Ancol Flood Pumping Station Rehabilitation

(Rehabilitasi Rumah Pompa Banjir Ancol)

Jo
Doc. No. : 0 INVENTORY SHEET/SHEETS : 1 10

1.0 Mechanical Layout

11

13
10

7 8 9

12

3 3 3
5m /Sec 5m /Sec 3.5m /Sec

5 6
4
3

2 1 Trashrake - Bar Screen

2 Intake Stoplog

1 3 Trashrake - Automatic (MEH)

4 Horizontal Konveyor

5 Inclined Konveyor

6 Bak Sampah

7 Axial Vertical Pump / Pump-1

8 Axial Vertical Pump / Pump-2

9 Axial Submersiblel Pump / Pump-3

10 Flushing Gate

11 Flushing Stoplog

12 Flood Gate

13 Flood Stoplog

Jo
Doc. No. : 0 DATA EXISTING SHEET/SHEETS : 1 10

1.1 Area Fasilitas Intake

No. Location Name Inventory Keterangan Qty Tipe Kondisi

Intake Trashrake - 1

- Frame - - - -

- Screen 4925 x 7000 3-Set Bar Screen Korosi

- Pengangkat Sampah - - Manual -

Intake Stoplogs

- Guide Frame 3-Set Konstruksi Baja Korosi

- Daun Stoplog 7-Set Konstruksi Baja Rusak dan Korosi

- Dogging Device 6-Set Engsel Hook Rusak dan Korosi

Intake Trashrake - 2 MEH Automatic Masih Bagus

- Frame - 3-Set Konstruksi Baja Masih Bagus

- Screen 4925 x 7000 3-Set Bar Screen Masih Bagus

- Pengangkat Sampah - 1-Set Manual Kurang 2 Set

- Conveyor - 1-Set Horizontal Kurang Tinggi

- Conveyor - 1-Set Vertical Kurang Tinggi


1 Intake Area

Over Head Crane Rusak/Korosi

- Hoist - 1-Set Std Head room Rusak

- Crane Structure - 1-Set Single Girder Rusak

- Electrical - 1-Set - Rusak

- Structue Bangunan - 1-Lot Atap Terbuka Perlu ada atap

Perangkat Lain

3
- Bak Sampah 5m 1-Set welded Steel Rusak

- Rumah Panel - 1-Unit - Box Panel Rusak

- Pile Scale - 1-Set - Masih Bagus

Semua perlatan pada area Intake lengkap namun demikian dikarenakan usia pakai yang sudah cukup lama

semua peralatan tersebut sudah rusak karena korosi dan cuaca, Hanya automatic trash rake yang masih terlihat

beroperasi dengan baik namun demikian sudah tidak mampu untuk melayani ke tiga saluran intake pompa.

Jo
Doc. No. : 0 DATA EXISTING SHEET/SHEETS : 1 10

1.2 Area Rumah Pompa

No. Location Name Inventory Keterangan Qty Tipe Kondisi

Over Head Crane Masih Berfungsi

- Hoist Cap.16 Ton 1-Set Crab type Masih Berfungsi

- Crane Structure - 1-Set Double Girder Masih Bagus

- Electrical - 1-Set - Masih Bagus

- Structue Bangunan - 1-Lot Atap Tertutup Masih Bagus

Pompa - A Tidak Berfungsi

3
- Pump Unit Cap. 5m /det 1-Set Axial Verical Tidak Berfungsi

- Gearbox - 1-Set Planetary gearbox Tidak Berfungsi

- Motor - 1-Set Vertical Mounted Tidak Berfungsi

- Panel - 1-Lot - Tidak Berfungsi

- Komponent - 1-Lot - Tidak Berfungsi

- Instrument - 1-Lot - Tidak Berfungsi

Pompa - B Tidak Berfungsi

- Pump Unit Cap. 5m3/det 1-Set Axial Verical Tidak Berfungsi


2 Rumah Pompa
- Gearbox - 1-Set Planetary gearbox Tidak Berfungsi

- Motor - 1-Set Vertical Mounted Tidak Berfungsi

- Panel - 1-Lot - Tidak Berfungsi

- Komponent - 1-Lot - Tidak Berfungsi

- Instrument - 1-Lot - Tidak Berfungsi

Pompa - C Tidak Berfungsi

3
- Pump Unit Cap. 3.5 m /det 1-Set Axial Submersible Tidak Berfungsi

- Gearbox - 1-Set Planetary gearbox Tidak Berfungsi

- Motor - 1-Set Vertical Mounted Tidak Berfungsi

- Panel - 1-Lot - Tidak Berfungsi

- Komponent - 1-Lot - Tidak Berfungsi

- Instrument - 1-Lot - Tidak Berfungsi

Saat ini pompa telah mengalami penurunan effisiensi sebesar 22% dari yang semula pada efisiensi 80%

dari kapasitas yang direncanakan sehingga efisiensi pompa sekarang menjadi 58% dari kapasitas setiap pompa

Dan pompa menjadi tidak berfungsi jika terhubung dengan pipa perpanjangan.

Jo
Doc. No. : 0 DATA EXISTING SHEET/SHEETS : 1 10

1.3 Discharge Pipe

No. Location Name Inventory Keterangan Qty Tipe Kondisi

Discharge Pipe - A Rusak

- Elbow Dia.1500 1-Set Welded Steel Rusak dan Korosi

- Straight Pipe (Ins.) Dia.1800 1-Set Welded Steel Rusak dan Korosi

- Butterfly Valve Dia.1800 1-Set Automatic Rusak

- Actuator - 1-Lot Electrical Tidak Berfungsi

- Straight Pipe (Outs.) Dia.1800 1-Set Welded Steel Rusak dan Korosi

- Flap Valve Dia.1800 1-Lot Welded Steel Korosi

Discharge Pipe - B Rusak

- Elbow Dia.1500 1-Set Welded Steel Rusak dan Korosi

- Straight Pipe (Ins.) Dia.1800 1-Set Welded Steel Rusak dan Korosi

- Butterfly Valve Dia.1800 1-Set Automatic Rusak

- Actuator - 1-Lot Electrical Tidak Berfungsi

- Straight Pipe (Outs.) Dia.1800 1-Set Welded Steel Rusak dan Korosi

- Flap Valve Dia.1800 1-Lot Welded Steel Korosi

3 Discharge Pipe
Discharge Pipe - C Rusak

- Elbow Dia.1500 1-Set Welded Steel Rusak dan Korosi

- Straight Pipe (Ins.) Dia.1500 1-Set Welded Steel Rusak dan Korosi

- Butterfly Valve Dia.1500 1-Set Manual Rusak

- Actuator - - - -

- Straight Pipe (Outs.) Dia.1500 1-Set Welded Steel Rusak dan Korosi

- Flap Valve Dia.1500 1-Lot Welded Steel Korosi

Semua discharge Pipe Masih difungsikan meskipun dalam keadaan yang sudah tidak ideal

Jo
Doc. No. : 0 DATA EXISTING SHEET/SHEETS : 1 10

1.4 Discharge Gate

No. Location Name Inventory Keterangan Qty Tipe Kondisi

Discharge Gate - A Rusak

- Guide Frame - 1-Set Fix.Frame Rusak dan Korosi

- Gate Leaf - 1-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 1-Set Rubber seal Rusak

- Hoists system - 1-Set Electrical Tidak Berfungsi

- Gearbox - 1-Set Welded Steel Rusak dan Korosi

- Motor - 1-Set Electro motor Tidak Berfungsi

Discharge Gate - B Rusak

- Guide Frame - 1-Set Fix.Frame Rusak dan Korosi

- Gate Leaf - 1-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 1-Set Rubber seal Rusak

- Hoists system - 1-Set Electrical Tidak Berfungsi

- Gearbox - 1-Set Welded Steel Rusak dan Korosi

- Motor - 1-Set Electro motor Tidak Berfungsi

4 Discharge Gate
Discharge Gate - C Rusak

- Guide Frame - 1-Set Fix.Frame Rusak dan Korosi

- Gate Leaf - 1-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 1-Set Rubber seal Rusak

- Hoists system - 1-Set Electrical Tidak Berfungsi

- Gearbox - 1-Set Welded Steel Rusak dan Korosi

- Motor - 1-Set Electro motor Tidak Berfungsi

Discharge Stoplog Rusak

- Guide Frame - 3-Set Fix.Frame Rusak dan Korosi

- Stoplog Leaf - 3-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 3-Set Rubber seal Rusak

- Hoists system Cap. 5.3 Ton 1-Set Monorail Rusak

Semua perlengkapan untuk pintu-pintu discharge penahan air balik (ROB dan Back water) Sudah Rusak

dan sangat riskan mengingat justru pada bagian inilah yang paling vital untuk kondisi saat ini selama proses

Pelaksanaan dirumah pompa sentiong Berlangsung.

