Anda di halaman 1dari 32

LAMPIRAN C

HASIL ANTARA

C.1. Kalibrasi Piknometer

Tabel C.1. Perhitungan Volume Piknometer Sebenarnya Hari Pertama


Massa piknometer kosong (g) 16.2560
Massa piknometer + aquadest (g) 41.7958
Massa aquadest (g) 25.5398
Densitas Aquadest (g/mL) 0.9968
Volume Piknometer (mL) 25.6215

Tabel C.2. Perhitungan Volume Piknometer Sebenarnya Hari Kedua


Massa piknometer kosong (g) 16.2560
Massa piknometer + aquadest (g) 41.7958
Massa aquadest (g) 25.5398
Densitas Aquadest (g/mL) 0.9966
Volume Piknometer (mL) 25.6271

C.2 Penentuan Densitas Partikel

Tabel C.3. Perhitungan Densitas Partikel Hari Pertama


Ukuran partikel
Keterangan
150-200 200-250
piknometer + partikel (g) 29.4209 29.2011
piknometer + partikel + Aquadest (g) 46.1765 43.8799
Massa partikel (g) 13.1649 12.9451
Massa Aquadest (g) 16.7556 14.6788
Volume Aquadest (mL) 16.8092 14.7258
Volume Partikel (mL) 8.8123 10.8958
Densitas Partikel (kg/m3) 1493.9214 1188.0863

Tabel C.4. Perhitungan Densitas Partikel Hari Pertama


Ukuran partikel
Keterangan
150-200 200-250
piknometer + partikel (g) 29.4209 29.2011
piknometer + partikel + Aquadest (g) 46.1765 43.8799
Massa partikel (g) 13.1649 12.9451
Massa Aquadest (g) 16.7556 14.6788
Volume Aquadest (mL) 16.8092 14.7258
Volume Partikel (mL) 8.8178 10.9013
Densitas Partikel (kg/m3) 1492.9849 1187.4839
C.3 Kalibrasi Rotameter Gas
Tabel C.5. Kalibrasi Rotameter Gas
Volume Waktu (s) Rata-rata Q( m3/s)
Skala
(m3) 1 2 3 (s) X 10-6
0 0 0 0 0 0 0.00
4 0.003 64 65 63 64.00 46.87
6 0.003 38 38 39 38.33 78.26
8 0.003 32 33 32 32.33 92.78
10 0.003 30 31 30 30.33 98.90
12 0.003 29 28 29 28.67 104.65
14 0.003 28 28 27 27.67 108.43
16 0.003 26 26 26 26.00 115.38
18 0.003 24 25 24 24.33 123.28
20 0.003 23 23 24 23.33 128.57
22 0.003 22 22 22 22.00 136.36

120
y = 5.7083x + 28.065
100 R² = 0.8616

80
Q(m3/s)

60

40

20

0
Skala
0 5 10 15 20

Gambar C.1. Kurva Kalibrasi Rotameter Gas

C.4 Kalibrasi Rotameter Cair


Tabel C.6. Kalibrasi Rotameter Cair

Volume Waktu (s) Rata-rata Q( m3/s)


Skala
(m3) 1 2 3 (s) X 10-6
0 0 0 0 0 0 0.00
0.2 0.0001 32.72 32.5 32.7 64.00 46.87
0.4 0.0001 13.87 13.08 12.91 38.33 78.26
0.6 0.0001 11.52 11.12 10.92 32.33 92.78
0.8 0.0001 6.48 6.72 6.02 30.33 98.90
1 0.0001 5.94 5.56 6.01 28.67 104.65
1.2 0.0001 5.19 5.02 4.96 27.67 108.43
1.4 0.0001 4.39 4.21 4.02 26.00 115.38
1.6 0.0001 3.9 3.79 3.89 24.33 123.28
1.8 0.0001 2.27 2.2 2.28 23.33 128.57
2 0.0001 1.99 1.8 1.79 22.00 136.36
50
y = 23.787x - 3.793
R² = 0.8959
40

Q(m3/s)
30

20

10

0
0 0.5 1 1.5 2 2.5
Skala

Gambar C.2. Kurva Kalibrasi Rotameter Cair

C.5 Penentuan ΔP Berdasarkan Percobaan


C.5.1 Penentuan ΔP Berdasarkan Percobaan Fluida Gas
Tabel C.7 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc dan
Tinggi Unggun Awal 5 cm

ρ aquadest ρ gas ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (kg/m3) (Pa) (m3/s) (m/s)
0 996.81 1.1817 9.80 0.0000 0.0000 28.0650 14300.6369
4 996.81 1.1817 9.80 0.0100 97.5716 50.8982 25935.3885
6 996.81 1.1817 9.80 0.0150 146.3574 62.3148 31752.7643
8 996.81 1.1817 9.80 0.0180 175.6288 73.7314 37570.1401
10 996.81 1.1817 9.80 0.0380 370.7720 85.1480 43387.5159
12 996.81 1.1817 9.80 0.0450 439.0721 96.5646 49204.8917
14 996.81 1.1817 9.80 0.0400 390.2863 107.9812 55022.2675
16 996.81 1.1817 9.80 0.0360 351.2577 119.3978 60839.6433
18 996.81 1.1817 9.80 0.0360 351.2577 130.8144 66657.0191
20 996.81 1.1817 9.80 0.0360 351.2577 142.2310 72474.3949
22 996.81 1.1817 9.80 0.0360 351.2577 153.6476 78291.7707
20 996.81 1.1817 9.80 0.0360 351.2577 142.2310 72474.3949
18 996.81 1.1817 9.80 0.0360 351.2577 130.8144 66657.0191
16 996.81 1.1817 9.80 0.0360 351.2577 119.3978 60839.6433
14 996.81 1.1817 9.80 0.0360 351.2577 107.9812 55022.2675
12 996.81 1.1817 9.80 0.0370 361.0148 96.5646 49204.8917
10 996.81 1.1817 9.80 0.0300 292.7147 85.1480 43387.5159
8 996.81 1.1817 9.80 0.0300 292.7147 73.7314 37570.1401
6 996.81 1.1817 9.80 0.0240 234.1718 62.3148 31752.7643
4 996.81 1.1817 9.80 0.0120 117.0859 50.8982 25935.3885
Tabel C.8 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan UkuranPartikel 150-200 mc dan
Tinggi Unggun Awal 7 cm

