOVISION 2 GD. KOPERASI

KFD 24" - 637m


KFD 96" - 3.259m

KFD 96" - 3.939m

KFD 96" - 3.174m KFD 96" - 3.191m KFD 96" - 3.307m

HH. 68 HH. 62 HH. 56 HH. 35


JOINT ALL CORE JOINT ALL CORE
HH. 50 HH. 44 JOINT ALL CORE

SYNOPTIC CABLE
PAGE 19
Kabel yang digunakan dalam setiap tarikan adalah kabel 264 (22 tube @12 core)

Dari OLT keluarannya 2 kabel (2xFO264), rincian penggunaan masing-masing kabel :


8 Tube sebagai Backbone (Menghubungkan OLT dengan BRAS, harus kembali dari BRAS menuju BRAS lagi /
membentuk ring)
14 Tube sebagai Feeder (supply ke ODC-ODC di tiap RW, idealya untuk RW yang berhomepass <512 dapat
dicover oleh 1 ODC. Input untuk 1 ODC = 1 Tube kabel Feeder)
1 Tube untuk input tiap ODC 72 core hanya dipakai 8 core, jadi masih sisa 4 core yang dapat dimanfaaatkan
untuk input FTTB
1 tarikan kabel dari 1 BRAS kembali ke BRAS lagi dapat mengcover minimal/ efektif 8 OLT, maksimal 16 OLT
(dengan syarat HP tidak melebihi HP maksimal kapasitas OLT).
Kapasitas OLT dihitung sbb :
1 ODP = 8 HP
1 ODC = 64 ODP x 8 HP = 512 HP
1 OLT = 2 x 14 ODC x 512 HP = 14336 HP
1 BRAS =2 x 8 OLT x 14336 HP = 229376 HP
Penembatan OLT sebaiknya berada di tengah-tengah dari beberapa target perumahan-perumahan yang akan
dicover. Idealnya dari tiap tarikan menyupply 14 ODC, jadi total supply = 28 ODC.

CORE MANAGEMENT FOR BACKBONE & FEEDER


PAGE 20
PAGE 21
PAGE 22
FDT TYPE : GXF147-FDT2115D-72

PIGTAIL CORE INPUT TO


ODP FEEDER

SPLITTER RACK
1
1
2

KASET 3
FEEDER 2
KASET SAMBUNGAN 4

CORE INPUT 5
3
6

7
4
8

9
5
10
KASET SAMBUNGAN
11
CORE OUTPUT 6
KASET 12

DISTRIBUSI
13 7

14
PIGTAIL KABEL OUTPUT
TO ODP DISTRIBUSI 15 8

16

17 9

18
D C B A

SPLITTER 1:8 x 5
KABEL DISTRIBUSI
KABEL FEEDER KABEL DISTRIBUSI
KABEL FEEDER

ODC 72 LAYOUT DIAGRAM 01 ODC 72 LAYOUT DIAGRAM 02


SCALE : N.T.S SCALE : N.T.S

INSIDE ODC LABELING


PAGE 25
ODP TYPE : ZTE - ZXA 10 ODN

SPLITER 1 PORT 1

XXX00.00.00.00 SPLITER 1 PORT 5


SPLITER ODC 1 PORT 1-8
XXX00.00.00.00 SPLITER ODC 2 PORT 1-8
SPLITER 1 PORT 2 SPLITER ODC 3 PORT 1-8

XXX00.00.00.00 SPLITER 1 PORT 6

XXX00.00.00.00 SPLITER 1 PORT 3

XXX00.00.00.00 SPLITER 1 PORT 7

XXX00.00.00.00
SPLITER 1 PORT 4

XXX00.00.00.00 SPLITER 1 PORT 8

XXX00.00.00.00 SPLITER 2 PORT 1

XXX00.00.00.00 SPLITER 2 PORT 5

XXX00.00.00.00
SPLITER 2 PORT 2

XXX00.00.00.00 SPLITER 2 PORT 6


SPLITER ODC 1
XXX00.00.00.00 SPLITER 2 PORT 3

XXX00.00.00.00 SPLITER 2 PORT 7

XXX00.00.00.00 SPLITER 2 PORT 4

XXX00.00.00.00 SPLITER 2 PORT 8

XXX00.00.00.00 SPLITER 3 PORT 1


TX . C X
XXX00.00.00.00 SPLITER 3 PORT 5 TX . C X
XXX00.00.00.00 SPLITER 3 PORT 2
TX . C X
XXX00.00.00.00 SPLITER 3 PORT 6 SPLITER ODC 2
XXX00.00.00.00 SPLITER 3 PORT 1-8
SPLITER 3 PORT 3
SPLITER 2 PORT 1-8
XXX00.00.00.00 SPLITER 3 PORT 7
SPLITER 1 PORT 1-8
XXX00.00.00.00 SPLITER 3 PORT 4