Jo
Doc. No. : 0 DATA EXISTING SHEET/SHEETS : 1 10

1.5 Flood Gate

No. Location Name Inventory Keterangan Qty Tipe Kondisi

Flood Gate - A Rusak

- Guide Frame - 1-Set Fix.Frame Rusak dan Korosi

- Gate Leaf - 1-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 1-Set Rubber seal Rusak

- Hoists system - 1-Set Electrical Tidak Berfungsi

- Gearbox - 1-Set Welded Steel Rusak dan Korosi

- Motor - 1-Set Electro motor Tidak Berfungsi

Flood Gate - B Rusak

- Guide Frame - 1-Set Fix.Frame Rusak dan Korosi

- Gate Leaf - 1-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 1-Set Rubber seal Rusak

- Hoists system - 1-Set Electrical Tidak Berfungsi

- Gearbox - 1-Set Welded Steel Rusak dan Korosi

- Motor - 1-Set Electro motor Tidak Berfungsi

5 Flood Gate
Flood Stoplog Rusak

- Guide Frame - 3-Set Fix.Frame Rusak dan Korosi

- Stoplog Leaf - 3-Set Fix.Wheel Gate Rusak dan Korosi

- Seals - 3-Set Rubber seal Rusak

- Hoists system Cap. 5.3 Ton 1-Set Monorail Rusak

Semua perlengkapan untuk pintu-pintu Pengatur Banjir penahan air balik (ROB dan Back water) Sudah Rusak

dan sangat riskan mengingat justru pada bagian inilah yang paling vital untuk kondisi saat ini selama proses

Pelaksanaan dirumah pompa sentiong Berlangsung.

Jo
1.6 Dokumentasi Kondisi Ekisting Stoplog Intake

Pengukuran Dimensi Stoplog Badan Stoplog Intake Yang Rusak dan korosi

Seal dan Klem Stoplog yang Rusak Posisi Stoplog Saat Tidak Digunakan

Kerusakan Stoplog Karena Tidak terlindung Dari Cuaca Posisi Stoplog Saat Tidak Digunakan

Catatan :

Semua Daun Stoplog Sudah Dalam katagori Rusak Parah Meskipun terKadang Masih digunakan jika ada perbaikan

Kerusakan stoplog dikarenakan penempatan nya saat tidak digunakan berada ditempat terbuka yang tidak terlindung dari

Cuaca sehingga mudah terjadi pemudaran lapisan cat dan korosi pada badan stoplog.

Jo
1.7 Dokumentasi Kondisi Ekisting Trash rake Intake

Unit Automatic Trashrake tipe Robotic MEH Chute yang kurang tinggi pada konveyor

Bar screen yag sudah mulai terjadi Korosi Pemindahan sampah yang kurang sempurna dari konveyor

Incline Conveyor Atap yang terbuka pada area fasilitas intake

Catatan :

Trashrake dengan tipe robotic (MECH) berfungsi dengan baik namun demikian fasilitas tersebut baru terdapat 1-Unit

Lengan pengankat sampah sehingga tidak efektif kalau untuk melayani 3 saluran intake secara bergantian. Mengingat

Volume sampah yang banyak terutama pada saat terjadi hujan

Jo
1.8 Dokumentasi Kondisi Ekisting Rumah Pompa

Over Head Crane Pada Rumah Pompa Kerusakan pada badan pompa

Motor dan Gearbox Pompa Axial Vertical Pemindahan sampah yang kurang sempurna dari konveyor

Motor yang sudah tidak Digunakan Pompa Axial"B" yang sudah diganti dengan Axial submersible

Catatan :

Kondisi Pompa yang sudah sangat Tua yaitu kurang lebih 30 Tahun Untuk Pompa "A" dan Pompa "B" dan 10 Tahun

Untuk Pompa "C" juga dengan performa kapasitas yang sudah menurun, akan menjadi lebih efektif Jika semua unit

Pompa diganti dengan unit yang baru yang disesuaikan dengan kondisi pemipaan saat ini

Jo
1.8 Dokumentasi Data Unit Pompa Existing

Name Plate Pada Padan Pompa - Axial A dan B Name Plate - Axial Vertical 1993

Name Plate Pada Actuator Discharge Pipe Name Plate - Axial Vertical 1993

Motor yang sudah tidak Digunakan Name Plate pada Motor Pompa Axial

Catatan :

Pada Name Plate Terdapat Keterangan Power Motor 188 kW Dan Head 3.3 meter, Diperkirakan iini adalah data untuk

Unit pompa pertama kali dibuat Tahun 1996, dan ini diperkuat dengan data As Built Drawing yang ada, Sementara data

Pada Name Plate motor Power adalah 270 kW dan 325 Rpm ada kemungkinan unit Pompa telah diRubah untuk head nya

Jo
1.10 Dokumentasi Kondisi Ekisting Discharge Facility

Discharge Pipe Assembly Kerusakan-Kerusakan karena Usia dan Korosi

Flap Valve pada area discharge Actuator yang rusak

Stoplog pada area Discharge yang sudah rusak Pintu Air yang rusak dan berkarat

Catatan :

Semua fasilitas pada area Discharge sudah dalam keadaan rusak meskipun masih difungsikan, Pengunaan Pintu air

Dan stoplog Untuk saat ini sangat vital dikarenakan untuk menjaga air ROB dan kondisi pompa yang tidak maksimal

Namun pengunaan pintu air dan stoplog disini perlu dikaji lebih jauh jika Rumah pompa kali sentiong sudah beroperasi

Jo
HISTORICAL

2 SEJARAH RUMAH POMPA ANCOL (EXISTING)

Dari Hasil Pemeriksaan dan Pengumpulan data-data terhadap pompa Existing, Telah didapatkan data untuk masing-masing

Pompa Sebagai Berikut ini :

1 Kapasitas Rumah Pompa : 3x5 m3/sec 900 m3/min

2 Kapasitas Per Unit Pompa : 5.00 m3/sec 300 m3/min

3 Head Pompa : 3.30 m

4 Daya Motor : 188.20 kW

5 Speed : 325.00 Rpm

6 Frequency : 50 Hz

7 Diameter Pipa kolom : 1.50 m 1500 mm

8 Diameter Pipa Buang : 1.50 m 1500 mm

9 Jenis Pompa : Axial Vertical

10 Tahun Pembuatan : 1996

Sumber Data dari Keterangan ini adalah melalui pemeriksaan langsung dan Asbuilt drawing yang ada pada rumah pompa

Dan berdasarkan data dan informasi lainnya didapati bahwa ketiga unit pompa tersebut mengalami perubahan secara

dimensi dan spesifikasi pada tahun 2000 menjadi :

1 Kapasitas Rumah Pompa : 3x5 m3/sec 900 m3/min

2 Kapasitas Per Unit Pompa : 5.00 m3/sec 300 m3/min

3 Head Pompa : 5.00 m

4 Daya Motor : 270.00 kW

5 Speed : 325.00 Rpm

6 Frequency : 50 Hz

7 Diameter Pipa kolom : 1.50 m 1500 mm

8 Diameter Pipa Buang : 1.50 m 1500 mm

9 Jenis Pompa : Axial Vertical

10 Tahun Perubahan/Modifikasi : 2000

Dari Hasil Perubahan ini kemudian pada tahun 2013 salah satu pompa mengalami kerusakan dan dilakukan penggantian unit

yaitu Pompa "C" diganti dengan Pomp Axial Submersible dengan kapasitas 3.5m3/Sec, Dengan demikian sejak tahun 2013

3 3 3
Hingga tahun 2023 Kapasitas Rumah Pompa Ancol Menjadi 2 x 5 m /sec + 1 x 3.5 m /Sec = 13.5 m /Sec.

Pada tahun 2022 Seiring dibangun nya rumah Pompa Kali sentiong, Menjadikan skema pada rumah pompa Ancol Berubah

Dengan dialihkannya buangan kedalam pipa perpanjangan sejauh kurang lebih 280 meter, dan juga kinerja unit pompa yang

Sudah menurun maka Telah diputuskan Unit pompa Harus diganti dengan yang spesifikasi yang sesuai dengan kondisi.

Jo
ANALISA TEKNIS

3 ANALISA TEKNIS POMPA ANCOL

Analisa ini adalah Metode pendekatan untuk Pembuktian spesifikasi pompa dari mulai awal pembuatan/Pemasangan tahun 1996,

Perbaikan/Modifikasi tahun 2000, Penggantian Unit Pompa Tahun 2013 hingga, Kondisi Terakhir terkait pipa perpanjangan pada

Saat pelaksanaan pembangunan Rumah pompa Sentiong yang berjarak Kuramg lebih 300 meter dari pompa ancol.

Analisa Berupa perhitungan teknis sehingga dapat mengetahui Nilai, Ukuran dan besaran Spesifikasi pompa, dari setiap peruba-

hannya. Sehingga dapat dijadikan dasar untuk kondisi pompa terakhir (Saat ini).

Hasil analisa ini selanjutnya akan menjadi dasar penentuan spesifikasi secara teknis untuk penggantian Unit pompa agar sesuai

Dengan kondisi Pipa perpanjangan yang sudah terpasang.