ρ aquadest ρ gas ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (kg/m3) (Pa) (m3/s) (m/s)
0 996.81 1.1817 9.80 0.0000 0.0000 28.0650 14300.6369
4 996.81 1.1817 9.80 0.0150 146.3574 50.8982 25935.3885
6 996.81 1.1817 9.80 0.0210 204.9003 62.3148 31752.7643
8 996.81 1.1817 9.80 0.0270 263.4432 73.7314 37570.1401
10 996.81 1.1817 9.80 0.0400 390.2863 85.1480 43387.5159
12 996.81 1.1817 9.80 0.0480 468.3436 96.5646 49204.8917
14 996.81 1.1817 9.80 0.0550 536.6437 107.9812 55022.2675
16 996.81 1.1817 9.80 0.0620 604.9438 119.3978 60839.6433
18 996.81 1.1817 9.80 0.0550 536.6437 130.8144 66657.0191
20 996.81 1.1817 9.80 0.0550 536.6437 142.2310 72474.3949
22 996.81 1.1817 9.80 0.0550 536.6437 153.6476 78291.7707
20 996.81 1.1817 9.80 0.0550 536.6437 142.2310 72474.3949
18 996.81 1.1817 9.80 0.0550 536.6437 130.8144 66657.0191
16 996.81 1.1817 9.80 0.0550 536.6437 119.3978 60839.6433
14 996.81 1.1817 9.80 0.0550 536.6437 107.9812 55022.2675
12 996.81 1.1817 9.80 0.0490 478.1007 96.5646 49204.8917
10 996.81 1.1817 9.80 0.0380 370.7720 85.1480 43387.5159
8 996.81 1.1817 9.80 0.0340 331.7433 73.7314 37570.1401
6 996.81 1.1817 9.80 0.0250 243.9289 62.3148 31752.7643
4 996.81 1.1817 9.80 0.0150 146.3574 50.8982 25935.3885

Tabel C.9 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc dan
Tinggi Unggun Awal 8 cm

ρ aquadest ρ gas ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (kg/m3) (pa) (m3/s) (m/s)
0 996.81 1.1817 9.80 0.0000 0.0000 28.0650 14300.6369
4 996.81 1.1817 9.80 0.0150 146.3574 50.8982 25935.3885
6 996.81 1.1817 9.80 0.0220 214.6575 62.3148 31752.7643
8 996.81 1.1817 9.80 0.0340 331.7433 73.7314 37570.1401
10 996.81 1.1817 9.80 0.0470 458.5864 85.1480 43387.5159
12 996.81 1.1817 9.80 0.0570 556.1580 96.5646 49204.8917
14 996.81 1.1817 9.80 0.0650 634.2152 107.9812 55022.2675
16 996.81 1.1817 9.80 0.0720 702.5153 119.3978 60839.6433
18 996.81 1.1817 9.80 0.0650 634.2152 130.8144 66657.0191
20 996.81 1.1817 9.80 0.0650 634.2152 142.2310 72474.3949
22 996.81 1.1817 9.80 0.0650 634.2152 153.6476 78291.7707
20 996.81 1.1817 9.80 0.0650 634.2152 142.2310 72474.3949
18 996.81 1.1817 9.80 0.0650 634.2152 130.8144 66657.0191
16 996.81 1.1817 9.80 0.0650 634.2152 119.3978 60839.6433
14 996.81 1.1817 9.80 0.0600 585.4294 107.9812 55022.2675
12 996.81 1.1817 9.80 0.0320 312.2290 96.5646 49204.8917
10 996.81 1.1817 9.80 0.0440 429.3149 85.1480 43387.5159
8 996.81 1.1817 9.80 0.0330 321.9862 73.7314 37570.1401
6 996.81 1.1817 9.80 0.0230 224.4146 62.3148 31752.7643
4 996.81 1.1817 9.80 0.0150 146.3574 50.8982 25935.3885
Tabel C.10 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 5 cm

ρ aquadest ρ gas ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (kg/m3) (pa) (m3/s) (m/s)
0 996.81 1.1817 9.80 0.0000 0.0000 28.0650 14300.6369
4 996.81 1.1817 9.80 0.0080 78.0573 50.8982 25935.3885
6 996.81 1.1817 9.80 0.0100 97.5716 62.3148 31752.7643
8 996.81 1.1817 9.80 0.0130 126.8430 73.7314 37570.1401
10 996.81 1.1817 9.80 0.0150 146.3574 85.1480 43387.5159
12 996.81 1.1817 9.80 0.0190 185.3860 96.5646 49204.8917
14 996.81 1.1817 9.80 0.0230 224.4146 107.9812 55022.2675
16 996.81 1.1817 9.80 0.0280 273.2004 119.3978 60839.6433
18 996.81 1.1817 9.80 0.0300 292.7147 130.8144 66657.0191
20 996.81 1.1817 9.80 0.0340 331.7433 142.2310 72474.3949
22 996.81 1.1817 9.80 0.0280 273.2004 153.6476 78291.7707
20 996.81 1.1817 9.80 0.0290 282.9576 142.2310 72474.3949
18 996.81 1.1817 9.80 0.0260 253.6861 130.8144 66657.0191
16 996.81 1.1817 9.80 0.0270 263.4432 119.3978 60839.6433
14 996.81 1.1817 9.80 0.0270 263.4432 107.9812 55022.2675
12 996.81 1.1817 9.80 0.0260 253.6861 96.5646 49204.8917
10 996.81 1.1817 9.80 0.0220 214.6575 85.1480 43387.5159
8 996.81 1.1817 9.80 0.0200 195.1431 73.7314 37570.1401
6 996.81 1.1817 9.80 0.0140 136.6002 62.3148 31752.7643
4 996.81 1.1817 9.80 0.0120 117.0859 50.8982 25935.3885

Tabel C.11 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 7 cm

ρ aquadest ρ gas ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (kg/m3) (pa) (m3/s) (m/s)
0 996.81 1.1817 9.80 0.0000 0.0000 28.0650 14300.6369
4 996.81 1.1817 9.80 0.0100 97.5716 50.8982 25935.3885
6 996.81 1.1817 9.80 0.0150 146.3574 62.3148 31752.7643
8 996.81 1.1817 9.80 0.0200 195.1431 73.7314 37570.1401
10 996.81 1.1817 9.80 0.0250 243.9289 85.1480 43387.5159
12 996.81 1.1817 9.80 0.0280 273.2004 96.5646 49204.8917
14 996.81 1.1817 9.80 0.0350 341.5005 107.9812 55022.2675
16 996.81 1.1817 9.80 0.0410 400.0435 119.3978 60839.6433
18 996.81 1.1817 9.80 0.0440 429.3149 130.8144 66657.0191
20 996.81 1.1817 9.80 0.0500 487.8579 142.2310 72474.3949
22 996.81 1.1817 9.80 0.0500 487.8579 153.6476 78291.7707
20 996.81 1.1817 9.80 0.0450 439.0721 142.2310 72474.3949
18 996.81 1.1817 9.80 0.0420 409.8006 130.8144 66657.0191
16 996.81 1.1817 9.80 0.0390 380.5291 119.3978 60839.6433
14 996.81 1.1817 9.80 0.0320 312.2290 107.9812 55022.2675
12 996.81 1.1817 9.80 0.0290 282.9576 96.5646 49204.8917
10 996.81 1.1817 9.80 0.0240 234.1718 85.1480 43387.5159
8 996.81 1.1817 9.80 0.0200 195.1431 73.7314 37570.1401
6 996.81 1.1817 9.80 0.0170 165.8717 62.3148 31752.7643
4 996.81 1.1817 9.80 0.0100 97.5716 50.8982 25935.3885
Tabel C.12 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 8 cm

