KALIBRASI HEATER BAREL

CCV LINE MAILLEFER


EXTRUDER I
NO. ZONE HMI KALIBRASI
1 W4102 ZONE 1 100°C 102
2 W4202 ZONE 2 100°C 102
3 W4302 ZONE 3 111°C 112
4 W4402 ZONE 4 115°C 116
5 W4802 H1 115°C 112
6 W4902 H2 115°C 112
7 5002 H3 120°C 116

EXTRUDER II
NO. ZONE HMI KALIBRASI
1 W4102 ZONE 1 125°C 125
2 W4202 120°C 116
3 W4302 121°C 120
4 W4402 124°C 120
5 W4502 ZONE 5 125°C 121
6 W4802 ZONE 8 125°C H1 113
7 W4902 ZONE 9 125°C H2 115
8 W5002 ZONE 10 125°C H3 112
9 W5102
10 W5202 ZONE 12 112°C H5 100
11 W5302 ZONE 13 119°C H6 105
12 W2701 120°C 107
W2702 122°C 109
13
W2703 123°C 111

EXTRUDER III
NO. ZONE HMI KALIBRASI
1 W4102 ZONE 1 100°C 102
2 W4202 ZONE 2 100°C 104
3 W4302 ZONE 3 110°C 111
4 W4402 ZONE 4 115°C 115
5 W4802 115°C H1 116
6 W4902 115°C H2 117
7 W4002 120°C H3 115

Keterangan :
Hasil pengukuran di ambil dari Range ter atas.
No Setting HMI Baca HMI TU H5 H6 Calibrasi

1 124°C → 123°C 125°C 121°C 104.8


Tempering 2

133°C → 128°C 130°C 116°C


3 101.5
140°C → 128°C 130°C 117°C

No Setting HMI Baca HMI TU H5 H6 Calibrasi

1 121°C → 119°C 121°C 120°C 104


Tempering
2 121°C → 120°C 122°C

3 130°C → 128°C 130°C 117°C 101.5

Kesimpulan :
* JUMPER
- Temperatur H5 tidak tercapai
- Ada selisih pembaca tempperatur pada alat kalibrasi dengan HM 1

* PEMAKAIAN 3 UNIT TEMPERING


- Temperatur H5 tetep tidak tercapai ua
- Selisih pembacaan temperatur pada alat kalibrasi dengan HMI

1. Pemakaian tempering 1 dan 3. dengan tempering 1,2 dan 3 pembacaan temperative H5,H6 tetap sama.
2 .Untuk mendapatkan temperature 120°C di H6. tempering di seting 121°C.
3 .H5 tidak tercapai diangka 120°C maksimal.117°C untuk setingan tempering sudah sampai 130°C aktual 128.
sudah tidak dapat naik lagi.
4. Pembacaan H5 , H6. HMI dan alat kalibrasi ada selisih 16°C.
Serang, 13-07-2023
Dibuat oleh :

Agus Subarno