Anda di halaman 1dari 12

STUDIO PERANCANGAN 1

PERHITUNGAN GORDING

1. DIMENSI PROFIL
 Jarak antar kuda kuda =4m
 Kemiringan atap = α = 20o
 Jarak antar gording = 1,52 m (Diagonal)
 Mutu Baja = BJ 37 (fu = 370 Mpa; fy = 240 Mpa)
 Profil Gording = CNP 12
 `Dengan data profil :
o Ag = 1700 mm2
o Ix = 3640000 mm4
o Iy = 432000 mm4
o rx = 46,2 mm
o ry = 15,9 mm
o Sx = 60700 mm3
o Sy = 1110 mm3
o Zx = 73152 mm3
o Zy = 14862 mm3
o h = 120 mm
o bf = 55 mm
o tw = 7 mm
o tf = 9 mm
o r1 = 4,5 mm
o fr = 70 MPa
o G = 80000 MPa
o Ec = 2100000 MPa
o Es = 2000000 MPa
STUDIO PERANCANGAN 1

2. PEMBEBANAN

a) Beban Mati
Perletakan gording-gording 20° di asumsikan sendi-sendi
 Berat sendiri gording = 13,4 kg/m
 Berat Penutup Atap (PPIUG hal-12) = 50 kg/m2 x 1,52 m = 76 kg/m
 Berat sambungan 10% x (10,6+76) kg/m = 8,94 kg/m
q total = 98,34 kg/m

b) Beban Hidup
Beban hidup di tengah-tengah gording P = 100 kg (PPIUG 1983 pasal 3.2.1)

c) Beban Angin
Untuk struktur bangunan berupa gedung tertutup dimana atap berbentuk segitiga
dengan sudut kemiringan α (PPIUG 1983 pasal 4.3.1b) tekanan angin P = 25
kg/m2.
 Atap segitiga dengan sudut kemiringan 20° (α < 65°)
Koefisien angin tekan (Ct) = 0,02 α – 0,4
= 0,02 (20) – 0,4
= -0,3930

Koefisien angin hisap (Ch) = -0,4


ω tekan = Ct x jarak gording x P
= -0,393 x 1,52 x 25
= -14,935 kg/m
ω hisap = Ch x jarak gording x P
= -0,4 x 1,52 x 25
= -15,2 kg/m

d) Beban Air Hujan


Beban terbagi rata per m2 bidang datar berasal dari beban air hujan sebesar (40 -
0,8α) kg/m2 (PPIUG 1983 pasal 3.2.2.a)
STUDIO PERANCANGAN 1

Wh = 40 - 0,8α
= 40 – (0,8x20)
= 24 kg/m2 ¿ 20 kg /m2
Maka diambil Wh 24 kg/m2

qh = Wh x jarak gording
= 24 x 1,52
= 36,48 kg/m

3. MOMEN PADA GORDING

qx

qy
q
a

qy
qy

dy

Ly

Mx

qx
qx

dx

Lx

My
STUDIO PERANCANGAN 1

MOMEN PADA GORDING


Pada arah sumbu lemah dipasang trekstang pada tengah bentang sehingga :
Bentang panjang (Lx) =4m
Bentang pendek (Ly) = ½ Lx
=½.4=2m
a) Beban mati
q = 98,34 kg/m
qy = 98,34 cos 20 qx = 98,34 sin 20
= 92,409 kg/m = 33,634 kg/m

1 1
Mx = qy Lx 2 My = qx Ly 2
8 8
1 1
= (92,409)¿ = (33,634)¿
8 8
= 93,969 kgm = 17,101 kgm

b) Beban hidup
P = 100 kg
Py = 100 cos 20 Px = 100 sin 20
= 93,969 kg = 34,202 kg
1 1
Mx = Py Lx My = Px Ly
4 4
1 1
= (93,969)(4) = (34,202)(2)
4 4
= 93,369 kgm = 17,101 kgm

c) Beban Angin
1 1
My = (ω tekan) Ly 2 Mx = (ω hisap) Lx 2
8 8
1 1
= (−14,934)¿ = (−15,2)¿
8 8
= -7,6 kgm = -29,869 kgm
STUDIO PERANCANGAN 1

d) Beban Air Hujan


qh = 36,48 kg/m2
1 1
Mx = ( qh ) cos α ¿ My = ( qh ) sin α ¿
8 8
1 1
= ( 36,48 ) cos 20 ¿ = 36,48 sin 20 ¿
8 8
= 3,493 kgm = 4,491 kgm

KOMBINASI PEMBEBANAN
Kombinasi pembebanan menurut SNI 03-1729-2002 sebagai berikut:
1. 1,4D
2. 1,2D + 1,6L +0,5(La atau H)
3. 1,2D + 1,6(La atau H) + 0,5W
4. 1,2D + W + L + 0,5 La
5. 1,2D + E + L + 0,2 S
6. 0,9D + W
7. 0,9D + E

Keterangan :
D = Beban mati
L = Beban hidup yang timbul akibat pengguna gedung
La = Beban hidup yang timbul selama perawatan oleh pekerja
H = Beban Hujan
W = Beban Angin
E = Beban Gempa
Dengan γL = 0,5 bila L< 5 kPa, dan γL = 1 bila L ≥ 5 kPa.
Beban angin hisap tidak diperhitungkan karena akan memperingan struktur dan selain itu
angin tidak selalu berembus.

