Anda di halaman 1dari 2

Kelompok VIII/ Semester Ganjil / 2016-2017

BAB III
SPESIFIKASI PERALATAN PROSES
Heater 1
SPESIFIKASI ALAT
Nama Alat Heater 2 Kode Alat HE-102
Fungsi Menaikkan suhu keluaran rectification column
Jenis Shell and tube heat exchanger
Shell Side Tube Side
Fluida Heavy Organics (>1 cp) Fluida Air (steam)
Laju alir fluida (kg/jam) 43567,93 Laju alir fluida (kg/jam) 10039,824
Temperatur masuk (K) 333,15 Temperatur masuk (K) 323,15
Temperatur keluar (K) 353,15 Temperatur keluar (K) 323,15
Kalor umpan, Qumpan (BTU/hr) 1894816,011
T LMTD Koreksi 32,76
Luas perpindahan panas (A), ft2 996,5069
Clean overall coefficient, Uc (Btu/(hr)(ft2)(oF) 226,98
Design overall coefficient, UD (Btu/(hr)(ft2)(oF) 54,5182
Allowable Corrected
Dirt factor, RD (hr)(ft2)(oF)/Btu 0,003 0,0139
Shell Side Tube Side
Shell ID (in) 23,25 Tube OD (in) 1
Baffle Space, B (in) 5 Tube ID (in) 0,810
Pass 2 Number of tube, Nt 192
Clearance, C (in) 0,25 Tube length, L (ft) 20
Equivalent diameter, de 0,810 BWG 13
Flow area /tube, a (in) 0,515
Surface per lin, a (in) 0,2618
Pitch (square) 1,25
Passes 4
Calculate
Allowable Allowable Calculated
d
Pressure Drop, P (psi) 10 0,6623 Pressure Drop, P (psi) 10 0,2208
Kelompok VIII/ Semester Ganjil / 2016-2017

tin Tin

tout Tout

2-4 Heat Exchanger