Hasil Analisa Perhitungan ini mencakup :

1 Kapasitas Rumah Pompa

2 Kapasitas Unit Pompa

3 Head Pompa

4 Daya Motor

5 Speed

6 Frequency

7 Diameter Pipa kolom

8 Diameter Pipa Buang

9 Tinggi Pipa kolom

10 Panjang Pipa Buang

11 Jenis Pompa

12 Daya yang diperlukan

13 Besaran Arus listrik

14 Besaran Tegangan listrik

15 Efisiensi Pompa

16 Jenis Pompa yang ideal

Jo
Doc. No. : DA-P-01.00.00 POMPA - A,B,C (1996) SHEET/SHEETS : 1 2

1 PUMP DATA

1.1 Pump Capacity Q : 5.00 m3/sec 300 m3/min

1.2 Pump Head (Static) H : 3.30 m

1.3 Column Pipe Diamter Dc : 1.5 m

1.4 Colum Section Area Ac : 1.77 m2

1.5 Discharge Pipe Length L1 : 5.00 m

1.6 Discharge Pipe Dia. Dd : 1.5 m

1.7 Discharge Section Area Ad : 1.77 m2

1.8 Fluid Density  : 1020 kg/m3 0.00102 kg/Cm3

1.9 Kinematic Viscocity  : 0.0008 -

1.10 Gravity g : 9.8 m/sec

Q
1.11 Velocity v : 2.83 m/sec
A

1.12 Static Head Z : 3.30 m

v2
1.13 Head Velocity Hv : 0.41 m
2g

1.14 Pressure p : 32986.80 kg/m2 ------- 3.30 kg/Cm2

1.15 Hydraulic Power ph :

 x Q x g x h
Ph = = 165 kW
1000

1.16 Voltage V : 240 Volt Actual Check

1.17 Current I : 500 Ampere Actual Check

1.18 Cos Phi Cos : 0.9 - Actual Check

1.19 Power Incomming

Pe = 1.73 x V x I x Cos phi = 187 kW

1.20 Pump Efficiency

Ph
= 88 %
Ef = x 100%
Pe

Jones watt
Doc. No. : DA-P-01.00.00 POMPA - A,B,C (1996) SHEET/SHEETS : 2 2

2 PUMP POWER

Theoritical Power

Specific Gravity R : 1.02 Kg/Cm3

Teoritical Power Lw : 0.163 x R x Q x H = 164.60 kW

Breake Horse Power (BHP)

Lw
BHP : x 100 = 205.75 kW

Motor Power

Motor Power Mp : BHP x ( 1 + a ) = 226 kW

Motor Power Selected

Motor Power Selected Ms > Mp = 250 > 226 ------- OK

Motor Speed N : 210.00 RPM

Net Posistive Suction Head

NPSH : ( N
Q
) 43 = 11,386 m

S 3/4

Pump Torque

Mp
T : x 97400 = 115,952 Kg.Cm
N

No. Desriptions Pump Unit 1996 Actual Check Remarks

1 Pump Head 3.3 m 3.3 m OK Correct

2 Pump Efficiency 88 % 88 % OK Correct

3 Pump Capacity Desg. 5.0 m3/s 5.0 m3/s OK Correct

4 Pump Capacity Eff. 4.4 m3/s 4.4 m3/s OK Correct

5 Power Incoming 187 kW 188 kW OK Correct

6 Water Power (BHP) 206 kW 206 kW OK Correct

7 Pump Torque 115,952 kg.Cm 115,952 kg.Cm OK Correct

8 Pump Motor Power 226 kW 250 kW OK Correct

9 Pump Speed 210 Rpm 210 Rpm OK Correct

10 Pressure 4.0 Bar 4.0 Bar OK Correct

Jones watt
Doc. No. : DA-P-02.00.00 POMPA - A,B,C (2000) SHEET/SHEETS : 1 2

1 PUMP DATA

1.1 Pump Capacity Q : 5.00 m3/sec 300 m3/min

1.2 Pump Head (Static) H : 4.50 m

1.3 Column Pipe Diamter Dc : 1.5 m

1.4 Colum Section Area Ac : 1.77 m2

1.5 Discharge Pipe Length L1 : 5.00 m

1.6 Discharge Pipe Dia. Dd : 1.5 m

1.7 Discharge Section Area Ad : 1.77 m2

1.8 Fluid Density  : 1020 kg/m3 0.00102 kg/Cm3

1.9 Kinematic Viscocity  : 0.0008 -

1.10 Gravity g : 9.8 m/sec

Q
1.11 Velocity v : 2.83 m/sec
A

1.12 Static Head Z : 4.50 m

v2
1.13 Head Velocity Hv : 0.41 m
2g

1.14 Pressure p : 44982.00 kg/m2 ------- 4.50 kg/Cm2

1.15 Hydraulic Power ph :

 x Q x g x h
Ph = = 225 kW
1000

1.16 Voltage V : 380 Volt Actual Check

1.17 Current I : 450 Ampere Actual Check

1.18 Cos Phi Cos : 0.9 - Actual Check

1.19 Power Incomming

Pe = 1.73 x V x I x Cos phi = 266 kW

1.20 Pump Efficiency

Ph
= 84 %
Ef = x 100%
Pe

Jones watt
Doc. No. : DA-P-02.00.00 POMPA - A,B,C (2000) SHEET/SHEETS : 2 2

2 PUMP POWER

Theoritical Power

Specific Gravity R : 1.02 Kg/Cm3

Teoritical Power Lw : 0.163 x R x Q x H = 224.45 kW

Breake Horse Power (BHP)

Lw
BHP : x 100 = 265.70 kW

Motor Power

Motor Power Mp : BHP x ( 1 + a ) = 266 kW

Motor Power Selected

Motor Power Selected Ms > Mp = 270 > 266 ------- OK

Motor Speed N : 325.00 RPM

Net Posistive Suction Head

NPSH : ( N
Q
) 43 = 13,479 m

S 3/4

Pump Torque

Mp
T : x 97400 = 80,917 Kg.Cm
N

No. Desriptions Pump Unit 1996 Actual Check Remarks

1 Pump Head 4.5 m 4.5 m OK Correct

2 Pump Efficiency 84 % 84 % OK Correct

3 Pump Capacity Desg. 5.0 m3/s 5.0 m3/s OK Correct

4 Pump Capacity Eff. 4.2 m3/s 4.2 m3/s OK Correct

5 Power Incoming 266 kW 266 kW OK Correct

6 Water Power (BHP) 266 kW 266 kW OK Correct

7 Pump Torque 80,917 kg.Cm 80,917 kg.Cm OK Correct

8 Pump Motor Power 224 kW 270 kW OK Correct

9 Pump Speed 325 Rpm 325 Rpm OK Correct

10 Pressure 4.0 Bar 4.0 Bar OK Correct

Jones watt
Doc. No. : DC-P-03.00.00 ANALISA POMPA - C (2013) SHEET/SHEETS : 1 2

1 PUMP DATA

1.1 Pump Capacity Q : 3.50 m3/sec 210 m3/min

1.2 Pump Head (Static) H : 5.00 m

1.3 Column Pipe Diamter Dc : 1.35 m

1.4 Colum Section Area Ac : 1.43 m2

1.5 Discharge Pipe Length L1 : 5.00 m

1.6 Discharge Pipe Dia. Dd : 1.35 m

1.7 Discharge Section Area Ad : 1.43 m2

1.8 Fluid Density  : 1020 kg/m3 0.00102 kg/Cm3

1.9 Kinematic Viscocity  : 0.0008 -

1.10 Gravity g : 9.8 m/sec

Q
1.11 Velocity v : 2.45 m/sec
A

1.12 Static Head Z : 5.00 m

v2
1.13 Head Velocity Hv : 0.31 m
2g

1.14 Pressure p : 49980.00 kg/m2 ------- 5.00 kg/Cm2

1.15 Hydraulic Power ph :

 x Q x g x h
Ph = = 175 kW
1000

1.16 Voltage V : 380 Volt Actual Check

1.17 Current I : 495 Ampere Actual Check

1.18 Cos Phi Cos : 0.9 - Actual Check

1.19 Power Incomming

Pe = 1.73 x V x I x Cos phi = 293 kW

1.20 Pump Efficiency

Ph
= 60 %
Ef = x 100%
Pe

Jones watt
Doc. No. : DC-P-03.00.00 ANALISA POMPA - C (2013) SHEET/SHEETS : 2 2

2 PUMP POWER

Theoritical Power

Specific Gravity R : 1.02 Kg/Cm3

Teoritical Power Lw : 0.163 x R x Q x H = 174.57 kW

Breake Horse Power (BHP)