ρ aquadest ρ gas ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (kg/m3) (Pa) (m3/s) (m/s)
0 996.81 1.1817 9.80 0.0000 0.0000 28.0650 14300.6369
4 996.81 1.1817 9.80 0.0120 117.0859 50.8982 25935.3885
6 996.81 1.1817 9.80 0.0140 136.6002 62.3148 31752.7643
8 996.81 1.1817 9.80 0.0220 214.6575 73.7314 37570.1401
10 996.81 1.1817 9.80 0.0290 282.9576 85.1480 43387.5159
12 996.81 1.1817 9.80 0.0310 302.4719 96.5646 49204.8917
14 996.81 1.1817 9.80 0.0390 380.5291 107.9812 55022.2675
16 996.81 1.1817 9.80 0.0470 458.5864 119.3978 60839.6433
18 996.81 1.1817 9.80 0.0550 536.6437 130.8144 66657.0191
20 996.81 1.1817 9.80 0.0600 585.4294 142.2310 72474.3949
22 996.81 1.1817 9.80 0.0660 643.9724 153.6476 78291.7707
20 996.81 1.1817 9.80 0.0630 614.7009 142.2310 72474.3949
18 996.81 1.1817 9.80 0.0540 526.8865 130.8144 66657.0191
16 996.81 1.1817 9.80 0.0480 468.3436 119.3978 60839.6433
14 996.81 1.1817 9.80 0.0400 390.2863 107.9812 55022.2675
12 996.81 1.1817 9.80 0.0370 361.0148 96.5646 49204.8917
10 996.81 1.1817 9.80 0.0290 282.9576 85.1480 43387.5159
8 996.81 1.1817 9.80 0.0240 234.1718 73.7314 37570.1401
6 996.81 1.1817 9.80 0.0170 165.8717 62.3148 31752.7643
4 996.81 1.1817 9.80 0.0120 117.0859 50.8982 25935.3885

C.5.2 Penentuan ΔP Berdasarkan Percobaan Fluida Cair


Tabel C.13 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 3 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.81 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.81 9.80 0.0120 1474.0396 0.9644 491.4140
0.4 996.81 9.80 0.0210 2579.5692 5.7218 2915.5669
0.6 996.81 9.80 0.0250 3070.9158 10.4792 5339.7197
0.8 996.81 9.80 0.0300 3685.0989 15.2366 7763.8726
1 996.81 9.80 0.0280 3439.4256 19.9940 10188.0255
1.2 996.81 9.80 0.0300 3685.0989 24.7514 12612.1783
1.4 996.81 9.80 0.0350 4299.2821 29.5088 15036.3312
1.6 996.81 9.80 0.0350 4299.2821 34.2662 17460.4841
1.8 996.81 9.80 0.0400 4913.4652 39.0236 19884.6369
2 996.81 9.80 0.0450 5527.6484 43.7810 22308.7898
1.8 996.81 9.80 0.0350 4299.2821 39.0236 19884.6369
1.6 996.81 9.80 0.0350 4299.2821 34.2662 17460.4841
1.4 996.81 9.80 0.0350 4299.2821 29.5088 15036.3312
1.2 996.81 9.80 0.0350 4299.2821 24.7514 12612.1783
1 996.81 9.80 0.0310 3807.9355 19.9940 10188.0255
0.8 996.81 9.80 0.0260 3193.7524 15.2366 7763.8726
0.6 996.81 9.80 0.0200 2456.7326 10.4792 5339.7197
0.4 996.81 9.80 0.0170 2088.2227 5.7218 2915.5669
0.2 996.81 9.80 0.0100 1228.3663 0.9644 491.4140
Tabel C.14 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 6 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.81 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.81 9.80 0.0120 1474.0396 0.9644 491.4140
0.4 996.81 9.80 0.0210 2579.5692 5.7218 2915.5669
0.6 996.81 9.80 0.0240 2948.0791 10.4792 5339.7197
0.8 996.81 9.80 0.0250 3070.9158 15.2366 7763.8726
1 996.81 9.80 0.0250 3070.9158 19.9940 10188.0255
1.2 996.81 9.80 0.0320 3930.7722 24.7514 12612.1783
1.4 996.81 9.80 0.0370 4544.9553 29.5088 15036.3312
1.6 996.81 9.80 0.0420 5159.1385 34.2662 17460.4841
1.8 996.81 9.80 0.0800 9826.9304 39.0236 19884.6369
2 996.81 9.80 0.0850 10441.1136 43.7810 22308.7898
1.8 996.81 9.80 0.0840 10318.2769 39.0236 19884.6369
1.6 996.81 9.80 0.0800 9826.9304 34.2662 17460.4841
1.4 996.81 9.80 0.0700 8598.5641 29.5088 15036.3312
1.2 996.81 9.80 0.0700 8598.5641 24.7514 12612.1783
1 996.81 9.80 0.0700 8598.5641 19.9940 10188.0255
0.8 996.81 9.80 0.0600 7370.1978 15.2366 7763.8726
0.6 996.81 9.80 0.0420 5159.1385 10.4792 5339.7197
0.4 996.81 9.80 0.0300 3685.0989 5.7218 2915.5669
0.2 996.81 9.80 0.0200 2456.7326 0.9644 491.4140

Tabel C.15 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 7 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.5950 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.5950 9.80 0.0280 3439.4846 0.9644 491.4140
0.4 996.5950 9.80 0.0300 3685.1621 5.7218 2915.5669
0.6 996.5950 9.80 0.0300 3685.1621 10.4792 5339.7197
0.8 996.5950 9.80 0.0350 4299.3558 15.2366 7763.8726
1 996.5950 9.80 0.0350 4299.3558 19.9940 10188.0255
1.2 996.5950 9.80 0.0350 4299.3558 24.7514 12612.1783
1.4 996.5950 9.80 0.0350 4299.3558 29.5088 15036.3312
1.2 996.5950 9.80 0.0350 4299.3558 24.7514 12612.1783
1 996.5950 9.80 0.0300 3685.1621 19.9940 10188.0255
0.8 996.5950 9.80 0.0250 3070.9684 15.2366 7763.8726
0.6 996.5950 9.80 0.0220 2702.4522 10.4792 5339.7197
0.4 996.5950 9.80 0.0220 2702.4522 5.7218 2915.5669
0.2 996.5950 9.80 0.0220 2702.4522 0.9644 491.4140
Tabel C.16 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 9 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.5950 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.5950 9.80 0.0100 1228.3874 4.7574 2424.1529
0.4 996.5950 9.80 0.0250 3070.9684 9.5148 4848.3057
0.6 996.5950 9.80 0.0300 3685.1621 14.2722 7272.4586
0.8 996.5950 9.80 0.0500 6141.9369 19.0296 9696.6115
1 996.5950 9.80 0.0550 6756.1305 23.7870 12120.7643
1.2 996.5950 9.80 0.0650 7984.5179 28.5444 14544.9172
1.4 996.5950 9.80 0.0700 8598.7116 33.3018 16969.0701
1.6 996.5950 9.80 0.0800 9827.0990 38.0592 19393.2229
1.8 996.5950 9.80 0.0950 11669.6800 42.8166 21817.3758
2 996.5950 9.80 0.1100 13512.2611 47.5740 24241.5287
1.8 996.5950 9.80 0.1150 14126.4548 42.8166 21817.3758
1.6 996.5950 9.80 0.1000 12283.8737 38.0592 19393.2229
1.4 996.5950 9.80 0.0950 11669.6800 33.3018 16969.0701
1.2 996.5950 9.80 0.0800 9827.0990 28.5444 14544.9172
1 996.5950 9.80 0.0700 8598.7116 23.7870 12120.7643
0.8 996.5950 9.80 0.0550 6756.1305 19.0296 9696.6115
0.6 996.5950 9.80 0.0450 5527.7432 14.2722 7272.4586
0.4 996.5950 9.80 0.0300 3685.1621 9.5148 4848.3057
0.2 996.5950 9.80 0.0200 2456.7747 4.7574 2424.1529

