PENGUKURAN
MEASUREMENT
EQUIPMENT STANDARD UNIT MINGGU 1 MINGGU 2 MINGGU 3 MINGGU 4 STATUS
POINT
Winding Celcius
Fasa R Outgoing Celcius
Fasa S Outgoing Celcius
CIRCULATING WATER Fasa T Outgoing Celcius
EPRI Critical
PUMP B #1 Bearing M1 Celcius 85 52,9
Bearing M2 Celcius 88 82,5
Bearing P1 Celcius 63 48,9
Bearing P2 Celcius 60 32,3
ANALYSIS
- Temperatur tinggi pada bearing motor CWP B dengan nilai di atas 82 C.
- Indikasi kurang pelumasan
- Indikasi putaran berat
- Indkasi permasalahan bearing motor
REKOMENDASI
Jangka pendek:
- Lakukan penambahan pelumas (grease) di motor
- Cek arus ampere motor.
- Cek thermography outgoing breaker fase R, S, T di breaker panel motor
- Cek putaran rpm shaft
- Monitoring terhadap kenaikan temperature bearing motor
Jangka panjang:
- Lakukan pengecekan bearing motor saat shutdown. Ganti bearing jika sudah mengalami kerusakan.