Lw
BHP : x 100 = 218.22 kW

Motor Power

Motor Power Mp : BHP x ( 1 + a ) = 240 kW

Motor Power Selected

Motor Power Selected Ms > Mp = 260 > 240 ------- OK

Motor Speed N : 420.00 RPM

Net Posistive Suction Head

NPSH : ( N
Q
) 43 = 12,997 m

S 3/4

Pump Torque

Mp
T : x 97400 = 60,295 Kg.Cm
N

No. Desriptions Existing Replacement Check Remarks

1 Pump Head 4.5 m 5.0 m OK Correct

2 Pump Efficiency 84.5 % 80 % Err Decline

3 Pump Capacity Desg. 5.0 m3/s 3.5 m3/s Err Decline

4 Pump Capacity Eff. 4.2 m3/s 2.8 m3/s Err Decline

5 Power Incoming 266.2 kW 293 kW OK Over

6 Water Power (BHP) 265.7 kW 218 kW Err Decline

7 Pump Torque 80,916.9 kg.Cm 60,295 kg.Cm Err Decline

8 Pump Motor Power 270.0 kW 260 kW Err Decline

9 Pressure 4.0 Bar 3.0 Bar Err Decline

Jones watt
Doc. No. : DA-P-04.00.00 PERPANJANGAN PIPA - (1) SHEET/SHEETS : 1 5

1 Design Condition Of Water Level

1.1 Sill. Elevation : - 4.60 Elevasi dasar kolakan pompa

1.2 Low Water level : - 2.36 Elevasi Air Rendah

1.3 Normal Water level : + 0.20 Elevasi Air Hulu normal

1.4 High Water level : + 0.70 Elevasi Air Hulu tinggi

1.5 Flood Water level : + 1.00 Elevasi Air Banjir

2 Design Condition Of Pump

2.1 Pitch Blade axis : - 3.20 Elevasi Horiizontal Impeller

2.2 Pump Base Elevation : + 0.40 Elevasi Dudukan Column Pipe

2.3 Discharge Elevation : + 2.00 Elevasi center pipa buang + 1.98 (Ex.)

2.4 Head Static - 1 h1 : 5.20 m

2.5 Length of Discharge - 1 L1 : 5.00 m

3 Design Condition Of Discharge Pipe

3.1 Discharge Elevation - 2 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-2

3.2 Length of Discharge - 2 L2 : 10.00 m

3.3 Diameter of Pipe - 2 D2 : 1.60 m

3.4 Discharge Elevation - 3 : + 3.70 Elevasi Horiizontal Pipa buang perpanjangan Seqment-3

3.5 Length of Discharge - 3 L3 : 18.00 m

3.6 Diameter of Pipe - 3 D3 : 1.60 m

3.7 Discharge Elevation - 4 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-4

3.8 Length of Discharge - 4 L4 : 5.00 m

3.9 Diameter of Pipe - 4 D4 : 1.60 m

3.10 Discharge Elevation - 5 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-5

3.11 Length of Discharge - 5 L5 : 117.00 m

3.12 Diameter of Pipe - 5 D5 : 1.60 m

3.10 Discharge Elevation - 6 : + 3.70 Elevasi Horiizontal Pipa buang perpanjangan Seqment-6

3.11 Length of Discharge - 6 L6 : 12.00 m

3.12 Diameter of Pipe - 6 D6 : 1.60 m

3.13 Discharge Elevation - 7 : + 1.44 Elevasi Horiizontal Pipa buang perpanjangan Seqment-6

3.14 Length of Discharge - 7 L7 : 6.00 m

3.15 Diameter of Pipe - 7 D7 : 1.60 m


Jones watt
Doc. No. : DA-P-04.00.00 PERPANJANGAN PIPA - (1) SHEET/SHEETS : 2 5

4 Design Condition Of Discharge Culvert

4.1 Discharge Elevation - 8 : + 1.44 Elevasi Horiizontal Center Box Culvert

4.2 Length of Culvert LC 1 : 78.00 m

4.3 High of Culvert HC 1 : 3.00 m

4.4 Wide of Culvert W 1 : 2.00 m

5 Pump Head

5.1 Static Head

Head Static - 1 h1 : 5.20 m Column to Discharge

Discharge Elevation He : + 3.70 Elevasi Tertinggi dari pipa buang

Head Static - 2 h2 : 1.70 m Discharge-1 ke discharge tertinggi

Total static Head H : 6.90 m h = h1 + h2

Selected Hs : 7.00 m Ok

+ 3.70
Em

h 2 = 1.70

Em
+ 2.00

ef

Wp

h 1 = 5.20

-3.20 Horizontal Pitch Impeller

Static Head Diagram Pompa - A


Doc. No. : DA-P-04.00.00 PUMP UNIT - (A) SHEET/SHEETS : 3 5

5.2 Headloss

Total Static Head Hs : 7.00 m Column to Higest of discharge Pipe

Pipe diamater D : 1.60 m

Area A : 2.01 m2

Capacity Q : 5.00 m3/Sec


Q
Velocity v : 2.49 m/s v =
A

Reynold Number

Density of water  : 997 Kg/m3

Kinematic Viscocity  : 0.000801 -

v x D1
Re = = 4,967 Turbulence

64
f = = 0.01288
Re

Relative Roughness

Steel Pipe Coefficient  : 100 - Hazen William

Steel Pipe Coefficient  : 0.045 mm Darcy -Waisbach


Relative Roughness = = 0.00003
d

Hazen-William

Total Length L : 251.00 M

HF lm =
( 0.28 x 100
Q

x D 1 2.63
)) 1.85
L = 1.063 m

Darcy - Weisbach

( ) ( )
L v2
HF W = f = 0.637 m
D 2g

Total Head Loss

HF lm : 1.063 m

Pump Head

Hp : Hs + HF lm = 8.06 m

Selected = 8.50 m

Jones watt
Doc. No. : DA-P-04.00.00 PUMP UNIT - (A) SHEET/SHEETS : 4 5

6 Pressure loss

P = = 1.024 Bar
0.0981 x HF IM x g

P = = 0.614 Bar
0.0981 x HF w x g

7 Energy lossis friction

( ) ( )
L1 v2 J
 Ef = f = ………… m2/s2 Or
D1 2 Kg

No. Seqment f L D V V2  Ef Unit

1 Length of discharge pipe -1 0.013 5.000 1.500 2.487 6.184 0.133 m 2 /s 2

2 Length of discharge pipe -2 0.013 10.000 1.600 2.487 6.184 0.249 m 2 /s 2

3 Length of discharge pipe -3 0.013 18.000 1.600 2.487 6.184 0.448 m 2 /s 2

4 Length of discharge pipe -4 0.013 5.000 1.600 2.487 6.184 0.124 m 2 /s 2

5 Length of discharge pipe -5 0.013 117.000 1.600 2.487 6.184 2.913 m 2 /s 2

6 Length of discharge pipe -6 0.013 12.000 1.600 2.487 6.184 0.299 m 2 /s 2

7 Length of discharge pipe -7 0.013 6.000 1.600 2.487 6.184 0.149 m 2 /s 2

8 Box Culvert 0.013 78.000 2.000 0.414 0.172 0.043 m 2 /s 2

Total energy Lossis friction 4.359 m 2 /s 2

8 Energy lossis Bend

k1 (elbow 45) = 16 x f = 0.20614

k2 (elbow 90) = 30 x f = 0.38652

k3 (Butterfly) = 8x f = 0.10307

v2 J
 em = (k 1 + k 2 + k 3 ) = 2.151 m2/S2 Or
2 Kg

P2 - P1 v2 2 -v1 2
E2 - E1 = + + g (Z 2 - Z 1 )
 2

= 0 + 0 + 79.102

= 79.102 J/kg

J
WP = (E 2 -E 1 ) +  Ef +  em = 85.61
Kg

Mass m :  x A x v = 4985 Kg/s


Doc. No. : DA-P-04.00.00 PUMP UNIT - (A) SHEET/SHEETS : 5 5

9 Pump Power

WP = WP x m = 426776.84 Watt

= 427 kW

= 270 kW Err

10 Motor Power

Pump Capacity Q : 5.00 m3/Sec 300.00 m3/min

Total Head h : 8.06 m

Pump Power P : 270 kW

Voltage V : 380 Volt Check

Current I : 760 Ampere Check

Cos Phi Cos : 0.9 -

Frequency f : 50 Hz

Number of Pole p : 14 Pole

Angle Of Phase d : 120 -

Motor Speed N : 1500 Rpm

Density of water  : 997 Kg/m3

Pump Speed N1 : 400 Rpm Base from condition

Gravity g : 9.8 M/Sec2

Power Incomming

Pe = 1.73 x V x I x Cos phi = 450 kW

Water Power

 x Q x g x h
Pw = = 394 kW
1000

Pump Efficiency

Pe
= 88 %
 = x 100%
Pw

Teoritical Power Lw : 0.163 x R x Q x H = 393 kW

Power required (BHP)