Tabel C.17 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 3 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.5950 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.5950 9.80 0.0450 5527.7432 0.9644 491.4140
0.4 996.5950 9.80 0.0550 6756.1305 5.7218 2915.5669
0.6 996.5950 9.80 0.0600 7370.3242 10.4792 5339.7197
0.8 996.5950 9.80 0.0650 7984.5179 15.2366 7763.8726
1 996.5950 9.80 0.0700 8598.7116 19.9940 10188.0255
1.2 996.5950 9.80 0.0700 8598.7116 24.7514 12612.1783
1.4 996.5950 9.80 0.0700 8598.7116 29.5088 15036.3312
1.2 996.5950 9.80 0.0700 8598.7116 24.7514 12612.1783
1 996.5950 9.80 0.0700 8598.7116 19.9940 10188.0255
0.8 996.5950 9.80 0.0650 7984.5179 15.2366 7763.8726
0.6 996.5950 9.80 0.0630 7738.8404 10.4792 5339.7197
0.4 996.5950 9.80 0.0560 6878.9693 5.7218 2915.5669
0.2 996.5950 9.80 0.0500 6141.9369 0.9644 491.4140
Tabel C.18 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 6 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.5950 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.5950 9.80 0.0100 5527.7432 0.9644 491.4140
0.4 996.5950 9.80 0.0250 6756.1305 5.7218 2915.5669
0.6 996.5950 9.80 0.0300 7984.5179 10.4792 5339.7197
0.8 996.5950 9.80 0.0500 7984.5179 15.2366 7763.8726
1 996.5950 9.80 0.0550 7984.5179 19.9940 10188.0255
0.8 996.5950 9.80 0.0650 7984.5179 15.2366 7763.8726
0.6 996.5950 9.80 0.0700 7370.3242 10.4792 5339.7197
0.4 996.5950 9.80 0.0800 6264.7756 5.7218 2915.5669
0.2 996.5950 9.80 0.0950 6019.0981 0.9644 491.4140

Tabel C.19 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 7 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.5950 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.5950 9.80 0.0450 5527.7432 0.9644 491.4140
0.4 996.5950 9.80 0.0550 6756.1305 5.7218 2915.5669
0.6 996.5950 9.80 0.0600 7370.3242 10.4792 5339.7197
0.8 996.5950 9.80 0.0650 7984.5179 15.2366 7763.8726
1 996.5950 9.80 0.0700 8598.7116 19.9940 10188.0255
1.2 996.5950 9.80 0.0750 9212.9053 24.7514 12612.1783
1.4 996.5950 9.80 0.0900 11055.4863 29.5088 15036.3312
1.6 996.5950 9.80 0.1000 12283.8737 34.2662 17460.4841
1.8 996.5950 9.80 0.1000 12283.8737 39.0236 19884.6369
2 996.5950 9.80 0.1000 12283.8737 43.7810 22308.7898
1.8 996.5950 9.80 0.1000 12283.8737 39.0236 19884.6369
1.6 996.5950 9.80 0.0980 12038.1962 34.2662 17460.4841
1.4 996.5950 9.80 0.0850 10441.2926 29.5088 15036.3312
1.2 996.5950 9.80 0.0840 10318.4539 24.7514 12612.1783
1 996.5950 9.80 0.0800 9827.0990 19.9940 10188.0255
0.8 996.5950 9.80 0.0800 9827.0990 15.2366 7763.8726
0.6 996.5950 9.80 0.0650 7984.5179 10.4792 5339.7197
0.4 996.5950 9.80 0.0600 7370.3242 5.7218 2915.5669
0.2 996.5950 9.80 0.0500 6141.9369 0.9644 491.4140
Tabel C.20 Data Penentuan ΔP berdasarkan Percobaan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 9 cm

ρ aquadest ΔP percobaan Q X 10-6 U X 10-6


Skala g (m/s2) Δh (m)
(kg/m3) (Pa) (m3/s) (m/s)
0 996.5950 9.80 0.0000 0.0000 0.0000 0.0000
0.2 996.5950 9.80 0.0500 6141.9369 0.9644 491.4140
0.4 996.5950 9.80 0.0650 7984.5179 5.7218 2915.5669
0.6 996.5950 9.80 0.0700 8598.7116 10.4792 5339.7197
0.8 996.5950 9.80 0.0700 8598.7116 15.2366 7763.8726
1 996.5950 9.80 0.0700 8598.7116 19.9940 10188.0255
1.2 996.5950 9.80 0.0700 8598.7116 24.7514 12612.1783
1 996.5950 9.80 0.0700 8598.7116 19.9940 10188.0255
0.8 996.5950 9.80 0.0680 8353.0341 15.2366 7763.8726
0.6 996.5950 9.80 0.0650 7984.5179 10.4792 5339.7197
0.4 996.5950 9.80 0.0600 7370.3242 5.7218 2915.5669
0.2 996.5950 9.80 0.0500 6141.9369 0.9644 491.4140