XXX00.00.00.00 SPLITER 3 PORT 8

XXX00.00.00.00

SPLITER ODC 3

KONEKTOR ATAS

KABEL FEEDER KABEL DISTRIBUSI KABEL FEEDER KABEL DISTRIBUSI

Masukan Keluaran Masukan Keluaran


maksimum maksimum maksimum maksimum
3 core 24 core 3 core 24 core

ODC 24 mini memiliki : Kapasitas maksimum pelanggan terlayani sesuai port


1 lubang masukan kabel splitter cascade 2 adalah - satuan port:
1 lubang keluaran kabel 24 x 8 = 192 port pelanggan - subscriber .

Total Penggunaan Core maksimum pada ODC 24 ODC 24 dapat digunakan secara serial :
adalah sbb. : disesuaikan jumlah core pada kabel distribusi
Masukan maksimum 3 core yang digunakan.
Keluaran maksimum 24 core
Total penggunaan maksimum = 27 core

Kapasitas maksimum splitter digunakan :


3 spliter pada modul sebagai splitter cascade 1
24 splitter pada outside plant sebagai splitter
casacade 2

INSIDE ODC24 INSTALLATION


PAGE 26
ODC24 = modifikasi ODP TYPE : ZTE - ZXA 10 ODN

keluaran masukan
SPLITER 1 PORT 1
DETIL 2
XXX00.00.00.00 SPLITER 1 PORT 5
SPLITER ODC 1 PORT 1-8
XXX00.00.00.00 SPLITER ODC 2 PORT 1-8
SPLITER 1 PORT 2 SPLITER ODC 3 PORT 1-8

XXX00.00.00.00 SPLITER 1 PORT 6


keluaran masukan
XXX00.00.00.00 SPLITER 1 PORT 3

XXX00.00.00.00 SPLITER 1 PORT 7

XXX00.00.00.00
SPLITER 1 PORT 4

XXX00.00.00.00 SPLITER 1 PORT 8

XXX00.00.00.00
SPLITER 2 PORT 1

XXX00.00.00.00 SPLITER 2 PORT 5

XXX00.00.00.00
SPLITER 2 PORT 2

XXX00.00.00.00 SPLITER 2 PORT 6


SPLITER ODC 1
XXX00.00.00.00 SPLITER 2 PORT 3

XXX00.00.00.00 SPLITER 2 PORT 7

XXX00.00.00.00 SPLITER 2 PORT 4

XXX00.00.00.00 SPLITER 2 PORT 8


masukan
XXX00.00.00.00 SPLITER 3 PORT 1
TX . C X
XXX00.00.00.00 SPLITER 3 PORT 5 TX . C X
XXX00.00.00.00 SPLITER 3 PORT 2
TX . C X
XXX00.00.00.00 SPLITER 3 PORT 6 SPLITER ODC 2
XXX00.00.00.00 SPLITER 3 PORT 1-8
SPLITER 3 PORT 3
SPLITER 2 PORT 1-8
XXX00.00.00.00 SPLITER 3 PORT 7
SPLITER 1 PORT 1-8
XXX00.00.00.00 SPLITER 3 PORT 4

XXX00.00.00.00 SPLITER 3 PORT 8


keluaran
XXX00.00.00.00
DETIL 1
DETIL 3
SPLITER ODC 3

KONEKTOR ATAS

KABEL FEEDER KABEL DISTRIBUSI KABEL FEEDER KABEL DISTRIBUSI

RAK SISI LUAR RAK SISI DALAM


SKALA : N.T.S SKALA : N.T.S

Pelabelan dilakukan pada tiap posisi berlabel pada gambar.