Lw
BHP : x 100 = 449 kW

Motor Power Mp : BHP x ( 1 + a ) = 449 kW

Motor Power Existing Ms > Mp = 270 > 449 ------- Err

Jones watt
Doc. No. : DA-P-05.00.00 PERPANJANGAN PIPA - (2) SHEET/SHEETS : 1 5

1 Design Condition Of Water Level

1.1 Sill. Elevation : - 4.60 Elevasi dasar kolakan pompa

1.2 Low Water level : - 2.36 Elevasi Air Rendah

1.3 Normal Water level : + 0.20 Elevasi Air Hulu normal

1.4 High Water level : + 0.70 Elevasi Air Hulu tinggi

1.5 Flood Water level : + 1.00 Elevasi Air Banjir

2 Design Condition Of Pump

2.1 Pitch Blade axis : - 3.20 Elevasi Horiizontal Impeller

2.2 Pump Base Elevation : + 0.40 Elevasi Dudukan Column Pipe

2.3 Discharge Elevation : + 2.00 Elevasi center pipa buang + 1.98 (Ex.)

2.4 Head Static - 1 h1 : 5.20 m

2.5 Length of Discharge - 1 L1 : 5.00 m

3 Design Condition Of Discharge Pipe

3.1 Discharge Elevation - 2 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-2

3.2 Length of Discharge - 2 L2 : 10.00 m

3.3 Diameter of Pipe - 2 D2 : 1.60 m

3.4 Discharge Elevation - 3 : + 3.70 Elevasi Horiizontal Pipa buang perpanjangan Seqment-3

3.5 Length of Discharge - 3 L3 : 18.00 m

3.6 Diameter of Pipe - 3 D3 : 1.80 m

3.7 Discharge Elevation - 4 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-4

3.8 Length of Discharge - 4 L4 : 5.00 m

3.9 Diameter of Pipe - 4 D4 : 1.80 m

3.10 Discharge Elevation - 5 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-5

3.11 Length of Discharge - 5 L5 : 117.00 m

3.12 Diameter of Pipe - 5 D5 : 1.80 m

3.10 Discharge Elevation - 6 : + 3.70 Elevasi Horiizontal Pipa buang perpanjangan Seqment-6

3.11 Length of Discharge - 6 L6 : 12.00 m

3.12 Diameter of Pipe - 6 D6 : 1.80 m

3.13 Discharge Elevation - 7 : + 1.44 Elevasi Horiizontal Pipa buang perpanjangan Seqment-6

3.14 Length of Discharge - 7 L7 : 6.00 m

3.15 Diameter of Pipe - 7 D7 : 1.80 m


Jones watt
Doc. No. : DA-P-04.00.00 PERPANJANGAN PIPA - (2) SHEET/SHEETS : 2 5

4 Design Condition Of Discharge Culvert

4.1 Discharge Elevation - 8 : + 1.44 Elevasi Horiizontal Center Box Culvert

4.2 Length of Culvert LC 1 : 78.00 m

4.3 High of Culvert HC 1 : 3.00 m

4.4 Wide of Culvert W 1 : 2.00 m

5 Pump Head

5.1 Static Head

Head Static - 1 h1 : 5.20 m Column to Discharge

Discharge Elevation He : + 3.70 Elevasi Tertinggi dari pipa buang

Head Static - 2 h2 : 1.70 m Discharge-1 ke discharge tertinggi

Total static Head H : 6.90 m h = h1 + h2

Selected Hs : 7.00 m Ok

+ 3.70
Em

h 2 = 1.70

Em
+ 2.00

ef

Wp

h 1 = 5.20

-3.20 Horizontal Pitch Impeller

Static Head Diagram Pompa - B


Doc. No. : DA-P-04.00.00 PUMP UNIT - (B) SHEET/SHEETS : 3 5

5.2 Headloss

Total Static Head Hs : 7.00 m Column to Higest of discharge Pipe

Pipe diamater D : 1.80 m

Area A : 2.54 m2

Capacity Q : 5.00 m3/Sec


Q
Velocity v : 1.96 m/s v =
A

Reynold Number

Density of water  : 997 Kg/m3

Kinematic Viscocity  : 0.000801 -

v x D1
Re = = 4,415 Turbulence

64
f = = 0.01449
Re

Relative Roughness

Steel Pipe Coefficient  : 100 - Hazen William

Steel Pipe Coefficient  : 0.045 mm Darcy -Waisbach


Relative Roughness = = 0.00003
d

Hazen-William

Total Length L : 251.00 M

HF lm =
( 0.28 x 100
Q

x D 1 2.63
)) 1.85
L = 0.600 m

Darcy - Weisbach

( ) ( )
L v2
HF W = f = 0.398 m
D 2g

Total Head Loss

HF lm : 0.600 m

Pump Head

Hp : Hs + HF lm = 7.60 m

Selected = 8.00 m

Jones watt
Doc. No. : DA-P-04.00.00 PUMP UNIT - (B) SHEET/SHEETS : 4 5

6 Pressure loss

P = = 0.578 Bar
0.0981 x HF IM x g

P = = 0.383 Bar
0.0981 x HF w x g

7 Energy lossis friction

( ) ( )
L1 v2 J
 Ef = f = ………… m2/s2 Or
D1 2 Kg

No. Seqment f L D V V2  Ef Unit

1 Length of discharge pipe -1 0.014 5.000 1.500 1.965 3.861 0.093 m 2 /s 2

2 Length of discharge pipe -2 0.014 10.000 1.600 1.965 3.861 0.175 m 2 /s 2

3 Length of discharge pipe -3 0.014 18.000 1.600 1.965 3.861 0.315 m 2 /s 2

4 Length of discharge pipe -4 0.014 5.000 1.600 1.965 3.861 0.087 m 2 /s 2

5 Length of discharge pipe -5 0.014 117.000 1.600 1.965 3.861 2.046 m 2 /s 2

6 Length of discharge pipe -6 0.014 12.000 1.600 1.965 3.861 0.210 m 2 /s 2

7 Length of discharge pipe -7 0.014 6.000 1.600 1.965 3.861 0.105 m 2 /s 2

8 Box Culvert 0.014 78.000 2.000 0.327 0.107 0.030 m 2 /s 2

Total energy Lossis friction 3.061 m 2 /s 2

8 Energy lossis Bend

k1 (elbow 45) = 16 x f = 0.23191

k2 (elbow 90) = 30 x f = 0.43484

k3 (Butterfly) = 8x f = 0.11596

v2 J
 em = (k 1 + k 2 + k 3 ) = 1.511 m2/S2 Or
2 Kg

P2 - P1 v2 2 -v1 2
E2 - E1 = + + g (Z 2 - Z 1 )
r 2

= 0 + 0 + 74.551

= 74.551 J/kg

J
WP = (E 2 -E 1 ) +  Ef +  em = 79.12
Kg

Mass m :  x A x v = 4985 Kg/s


Doc. No. : DA-P-04.00.00 PUMP UNIT - (B) SHEET/SHEETS : 5 5

9 Pump Power

WP = WP x m = 394432.10 Watt

= 394 kW

= 270 kW Err

10 Motor Power

Pump Capacity Q : 5.00 m3/Sec 300.00 m3/min

Total Head h : 7.60 m

Pump Power P : 270 kW

Voltage V : 380 Volt Check

Current I : 760 Ampere Check

Cos Phi Cos : 0.9 -

Frequency f : 50 Hz

Number of Pole p : 14 Pole

Angle Of Phase d : 120 -

Motor Speed N : 1500 Rpm

Density of water  : 997 Kg/m3

Pump Speed N1 : 400 Rpm Base from condition

Gravity g : 9.8 M/Sec2

Power Incomming

Pe = 1.73 x V x I x Cos phi = 450 kW

Water Power

 x Q x g x h
Pw = = 371 kW
1000

Pump Efficiency

Pe
= 83 %
 = x 100%
Pw

Teoritical Power Lw : 0.163 x R x Q x H = 371 kW

Power required (BHP)