C.6 Penentuan ΔP Berdasarkan Perhitungan


C.6.1 Penentuan ΔP Berdasarkan Perhitungan Fluida Gas
Tabel C.21 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 5 cm
Vp
U X 10-6 Vu X105 ρgas μgas (Pa.s)
L (m) X105 Dp (m) ε ΔP (Pa)
(m/s) (m3) (kg/m3) (x105)
(m3)
0.0500 14300.6369 9.8125 0.3519 127.9467
0.0500 25935.3885 9.8125 0.3519 233.4771
0.0500 31752.7643 9.8125 0.3519 286.7252
0.0500 37570.1401 9.8125 0.3519 340.2951
0.0500 43387.5159 9.8125 0.3519 394.1870
0.0500 49204.8917 9.8125 0.3519 448.4008
0.0510 55022.2675 10.00875 0.3646 444.0240
0.0510 60839.6433 10.00875 0.3646 492.5376
0.0520 66657.0191 10.205 0.3769 481.8960
0.0540 72474.3949 10.5975 0.3999 425.3446
6.3591 0.000175 1.1817 1.5581
0.0550 78291.7707 10.79375 0.4109 418.6044
0.0540 72474.3949 10.5975 0.3999 425.3446
0.0520 66657.0191 10.205 0.3769 481.8960
0.0520 60839.6433 10.205 0.3769 438.3714
0.0500 55022.2675 9.8125 0.3519 502.9365
0.0500 49204.8917 9.8125 0.3519 448.4008
0.0500 43387.5159 9.8125 0.3519 394.1870
0.0500 37570.1401 9.8125 0.3519 340.2951
0.0500 31752.7643 9.8125 0.3519 286.7252
0.0500 25935.3885 9.8125 0.3519 233.4771
Tabel C.22 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 7 cm
Vp
U X 10-6 Vu X105 ρgas μgas (Pa.s)
L (m) X105 Dp (m) ε ΔP (Pa)
(m/s) (m3) (kg/m3) (x105)
(m3)
0.0700 14300.6369 13.7375 0.3958 109.6418
0.0700 25935.3885 13.7375 0.3958 200.3255
0.0700 31752.7643 13.7375 0.3958 246.1658
0.0700 37570.1401 13.7375 0.3958 292.3382
0.0700 43387.5159 13.7375 0.3958 338.8429
0.0700 49204.8917 13.7375 0.3958 385.6797
0.0710 55022.2675 13.93375 0.4043 400.8642
0.0720 60839.6433 14.13 0.4126 413.4265
0.0730 66657.0191 14.32625 0.4206 423.8589
0.0750 72474.3949 14.71875 0.4361 405.4522
8.3003 0.000175 1.1817 1.5581
0.0770 78291.7707 15.11125 0.4507 389.3262
0.0750 72474.3949 14.71875 0.4361 405.4522
0.0740 66657.0191 14.5225 0.4285 396.2120
0.0710 60839.6433 13.93375 0.4043 444.9115
0.0700 55022.2675 13.7375 0.3958 432.8488
0.0700 49204.8917 13.7375 0.3958 385.6797
0.0700 43387.5159 13.7375 0.3958 338.8429
0.0700 37570.1401 13.7375 0.3958 292.3382
0.0700 31752.7643 13.7375 0.3958 246.1658
0.0700 25935.3885 13.7375 0.3958 200.3255
Tabel C.23 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Gas dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 8 cm
Vp
U X 10-6 Vu X105 ρgas μgas (Pa.s)
L (m) X105 Dp (m) ε ΔP (Pa)
(m/s) (m3) (kg/m3) (x105)
(m3)
0.0800 14300.6369 15.7000 0.3903 133.0128

0.0800 25935.3885 15.7000 0.3903 242.9861

0.0800 31752.7643 15.7000 0.3903 298.5637

0.0800 37570.1401 15.7000 0.3903 354.5353

0.0800 43387.5159 15.7000 0.3903 410.9009

0.0800 49204.8917 15.7000 0.3903 467.6604

0.0810 55022.2675 15.8963 0.3978 489.9936

0.0820 60839.6433 16.0925 0.4052 509.0730

0.0840 66657.0191 16.4850 0.4193 494.2638

0.0860 72474.3949 16.8775 0.4328 480.5162


9.5721 0.000175 1.1817 1.5581
0.0880 78291.7707 17.2700 0.4457 467.8638

0.0870 72474.3949 17.0738 0.4394 454.7935

0.0850 66657.0191 16.6813 0.4262 465.9339

0.0810 60839.6433 15.8963 0.3978 543.7824

0.0810 55022.2675 15.8963 0.3978 489.9936

0.0800 49204.8917 15.7000 0.3903 467.6604

0.0800 43387.5159 15.7000 0.3903 410.9009

0.0800 37570.1401 15.7000 0.3903 354.5353

0.0800 31752.7643 15.7000 0.3903 298.5637

0.0800 25935.3885 15.7000 0.3903 242.9861


Tabel C.24 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 5 cm
Vp
U X 10-6 Vu X105 5 ρgas μgas (Pa.s)
L (m) X10 Dp (m) ε ΔP (Pa)
(m/s) (m3) 3 (kg/m3) (x105)
(m )
0.0500 14300.6369 9.8125 0.4253 34.6910
0.0500 25935.3885 9.8125 0.4253 63.5928
0.0500 31752.7643 9.8125 0.4253 78.2718
0.0500 37570.1401 9.8125 0.4253 93.1028
0.0500 43387.5159 9.8125 0.4253 108.0859
0.0500 49204.8917 9.8125 0.4253 123.2210
0.0500 55022.2675 9.8125 0.4253 138.5081
0.0500 60839.6433 9.8125 0.4253 153.9474
0.0500 66657.0191 9.8125 0.4253 169.5386
0.0510 72474.3949 10.00875 0.4366 168.4454
5.6393 0.000225 1.1817 1.5581
0.0600 78291.7707 11.775 0.5211 94.0834
0.0510 72474.3949 10.00875 0.4366 168.4454
0.0500 66657.0191 9.8125 0.4253 169.5386
0.0500 60839.6433 9.8125 0.4253 153.9474
0.0500 55022.2675 9.8125 0.4253 138.5081
0.0500 49204.8917 9.8125 0.4253 123.2210
0.0500 43387.5159 9.8125 0.4253 108.0859
0.0500 37570.1401 9.8125 0.4253 93.1028
0.0500 31752.7643 9.8125 0.4253 78.2718
0.0500 25935.3885 9.8125 0.4253 63.5928
Tabel C.25 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 7 cm
Vp
U X 10-6 Vu X105 ρgas μgas (Pa.s)
L (m) X105 Dp (m) ε ΔP (Pa)
(m/s) (m3) (kg/m3) (x105)
(m3)
0.0700 14300.6369 13.7375 0.5895 9.4208
0.0700 25935.3885 13.7375 0.5895 17.4382
0.0700 31752.7643 13.7375 0.5895 21.5656
0.0700 37570.1401 13.7375 0.5895 25.7722
0.0700 43387.5159 13.7375 0.5895 30.0579
0.0700 49204.8917 13.7375 0.5895 34.4227
0.0700 55022.2675 13.7375 0.5895 38.8667
0.0700 60839.6433 13.7375 0.5895 43.3898
0.0710 66657.0191 13.93375 0.5953 46.0713
0.0710 72474.3949 13.93375 0.5953 50.5755
5.6393 0.000225 1.1817 1.5581
0.0710 78291.7707 13.93375 0.5953 55.1573
0.0710 72474.3949 13.93375 0.5953 50.5755
0.0710 66657.0191 13.93375 0.5953 46.0713
0.0710 60839.6433 13.93375 0.5953 41.6446
0.0700 55022.2675 13.7375 0.5895 38.8667
0.0700 49204.8917 13.7375 0.5895 34.4227
0.0700 43387.5159 13.7375 0.5895 30.0579
0.0700 37570.1401 13.7375 0.5895 25.7722
0.0700 31752.7643 13.7375 0.5895 21.5656
0.0700 25935.3885 13.7375 0.5895 17.4382
Tabel C.26 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Gas dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 8 cm
Vp
U X 10-6 Vu X105 ρgas μgas (Pa.s)
L (m) X105 Dp (m) ε ΔP (Pa)
(m/s) (m3) (kg/m3) (x105)
(m3)
0.0800 14300.6369 15.7000 0.4264 54.8857