Tiap posisi berlabel diterangkan secara detil pada gambar Detil
1, Detil 2 dan Detil 3 pada halaman berikutnya.
Pelabelan dilakukan dengan Cable Ties tipe khusus pelabelan

ODC24 LABELLING
PAGE 27
AS PLAN DRAWING RETAIL DISTRIBUTION
FIBER TO THE HOME

N G AS PLAN NUMBER
DATE
:
:

VISUAL
STANDARD WARNA TUBE
WARNA NO. TUBE KAP. KABEL
I
= BIRU
= ORANGE =
= HIJAU

= COKLAT =
=

=
TUBE 1
TUBE 2
TUBE 3

TUBE 4
6 CORE
12 CORE

24/48 CORE

A W A
= ABU

= PUTIH
=

=
TUBE 5

TUBE 6

R R E Logo Of
VENDOR

D or
= MERAH = TUBE 7

= HITAM = TUBE 8 96 CORE CONTRACTOR


= KUNING =
= UNGU
= PINK
= CYAN
=
=
=
TUBE 9
TUBE 10
TUBE 11
TUBE 12 144 CORE

L _ _A LEGEND QUANTITY

= PERAK
= EMAS
= BIRU
=
=
=
TUBE 14
TUBE 15
TUBE 16
A
C U T G
HUB OLT

FIXING SLACK

I
= ORANGE = TUBE 17 JOIN CLOSURE

IN A
= HIJAU = TUBE 18 ODC ODC/FDT/FIBER DISTRIBUSTION TERMINAL

= COKLAT =

= ABU

= PUTIH
=

=
TUBE 19

TUBE 20

TUBE 21
H Y O ODP

ODC
ODP/FAT/FIBER ACCESS TERMINAL

ODC DISALLOWED

C
ODP ODP DISALLOWED

W E
= MERAH = TUBE 22 264 CORE

VISUAL
STANDARD WARNA CORE
WARNA NO. CORE

E L A A R
HANDHOLE EXISTING
HANDHOLE 80X8080 CM
HANDHOLE PIT 60X60X60 CM

T
HANDHOLE PIT 40X40X40 CM
= BIRU CORE 1 CABLE RISER

R A
= CR

= ORANGE = CORE 2
BA RILLING ASPHALT (BORING ASPAL)

GA EXCAVATION ASPHALT (GALI ASPAL)


= HIJAU = CORE 3

D
GT EXCAVATION LAND (GALI TANAH)
= COKLAT = CORE 4
GR
EXCAVATION GRASS (GALI RUMPUT)

_
= ABU = CORE 5

L T_
POLE 9 METER
= PUTIH = CORE 6 POLE 7 METER

= MERAH = CORE 7 GALVANIZED PIPE 6 METER


POLE 9 DISALLOWED
= HITAM = CORE 8
POLE 7 DISALLOWED

A
= KUNING = CORE 9
DROP WIRE
= UNGU = CORE 10 FIBER 6/2T
FIBER 12/2T

IC U G
= PINK = CORE 11
FIBER 24/4T
= CYAN = CORE 12 FIBER 48/4T
FIBER 72/6T

IN
FIBER 96/8T
KETERANGAN:
FIBER 144/12T

H O
FIBER 264/22T
HOMEPASS

C Y
HUB AREA :

A W A
NODE AREA

CITY AREA
:

TUBE KABEL

E R E
PROVINCE AREA :

ASCERTAIN :