Lw
BHP : x 100 = 449 kW

Motor Power Mp : BHP x ( 1 + a ) = 449 kW

Motor Power Existing Ms > Mp = 270 > 449 ------- Err

Jones watt
Doc. No. : DA-P-05.00.00 PERPANJANGAN PIPA - (2) SHEET/SHEETS : 1 5

1 Design Condition Of Water Level

1.1 Sill. Elevation : - 4.60 Elevasi dasar kolakan pompa

1.2 Low Water level : - 2.36 Elevasi Air Rendah

1.3 Normal Water level : + 0.20 Elevasi Air Hulu normal

1.4 High Water level : + 0.70 Elevasi Air Hulu tinggi

1.5 Flood Water level : + 1.00 Elevasi Air Banjir

2 Design Condition Of Pump

2.1 Pitch Blade axis : - 3.20 Elevasi Horiizontal Impeller

2.2 Pump Base Elevation : + 0.40 Elevasi Dudukan Column Pipe

2.3 Discharge Elevation : + 2.00 Elevasi center pipa buang + 1.98 (Ex.)

2.4 Head Static - 1 h1 : 5.20 m

2.5 Length of Discharge - 1 L1 : 5.00 m

3 Design Condition Of Discharge Pipe

3.1 Discharge Elevation - 2 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-2

3.2 Length of Discharge - 2 L2 : 10.00 m

3.3 Diameter of Pipe - 2 D2 : 1.80 m

3.4 Discharge Elevation - 3 : + 3.70 Elevasi Horiizontal Pipa buang perpanjangan Seqment-3

3.5 Length of Discharge - 3 L3 : 18.00 m

3.6 Diameter of Pipe - 3 D3 : 1.80 m

3.7 Discharge Elevation - 4 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-4

3.8 Length of Discharge - 4 L4 : 5.00 m

3.9 Diameter of Pipe - 4 D4 : 1.80 m

3.10 Discharge Elevation - 5 : + 2.00 Elevasi Horiizontal Pipa buang perpanjangan Seqment-5

3.11 Length of Discharge - 5 L5 : 117.00 m

3.12 Diameter of Pipe - 5 D5 : 1.80 m

3.10 Discharge Elevation - 6 : + 3.70 Elevasi Horiizontal Pipa buang perpanjangan Seqment-6

3.11 Length of Discharge - 6 L6 : 12.00 m

3.12 Diameter of Pipe - 6 D6 : 1.80 m

3.13 Discharge Elevation - 7 : + 1.44 Elevasi Horiizontal Pipa buang perpanjangan Seqment-6

3.14 Length of Discharge - 7 L7 : 6.00 m

3.15 Diameter of Pipe - 7 D7 : 1.80 m


Jones watt
Doc. No. : DA-P-04.00.00 PERPANJANGAN PIPA - (2) SHEET/SHEETS : 2 5

4 Design Condition Of Discharge Culvert

4.1 Discharge Elevation - 8 : + 1.44 Elevasi Horiizontal Center Box Culvert

4.2 Length of Culvert LC 1 : 78.00 m

4.3 High of Culvert HC 1 : 3.00 m

4.4 Wide of Culvert W 1 : 2.00 m

5 Pump Head

5.1 Static Head

Head Static - 1 h1 : 5.20 m Column to Discharge

Discharge Elevation He : + 3.70 Elevasi Tertinggi dari pipa buang

Head Static - 2 h2 : 1.70 m Discharge-1 ke discharge tertinggi

Total static Head H : 6.90 m h = h1 + h2

Selected Hs : 7.00 m Ok

+ 3.70
Em

h 2 = 1.70

Em
+ 2.00

ef

Wp

h 1 = 5.20

-3.20 Horizontal Pitch Impeller

Static Head Diagram Pompa - C


Doc. No. : DA-P-04.00.00 PUMP UNIT - (C) SHEET/SHEETS : 3 5

5.2 Headloss

Total Static Head Hs : 7.00 m Column to Higest of discharge Pipe

Pipe diamater D : 1.80 m

Area A : 2.54 m2

Capacity Q : 3.50 m3/Sec


Q
Velocity v : 1.38 m/s v =
A

Reynold Number

Density of water  : 997 Kg/m3

Kinematic Viscocity  : 0.000801 -

v x D1
Re = = 3,091 Turbulence

64
f = = 0.02071
Re

Relative Roughness

Steel Pipe Coefficient  : 100 - Hazen William

Steel Pipe Coefficient  : 0.045 mm Darcy -Waisbach


Relative Roughness = = 0.00003
d

Hazen-William

Total Length L : 251.00 M

HF lm =
( 0.28 x 100
Q

x D 1 2.63
)) 1.85
L = 0.310 m

Darcy - Weisbach

( ) ( )
L v2
HF W = f = 0.278 m
D 2g

Total Head Loss

HF lm : 0.310 m

Pump Head

Hp : Hs + HF lm = 7.31 m

Selected = 8.00 m

Jones watt
Doc. No. : DA-P-04.00.00 PUMP UNIT - (C) SHEET/SHEETS : 4 5

6 Pressure loss

P = = 0.299 Bar
0.0981 x HF IM x g

P = = 0.268 Bar
0.0981 x HF w x g

7 Energy lossis friction

( ) ( )
L1 v2 J
 Ef = f = ………… m2/s2 Or
D1 2 Kg

No. Seqment f L D V V2  Ef Unit

1 Length of discharge pipe -1 0.021 5.000 1.500 1.375 1.892 0.065 m 2 /s 2

2 Length of discharge pipe -2 0.021 10.000 1.600 1.375 1.892 0.122 m 2 /s 2

3 Length of discharge pipe -3 0.021 18.000 1.600 1.375 1.892 0.220 m 2 /s 2

4 Length of discharge pipe -4 0.021 5.000 1.600 1.375 1.892 0.061 m 2 /s 2

5 Length of discharge pipe -5 0.021 117.000 1.600 1.375 1.892 1.432 m 2 /s 2

6 Length of discharge pipe -6 0.021 12.000 1.600 1.375 1.892 0.147 m 2 /s 2

7 Length of discharge pipe -7 0.021 6.000 1.600 1.375 1.892 0.073 m 2 /s 2

8 Box Culvert 0.021 78.000 2.000 0.229 0.053 0.021 m 2 /s 2

Total energy Lossis friction 2.143 m 2 /s 2

8 Energy lossis Bend

k1 (elbow 45) = 16 x f = 0.33130

k2 (elbow 90) = 30 x f = 0.62120

k3 (Butterfly) = 8x f = 0.16565

v2 J
 em = (k 1 + k 2 + k 3 ) = 1.058 m2/S2 Or
2 Kg

P2 - P1 v2 2 -v1 2
E2 - E1 = + + g (Z 2 - Z 1 )
r 2

= 0 + 0 + 71.710

= 71.710 J/kg

J
WP = (E 2 -E 1 ) +  Ef +  em = 74.91
Kg

Mass m :  x A x v = 3489.5 Kg/s


Doc. No. : DA-P-04.00.00 PUMP UNIT - (C) SHEET/SHEETS : 5 5

9 Pump Power

WP = WP x m = 261401.72 Watt

= 261 kW

= 260 kW Err

10 Motor Power

Pump Capacity Q : 3.50 m3/Sec 210.00 m3/min

Total Head h : 7.31 m

Pump Power P : 260 kW

Voltage V : 380 Volt Check

Current I : 495 Ampere Check

Cos Phi Cos : 0.9 -

Frequency f : 50 Hz

Number of Pole p : 14 Pole

Angle Of Phase d : 120 -

Motor Speed N : 1500 Rpm

Density of water  : 997 Kg/m3

Pump Speed N1 : 420 Rpm Base from condition

Gravity g : 9.8 M/Sec2

Power Incomming

Pe = 1.73 x V x I x Cos phi = 293 kW

Water Power

 x Q x g x h
Pw = = 250 kW
1000

Pump Efficiency

Pe
= 85 %
 = x 100%
Pw

Teoritical Power Lw : 0.163 x R x Q x H = 249 kW

Power required (BHP)

Lw
BHP : x 100 = 292 kW

Motor Power Mp : BHP x ( 1 + a ) = 292 kW

Motor Power Existing Ms > Mp = 260 > 292 ------- Err

Jones watt
Doc. No. : DA-P-05.00.00 SUMMARRY - 2022 SHEET/SHEETS : 1 2

Pump "A" After Discharge Pipe Extention

No. Desriptions Pump Unit 2000 Pump Unit 2022 Check Remarks

1 Pump Head 4.5 m 7.0 m Err Droped

2 Pump Efficiency 84 % 88 % Err Droped

3 Pump Capacity Desg. 5.0 m3/s 5.0 m3/s Err Droped

4 Pump Capacity Eff. 4.2 m3/s 4.4 m3/s Err Droped

5 Power Incoming 266 kW 450 kW Err Droped

6 Water Power (BHP) 266 kW 449 kW Err Droped

7 Pump Torque 80917 kg.Cm 109,269 kg.Cm Err Droped

8 Pump Motor Power 270 kW 449 kW Err Droped

9 Pump Speed 325 Rpm 210 Rpm Err Droped

10 Pressure 4.0 Bar 4.0 Bar Err Droped

Pump "B" After Discharge Pipe Extention

No. Desriptions Pump Unit 2000 Pump Unit 2022 Check Remarks

1 Pump Head 4.5 m 7.0 m Err Droped

2 Pump Efficiency 84 % 88 % Err Droped

3 Pump Capacity Desg. 5.0 m3/s 5.0 m3/s Err Droped

4 Pump Capacity Eff. 4.2 m3/s 4.4 m3/s Err Droped

5 Power Incoming 266 kW 450 kW Err Droped

6 Water Power (BHP) 266 kW 449 kW Err Droped

7 Pump Torque 80,917 kg.Cm 109,269 kg.Cm Err Droped

8 Pump Motor Power 224 kW 449 kW Err Droped

9 Pump Speed 325 Rpm 210 Rpm Err Droped

10 Pressure 4.0 Bar 4.0 Bar Err Droped

Jones watt
Doc. No. : DA-P-04.00.00 SUMMARRY - 2022 SHEET/SHEETS : 2 2

Pump "C" After Discharge Pipe Extention

No. Desriptions Pump Unit 2013 Pump Unit 2022 Check Remarks

1 Pump Head 5.0 m 8.0 m Err Droped

2 Pump Efficiency 80 % 85 % Err Droped

3 Pump Capacity Desg. 3.5 m3/s 3.5 m3/s Err Droped

4 Pump Capacity Eff. 2.8 m3/s 3.0 m3/s Err Droped

5 Power Incoming 293 kW 293 kW Err Droped

6 Water Power (BHP) 218 kW 261 kW Err Droped

7 Pump Torque 60,295 kg.Cm 67,780 kg.Cm Err Droped

8 Pump Motor Power 260 kW 292 kW Err Droped

9 Pump Speed 420 Rpm 210 Rpm Err Droped

10 Pressure 3.0 Bar 4.0 Bar Err Droped

Dari hasil analisa ini Telah didapatkan data secara teoritis bahwa ketiga Pompa mengalami penurunan performa atau ketidak

Mampuan akibat dari perpanjangan pipa buang (Discharge Pipe) yang mengakibatkan system kelistrikan dalam pengoperasian

Menjadi terganggu dan operasi pompa tidak lagi maksimal dalam segala hal dengan kata lain, semua unit pompa tersebut sudah

tidak dapat lagi digunakan, Karena pompa juga sudah mengalami kerusakan-kerusakan secsra fisik dan secara sistim.