0.0800 25935.3885 15.7000 0.4264 100.6168

0.0800 31752.7643 15.7000 0.4264 123.8448

0.0800 37570.1401 15.7000 0.4264 147.3143

0.0800 43387.5159 15.7000 0.4264 171.0255

0.0800 49204.8917 15.7000 0.4264 194.9783

0.0800 55022.2675 15.7000 0.4264 219.1727

0.0800 60839.6433 15.7000 0.4264 243.6086

0.0800 66657.0191 15.7000 0.4264 268.2862

0.0800 72474.3949 15.7000 0.4264 293.2054


9.0061 0.000225 1.1817 1.5581
0.0800 78291.7707 15.7000 0.4264 318.3662

0.0800 72474.3949 15.7000 0.4264 293.2054

0.0800 66657.0191 15.7000 0.4264 268.2862

0.0800 60839.6433 15.7000 0.4264 243.6086

0.0800 55022.2675 15.7000 0.4264 219.1727

0.0800 49204.8917 15.7000 0.4264 194.9783

0.0800 43387.5159 15.7000 0.4264 171.0255

0.0800 37570.1401 15.7000 0.4264 147.3143

0.0800 31752.7643 15.7000 0.4264 123.8448

0.0800 25935.3885 15.7000 0.4264 100.6168


C.6.2 Penentuan ΔP Berdasarkan Perhitungan Fluida Cair
Tabel C.27 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 3 cm

U X 10-6
Vp
ρaquades μaquades ΔP X 106
L (m) 3
Vu (m ) X105 Dp (m) ε (Pa.s)
(m/s) (kg/m3) (x105) (Pa)
(m3)
0.0300 0.0000 0.0059 0.9940 0.0000
0.0600 491.4140 0.0118 0.9970 0.5717
0.0750 2915.5669 0.0147 0.9976 2.7875
0.0900 5339.7197 0.0177 0.9980 4.4159
0.1050 7763.8726 0.0206 0.9983 5.7639
0.1350 10188.0255 0.0265 0.9987 6.3288
0.1700 12612.1783 0.0334 0.9989 6.8270
0.2100 15036.3312 0.0412 0.9991 7.3614
0.2450 17460.4841 0.0481 0.9993 8.1783
0.3000 19884.6369 0.0589 0.9994 8.7993
3.5477 0.000175 996.81 0.0009077
0.3700 22308.7898 0.0726 0.9995 9.4770
0.3400 19884.6369 0.0667 0.9995 8.2599
0.2600 17460.4841 0.0510 0.9993 7.8937
0.2000 15036.3312 0.0393 0.9991 7.6095
0.1870 12612.1783 0.0367 0.9990 6.3594
0.1500 10188.0255 0.0294 0.9988 5.8049
0.1240 7763.8726 0.0243 0.9985 4.9759
0.0950 5339.7197 0.0186 0.9981 4.1982
0.0760 2915.5669 0.0149 0.9976 2.7518
0.0580 491.4140 0.0114 0.9969 0.5915
Tabel C.28 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 6 cm

U X 10-6
Vp
ρaquades μaquades
L (m) Vu (m3) X105 Dp (m) ε (Pa.s) ΔP (Pa)
(m/s) (kg/m3) (x105)
(m3)
0.0600 0.0000 0.0118 0.9970 0.0000
0.1200 491.4140 0.0236 0.9985 0.0008
0.1450 2915.5669 0.0285 0.9988 0.0243
0.1700 5339.7197 0.0334 0.9989 0.0803
0.1950 7763.8726 0.0383 0.9991 0.1688
0.2500 10188.0255 0.0491 0.9993 0.2896
0.2900 12612.1783 0.0569 0.9994 0.4431
0.3500 15036.3312 0.0687 0.9995 0.6289
0.4000 17460.4841 0.0785 0.9995 0.8475
0.4300 19884.6369 0.0844 0.9996 1.0987
3.5477 0.000175 996.81 0.0009077
0.4700 22308.7898 0.0922 0.9996 1.3824
0.4700 19884.6369 0.0922 0.9996 1.0985
0.2800 17460.4841 0.0550 0.9994 0.8485
0.2500 15036.3312 0.0491 0.9993 0.6298
0.2400 12612.1783 0.0471 0.9992 0.4435
0.2200 10188.0255 0.0432 0.9992 0.2899
0.1800 7763.8726 0.0353 0.9990 0.1690
0.1500 5339.7197 0.0294 0.9988 0.0805
0.1200 2915.5669 0.0236 0.9985 0.0245
0.1000 491.4140 0.0196 0.9982 0.0008

Tabel C.29 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 7 cm

U X 10-6
Vp
ρaquades μaquades
L (m) 3
Vu (m ) X105 Dp (m) ε (Pa.s) ΔP (Pa)
(m/s) (kg/m3) (x105)
(m3)
0.0300 0.0000 0.0059 0.9899 0.0000
0.1500 491.4140 0.0294 0.9980 0.0015
0.1800 2915.5669 0.0353 0.9983 0.0413
0.2100 5339.7197 0.0412 0.9986 0.1357
0.2550 7763.8726 0.0500 0.9988 0.2844
0.3050 10188.0255 0.0599 0.9990 0.4876
0.3700 12612.1783 0.0726 0.9992 0.7454
5.9612 0.000175 996.5950 0.0008919
0.4700 15036.3312 0.0922 0.9994 1.0574
0.4700 12612.1783 0.0922 0.9994 0.7444
0.3400 10188.0255 0.0667 0.9991 0.4872
0.2550 7763.8726 0.0500 0.9988 0.2844
0.2140 5339.7197 0.0420 0.9986 0.1356
0.1800 2915.5669 0.0353 0.9983 0.0413
0.1500 491.4140 0.0294 0.9980 0.0015
Tabel C.30 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 150-200 mc
dan Tinggi Unggun Awal 9 cm

U X 10-6
Vp
ρaquades μaquades
L (m) Vu (m3) X105 Dp (m) ε (Pa.s) ΔP (Pa)
(m/s) (kg/m3) (x105)
(m3)
0.0900 0.0000 0.0177 0.9970 0.0000
0.1990 2424.1529 0.0391 0.9985 0.0483
0.2500 4848.3057 0.0491 0.9988 0.1854
0.2950 7272.4586 0.0579 0.9989 0.4119
0.3300 9696.6115 0.0648 0.9991 0.7283
0.3900 12120.7643 0.0765 0.9993 1.1335
0.4700 14544.9172 0.0922 0.9994 1.6278
0.4700 16969.0701 0.0922 0.9995 2.2141
0.4700 19393.2229 0.0922 0.9995 2.8903
0.4700 21817.3758 0.0922 0.9996 3.6565
9.7791 0.000175 996.5950 0.0008919
0.4700 24241.5287 0.0922 0.9996 4.5127
0.4500 21817.3758 0.0883 0.9996 3.6574
0.4000 19393.2229 0.0785 0.9994 2.8933
0.3800 16969.0701 0.0746 0.9993 2.2175
0.3500 14544.9172 0.0687 0.9992 1.6318
0.3300 12120.7643 0.0648 0.9992 1.1355
0.3000 9696.6115 0.0589 0.9990 0.7292
0.2700 7272.4586 0.0530 0.9988 0.4127
0.2500 4848.3057 0.0491 0.9985 0.1854
0.1200 2424.1529 0.0236 0.9982 0.0506