T A
CORE KABEL
JAKET KABEL
PT. MNC KABEL MEDIAKOM PT. MNC KABEL MEDIAKOM

ODP/FAT
ALOKASI CORE IN SPLITER
JUMLAH HOMEPASS YANG DILAYANI

L _ D A R OSP DIVISION HEAD OSP DIVISION

L _
JUMLAH DAN SPLITER YANG DIPASANG

ODP
CONSENT :
NAMA ODP/FAT

ALOKASI CORE:
KAPASITAS CORE KABEL
NO. TUBE KABEL
FOxx-Tx-Cx

A
C U T PT. MNC KABEL MEDIAKOM PT. MNC KABEL MEDIAKOM

I
NO. CORE KABEL

OSP PLAN DEPT. MANAGER OSP PLAN DEPT. PIC REGION

KAPASITAS KABEL, TUBE DAN CORE


A. 6 CORE / 1 TUBE, 1 TUBE = 6 CORE
B. 12 CORE / 2 TUBE, 1 TUBE = 6 CORE
H Y O DRAWING NAME SCALE PAGE

C
NTS
C. 24 CORE / 4 TUBE, 1 TUBE = 6 CORE
OF
D. 48 CORE / 4 TUBE, 1 TUBE = 12 CORE

A
SHEET
F. 96 CORE / 8 TUBE, 1 TUBE = 12 CORE

E
G. 144 CORE / 12 TUBE, 1 TUBE = 12 CORE
H. 264 CORE / 22 TUBE, 1 TUBE = 12 CORE
PT. MNC KABEL MEDIAKOM

T L REVISION

APPROVED BY

CHECKED BY

DRAWN BY
NAME DATE SIGNATURE / CP

CONTACT PERSON

PAGE 28
ADD
TECHNICAL SPECIFICATION DESIGN
TECHNICAL SPESIFICATION

detil A detil A

100
Tutup Pipa Welded

100
detil B

100
detil C
Tutup Pipa Welded NOTES/ REMARKS

detil B

100
detil C
Panjang Tiang :
6m
Diameter :
detil D detil E Approved By :
PT. MNC KABEL MEDIACOM

Tebal : > 80 Irisan Tiang


6000

3,2 mm
ANTONIUS DARYANTO

200
> 80 mm
OVAN SASETYO BHANTOLO
DRAWN CHECKED CHECKED

tebal = 3,2 mm
3,2

200
Jaka Sudana Andri F.

PROJECT

FTTH NETWORK

DRAWING TITLE

200
IRON POLE 6m
detil D
kuncian DRAWING NAME

angkur kuncian
200

SUBSCRIBER POLE

angkur SITE ID LOCATION


200

200
ID
46,98 INDONESIA AREA
200

kuncian SCALE REVISED


angkur No. DATE SIGNATURE

50 NTS 1. -
200
46,98

50 NO. REGISTER Sheet No.: 2


of : 2
200
200 FTTH 001
A3
50
detil B
TECHNICAL SPESIFICATION

tampak
74
atas
detil F 27
20
NOTES/ REMARKS

pigtail 30 30
Cor hingga 10 10
ketinggian 20 cm
dari muka tanah
dan dengan 50
> 80 > 80
lebar 5 cm dari 30 30 40 40

200
lingkar luar tiang

40

40

40

40
tampak samping tampak depan
200

tampak atas
detil C
Approved By :
PT. MNC KABEL MEDIACOM

Muka Tanah ANTONIUS DARYANTO


200

Dilapis karet hitam OVAN SASETYO BHANTOLO


DRAWN CHECKED CHECKED
1000

50
200

Jaka Sudana Andri F.

50 > 80 PROJECT

Tiang 40
FTTH NETWORK
ditanam
200

DRAWING TITLE

hingga

50
4 IRON POLE 6m
kedalaman DRAWING NAME

140
100 cm SUBSCRIBER POLE

140
200

SITE ID LOCATION
50
ID INDONESIA AREA
SCALE REVISED
No. DATE SIGNATURE
1. -
NTS

NO. REGISTER

tampak samping tampak depan


Sheet No.: 2
of : 2
FTTH 001
A3
TECHNICAL SPESIFICATION

SINOPTIK 48 core DUA ODC24 NOTES/ REMARKS

ODC 24B ODC 24A


splitter 3 splitter 1
1:8 1:8

splitter 4 splitter 2
1:8 1:8

splitter B splitter A
1:8 1:8

Approved By :
PT. MNC KABEL MEDIACOM

RAFDIAN RASYID

tube tube
1 1
WAWAN JULIAWAN
DRAWN CHECKED CHECKED
tube tube
feeder 2 2 distribution
48 Jaka Sudana Andri F.
48 core
core tube tube
PROJECT

3 3 FTTH NETWORK

tube tube DRAWING TITLE

4 4 ODC24 SPESIFICATION
DRAWING NAME

DUAL ODC24
48 CORE CABLE SYNOPTIC

SITE ID LOCATION

ID INDONESIA AREA
SCALE REVISED
No. DATE SIGNATURE
1. -
NTS

NO. REGISTER Sheet No.: 2


of : 2
FTTH 001
A3
TECHNICAL SPESIFICATION

SKEMA PENGGUNAAN 2 ODC24


Untuk : NOTES/ REMARKS

tarikan 1 kabel, 32 splitter, 256 pelanggan

ODC24.XXX00.01 ODC24.XXX00.02

Approved By :
PT. MNC KABEL MEDIACOM

RAFDIAN RASYID

Feeder : Distribusi :
48 core 32 core WAWAN JULIAWAN
DRAWN CHECKED CHECKED
Spare :
ODC24.01 ODC24.02 ODC24.01-02 16 core
Jaka Sudana Andri F.
Masukan : 3 core Masukan : 3 core Masukan : 6 core PROJECT
Keluaran : 16 core Keluaran : 16 core Keluaran : 32 core
Total penggunaan : 16 core Total penggunaan : 16 core Total penggunaan : 32 core FTTH NETWORK
Total spare output : 8 core Total spare output : 8 core Total spare output: 16 core
Total spare idle : 8 core Total spare idle : 8 core Total spare idle : 16 core DRAWING TITLE