Pompa "A" dengan usia yang sudah tua dan juga mengalami modifikasi sudah tentu mengalami penurunan performa terhadap

Kapasitas dan efisiensi sehingga ketika terjadi perubahan system pada saluran buang pompa "A" sudah tidak mampu bekerja

Secara maksimal bahkan hanya sekitar 5% saja dari kemampuan awal jika pompa tersebut diaksakan untuk beroperasi.

Kondisi Pompa "B" hampir sama dengan pompa "A" meskipun ada perbedaan nilai namun kondisi pompa "B" Juga mengalami

Penurunan performa yang drastis akibat sistem perpanjangan pipa buang.

Secara maksimal bahkan hanya sekitar 5% saja dari kemampuan awal jika pompa tersebut diaksakan untuk beroperasi.

Pompa "C" Meskipun dengan usia yang lebih muda (Baru) juga mengalami hal yang sama dengan kedua pompa lainnya. Karena

Semua tergabung dalam satu kesatuan sistem pemipaan.


REKOMENDASI

4 REKOMENDASI TEKNIS POMPA ANCOL

Dari hasil analisa menunjukan Pompa-pompa pada stasiun pompa banjir Ancol tidak bisa atau tidak mampu untuk terintegrasi

Dengan system yang baru, Oleh karena itu direkomendasikan untuk mengganti unit pompa-pompa tersebut agar dapat mengem-

balikan fungsi dan kemampuan stasiun pompa banjir ancol yang dapat terintegrasi dengan sistem perencanaan yang baru terkait

dibangunnya stasiun pompa banjir sentiong.

Pemilihan/Penentuan Jenis dan spesifikasi pompa pengganti akan menjadi hal yang paling penting dalam proses penyesuaian ini

Pemilihan dan penentuan jenis pompa penganti ini tentu saja harus malalui proses pertimbangan-pertimbangan yang akan menjadi

Dasar kriteria disain Rehabilitasi Rumah pompa Ancol, Pertimbangan-pertimbangan itu antara lain:

1 Kapasitas Rumah Pompa

2 Kapasitas Unit Pompa

3 Head Pompa

4 Jenis Pompa

5 Tipe Pompa

6 Struktur bangunan rumah pompa

7 Ukuran dan berat pompa

8 Komponen pendukung Unit Pompa

9 Sistem Kelistrikan

10 Biaya penggantian

11 Waktu pelaksanaan pekerjaan

12 Tingkat komponen Dalam Negri (TKDN)

13 Ketersediaan Komponen Pompa

14 Biaya Perawatan Dan perbaikan Pompa

15 Kemudahan Pengoperasian

Pertimbangan-Pertimbangan tersebut menjadi dasar perbandingan untuk menentukan tipe dan jenis pompa yang akan dipilih untuk

Menggantikan unit pompa yang ada.

Jo
REKOMENDASI

4.1 KAPASITAS RUMAH POMPA

Kapasitas Rumah pompa banjir Ancol Saat awal pembangunan adalah 15m3/detik, yang mana didalam nya terdapat 3 Unit

pompa dengan tipe Axial Vertical masing-masing berkapasitas 5m3/Detik, Rumah pompa dibangun dengan bentuk yang konven-

Sional mengikuti standard bangunan rumah pompa banjir. Saat ini rumah pompa Ancol berusia Kurang lebih 30 Tahun sejak

Awal dibangun. Dan mengenai unit pompa sendiri sudah mengalami modifikasi fisik dan perbaikan-perbaikan.

3
Sampai pada tahun 2022 kapasitas rumah pompa banjir Ancol menjadi 13.5 m /detik, hal dikarenakan adanya penggantian

3 3
salah satu unit pompa 5m /Detik dengan tipe Axial Vertical menjadi 3.5 m /Detik dengan tipe Axial Submersible, Tidak diketahui

dengan pasti perubahan Kapasitas pompa tersebut namun secara fisik saat itu salah satu pompa Axial memang harus digantikan.

Dari kronologis tersebut dapat disimpulkan bahwa akan menjadi lebih baik Jika Kapasitas Rumah pompa banjir Ancol dikem-

3/
Balikan Menjadi 15 m Detik.

4.2 KAPASITAS UNIT POMPA

Seperti yang telah dijabarkan sebelum nya bahwa kapasitas Per unit pompa di Rumah pompa Banjir Ancol Saat ini Adalah

2 x 5m3/detik dengan tipe axial Vertical dan 1 x 3.5m3/detik sehingga kapasitas Rumah pompa banjir Ancol saat ini sebesar

3 3
13.5 m /detik dan Jika kapasitas Rumah pompa Ancol akan dikembalikan menjadi 15 m /detik, atau lebih besar maka akan

menjadi banyak kombinasi untuk Kapasitas Per unit pompa yang kan kita pilih untuk pompa pengganti.

Kobinasi kapasitas unit pompa tersebut antara lain :

3 3 3 3 3
1 2 x 7.5 m /Detik + 3.5 m /detik = 18.5 m /detik, Menganti 2 unit Pompa 5m /d saja dan tetap memasang pompa 3.5 m /d

2 3 x 7.5 m3/Detik = 22.5 m3/detik, Menganti semua unit Pompa menjadi kapasitas 5 m3/det menjadi 7.5 m3/det

3 3 3 3 3
3 2 x 5.0 m /Detik + 3.5 m /detik = 13.5 m /detik, Menganti 2 unit Pompa 5m /d saja dan tetap memasang pompa 3.5 m /d

3 3 3
4 3 x 5.0 m /Detik = 15 m /detik, Menganti semua unit Pompa menjadi kapasitas 5 m /det namun dengan Head menjadi 8m

Perbandingan Varian Kapasitas Unit Pompa Terhadap Biaya

No. Varian Kapasitas Total Biaya mekanikal Biaya Elektrikal Biaya Struktur

3 3
1 2 x 7.5 m /det + 3.5 m /det 18.5 Sangat mahal Sangat mahal Sangat mahal

3
2 3 x 7.5 m /det 22.5 Sangat mahal Mahal Mahal

3 3
3 2 x 5.0 m /det + 3.5 m /det 13.5 Normal Cukup mahal Cukup mahal

3
4 3 x 5.0 m /det 15 Normal Normal Normal

Sangat Mahal : Adalah ketidak seimbangan biaya yang dikeluarkan untuk pekerjaan dengan hasil rehabilitasi rumah pompa

Mahal : Adalah katagori untuk tidak efisiennya hasil yang dicapai dengan biaya dan waktu pekerjaan

Normal : Adalah katagori seimbangnya Biaya, waktu pekerjaan dan efisiensi terhadap hasil rehabilitasi

Dari hasil perbandingan variasi penggunaan kapasitas per unit pompa diatas maka direkomendasikan kapasitas unit pompa

Mengarah ke 3 x 5.0 m3/det. Dan total kapasitas rumah pompa menjadi 15m3/det

Jo
REKOMENDASI

4.3 HEAD POMPA

Penentuan Head pompa pengganti disini juga menjadi hal yang sangat penting karena perubahan akibat pipa perpanjangan dan

Berubahnya sistem pembuangan rumah pompa ancol, Pada penjelasan sebelum nya melalui pendekatan dan analisa teknis

Telah diketahui bahwa akibat pipa perpanjangan masing-masing pompa telah mengalami penurunan performance termasuk

Penurunan daya karena Head total yang berubah, yang mana head tersebut adalah karena perubahan tinggi dan lossis yang

Terjadi pada Pipa perpanjangan. Dari hasil analisa dan perhitungan teoritis Head pompa yang tertinggi adalah 8.5 meter

Meskipun untuk kedua pompa lainnya memiliki angka perubahan yang berbeda namum disarankan untuk disamakan dengan head

Pompa yang tertinggi.

4.4 JENIS POMPA

Melihat kondisi struktur bangunan yang sedianya diperuntukan untuk jenis pompa tertentu dan untuk mengurangi bobot pekerjaan

Maka dalam hal ini akan menjadi lebih mudah jika pompa pengganti tetap menggunakan Jenis pompa yang sama yaitu pompa

Jenis Aksial / Axial Pump

4.5 TIPE POMPA

Pada Jenis Pompa Axial terdapat 2 buah tipe atau model yaitu Axial vertical dan Axial Submersible kedua tipe ini masih sangat

memungkinkan untuk diterapkan atau dipasang pada bangunan rumah pompa banjir Ancol, Karena keduanya pun memang sudah

ada ditempatkan dirumah pompa banjir Ancol.

Oleh karena hal tersebut maka perlu dilakukannya pengamatan dan perbandingan dari berbagai hal terkait dengan penyesuaian

Antara rumah pompa Eksisting dengan jenis dan tipe pompa yang akan dipilih sebagai pengganti.

