Desain Pipa Dan Pompa Kelompok 2
Desain Pipa Dan Pompa Kelompok 2
POMPA
Kelompok III :
Zulfiandriana
1010017411009
Erda rahmilaila desfitri
1010017411020
Muharfa rahman
Tartila
Fani permadi
= 62,4303 lb/ft3
= 1,6 cp . 2,4191
(Q) = Qp/
= 55,5556 lb/dt/lb/ft3
= 0,8899 ft3/dt
a. Menentukan Ukuran
Pipa
diasumsikan aliran turbulen : NRe > 2100
Diopt = 3,9 .(Q)0,45 . ()
0,13
Dimana :
Diopt : diameter optimum (in)
Q : Laju Alir ( ft3/dt)
: densitas (lb/ft3)
Konversi :
63
m . 3,28 ft/m
=
206,64 ft
20,5
m . 3,28 ft/m
=
67,24 ft
7,981 in . 1 ft / 12 m =
0,6651 ft
Tabel
Suction
IPS 8 in sch 40
Discharge
IPS 8 in sch 40
63 m
206,64 ft
20,5 m
67,24 ft
ID
7,981 in
0,6651 ft
7,981 m
0,6651 ft
0,3474 ft2
0,3474 ft2
POMPA I
Perhitungan Pada Suction
Panjang pipa = 63 in
= 63 . 3,28
=206,64 ft
Le 1 Elbow 900
= 1. 32 . 0,0874 ft
= 2,7968 ft
f = 0,0038
Daya Pompa
Persamaan Bernoully :
(Pa/a) + (g. Za/gc) + (a . Va2/2.gc) + Wp = (Pb/b) +
(g.2b/gc) + (b . Vb2/2gc) + hf
Karena tekanan pada kedua station adalah tekanan 1 atm
sehingga :
Pa = Pb karena fluidanya sama
Asumsi : = 1
Sehingga : Za + (Va2/2 gc ) + Wp = 2b + (Vb2/2gc) + hf
Za
= -63 m = -206,64 ft
Va=
=
Zb
hf =
Za + Wp
= 2b + hf
Daya = Wp . m
= (366,576 . 62,7777)/ 550
= 41,84 hp
POMPA II
Suction
IPS 8 in sch 40
Discharge
IPS 8 in sch 40
3m
9,84 ft
25,5 m
83,64 ft
ID
7,981 in
0,6651 ft
7,981 m
0,6651 ft
0,3474 ft2
0,3474 ft2
Persamaan Bernoully :
(Pa/a) + (g. Za/gc) + (a . Va2/2.gc) + Wp = (Pb/b) +
(g.2b/gc) + (b . Vb2/2gc) + hf
Asumsi : Pa = Pb
Kecepatan di suction diabaikan karena pompa berada dekat
tangki, untuk aliran turbulen = 1
Sehingga persamaan menjadi :
Wp = (g/gc) . 2b + ( Vb2 / 2gc ) + hf
g/gc= 1
Vb = Q/A
= (0,8899 ft2 dt) / ( 0,3474 ft2)
= 2,5616 ft/dt
Wp = 83,64 ft + [ (2,5616 ft/dt)2/ ( 2 . 32,174 ft/dt2 . lbf)]
0,75 Wp= 83,742
Wp = 111,656 lbf ft/lb