Pelanggan berdasarkan total Pelanggan berdasarkan total Pelanggan berdasarkan total ODC24 SPESIFICATION
port splitter = 16 x 8 = 128 port splitter = 16 x 8 = 128 port splitter = 32 x 8 = 256 DRAWING NAME
DUAL ODC24
DISTRIBUTION SCHEME
WITH 48 CORE CABLE
SITE ID LOCATION

LIHAT SINOPTIK ID INDONESIA AREA


SCALE REVISED
No. DATE SIGNATURE
1. -
NTS

NO. REGISTER Sheet No.: 2


of : 2
FTTH 001
A3
TECHNICAL SPESIFICATION

SINOPTIK 48 core SATU ODC24


NOTES/ REMARKS

ODC 24
splitter 1
1:8

splitter 2
1:8

splitter 3
1:8 Approved By :
PT. MNC KABEL MEDIACOM

RAFDIAN RASYID

WAWAN JULIAWAN
DRAWN CHECKED CHECKED
tube tube
1 1
Jaka Sudana Andri F.

PROJECT

tube tube
feeder FTTH NETWORK
2 2 distribution
48 DRAWING TITLE

48 core
core tube tube ODC24 SPESIFICATION

3 3 DRAWING NAME

SINGLE ODC24
48 CORE CABLE SYNOPTIC

tube SITE ID LOCATION

4 ID INDONESIA AREA
SCALE REVISED
No. DATE SIGNATURE
1. -
NTS

NO. REGISTER Sheet No.: 2


of : 2
FTTH 001
A3
TECHNICAL SPESIFICATION

SKEMA PENGGUNAAN 1 ODC24


Untuk : tarikan 1 kabel, 24 splitter, 192 pelanggan
NOTES/ REMARKS

ODC24.XXX00.01 XXX00.01.01.01 XXX00.01.03.08

Approved By :
PT. MNC KABEL MEDIACOM

Feeder : Distribusi : RAFDIAN RASYID


48 core 24 core
ODC24.01 ODP XXX00.01.01 ODP XXX00.03.07-08
WAWAN JULIAWAN
Masukan : 3 core Masukan : 1 core Masukan : 2 core DRAWN CHECKED CHECKED
Keluaran : 24 core Keluaran : 8 core - dropwire Keluaran : 16 core - dropwire
Total penggunaan : 24 core Total penggunaan : 1 core Total penggunaan : 2 core
Total spare output : 12 core Total sisa core : 23 core Total sisa core : - core Jaka Sudana Andri F.

Total idle core : 12 core PROJECT

Pelanggan berdasarkan total Pelanggan berdasarkan total Pelanggan berdasarkan total


port splitter = 24 x 8 = 192 port splitter = 1 x 8 = 8 port splitter = 2 x 8 = 16 FTTH NETWORK

DRAWING TITLE

ALOKASI CORE ALOKASI CORE ALOKASI CORE ODC24 SPESIFICATION


pada kabel feeder pada kabel distribusi pada kabel distribusi
DRAWING NAME
SINGLE ODC24
t1c1-t1c3 - input t1c1 - input ODC t3c7 - input ODC DISTRIBUTION SCHEME
WITH 48 CORE CABLE
t1c1-t1c8, t2c1-t2c8, t1c1 - output - kabel distribusi t3c7 - output - kabel distribusi
SITE ID LOCATION
t3c1-t3c8 - output
t1c9-t1c12, t2c9-t2c12, t3c8 - input ODC ID INDONESIA AREA
t3c9-t3c12- spare t3c8 - output - kabel distribusi SCALE REVISED
No. DATE SIGNATURE
1. -
NTS