Perbandingan Umum Tipe Pompa

No. Deskripsi Axial Vertical Axial Submersible Rekomendasi

1 Biaya / Unit kapasitas Lebih Murah Lebih Mahal Axial Vertical

2 Waktu Pengadaan 4 - 5 Bulan 7 - 10 Bulan Axial Vertical

3 Proses Installasi Sedikit lebih lama Sedikit lebih Cepat Axial Submersible

4 Pengoperasian Mudah dioperasikan Mudah dioperasikan Keduanya Sama

5 Perawatan dan perbaikan Mudah dilakukan Sulit dilakukan Axial Vertical

6 Ketersediaan Sparepart Mudah didapatkan / dibuat Harus pesan dan butuh waktu Axial Vertical

7 Masa pemakaian 20-30 Tahun 10 - 20 Tahun Axial Vertical


Tingkat Kandungan Dalam
8 40% - 51% 0% Axial Vertical
Negri (TKDN)
9 Ukuran dan Berat pompa Lebih berat dan lebih besar Lebih ringan dan lebih kecil Axial Submersible

10 Modifikasi/Upgrade pompa Mudah dilakukan Tidak bisa dilakukan Axial Vertical

Dari hasil perbandingan umum Jenis pompa merujuk pada Pompa dengan tipe Axial Vertical

Jo
REKOMENDASI

Selain hasil perbandingan terhadap masing-masing pompa secara umum, perlu juga diperhatikan untuk tipe pompa pengganti

Terhadap perubahan perubahan lain yang berkaitan, seperti perubahan pada struktur bangunan , sistem kelistrikan dan peralatan

atau perlengkapan lain yang mengikutinya sehingga menimbulkan pengaruh pada biaya pelaksanaan.

Perbandingan Tipe Pompa terhadap perubahan yang mengikuti

No. Deskripsi Axial Vertical Axial Submersible Rekomendasi

1 Perubahan struktur Perubahan untuk penyesuaian Banyak perubahan Axial Vertical

2 Sistem elektrikal Perubahan untuk penyesuaian Perubahan Total Axial Vertical

3 Perlengkapan lain tidak ada Banyak perubahan Axial Vertical

4 Kesesuaian pada Struktur Lebih sesuai Kurang seuai Axial Vertical

5 Penyesuaian Ukuran Dapat disesuaikan Tidak dapat disesuaikan Axial Vertical

Perubahan Struktur : Adalah pekerjaan yang dilakukan pada struktur untuk menyesuaikan dengan tipe pompa pengganti

Perubahan Elektrikal : Adalah pekerjaan yang dilakukan pada sistem kelistrikan akibat adanya penggantian pompa

Perlengkapan lain : Adalah pekerjaan yang dilakukan pada Perlengkapan pengoperasian akibat adanya penggantian pompa

Kesesuaian Struktur : Adalah tingka kecocokan dari kondisi disain tipe pompa terhadap struktur bangunan eksisting

Penyesuaian ukuran : Arti penyesuaian disini adalah memungkinkan atau tidaknya unit pompa yang dipesan dapat

dibuat sesuai dengan ukuran Existing sehingga mampu mengurang perubahan-perubahan lainnya.

Perbandingan Kesesuaian Jenis pompa terhadap bangunan eksisting dan perubahan lain yang mengikuti telah merujuk pada

Pompa dengan tipe Axial Vertical

Jo
REKOMENDASI

4.6 STRUKTUR BANGUNAN RUMAH POMPA

Seperti pada penjelasan sebelumnya bahwa Stasiun Rumah pompa banjir Ancol saat ini Mencapai Usia 30 Tahun sejak awal

Pembangunan dengan demikian akan menjadi penting untuk memperhatikan Kondisi baik secara fisik maupun secara analisis

akan kemampuan bangunan tersebut terhadap perubahan unit pompa yang akan dipasang.

Direkomendasikan untuk melakukan penelitian secara cermat dan analisa-analisa yang dapat dijadikan pedoman kangkah kerja

Sehingga didapatkan suatu metode dan rincian biaya untuk pekerjaan perkuatan bangunan tersebut.

Diupayakan dari sisi pekerjaan sipil,mekanikal dan elrktrikal untuk saling mendekati dengan penyesuaian-penyesuaian agar

Dapat menekan anggaran biaya untuk Rehabilitasi Rumah pompa banjir Ancol.

4.7 UKURAN DAN BERAT POMPA

Ukuran dan berat unit pompa pennganti direkomendasikan agar sedapat mungkin tidak jauh berubah dari pompa awal oleh

Karena itu akan menjadi mungkin bila jenis dan tipe pompa pengganti yang serupa namun dengan Nilai Head yang berbeda.

4.8 KOMPONEN PENDUKUNG UNIT POMPA

Komponen pendukung Unit Pompa Sedapat mungkin dilengkapi atau memang sudah menjadi satu kesatuan dengan pompa itu

Sendiri, Karena jika hal tersebut terpisah akan terjadi penambahan biaya dalam pelaksanaan pekerjaannya nanti.

Komponen - komponen pendukung itu Antara lain:

- Pipa Hisap/Pipa Kolom yang dalam unit pompa Axial submersible Komponen ini terpisah sedangkan untuk jenis Axial vertical

Pipa Hisap/Pipa Kolom menjadi satu kesatuan dan merupakan badan pompa.

- Elbow yang dalam unit pompa Axial submersible Komponen ini juga terpisah sedangkan untuk jenis Axial vertical

Elbow menjadi satu kesatuan dan merupakan badan pompa.

- Komponen lainnya adalah Overhead crane, pertimbangan yang dimaksud disini adalah komponen per unit pompa yang terbesar

Atau terberat hendaknya tidak melampaui kapasitas crane eksisting yang sudah ada sehingga tidak perlu menggantinya juga.

4.9 SISTEM KELISTRIKAN

Sama seperti pekerjaan struktur , Perubahan pada Sistem kelistrikan yang ada karena penyesuaian terhadap unit pompa-pompa

Yang baru diupayakan sedapat mugkin tidak Banyak mengalami penggantian.

4.10 BIAYA PENGGANTIAN

Biaya penggantian Unit pompa baru berikut seluruh pekerjaan yang menyertainya direkomendasikan untuk serendah mungkin

Dan seefisien mungkin, tapi juga tidak mengabaikan fungsi,Kualitas dan kemampuan unit pompa-pompa pengganti.

Jo
REKOMENDASI

4.11 WAKTU PELAKSANAAN PEKERJAAN

Mengingat waktu pelaksanaan yang cukup singkat yaitu ±1 tahun. Maka dengan ini direkomendasikan untuk pengadaan unit

Pompa pengganti dan perlengkapan lain yang dipesan dan memerlukan waktu akan menjadi lebih tepat jika unit dan perlengkapan

tersebut adalah produksi dalam negri atau setidaknya sudah tersedia didalam negri. Setidaknya hal itu dapat memotong waktu

pengiriman dan proses andministrasi .

4.12 TINGKAT KANDUNGAN DALAM NEGRI (TKDN)

Berdasarkan peraturan presiden no. 16 Tahun 2018, dan banyaknya perusahaan diindonesia yang sudah dianggap mampu

dari sisi teknologi maka dengan ini direkomendasikan untuk pemesanan Unit pompa-pompa pengganti diutamakan berasal dari

produksi dalam negri dengan tingkat kandungan komponennya antara 45 - 55% terhadap keseluruhan Unit.

4.13 KETERSEDIAAN KOMPONEN POMPA

Ketersediaan Komponen Pompa ini akan lebih dapat terpenuhi jika rekomendasi Point pada 4.12 dilakukan

4.14 BIAYA PERAWATAN DAN PERBAIKAN POMPA

Dari pemilihan jenis dan tipe unit pompa yang dipilih akan menentukan biaya perawatan dan perbaikan, karena itu rekomendasi

Untuk memilih tipe Pompa Axial Vertical harus dilakukan untuk memenuhi ketentuan ini.

4.15 KEMUDAHAN PENGOPERASIAN

Kemudahan pengoperasian termasuk menjadi hal yang penting mengingat keterbatasan Jumlah dan Sumberdaya Manusia

(SDM) yang terbatas, Rekomendasi Khusus untuk hal ini adalah Memilih tipe dan jenis pompa pengganti yang sama dengan tipe

dan jenis pompa elsisting agar para operator tidak terlalu sulit untuk menerima perubahan dalam prosedur pengoperasian pompa

4.16 RANGKUMAN

Rangkuman Rekomendasi adalah :

3 3
1 Kapasitas Rumah Pompa Ancol Dikebalikan Menjadi 15m /Detik dengan Varian unit kapasitas 3 x 5m /detik

3
2 Kapasitas Per Unit Pompa adalah 5m /detik

3 Jenis pompa pengganti Tetap Axial flow dengan Tipe Axial Vertical

4 Head Pompa Menjadi 8.5 - 9.0 Meter - (analisa sementara)

5 Produksi dalam negri dengan TKDN 45-55% dari keseluruhan Unit pompa dan produsen pompa yang mempunyai

workshop dan sarana pengetesan sesuai dengan Kapasitas pompa yang dipesan

Jo