Sumbu x Sumbu y
No Kombinasi Pembebanan
(kgm) (kgm)
STUDIO PERANCANGAN 1

1. 1,4D 258,7462 23,5439


2 1,2D + 1,6L +0,5(La atau H) 268,7671 28,7311
3 U = 1,2D + 1,6(La atau H) + (γL.L atau 0,8W) 348,2378 41,4621
4 U = 1,2D + 1,3W + γL.L + 0,5(La atau H) 229,9369 18,8511
5 U = 1,2D + 1,0E + γL.L 127,5066 5,2554
6 0,9D + (1,3W atau 1,0E) 205,1671 25,0154

Kombinasi pembebanan maksimum arah sumbu x adalah kombinasi ke-3


Kombinasi pembebanan maksimum arah sumbu y adalah kombinasi ke-3
4. KONTROL PENAMPANG
Cek kekompakkan penampang :

Flens Web
b 55 h 120
λ= 2.tf = 18 = 3,0556 λ= tw = 7 = 17,143
170 170 1680 1680
λp= √ fy = √240 = 10,973 λp= √ fy = √240 = 108,4435
370 370 2550 2550
λr= √ fy−fr = √240−70 = 28,3777 λr= √ fy−fr = √240−70 = 195,576
Karena flens λ< λp maka flens kompak.
Karena web λ < λp maka web kompak.
Jadi, disimpulkan bahwa penampang kompak, maka Mn = Mp

5. KONTROL MOMEN
 Kontrol Momen Terhadap Leleh
Mux = 248,2377 kgm Muy = 41,4622 kgm
Mpx = Zx . fy Mpy = Zy . fy
= 73152 . 240 = 14862 . 240
= 1755,648 kgm = 356,688 kgm
Mnx = Mpx Mny = Mpy
= 1755,648 kgm = 256,688 kgm
Mux Muy
Mnx(=1755,648 > (= 386,931) .. OK Mny(=256,688 > (= 46,069) .. OK
Ø Ø

 Terhadap Tekuk Torsi Lateral


I y × ( h -tf )2 432 000 × ( 1 20 - 9 )2
Cw = = = 1330668000 mm6
4 4
STUDIO PERANCANGAN 1

1
J =∑ × bt3
3
1
= × (2 ×bf × tf3) + (ht-(2×tf) × tw3
3
1
= × (2 × 55 × 93) + (120-(2×9) × 73
3
=
61716 cm4

π EGJA π 200000 × 80000× 61716 ×1700


X1 =
Sx √ 2
=
60700 √ 2
=47392,465 Mpa

Cw Sx 2 2
1330668000 60700
X2 =4
Iy GJ
=4( ) (
432 000 )( 80000 ×61716 )
= 1 ,86229× 10-6 Mpa

Lb =4m
= 4000 mm
790× r y
Lp =
√f y
790× 15,9
=
√ 240
= 810,809 mm
ry × X 1
Lr = 1+ √ 1+ X 2(fy −fr )2

fy −fr
15,9× 47392,465
= 1+ √ 1+1,86229× 10−6 (240−70)2

240−70
= 82273,775 mm

Dikarenakan Lp < Lb< Lr (Bentang menengah) atau


810,809 mm < 4000 mm < 82273,775 mm, maka:

Untuk sumbu x :
Mrx = Sx( Fy−Fr) Mpx = Zx× Fy
= 60700 (240−70) = 73152 x 240
STUDIO PERANCANGAN 1

= 10319000 Nmm = 17556480 Nmm


= 1031,9 kgm = 1755,648 kgm

Diketahui : Mmaks = 348,237 kgm


l =4m

8 × Mmaks 8 ×277,746
q= = =174,1189 kgm
l2 42
ql 181,3851 × 4
Va = = =348,2378 kgm
2 2
l 1 l 2
1/4 bentang (MA)
4 2 4( )
= Va × l− q × l =¿261,178 kgm

2
l 1 l
1/2 bentang (MB) = Va × l− q × ( l ) =348,238 kgm
2 2 2
2
3 1 3
3/4 bentang (MC) = Va × l− q × ( l ) =261,178 kgm
4 2 4
12,5 Mmaks
Cb =
2,5 Mmaks +3 MA+ 4 MB+ 3 MC
12,5(474,182)
= = 1,136
2,5(348,237)+3(261,178)+4 (348,238)+ 3(261,178)
Lr−Lb
Mnx [
= Cb Mr+(Mp−Mr)(
Lr−Lp
) ]
= 1,136 ¿
= 1916,950 kgm

Mpx (=1755,648) > Mnx (=1916,950) kgm (diambil yang lebih kecil yaitu Mnx)