NO. REGISTER Sheet No.: 2

LIHAT SINOPTIK FTTH 001


of

A3
: 2
TECHNICAL SPESIFICATION

PERBANDINGAN
SKEMA PENGGUNAAN ODC24 DENGAN ODC72
BACKBONE-FEEDER ODC ODP NOTES/ REMARKS

Pada ODC72 :
Input : 8 core untuk 8 splitter cascade 1
spare : 4 core
XXX00.01.01.01 XXX00.01.03.08
output :
tarikan 1 : 24 core untuk 24 splitter
Distribusi :
cascade 2 = 192 port
24 core untuk 24 splitter cascade 2
Sisa : tarikan 2 : 32 core untuk 32 splitter
24 core
cascade 2 = 256 port
tarikan 3 : 8 core untuk 8 splitter cascade
Feeder level 1 / Backbone :
264 core dengan 168 core masukan 2 = 64 port

XXX00.01.04.01 XXX00.01.07.08 Total port = 192 + 256 + 64 = 512 port


ODC72
Port sudah maksimal, untuk penambahan
Feeder level 2 :
Distribusi :
32 core untuk 32 splitter cascade 2 perlu ditambahkan ODC baru.
48 / 96 /144 / 264 core dengan 12 core Sisa :
masukan 8 splitter cascade 1 dan 4 core spare 16 core
Enclousure ODC72.XXX00.01
Jadi :
ODC 72 :
Input max. (on) = 8 core
XXX00.01.08.01 XXX00.01.08.08
Output max. (on) = 64 core
Approved By :
Port max. (on) = 512 port PT. MNC KABEL MEDIACOM

Distribusi :
8 core untuk 8 splitter cascade 2
Sisa :
40 core

Pada ODC24 :
RAFDIAN RASYID
Input : 8 core untuk 8 splitter cascade 1
spare : 4 core
output :
ODC24.XXX00.01 XXX00.01.01.01 XXX00.01.03.08
tarikan 1 : 24 core untuk 24 splitter
cascade 2 = 192 port WAWAN JULIAWAN
tarikan 2 : 32 core untuk 32 splitter DRAWN CHECKED CHECKED
Distribusi :
24 core untuk 24 splitter
cascade 2
cascade 2 = 256 port
Feeder level 3 : Sisa :
48 core dengan 3 core masukan 24 core tarikan 3 : 8 core untuk 8 splitter cascade
2 = 64 port Jaka Sudana Andri F.
Feeder level 1 / Backbone : PROJECT
264 core dengan 168 core masukan
Total port = 192 + 256 + 64 = 512 port
ODC24 / ODC24.XXX00.02 ODC24.XXX00.02 XXX00.01.04.01 XXX00.01.07.08
FTTH NETWORK
tarikan 1 dan tarikan 3 dapat
mini A B
dimaksimalkan dengan penambahan DRAWING TITLE
Distribusi :
32 core untuk 32 splitter
cascade 2
input core dan ODC24.
Feeder level 2 :
48 / 96 /144 / 264 core dengan 8 core masukan
untuk 8 splitter cascade 1 dan 4 core spare
Feeder level 3 :
48 core dengan 4 core masukan
Sisa :
16 core
total hasil pemaksimalan adalah 256 port ODC24 SPESIFICATION
Enclousure Enclousure x 3 = 768 port
DRAWING NAME
pemaksimalan dengan enclosure 48 core
ODC72 - ODC24 mini
4-outport = 256 x 4 = 1024 port DISTRIBUTION SCHEME
pemaksimalan dengan enclosure 96 core COMPARE
ODC24.XXX00.03 XXX00.01.08.01 XXX00.01.08.08
6-outport = 256 x 6 = 1536 port SITE ID LOCATION

Distribusi :
8 core untuk 8 splitter Jadi : ID INDONESIA AREA
cascade 2
Feeder level 3 :
48 core dengan 1 core masukan
Sisa :
40 core
ODC 24 single / double : SCALE REVISED
Input max. (on) = 3 core / 6 core No.
1.
DATE
-
SIGNATURE

Output max. (on) = 24 core / 32 core NTS

Port max. (on) = 192 port / 256 core NO. REGISTER Sheet No.: 2
of : 2
FTTH 001
A3
TECHNICAL SPESIFICATION

SKEMA PENGGUNAAN ODC24


Untuk :
NOTES/ REMARKS

3 tarikan kabel 48core, 88 splitter, 704 pelanggan

ODC24.XXX00.01

Feeder level 3 : Distribusi :


48 core dengan 3 core masukan 24 core untuk 24 splitter
cascade 2
Sisa :
24 core
Feeder level 1 / Backbone :
264 core dengan 168 core masukan
Approved By :
PT. MNC KABEL MEDIACOM