Tabel C.31 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 3 cm

U X 10-6
Vp
ρaquades μaquades
L (m) 3
Vu (m ) X105 Dp (m) ε (Pa.s) ΔP (Pa)
(m/s) (kg/m3) (x105)
(m3)
0.0300 0.0000 0.0059 0.9937 0.0007
0.0600 491.414013 0.0118 0.9969 0.0199
0.0800 2915.56688 0.0157 0.9976 0.0655
0.1000 5339.71975 0.0196 0.9981 0.1375
0.1200 7763.87261 0.0236 0.9984 0.2360
0.1600 10188.0255 0.0314 0.9988 0.3618
0.2100 12612.1783 0.0412 0.9991 0.5151
3.7053 0.000225 996.5950 0.0008919
0.2500 15036.3312 0.0491 0.9992 0.3650
0.2300 12612.1783 0.0451 0.9992 0.2401
0.2000 10188.0255 0.0393 0.9991 0.1371
0.1700 7763.87261 0.0334 0.9989 0.0652
0.1500 5339.71975 0.0294 0.9987 0.0198
0.1200 2915.56688 0.0236 0.9984 0.0007
0.0700 491.414013 0.0137 0.9973 0.0007
Tabel C.32 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 6 cm

U X 10-6
L (m) Vu (m3) Vp (m3) Dp ε ro miu delta P
(m/s)
0.0600 0.0000 0.0118 0.993974 0.0000
0.1500 491.4140 0.0294 0.996987 0.0014
0.1800 2915.5669 0.0353 0.99759 0.0409
0.2200 5339.7197 0.0432 0.997991 0.1341
0.2550 7763.8726 0.0500 0.998278 0.2814
7.5791 0.000225 996.5950 0.0008919
0.3000 10188.0255 0.0589 0.998661 0.4825
0.2900 7763.8726 0.0569 0.998937 0.2809
0.2600 5339.7197 0.0510 0.999139 0.1337
0.2100 2915.5669 0.0412 0.999262 0.0406
0.1800 491.4140 0.0353 0.999397 0.0014

Tabel C.33 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 7 cm

U X 10-6
Vp
ρaquades μaquades
L (m) Vu (m3) X105 Dp (m) ε (Pa.s) ΔP (Pa)
(m/s) (kg/m3) (x105)
(m3)
0.0700 0.0000 0.0001374 0.4789 0.0000
0.1500 491.4140 0.0002944 0.7568 6.6001
0.1800 2915.5669 0.0003533 0.7974 32.9451
0.2150 5339.7197 0.0004219 0.8304 54.8218
0.2700 7763.8726 0.0005299 0.8649 72.7847
0.3400 10188.0255 0.0006673 0.8927 92.4112
0.4700 12612.1783 0.0009224 0.9224 110.3525
0.4700 15036.3312 0.0009224 0.9224 150.1972
0.4700 17460.4841 0.0009224 0.9224 196.0503
0.4700 19884.6369 0.0009224 0.9224 247.9118
7.1580 0.000225 996.595 0.0008919
0.4700 22308.7898 0.0009224 0.9224 305.7816
0.4700 19884.6369 0.0009224 0.9224 247.9118
0.3900 17460.4841 0.0007654 0.9065 212.4147
0.3500 15036.3312 0.0006869 0.8958 173.2995
0.2900 12612.1783 0.0005691 0.8742 145.7960
0.2400 10188.0255 0.0004710 0.8480 121.8825
0.2300 7763.8726 0.0004514 0.8414 85.1476
0.2000 5339.7197 0.0003925 0.8176 60.0261
0.1200 2915.5669 0.0002355 0.6961 68.8087
0.1900 491.4140 0.0003729 0.8080 4.3236
Tabel C.34 Data Penentuan ΔP berdasarkan Perhitungan pada Fluidisasi Cair dengan Ukuran Partikel 200-250 mc
dan Tinggi Unggun Awal 9 cm

U X 10-6
Vp
ρaquades μaquades
L (m) Vu (m3) X105 Dp (m) ε (Pa.s) ΔP (Pa)
(m/s) (kg/m3) (x105)
(m3)
0.0900 0.0000 0.0001766 0.993974 0.0000

0.1810 491.4140 0.0003552 0.996987 10.9358

0.2400 2915.5669 0.0004710 0.99759 44.5872

0.2900 5339.7197 0.0005691 0.997991 73.0187

0.3600 7763.8726 0.0007065 0.998278 98.1419

0.4700 10188.0255 0.0009224 0.998661 121.4739


9.6001 0.000225 996.595
0.4700 12612.1783 0.0009224 0.0008919 172.5974
0.998937
0.4700 10188.0255 0.0009224 0.999139 121.4739

0.3500 7763.8726 0.0006869 0.999262 100.7407

0.3000 5339.7197 0.0005888 0.999397 70.1174

0.2100 2915.5669 0.0004121 0.999397 55.4133

0.1200 491.4140 0.0002355 0.999397 30.4949

C.7 Penentuan Umf berdasarkan Perhitungan pada Fluida Gas

Tabel C.35 Data Penentuan Umf berdasarkan Perhitungan dengan Ukuran Partikel 150-200 mc Fluida Gas
Tinggi Unggun 5 cm 7cm 8 cm
Ar 381.6286 381.6286 381.6286
Re 0.2312 0.2312 0.2312
Umf (m/s) 0.0174 0.0174 0.0174

Tabel C.36 Data Penentuan Umf berdasarkan Perhitungan dengan Ukuran Partikel 200-250 mc Fluida Gas
Tinggi Unggun 5 cm 7cm 8 cm
Ar 644.9203 644.9203 644.9203
Re 0.3907 0.3907 0.3907
Umf (m/s) 0.0229 0.0229 0.0229

Tabel C.37 Data Penentuan Umf berdasarkan Perhitungan dengan Ukuran Partikel 200-250 mc Fluida Gas
Tinggi Unggun 3 cm 6 cm 7 cm 9 cm
Ar 31.5912 31.5912 32.6596 32.6596
Re 0.0191 0.0191 0.0198 0.0191
Umf (m/s) 0.00009938 0.00009938 0.0001013 0.0001013

Tabel C.38 Data Penentuan Umf berdasarkan Perhitungan dengan Ukuran Partikel 200-250 mc Fluida Gas
Tinggi Unggun 3 cm 6 cm 7 cm 9 cm
Ar 26.69331 26.69331 479.9069 479.9069
Re1 0.0162 0.0162 0.2896 0.2896
Umf (m/s) 0.00006436 0.00006436 0.00006436 0.00006436
C.8 Penentuan Umf berdasarkan Kurva Karakteristik Percobaan dan Perhitungan pada Fluida Gas
C.8.1 Penentuan Umf berdasarkan Kurva Karakteristik Percobaan
C.8.1.1 Fluida Gas

500
450
400
350
300
P (Pa) 250
200 kenaikan
150 penurunan
100
50
0
0 20 40 60
Ux 103(m/s)

Gambar C.3 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 5 cm

700
600
500
P (Pa)

