Elektronik Detonator
Elektronik Detonator
DETONATOR
Elektronik Detonator
• UnitronikTM System
i-kon Digital
TM
Energy System
i-kon TM
Digital Energy System
• Hardware
- Detonator
- Logger
- Blaster
• Software
- Shotplus-i
i-kon TM
Detonator
• Waktu delay detonator : 0 -
15000 ms dengan beda 1ms
• Akurasi : +/- 0.1% dari waktu
delay terprogram
• Detonator ID khusus
• Komunikasi dua arah
• Tidak terjadi overlap waktu
delay
• Detonator kekuatan tinggi
• Aman terhadap over voltage,
arus liar dan arus statis
• Memiliki konektor
i-kon TM
Detonator
• Sisi Power
Spark Gap
Capacitor
Safety Fuse Head
Bleed
Resistors Resistor
i-kon TM
Detonator
• Sisi Kendali
Electronic Chip
Lead
Wires Fuse head
i-kon TM
Detonator ID
• Detonator ID
• Tanggal produksi
i-kon TM
Logger
• Sistem Pengaman
– < no-fire voltage
– no firing code
• Logging
– Verifikasi status detonator
– Membaca dan menyimpan
Detonator ID dalam
memory
– Menentukan waktu delay
• Testing
– Verikasi koneksi detonator
dan harness wire
– Memberikan laporan error,
kebocoran arus
• Kapasitas : 200 detonator
i-kon TM
Blaster
i-konTM Blaster 400 • Kunci Pengaman
• Komunikasi 2 arah
• Fungsi :
– Kalibrasi
– Pemrograman
– Laporan error
– Firing
• Kapasitas : 2 Logger (400
detonator)
i-kon TM
Blaster
i-konTM Blaster 1600 • Kunci Pengaman
• Komunikasi 2 arah
• Fungsi :
– Kalibrasi
– Pemrograman
– Laporan error
– Firing
• Kapasitas : 8 Logger
(1600 detonator)
Software Shotplus-i
• Desain peledakan untuk
logging / pemrograman waktu
delay
.
196 198 200 202 204
High numbers
42 59 76 93 110 127
0 17 34 51 68 85
-1% 413 430 447 464
481 417
Nom In-Hole 434 451 468 485
+1% 421 438 455 472 489
17ms => 9 - 25ms !
Sistem Safety
i-kon Detonator
TM
Logging i-kon TM
Detonator
1
2
. .
...
198
199
200
LOGGER
Logging det#
Logging
Logging det#
det#200
det# 21
198
199
BATT
+/-
Logging i-kon TM
Detonator
LOGGER
No. ID-number delay time
DET#
DET# 200
2
31 INC:
INC: 25
INC: 25
1 F00B24 0 ms 4975
25
0
0 ms
ms
ms
ms
5000
50
25
0
2 D23A66 25 ms
3 C01E44 50 ms
....
....
....
BATT
+/-
BLASTER
READY TO FIRE
>Testing...
>PRESS BOTH FIRE BUTTONS
>Calibrating
TO START BLAST SEQUENCE
>Programming...
>REMOVE KEY TO SHUT
DOWN BLASTER
FIRE
FIRE
KEY
Blaster Connection and Firing
i-kon TM
Digital Energy System
• Fragmentasi • Pengaturan Waktu
• Wall Delay
Control/Presplitting • Expand Pattern
• Backbreak • Produksi
• Lingkungan (Vibrasi) • Biaya
• Pemisahan
Ore/Waste
• Throw/Lemparan
Fragmentasi
Fragmentasi
Size Distribution for i-kon Pattern Expansion trials
100%
90%
60%
i-kon #1: Better Fragmentation
50%
40%
10%
0%
0.000 0.100 0.200 0.300 0.400 0.500 0.600
Size (m)
Wall Control /
Presplitting
Presplitting Nonel Detonator
Presplitting I-kon TM
Detonator
Back Break
Desain Shotplus-i
Post Blast i-kon TM
Post Blast Nonel Detonator
Pemisahan
Ore/Waste
Pre Blast i-kon TM
Desain Shotplus-i
Post Blast i-kon TM
Pre Blast i-kon TM
Desain Shotplus-i
High grade
Low grade
High grade
Post Blast i-kon TM
Throw /
Lemparan
Std. timing
New timing:
C.o.M. 60 % further
Standard System
Introduction Video
Unitronik TM
System
Unitronik TM
System
• Detonator
• Scanner
• Network Tester
• Blast Box
Unitronik TM
Detonator
• Waktu delay detonator : 0
- 10000 ms dengan beda
1ms
• Akurasi : +/- 0.1% dari
waktu delay terprogram
• Detonator ID khusus
• Aman terhadap over
voltage, arus liar dan arus
statis
Unitronik TM
Scanner
• Pasif Scanning
• Kapasitas 400
detonator
Unitronik NetworkTM
Tester
• Test koneksi detonator
• Test status deonator
• Test kebocoran arus
Unitronik TM
Blast Box
• Kunci Pengaman
• Komunikasi 2 arah
• Pemrograman
detonator
• Kapasitas 400
detonator