ODC24.XXX00.02 ODC24.XXX00.02

A B RAFDIAN RASYID

Feeder level 2 : WAWAN JULIAWAN


48 / 96 /144 / 264 core Feeder level 3 : Distribusi : DRAWN CHECKED CHECKED
dengan 15 core masukan 48 core dengan 6 core masukan 32 core untuk 32 splitter
Enclousure Enclousure cascade 2
Sisa :
Jaka Sudana Andri F.
0 core
PROJECT

FTTH NETWORK

DRAWING TITLE

ODC24.XXX00.03 ODC24.XXX00.03
ODC24 SPESIFICATION
A B DRAWING NAME

ODC24 DISTRIBUTION SCHEME


WITH THREE LINE CABLE
DISTRIBUTION
SITE ID LOCATION

Feeder level 3 : Distribusi : ID INDONESIA AREA


48 core dengan 6 core masukan 32 core untuk 32 splitter
SCALE REVISED
cascade 2 No. DATE SIGNATURE
Sisa : NTS
1. -

0 core
NO. REGISTER Sheet No.: 2
of : 2
FTTH 001
A3
TECHNICAL SPESIFICATION

. 40 - 45 meter 40 - 45 meter
. 40 - 45 meter
. . 40 - 45 meter
264 Core
F.OFROM 48 Core F.O. 48 Core F.O. 48 Core F.O. 48 Core F.O. NOTES/ REMARKS
FEEDER DISTRIBUSION DISTRIBUSION DISTRIBUSION DISTRIBUSION
Fixed Clamp
30

30

30
48 Core F.O. 48 Core F.O. 48 Core F.O.
SUSPENSION
INCLUDE BRACKET
85

85

85
850
85

85
ODC24.XXX00.01 Slack Support Slack Support XXX00.01.01.01 Slack Support
CL48.XXX00.00

ODC24 CLOSURE 48c ODP

Slack Cabel Slack Cabel Slack Kabel


15 m Kiri-Kanan 15 m Kiri-Kanan 15 m Kiri-Kanan
85

XXX00.00

500

500
300

385
Approved By :
PT. MNC KABEL MEDIACOM

DEDY ABIDIN

JAKA WIRAKANDI
DRAWN CHECKED CHECKED

ARIESTA - -
30

30

30

30
PROJECT

FTTH NETWORK
100

100

100

100
DRAWING TITLE

SPESIFIKASI
TIANG 6
DRAWING NAME
SPESIFIKASI
PENARIKAN DAN
SPESIFIKASI TIANG 6 PENANAMAN TIANG 6

SCALE :
N.T.S

1
1
TECHNICAL SPESIFICATION

ODC24.XXX00.00 NOTES/ REMARKS


XXX00.01.01.01

ODP_HUAWEI_TIANG
ODC_ZTE_TIANG
ODC24.XXX00.01 XXX00.01.01.01

CL48.XXX00.00
XXX00.01.01.01

CLOSURE_HUAWEI_TIANG

ODP_ZTE_TIANG

Approved By :
PT. MNC KABEL MEDIACOM

5
DEDY ABIDIN
16

ODC24.XXX00.00
2.5

JAKA WIRAKANDI
DRAWN CHECKED CHECKED
LABEL ODC/ODP/CLOSURE
ODC24_PEDESTAL ODP_PEDESTAL
ARIESTA - -

PROJECT
-PELABELAN PADA ODC/ODP/CLOSURE TIPE TIANG MAUPUN PEDESTAL DILAKUKAN BERDASARKAN NO HASIL AS BUILT DRAWING
FTTH NETWORK
-LABEL DI TULISKAN PADA BAGIAN TENGAH PERMUKAAN DAN DI ATAS DIBERI LOGO PLAY
-PELABELAN ID DILAKUKAN DRAWING TITLE

DENGAN CAT SEMPROT ATAU MENGGUNAKAN SPON SPESIFIKASI


TIANG 6
DRAWING NAME
-UNTUK LOGO DAPAT BERUPA STIKER CUTTING POSISI,UKURAN DAN
LABEL ODC
/ODP/CLOSURE
-UKURAN ID LABEL :
TINGGI 2,5 CM
TYPE HURUF : ARIAL BLACK
WARNA:HITAM UNTUK ZTE DAN PUTIH UNTUK HUAWEI

-UKURAN LOGO PLAYMEDIA:


