Anda di halaman 1dari 3

PT KAWANO PILAR MANDIRI DIBUAT

Dh DISETUJUI

PARAMETER INPUT QC TESTER


INPUT PowerAC Input AC awith Stand Input Grounding

TABEL PENGUJIAN

NO MEMORY PRODUK JENIS PENGUJIAN

1 TEAM 01 SLOW JUICER ESJ 999 A. PENGUJIAN AC POWER 220V

150 WATT STD : 220 V/20 WATT NO LOAD 30 DETIK

B. PENGUJIAN AC WITH STAND (KUAT)

INPUT 1500 V/2 DETIK


PT KAWANO PILAR MANDIRI DIBUAT
Dh DISETUJUI

2 TEAM 02 RICE COOKER LOW A. PENGUJIAN AC POWER 220V/500 WATT


CARBO
220 V/ 470 WATT 30 DETIK NO LOAD
500 WATT
B. PENGUJIAN AC WITH STAND (KUAT)

INPUT 1500 V/2 DETIK

C UJI GROUNDING

INPUT CURENT 25 A

0,2 OHM

3 TEAM O3 HAND BLENDER A. PENGUJIAN AC POWER 220V /50- 400 WATT

50-400 WATT 220 V/30 WATT 30 DETIK NO LOAD

B. PENGUJIAN AC WITH STAND (KUAT)

INPUT 1500 V/2 DETIK

4 TEAM 04 FOOD PROCESOR A. PENGUJIAN AC POWER 220V /300 WATT

300 WATT STD 220 V/ 120 WATT 30 DETIK NO LOAD

B. PENGUJIAN AC WITH STAND (KUAT)

INPUT 1500 V/2 DETIK


PT KAWANO PILAR MANDIRI DIBUAT
Dh DISETUJUI

5 TEAM 05 STAND MIXER A. PENGUJIAN AC POWER 220V /500-1100 WATT

500-1100 WATT STD :220 V/ 28 WATT 30 DETIK NO LOAD

B. PENGUJIAN AC WITH STAND (KUAT)

INPUT 1500 V/2 DETIK

6 TEAM 06 SLOW JUICER BM A. PENGUJIAN AC POWER 220V/ 240 WATT

240 WATT STD 220 V/ 50 WATT 30 DETIK NO LOAD

B. PENGUJIAN AC WITH STAND (KUAT)

INPUT 1500 V/2 DETIK

Note : Jika pengujian berhasil maka di QC tester akan menampilkan ”PASS” dan lampu hijau menyala

Jika pengujian gagal maka di QC tester akan menampilkan “FAIL” dan lampu merah menyala (periksa rankaian
pengujian dan dan rangkaian wiring produk)