ϕbMnx = 0,9 × Mnx


= 0,9 ×1916,950
= 1725,255 kgm

Untuk sumbu y :
Mry = Sy( Fy−Fr) Mpy = Zy× Fy
= 1110 (240−70) = 14862 × 240
= 188700 Nmm = 3566880 Nmm
STUDIO PERANCANGAN 1

= 18,87 kgm = 356,688 kgm

Diketahui : Mmaks = 41,462 kgm


l =2m
8 × Mmaks 8 × 41,462
q= = =82,924 kgm
l2 22
ql 82,924 ×2
Va = = =82,924 kgm
2 2
l 1 l 2
1/4 bentang (MA)
4 2 ( )
= Va × l− q × l =¿31,0966 kgm
4

l 1 l 2
1/2 bentang (MB)
2 2 ( )
= Va × l− q × l =¿41,462 kgm
2

2
3 1 3
3/4 bentang (MC)
4 2 ( )
= Va × l− q × l =¿31,0966kgm
4

12 Mmaks
Cb =
2,5 Mmaks +3 MA+ 4 MB+ 3 MC
12(104,582)
= = 0,4032
2,5(41,462)+3(31,0966)+4 ( 41,462)+3(31,0966)
Lr−Lb
Mny [
= Cb Mr+(Mp−Mr)(
Lr−Lp
) ]
82273,775−4
[
= 1,136364 1031,9+(1755,648−1031,9)(
82273,775−810,809
) ]
= 3,895 kNm
Mpy (=356,688) > Mny (=389,459) kgm (diambil yang lebih kecil yaitu Mny)

ϕbMny = 0,9 × Mny


= 0,9 × 389,459
= 350,513 kgm

Momen nominal penampang momen ultimate


ϕbMnx = 1725,255 kgm > Mux = 348,2378 kgm .. OK

ϕbMny = 350,5132 kgm > Muy = 41,46217 kgm .. OK


STUDIO PERANCANGAN 1

Profil CNP 12 aman terhadap tekuk lateral

KONTROL PUNTIR
Untuk mengantisipasi masalah puntir maka Mny dapat dibagi 2

Mux Muy
+
φb . Mnx 1 ≤ 1,0
φb. Mny
2
348,2377 41,4622
+
1725,255 1 ≤ 1,0
.175,256
2
0,4384 ≤ 1,0  OK !!!
Jadi profil CNP 12 aman terhada ppengaruh puntir

KONTROL GESER(SNI 03-1729-2002 Pasal 8.8.1)


Vu/2 ≤ φ Vn
Ketentuan kuat geser nominal :

h 1100 1100
=17,143 = =71,005
tw √ fy √ 240

h 1100
Karena < , maka :
tw √ fy

Vn = 0,6 × fy × h × tw ϕ
= 0,6 × 240 × 120 × 7 .

= 120960 N V
n

Kontrol:
348,237 x 8 4
Vux ≤ ϕ.Vn → 2 × ≤ 9072 kg → 348,2378 kg ≤ 9072 kg (OK!)
4 2
41,462 × 8 4
Vuy ≤ ϕ.Vn → 2 × ≤ 9072 kg → 41,4622 kg ≤ 9072 kg (OK!)
4 2
STUDIO PERANCANGAN 1

Jadi Profil CNP 12 aman terhadap pengaruh geser

KONTROL LENDUTAN
Lendutan maksimum yang diijinkan :
Lx = 400 cm
Ly = 200 cm
L
δ ijin =
240
Ly
δy ijin =
240
200
=
240
= 0,8333 cm
Lx
δx ijin =
240
400
=
240
= 1,6667 cm

Lendutan arah sumbu y


Beban terpusat = 100 Sin 20
= 34,202 kg
Beban merata = (beban mati + beban hujan + beban angin) Sin α
= (32,5808+ 18,24 + 0) Sin 20o
= 17,742 kg/m = 0,17742 kg/cm

5 qtotal . Ly 1 P Ly 3
( )( )
4

δy = +
384 E . Ix 48 E . Ix
4 3
5 0,17742. 200 1 34,202. 200
=(
384 ) ( 2 x 10 . 3646)+
48 2 x 10 . 364 6

= 0,0146 < 0,8333 cm OK

Lendutan arah sumbu x


STUDIO PERANCANGAN 1

Beban terpusat = 100 Cos 20o


= 93,969 kg
Beban merata = (beban mati + beban hujan + beban angin) Cos α
= (89,515+ 36,48 + 0) Cos 20o

= 93,048 kg/m = 0,93048kg/cm

5 qtotal . Lx 1 P Lx3
( )( )
4

δx = +
384 E . Iy 48 E . Iy
4 3
5 0,93048 400 1 93,969. 400
=( ) ( 6 ) +
384 2 x 10 . 43,2 48 2 x 10 . 43,2 6

= 0,1922 < 1,6667 cm OK

Jadi profil CNP 12 aman terhadap lendutan.

Anda mungkin juga menyukai