TINGGI : 5 CM 1
1

PANJANG 16 CM
. TECHNICAL SPESIFICATION
264 Core
F.OFROM
FEEDER

30
NOTES/ REMARKS
48 Core F.O.

85

85
ODC24.XXX00.01 Slack Support

XXX00.00
ODC24

XXX00.00

XXX00.00
Slack Cabel
15 m Kiri-Kanan

URUTAN NOMOR XXX00.00

85
TIANG 6

XXX00.00
KODE AREA
TIANG 6

Approved By :
PT. MNC KABEL MEDIACOM

DEDY ABIDIN

JAKA WIRAKANDI
DRAWN CHECKED CHECKED

5 cm 5 cm 5 cm 5 cm

ARIESTA - -

PROJECT
LABEL TIANG DISTRIBUSI
TINGGI : 5cm FTTH NETWORK
TIPE HURUF : ARIAL BLACK DRAWING TITLE

WARNA : PUTIH SPESIFIKASI


TIANG 6

300
PELABELAN DRAWING NAME

POSISI,UKURAN DAN
DENGAN CAT PUTIH LABELPADA TIANG 6

SEMPROT ATAU
MENGGUNAKAN SPON

1
1
. 40 - 45 m
TECHNICAL SPESIFICATION

264 Core
F.OFROM
FEEDER NOTES/ REMARKS

30
48 Core F.O.
85

Approved By :
PT. MNC KABEL MEDIACOM

85
ODC24.XXX00.01 Slack Support
DEDY ABIDIN

ODC24 JAKA WIRAKANDI


DRAWN CHECKED CHECKED

Slack Cabel ARIESTA - -

PROJECT
15 m Kiri-Kanan
FTTH NETWORK
85

DRAWING TITLE

SPESIFIKASI
TIANG 6
DRAWING NAME
POSISI,UKURAN DAN
LABEL ODC PADA
TIANG 6
XXX00.00

1
1
TECHNICAL SPESIFICATION

. 40 - 45 meter NOTES/ REMARKS

48 Core F.O.
DISTRIBUSION
Fixed Clamp

30
85 Approved By :
PT. MNC KABEL MEDIACOM

85
XXX00.01.01.01 Slack Support DEDY ABIDIN

ODP DRAWN
JAKA WIRAKANDI
CHECKED CHECKED

Slack Kabel ARIESTA - -

PROJECT
15 m Kiri-Kanan
FTTH NETWORK

DRAWING TITLE

SPESIFIKASI
TIANG 6
DRAWING NAME
POSISI ,UKURAN DAN
LABEL ODP PADA
TIANG 6

1
1
TECHNICAL SPESIFICATION

NOTES/ REMARKS

264/144/96 Core F.O.

LABEL CLOSURE
Approved By :
PT. MNC KABEL MEDIACOM

Slack Support
CL48.XXX00.00
DEDY ABIDIN

CLOSURE 264/144/96 Core


JAKA WIRAKANDI
F.O. DRAWN CHECKED CHECKED

Slack Cabel
15 m Kiri-Kanan
ARIESTA - -

PROJECT

FTTH NETWORK

DRAWING TITLE

SPESIFIKASI
TIANG 6
DRAWING NAME
POSISI,UKURAN DAN
LABEL CLOSURE PADA
TIANG 6

1
1
TECHNICAL SPESIFICATION

NOTES/ REMARKS

SUSPENSION
INCLUDE BRACKET Approved By :
PT. MNC KABEL MEDIACOM

DEDY ABIDIN

JAKA WIRAKANDI
DRAWN CHECKED CHECKED

ARIESTA - -

PROJECT

FTTH NETWORK

DRAWING TITLE

SPESIFIKASI
TIANG 6
DRAWING NAME
POSISI,UKURAN DAN
LABEL CLOSURE PADA
TIANG 6

1
1
TECHNICAL SPESIFICATION

NOTES/ REMARKS

30
permukaan tanah

6000
20
Angkur

20
Angkur Approved By :
PT. MNC KABEL MEDIACOM

DEDY ABIDIN

20
JAKA WIRAKANDI

Angkur DRAWN CHECKED CHECKED

ARIESTA - -

PROJECT

FTTH NETWORK

20
DRAWING TITLE

kuncian SPESIFIKASI
TIANG 6
angkur DRAWING NAME
KONSTRUKSI
TIANG 6
CONCRETE K 225

46,98
20
50
1

200 1