400
300 Kenaikan
200 Penurunan
100
0
0 20 40 60
Ux 103(m/s)

Gambar C.4 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 7 cm

800
700
600
500
P (Pa)

400
Kenaikan
300
200 Penurunan
100
0
0 20 40 60
U x 103(m/s)

Gambar C.5 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 8 cm
350
300
250

P (Pa)
200
150 Kenaikan
100 Penurunan
50
0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.6 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 5 cm

600

500

400
P (Pa)

300
Kenaikan
200
Penurunan
100

0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.7 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 7 cm

700
600
500
P (Pa)

400
300 Kenaikan
200 Penurunan
100
0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.8 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 8 cm
C.8.1.2 Fluida Cair

6000

5000

4000

P (Pa)
3000
Kenaikan
2000
Penurunan
1000

0
0 0.01 0.02 0.03 0.04 0.05
Ux 103(m/s)

Gambar C.9 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 3 cm

Percobaan
12000

10000

8000
P (Pa)

6000
Kenaikan
4000 Penurunan

2000

0
0 5 10 15 20 25
Ux 103(m/s)

Gambar C.10 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 6 cm

5000
4500
4000
3500
3000
P (Pa)

Kenaikan
2500
2000 Penurunan
1500
1000
500
0
0 5 10 15 20
Ux 103(m/s)
Gambar C.11 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 7 cm
16000
14000
12000
10000

P (Pa)
8000
Kenaikan
6000
4000 Penurunan
2000
0
0 5 10 15 20 25 30
U x 103(m/s)

Gambar C.12 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 9 cm

10000
9000
8000
7000
6000
P (Pa)

5000
4000 Kenaikan
3000 Penurunan
2000
1000
0
0 5 10 15 20
U x 103(m/s)

Gambar C.13 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 3 cm

9000
8000
7000
6000
P (Pa)

5000
4000 Kenaikan
3000
Penurunan
2000
1000
0
0 2 4 6 8 10 12
Ux 103(m/s)

Gambar C.14 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 6 cm
14000
12000
10000

P (Pa)
8000
6000 Kenaikan
4000 Peurunan
2000
0
0 5 10 15 20 25
U x 103(m/s)

Gambar C.15 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 7 cm

10000
9000
8000
7000
6000
P (Pa)

5000
4000 Kenaikan
3000 Penurunan
2000
1000
0
0 5 10 15
U x 103(m/s)

Gambar C.16 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 9 cm

C.8.2 Penentuan Umf berdasarkan Kurva Karakteristik Perhitungan


C.8.2.1 Fluida Gas

600

500

400
P (Pa)

300
Kenaikan
200
Penurunan
100

0
0 20 40 60
U (m/s)

Gambar C.17 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 5 cm
500
450
400
350
300

P (Pa)
250 Kenaikan
200 Penurunan
150
100
50
0
0 20 U x 1040
3(m/s) 60

Gambar C.18 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 7 cm

600

500

400
P (Pa)

300
Kenaikan
200
Penurunan
100

0
0 20 40 60
U x 103(m/s)

Gambar C.19 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 8 cm

200
180
160
140
120
P (Pa)

100
80 Kenaikan
60 Penurunan
40
20
0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.20 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 5 cm
60

50

40

P (Pa)
30
Kenaikan
20
Penurunan
10

0
0 20 40 60 80 100
U x 103(m/s)

Gambar C.21 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 7 cm

350
300
250
P (Pa)

200
150 Kenaikan
100 Penurunan
50
0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.22 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 9 cm

C.8.2.2 Fluida Cair

0.00001
0.000009
0.000008
0.000007
0.000006
P (Pa)

0.000005
0.000004 Kenaikan
0.000003 Penurunan
0.000002
0.000001
0
0 0.01 0.02 0.03 0.04 0.05
U x 103(m/s)

Gambar C.23 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 3 cm
1.6
1.4
1.2
1

P (Pa)
0.8
Kenaikan
0.6
Penurunan
0.4
0.2
0
-0.2 0 5 10 15 20 25
U x 103(m/s)

Gambar C.24 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 6 cm

1.2
1
0.8
P (Pa)

0.6
0.4
0.2
0
0 2 4 6 8 10 12 14 16
Ux 103(m/s)

Gambar C.25 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 7 cm

5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
0 5 10 15 20 25 30

Gambar C.26 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
150-200 mc dengan Tinggi Unggun Awal 9 cm
0.6

0.5

0.4

P (Pa)
0.3
Kenaikan
0.2
Penurunan
0.1

0
0 5 10 15 20
U x 103(m/s)

Gambar C.27 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 3 cm

0.6

0.5

0.4
P (Pa)

0.3
Kenaikan
0.2
Penurunan
0.1

0
0 2 4 6 8 10 12
-0.1
U x 103(m/s)

Gambar C.28 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 6 cm

350
300
250
P (Pa)

200
150 Kenaikan
100 Penurunan
50
0
0 5 10 15 20 25
Ux 103(m/s)

Gambar C.29 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 7 cm
200
180
160
140
120

P (Pa)
100
80 Kenaikan
60 Penurunan
40
20
0
0 5 10 15
Ux 103(m/s)

Gambar C.30 Kurva Penentuan Umf berdasarkan Kurva Karakteristik Fluidisasi dengan Ukuran Partikel
200-250 mc dengan Tinggi Unggun Awal 9 cm

Tabel C.39 Nilai Umf pada Fluidisasi Gas (Kurva)


Umf (m/s)
Lo (cm) Gas
150-200 mc 200-250 mc
2
3
4 0

Tabel C.40 Nilai Umf pada Fluidisasi Cair (Kurva)


Umf (m/s)
Lo (cm) Gas
150-200 mc 200-250 mc
2
3
4
6
C.9 Kurva L Terhadap U Pada Fluida Gas

0.1
0.09
0.08
0.07
0.06

L (m)
0.05 Lo=5 cm
0.04
Lo= 7 cm
0.03
0.02 Lo= 8 cm
0.01
0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.31 Kurva L terhadap U dengan Ukuran Partikel 150-200 mc

0.09
0.08
0.07
0.06
0.05
L (m)

Lo= 5 cm
0.04
0.03 Lo= 7 cm
0.02 Lo= 8 cm
0.01
0
0 20 40 60 80 100
Ux 103(m/s)

Gambar C.32 Kurva L terhadap U dengan Ukuran Partikel 200-250 mc

C.10 Kurva L Terhadap U Pada Fluida Cair

0.5
0.45
0.4
0.35
0.3 Lo=3 cm
L (m)

0.25
0.2 Lo=6 cm
0.15 Lo=7 cm
0.1
0.05 Lo=9 cm
0
0 5 10 15 20 25 30
Ux 103(m/s)

Gambar C.33 Kurva L terhadap U dengan Ukuran Partikel 150-200 mc


0.6

0.5

0.4
Lo=3 cm

L (m)
0.3
Lo=6 cm
0.2
Lo= 7 cm
0.1 Lo=9 cm
0
0 5 10 15 20 25
Ux 103(m/s)

Gambar C.34 Kurva L terhadap U dengan Ukuran Partikel 200-250 mc